• 제목/요약/키워드: phase detection

검색결과 2,132건 처리시간 0.034초

The Scheme for Improving the Performance of Ranging Code Detection over OFDMA Systems in Uplink (OFDMA 시스템 상향링크의 레인징 부호 검출 성능 향상 기법)

  • Kim Ki-Nam;Kim Jin-Ho;Cho Sung-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제31권6A호
    • /
    • pp.575-585
    • /
    • 2006
  • In Orthogonal Frequency Division Multiple Access (OFDMA) systems, timing synchronization in uplink is accomplished by an initial uplink synchronization called an initial ranging process. The Base Station's receiver synchronizes the symbol timing to specific user's symbol and the other user's symbols have some Symbol Timing Offset (STO). Linear phase shift is occurred by each user's STO in an OFDMA symbol. The Multiple Access Interference (MAI) caused by the summation of each user's linear phase shift degrades the performance of ranging code detection. In this paper, we propose an initial ranging symbol structure with common ranging code for phase shift estimation and compensation. We car estimate the average of phase shift that is generated by each user's STO and compensate this phase shift by using common ranging code. This scheme will suppress the MAI and provide better detection performance than conventional process.

Vapor Exposure Effect of a Casting Solution on the Embedding and Radioactive Detection of CAYS in Double-layered Polysulffne Film (방사능탐지용 CAYS 함침 이중구조 폴리설폰막의 형상 및 특성에 제막공정의 습도가 미치는 영향)

  • Han Myeong-Jin;Nam Suk-Tae;Lee Kune-Woo;Seo Bum-Kyoung
    • Membrane Journal
    • /
    • 제15권3호
    • /
    • pp.198-205
    • /
    • 2005
  • Double-layered polymer films to assay the radioactive contamination were formulated using polysulfone (PSF) and cerium activated yttrium silicate (CAYS), consisting of a dense support layer and a CAYS-holding top layer prepared via the diffusion-induced phase inversion. As the vapor exposure process was omitted, the CAYS-holding layer showed a typical asymmetric structure, with CAYS being transfixed into the polymer network spread with large macropores. With the increase in vapor exposure time before immersion, morphology of the films transformed from asymmetric to sponge-like structures, with CAYS being localized in cellular structure. The border structure between the two layers reflects the phase inversion behavior of a cast solution during the coagulation. In the radioactive detection, the polymer phase in a film holding a sponge-like structure is so dense that the radionuclides, deposited on the film, could not filter through the phase, consequently resulting in the loss in the detection efficiency of the film.

Collaborative Process to Facilitate BIM-based Clash Detection Tasks for Enhancing Constructability

  • Seo, Jung-Ho;Lee, Baek-Rae;Kim, Ju-Hyung;Kim, Jae-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • 제12권3호
    • /
    • pp.299-314
    • /
    • 2012
  • One of reasons for introducing Building Information Modeling (BIM) is to support clash detection tasks by means of a 3D product model. In the conventional construction project process, clashes have been found during construction phase. However, it can cause cost overrun and time delay. In order to investigate and correct clash detections at design phase, relevant business process and guide for this task should be provided. This study aims to identify hindrances in clash detection tasks at the design phase and analyze its current process using IDEF0 model. Despite the convenience of IDEF0 as a systems analysis tool, professional participants might have difficulties to understand their own tasks according to business process. For this reason, in this research, Business Process Model and Notation (BPMN) is introduced to provide ideal process and required decision making governance. The provide BPMN model will provide insights for a BIM-based collaborative environment to enhance the constructability through the construction project.

The Expanded Current Synchronous Detection for Active Power Filters (능동전력필터를 위한 확장된 전류 동기 검출법)

  • 정영국;김우용;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제6권4호
    • /
    • pp.341-347
    • /
    • 2001
  • Harmonics and fundamental reactive current of nonlinear loads in serious unbalanced power condition, are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system. But, the CSD theory is not suitable any more, in case of controlled independently harmonics and reactive component. Therefore, a new algorithm, the expanded current synchronous detection(ECSD) theory for a three phase active power filter based on decomposition of fundamental reactive, distorted components, is proposed in this paper. The proposed ECSD theory is experimented and tested comparison with a few power theories under asymmetrical condition in power system.

  • PDF

Ungrounded System Fault Section Detection Method by Comparison of Phase Angle of Zero-Sequence Current

  • Yang, Xia;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung;Lim, Seong-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.484-490
    • /
    • 2008
  • In this paper, an integrated fault section detection and isolation strategy is proposed based on the application of the Distribution Automation System(DAS) utilizing advanced IT and communication technologies. The Feeder Remote Terminal Unit(FRTU) has been widely used to collect data in the Korean distribution system. The achieved data is adopted in this method for detecting multiple fault types. Especially in the case of single phase-to-ground fault, the fault section is detected by comparison of the zero-sequence current phase angle. The test results have verified the effectiveness of the proposed method in a radial distribution system through extensive simulations in Matlab/Simulink. Furthermore, a communication-based demo system identical to the simulation model has been developed, and it can be applied as an online monitoring and control program for fault section detection and isolation.

Separation and Detection of Nonchromophore Aliphatic Compounds by Reversed-Phase Liquid Chromatography using Ultraviolet-Absorbing Reagent (자외선 흡수물질을 이용한 역상 액체 크로마토그라피에 의한 비흡수 지방족 화합물들의 검출과 분리)

  • Lee Seung-Seok;Kang Sam-Woo;Oh Hae-Beom
    • Journal of the Korean Chemical Society
    • /
    • 제35권4호
    • /
    • pp.397-404
    • /
    • 1991
  • Nonchromophore compounds such as aliphatic acids, alcohols and tetraalkylammonium salts could be detected by indirect photometric detection on the revered-phase liquid chromatography. Benzyltriethylammonium bromide(BTEAB) was used as a detection reagent. Also, the retention mechanism and response of samples were investigated to the several factors such as pH, temperature, and concentration of MeOH as well as concentration of detection reagents in mobile phase. And some mixture of samples were able to be separated under optimum condition.

  • PDF

A Study on the Satellite Launch Vehicle Separation Detection Interface to Improve the Reliability of the Launch and Early Operation Phase

  • Lee, Nayoung;Kwon, Dong-young;Jeon, Hyeon-Jin;Jeon, Moon-Jin;Cheon, Yee-Jin
    • Journal of Aerospace System Engineering
    • /
    • 제15권4호
    • /
    • pp.57-63
    • /
    • 2021
  • The launch vehicle (LV) separation detection interface of the satellite, which is designed to initiate the launch and early operation phase (LEOP) for S-band data transmission and the solar array deployment after the LV separation, is one of the hazard items at the launch site. Therefore, this interface should satisfy the single-fault tolerance requirement for the range safety. In this paper, we discuss the LV separation detection interfaces for two different satellite launch configurations and propose a method to guarantee for the satellite to start the LEOP even under the emergency case such as a partial separation from the LV. Furthermore, the proposed method meets the range safety requirement of the launch site. As this method only changes the external harness configuration of the satellite, it increases the reliability of the satellite early operation without any modification of the existing internal logics to detect the separation event.

Three-Phase Three-Wire Active Power Filter with a Detection Method of Instantaneous Positive Sequence Voltage (정상분 순시전압 검출기법을 이용한 3상 3선 능동전력필터 시스템)

  • 曺 在 延;鄭 榮 國;任 永 徹
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.178-185
    • /
    • 2002
  • This paper describes the implementation of three-phase three-wire active power filter system with a instantaneous PSD for distorted and unbalanced power conditions. The positive sequence voltage of the distorted and the unbalanced power system is calculated by the Instantaneous PSD, and phase transformation matrix of the instantaneous power theory is achieved with detected positive sequence voltage. Finally, the proposed method is experimented and tested under unbalanced nonlinear load as well as unbalanced /distorted condition in power system.

Determination of Total Phenols in Environmental Waters by Capillary-HPLC with U.S.E.P.A. Classified Eleven Priority Pollutant Phenols after Nitrosation and Their Visible Spectrophotometric Detection

  • Chung, Yong-Soon
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권2호
    • /
    • pp.297-302
    • /
    • 2005
  • The determination of total phenols was accomplished by capillary-high performance liquid chromatography (capillary-HPLC) after nitrosation of the U.S.E.P.A. classified 11 priority pollutant phenols, using the nitrosated parent phenol (POHNO) as a reference for calibration. The optimum mobile phase composition for this analysis was found by examining the effect of changing the percentage of acetonitrile (MeCN) in the mobile phase on retention factors (k values) and peak intensities. As MeCN percentage was increased, k values were reduced and peak intensities were generally increased. From the results obtained, it was found that the optimum mobile phase was 90%(v/v) MeCN solution at pH 8.0, the detection wavelength of 400 nm, and a detection limit (D.L., concentration at signal to noise ratio (S/N) of 3.0) of 4.5 ${\times}$ $10^{-7}$ M. In addition, 10 of the 11 phenols present in mineral or waste water were separated after the nitrosation by capillary-HPLC. The optimum mobile phase for separation was a 40%(v/v) MeCN solution at pH 5.0.

High Speed Grid Voltage Detection Method for 3 Phase Grid-Connected Inverter during Grid Faults (전원사고 시 3상 계통연계 인버터의 전원 전압 고속 검출 방법)

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • 제29권5호
    • /
    • pp.65-72
    • /
    • 2009
  • The new method is proposed to improve high speed detection of grid voltage phase and magnitude during a voltage dip due to a grid faults. Usually, A LPF(Low Pass Filter) is used in the feedback loop of PLL (Phase Locked Loop) system because the measured grid voltage contains harmonic distortions and sensor noises. so, a new design method of the loop gain of the PI -type controller in the PLL system is proposed with the consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and PI controller gain are designed in coordination according to the steady state and dynamic performance requirement. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the lab-scale experiments.