• Title/Summary/Keyword: phase difference

Search Result 3,110, Processing Time 0.033 seconds

Design of a Phase Splitter(2.4[GHz]) using Differential Amplifier (자동증폭기를 이용한 위상분상기(Phase Splitter) 설계)

  • Roh, Hee-Jung;Seo, Choon-Weon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.14-17
    • /
    • 2008
  • This paper describes the simulation of a phase splitter for the design of Chireix Outphasing power amplifier. Phase splitter separate the input signal with $0[^{\circ}]$ into the signal with $+90[^{\circ}]$ and $-90[^{\circ}]$ Chireix Outphasing power amplifier get a linearized output from the signal amplifying and combining the separated signal with the phase of $+90[^{\circ}]$ and $-90[^{\circ}]$ of the phase splitter. phase splitter is the core device when designing Chireix Outphasing power amplifier. It is very difficult to design phase splitter with the difference of $90[^{\circ}]$. This phase splitter is used to design the difference of $180[^{\circ}]((90[^{\circ}]+{\alpha}),\;-(90[^{\circ}])+{\alpha}))$ using simulation tool and a differential amplifier.

Kinematic Analysis of Service Movement In Each Position of Soft Tennis (포지션별 정구 플랫서비스의 운동학적분석)

  • Kim, Hun-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.221-231
    • /
    • 2002
  • The purpose of this study was to clarify the differences in service patterns of a forward and backward soft tennis players using 3D motion analyzer. Subjects were 4 forward players of $24.0\pm5.23$yrs and 4 backward players of $23.5\pm1.73$yrs. The results were as following: 1. There was no difference among each positions on swinging-time. The longest racket swinging-time was in the phase of takeback, the second one was in follow-through. The shortest one was in the phase of forward-swing so called force production phase, which had an influence on ball's velocity. 2. The racket speed on impact was 16.3m/s in forward subject and 19.53m/s in backward subject, when each velocity of balls was 44.6m/s, 52.9m/s. Although there was no significant difference along by positions, backward subject showed faster result. 3. The maximum speed of each performance was reached before the impact, and the speed at impact along by positions did not show any significant difference. The summation of velocity was measured in good order as following; hip, shoulder, elbow, wrist, top of racket. 4. In the angular velocity of all examine except one, the angular velocity of forearm was bigger than the one of racket top although there was no statistically significant difference between forward and backward subject. 5. The service grip of the forward players was shorter than that of backward players.

A Kinematic Comparative Analysis of Yoko Ukemi(side breakfall) by Each Stage in Judo[ I ] (유도 단계별 측방낙법의 운동학적 변인 비교분석[ I ])

  • Kim, Eui-Hwan;Kim, Sung-Sup
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.203-218
    • /
    • 2004
  • The purpose of this study was to analyze the comparisons of the kinematical variables when performing Yoko Ukemi(side breakfall) by three Stage in Judo. The subjects were four male judokas who were trainees Y. I. University Squad members and the Yoko Ukemi were filmed by two S-VHS 16mm video cameras(60fields/sec.). The selected times were subject to KWON 3D analysis program and kinematical analysis to compare variables of three Yoko Ukemi. Temporal variables(total time-required : TK, TR by each phase), the body part touched order on the mat and COG variables were computed through video analysis while performing right Yoko Ukemi by three stage. From the data analysis and discussion, the following conclusions were drawn : 1. Temporal variables : total time-required(TR) when performing Yoko Ukemi(side breakfall) by each stage, the first stage(full squat posture: FP : 1.11sec.) showed the shortest time, the next was 3rd(Shizenhontai, straight natural posture: NP : 1.41sec.), and 2nd(Jigohontai, straight defensive posture, DP : 1.42sec.), respectively- 2. TR when performing Yoko Ukemi(side breakfall) by each stage, and phase : the first phase(take of phase, average 0.68sec.) showed the longest time, next was the third phase(ukemi phase, 0.39sec.), and the second phase(air phase, 0.23sec.), respectively. 3. When performing yore Ukemi the body part touched order and TR on the mat : hip(0.94sec.) showed the shortest time, the next was elbow hand(0.97sec.), back(0.98sec.), and shoulder(1.04sec.) order. The hip part touched on the mat the first, but slap the mat in order to alleviate the shock try hand palm and forearm before receiving impact (difference 0.03sec,) 4. Vertical COG variables in each event by each stage : e1(ready position, average 78.33cm) moved the highest, the next was e2(jumping position, 70.14cm), e3(transition position, average 64.00cm), e4(landing position, average 35.99cm), and e5(ukemi position, average 18.32cm) order, gradual decrease respectively. And the difference of COG were showed in initial by each stage, because position fo Yoko Ukemi was difference by each stage in preparation position, but in accordance with executing of Ukemi phase that difference of COG was by decreasing, almost equal displacement in e4(landing) and e5(Ukemi)position finally.

A Study on Islandig Characteristics using Phase Angle Adjustment of Distributed Generation (배전계통연계 분산전원의 위상변화에 따른 고립운전 파라미터 특성)

  • Bang, Ji-Yoon;Kim, Hak-Man;Lee, Bock-Ku;Sim, Jae-Sun;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.525-526
    • /
    • 2006
  • Recently, much research has been done and many improvements have been developed for islanding protection of distributed generation(DG). Anti-islanding protection for DG must be act very quickly to prevent equipment damage at the time of disconnection and for the safety of maintenance and repair personnel. DG-based detection methods have included both passive and active types, and now research has shifted towards new anti-islanding detection methods that make up for the defects of the previous types. Because differences occur between the utility grid and the DG when connecting and disconnecting depending on the phase difference, voltage, current, relative capacity of electric power, and system operation characteristics, voltage phase angle is an important consideration. In this paper, we simulated islanded operation characteristics comparing phase difference of DG and the connected utility grid, and analyzed various parameters (real power, reactive power, RMS voltage, RMS current, power factor angle, and frequency) by varying the DG's voltage phase angle. Using this information, we propose a suitable DG voltage phase angle for enhanced passive islanding detection techniques.

  • PDF

A Multiple Gain Controlled Digital Phase and Frequency Detector for Fast Lock-Time (빠른 Lock-Time을 위한 다중 이득 제어 디지털 위상 주파수 검출기)

  • Hong, Jong-Phil
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.46-52
    • /
    • 2014
  • This paper presents a multiple gain controlled digital phase and frequency detector with a fast lock-time. Lock-time of the digital PLL can be significantly reduced by applying proposed adaptive gain control technique. A loop gain of the proposed digital PLL is controlled by three conditions that are very large phase difference between reference and feedback signal, small phase difference and before lock-state, and after lock-state. The simulation result shows that lock-time of the proposed multiple gain controlled digital PLL is 100 times faster than that of the conventional structure with unit gain mode.

GAS-LIQUID TWO-PHASE HOMOGENEOUS MODEL FOR CAVITATING FLOW (캐비테이션 유동해석을 위한 기-액 2상 국소균질 모델)

  • Shin, Byeong-Rog
    • Journal of computational fluids engineering
    • /
    • v.12 no.2
    • /
    • pp.53-62
    • /
    • 2007
  • A high resolution numerical method aimed at solving cavitating flow is proposed and applied to gas-liquid two-phase shock tube problem. The present method employs a finite-difference 4th-order Runge-Kutta method and Roe's flux difference splitting approximation with the MUSCL TVD scheme. By applying the homogeneous equilibrium cavitation model, the present density-based numerical method permits simple treatment of the whole gas-liquid two-phase flow field, including wave propagation and large density changes. The speed of sound for gas-liquid two-phase media is derived on the basis of thermodynamic relations and compared with that by eigenvalues. By this method, a Riemann problem for Euler equations of one dimensional shock tube was computed. Numerical results such as detailed observations of shock and expansion wave propagations through the gas-liquid two-phase media at isothermal condition and some data related to computational efficiency are made. Comparisons of predicted results and exact solutions are provided and discussed.

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.

Reducing the Thrust Ripple Generated by the Stacking of Stator Phase Windings of a Linear Pulse Motor (리니어 펄스모터의 고정자 상권선 적층에 따른 추력 리플 저감 기법 연구)

  • Choi, Jaehuyk;Zun, Chanyong;Mok, Hyungsoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.447-452
    • /
    • 2017
  • The stator phase winding of a linear pulse motor, which is a new type of linear motor, is comprised of two phases and is structurally characterized by a stacking method in which the winding of one phase is laid on top of the winding of another phase. Such a structural characteristic induces a difference in the flux linkage resulting from the flux of each stator phase winding in the same condition. The difference in the induced flux linkage acts as a kind of thrust ripple component in terms of the generated thrust. Thus, in order to maintain consistent thrust force, a method is required to solve the problem caused by the structural singularity. Hence, in this study, we present a technique for reducing the thrust force ripple generated by the stacking of the stator phase windings of a linear pulse motor through the generation of a compensating current reference value of the current controller in order to keep the torque constant. The proposed compensating algorithm is validated by simulations and experimental results.

Thermal-mechanical Fatigue Life Prediction of 12Cr Forged Steel Using Strain Range Partitioning method (변형률분할법에 의한 12Cr 단조강의 열피로 수명예측)

  • 하정수;옹장우;고승기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1192-1202
    • /
    • 1994
  • Fatigue behavior and life prediction were presented for thermal-mechanical and isothermal low cycle fatigue of 12Cr forged steel used for high temperature applications. In-phase and out-of-phase thermal-mechanical fatigue test at 350 to 600.deg. C and isothermal low cycle fatigue test at 600.deg. C were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. Cyclic softening behavior was observed regardless of thermal-mechanical and isothermal fatigue tests. The phase difference between temperature and strain in thermal-mechanical fatigue resulted in significantly shorter fatigue life for out-of-phase than for in-phase. The difference in fatigue lives was dependent upon the magnitudes of inelastic strain ranges and mean stresses. Increase in inelastic strain range showed a tendency of intergranular cracking and decrease in fatigue life, especially for out-of-phase thermal-mechanical fatigue. Thermal-mechanical fatigue life prediction was made by partitioning the strain ranges of the hysteresis loops and the results of isothermal low cycle fatigue tests which were performed under the combination of slow and fast strain rates. Predicted fatigue lives for out-of-phase using the strain range partitioning method showed an excellent agreement with the actual out-of-phase thermal-mechanical fatigue lives within a factor of 1.5. Conventional strain range partitioning method exhibited a poor accuracy in the prediction of in-phase thermal-mechanical fatigue lives, which was quite improved conservatively by a proposed strain range partitioning method.

A Study on the Phase Bandwidth Frequency of a Directional Control Valve Based on the Hydraulic Line Pressure (배관 압력을 이용한 방향제어밸브 위상각 대역폭 주파수 측정에 관한 연구)

  • Kim, Sungdong;Lee, Jung-eun;Shin, Daeyoung
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.1-10
    • /
    • 2018
  • Spool displacement of a direction control valve is the standard signal to measure the bandwidth frequency of the direction control valve. When the spool displacement signal is not available, it is suggested in this study to use the metering hydraulic line as an alternative way to measure - 90 degree phase bandwidth frequency of the hydraulic direction control valve. Dynamics of the hydraulic line is composed of inertia, capacitance, and friction effects. The effect of oil inertia is dominant in common hydraulic line dynamics and the line dynamics is close to a derivative action in a range of high frequency; such as a range of bandwidth frequency of common directional control valves. Phase difference between spool displacement and line load pressure is nearly constant as a valve close to 90 degree. If phase difference is compensated from the phase between valve input and pressure, compensated phase may be almost same as the phase of spool displacement that is a standard signal to measure phase bandwidth frequency of the directional control valve. A series of experiments were conducted to examine the possibility of using line pressure in to measure phase bandwidth frequency of a directional control valve. Phase bandwidth frequency could be measured with relatively high precision based on metering hydraulic line technique and it reveals consistent results even when valve input, oil temperature, and supply pressure change.