• 제목/요약/키워드: phasor shift

검색결과 7건 처리시간 0.022초

Phasor 제어형 SIT 고주파 공진 Inverter (Phasor Control-Based High Frequency Resonance Inverter using Power SIT)

  • 정원영;노채균;김동희;소정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.382-384
    • /
    • 1994
  • This paper proposed a novel High Frequency resonant inverter having drive signal phasor shift control function. The operating characteristics of this inverter circuit are discussed from a thereotical point of view and comparated with experimental results.

  • PDF

복 공진형 고주파 인버터의 특성해석과 설계 (Design and characteristics analysis of Double resonant type High frequency Inverter using Phasor shift)

  • 김종해;원재선;김동희;조규판;심광열;이봉섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2100-2102
    • /
    • 1998
  • A full bridge double resonant type inverter using Phasor shift suitable for heating magnetic and nonmagnetic at high frequency is described. A series-parallel arrangement of capacitor is adopted and optimum mode of operation is proposed. Also, Based on the characteristics value, a method of circuit design is proposed.

  • PDF

구동 신호 Phasor 제어형 SIT 고주파 공진 인버터 (Drive Signal Phasor Control-Based High Frequency Resonant Inverter Using Power-SIT)

  • 김동희;노채균;김종해;정원영
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.51-57
    • /
    • 1998
  • 본 논문은 구동신호 위상제어 기능을 갖는 SIT고주파공진 인버터를 제안하였다. SIT를 이용한 위상제어형인버터는 낮은 스위칭 손실로서 높은 스위칭 주파수의 전력변환을 실현시킬 수 있다. 특히 2단위 인버터의 출력전압을 직렬로 연결하여 높은 출력을 얻을 수 있다. 과전류에 대해서 보호회로를 이용한 시스템의 안정성과 그리고 PLL에 의해 부하변화에 따른 자동추종제어를 실현하였다. 특히 제안된 인버터는 고주파에서도 거의 정현파에 가까우며, 스위칭 주파수 범위는 180∼220〔kHz〕이고, 2〔kW〕의 유도가열에 응용하였다. 본 인버터의 동작 특성에 대해서 이론과 실험결과를 비교 검토하였다.

  • PDF

Preventive and Emergency Control of Power System for Transient Stability Enhancement

  • Siddiqui, Shahbaz A.;Verma, Kusum;Niazi, K.R.;Fozdar, Manoj
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.83-91
    • /
    • 2015
  • This paper presents preventive and emergency control measures for on line transient stability (security) enhancement. For insecure operating state, generation rescheduling based on a real power generation shift factor (RPGSF) is proposed as a preventive control measure to bring the system back to secure operating state. For emergency operating state, two emergency control strategies namely generator shedding and load shedding have been developed. The proposed emergency control strategies are based on voltage magnitudes and rotor trajectories data available through Phasor Measurement Units (PMUs) installed in the systems. The effectiveness of the proposed approach has been investigated on IEEE-39 bus test system under different contingency and fault conditions and application results are presented.

3-레벨 인버터를 이용한 유도가열 시스템의 출력제어 연구 (An Output Control Research of an Induction Heating System Which Uses a 3-Level Inverter)

  • 김성호;권혁민;신대철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.791-794
    • /
    • 2004
  • This paper made an induction heating inverter. The inverter is the $20\~40[kHz]$ a resonant inverter which uses a high frequency. We use this inverter and use induction heating. A phasor shift ordered a gate signal to adjust an inverter's output. We verified an output waveform according to the situation of a gate signal through the simulation. We made the inverter really and got the result.

  • PDF

Islanding Detection for Distributed Generation

  • Ding, X.;Crossley, P.A.;Morrow, D.J.
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.19-28
    • /
    • 2007
  • The paper discussed various techniques for islanding detection and described in detail the working principles of ROCOF and vector shift relays. A simulator was used to investigate why the stability of both types of relays maybe affected by network and load switching, short-circuit faults and in the case of a ROCOF relay the loss of bulk generation or the tripping of a transmission feeder. Finally, to enhance the reliability of Loss of Mains protection, a new islanding detection technique based on a GPS synchronized phasor measurement system was proposed.

공진형 인버터를 위한 범용 퍼지 논리 제어기 설계 (General Digital Fuzzy Logic Controller Design For Resonant Inverter)

  • 김태언;김남수;임영도
    • 융합신호처리학회논문지
    • /
    • 제5권1호
    • /
    • pp.60-65
    • /
    • 2004
  • 고주파 유도 가열 시스템에서 철과 같은 물체를 가열하게 되면, 가열된 금속이 큐리점 부근에서 전기적인 임피던스가 급격하게 변화하는 특징을 가지는 시변 시스템이 된다. 또한 부하 임피던스가 변화함에 따라 시스템의 부하 공진 주파수가 달라지므로 해서 시스템의 효율이 감소하는 문제점이 있었다. 그리고, 피가열 물체의 용융이나 삽입 상태에 따른 시스템의 단락 현상으로 인해 시스템이 파괴되는 문제점이 있었다. 본 논문에서는 이런 문제점을 해결하기 위한 방법으로 PLL에 의한 부하 공진 주파수를 추종하면서 스위칭 손실을 줄이고, 시변 부하에 대한 유도 가열시 큐리점 부근의 급격한 부하 임피던스 변화에도 안정된 정전력 제어가 가능할 뿐 아니라 대전력용에 적합하고, 단락현상으로부터 시스템을 보호하는 병렬 공진형 인버터 시스템에 적용되는 퍼지논리 제어기를 설계하였다.

  • PDF