• Title/Summary/Keyword: phasor shift

Search Result 7, Processing Time 0.017 seconds

Design and characteristics analysis of Double resonant type High frequency Inverter using Phasor shift (복 공진형 고주파 인버터의 특성해석과 설계)

  • Kim, Jong-Hae;Won, Jae-Sun;Kim, Dong-Hee;Cho, Kyu-Phan;Sim, Kwang-Yul;Lee, Bong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2100-2102
    • /
    • 1998
  • A full bridge double resonant type inverter using Phasor shift suitable for heating magnetic and nonmagnetic at high frequency is described. A series-parallel arrangement of capacitor is adopted and optimum mode of operation is proposed. Also, Based on the characteristics value, a method of circuit design is proposed.

  • PDF

Drive Signal Phasor Control-Based High Frequency Resonant Inverter Using Power-SIT (구동 신호 Phasor 제어형 SIT 고주파 공진 인버터)

  • 김동희;노채균;김종해;정원영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.51-57
    • /
    • 1998
  • This paper proposed a novel SIT high frequency resonant inverter having drive signal phase shift control function. Phasor control type inverters using SIT can realize a power conversion on the high switching frequency with low switching loss. Especially, the high output power can be abstained by connecting the output voltage of two unit inverters In serIes. The stability of system using protection circuit for over current and the automatic follow-up control with load variation by PLL is presented. This inverter produce approximately sinusoidal waveform at a high frequency, switching frequency ranging from 180[kHz] to 220[kHz], and is applied to the 2[kW] induction heating. The operating characteristics of this inverter circuit are discussed from a theoretical point of view and compared with experimental results. results.

  • PDF

Preventive and Emergency Control of Power System for Transient Stability Enhancement

  • Siddiqui, Shahbaz A.;Verma, Kusum;Niazi, K.R.;Fozdar, Manoj
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.83-91
    • /
    • 2015
  • This paper presents preventive and emergency control measures for on line transient stability (security) enhancement. For insecure operating state, generation rescheduling based on a real power generation shift factor (RPGSF) is proposed as a preventive control measure to bring the system back to secure operating state. For emergency operating state, two emergency control strategies namely generator shedding and load shedding have been developed. The proposed emergency control strategies are based on voltage magnitudes and rotor trajectories data available through Phasor Measurement Units (PMUs) installed in the systems. The effectiveness of the proposed approach has been investigated on IEEE-39 bus test system under different contingency and fault conditions and application results are presented.

An Output Control Research of an Induction Heating System Which Uses a 3-Level Inverter (3-레벨 인버터를 이용한 유도가열 시스템의 출력제어 연구)

  • Kim Sunh-Ho;Kwon Hyuk-Min;Shin Dae-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.791-794
    • /
    • 2004
  • This paper made an induction heating inverter. The inverter is the $20\~40[kHz]$ a resonant inverter which uses a high frequency. We use this inverter and use induction heating. A phasor shift ordered a gate signal to adjust an inverter's output. We verified an output waveform according to the situation of a gate signal through the simulation. We made the inverter really and got the result.

  • PDF

Islanding Detection for Distributed Generation

  • Ding, X.;Crossley, P.A.;Morrow, D.J.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.19-28
    • /
    • 2007
  • The paper discussed various techniques for islanding detection and described in detail the working principles of ROCOF and vector shift relays. A simulator was used to investigate why the stability of both types of relays maybe affected by network and load switching, short-circuit faults and in the case of a ROCOF relay the loss of bulk generation or the tripping of a transmission feeder. Finally, to enhance the reliability of Loss of Mains protection, a new islanding detection technique based on a GPS synchronized phasor measurement system was proposed.

General Digital Fuzzy Logic Controller Design For Resonant Inverter (공진형 인버터를 위한 범용 퍼지 논리 제어기 설계)

  • 김태언;김남수;임영도
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.60-65
    • /
    • 2004
  • Induction heating system is time varying system around curie point. So, it has many troubles which are system shut down and change the load impedance. In this paper has been designed the parallel resonant inverter which controlling the constant power and tracking the load resonant frequency with PLL is possible, in order to minimize switching losses and solve it's many troubles. The current full-bridge type parallel resonant inverter of an induction heating system was composed of IGBT in switching device. For regulating the output power of an induction heating system, the Fuzzy logic controller is used. The Fuzzy controller makes the control signal for a stable power regulating control and when reference is changed, it is superior to adaptability. It has been evaluated a stable behavior for a noise with switching and a load disturbance.

  • PDF