• 제목/요약/키워드: phantom model

검색결과 246건 처리시간 0.026초

Trends in Acupuncture Training Research: Focus on Practical Phantom Models

  • Jang, Jung Eun;Lee, Yeon Sun;Jang, Woo Seok;Sung, Won Suk;Kim, Eun-Jung;Lee, Seung Deok;Kim, Kyung Ho;Jung, Chan Yung
    • Journal of Acupuncture Research
    • /
    • 제39권2호
    • /
    • pp.77-88
    • /
    • 2022
  • The purpose of this review was to identify research trends in acupuncture training systems and models and to analyze acupuncture training using phantom models. Articles on acupuncture training were retrieved from domestic and foreign electronic databases (PubMed, CNKI, CiNii, NDSL, KISS, RISS and KMBase). The search included studies conducted from January 1, 2010 to October 1, 2021. Acupuncture training was analyzed by categorization into acupoint location training and needling training. Acupuncture training was most frequently studied in China, acupoint location training was the most studied in 2012, and needling training was the most studied in 2013 and 2020. Among them, a silicone model with a sensor was used for training in acupoint location, and silicone and agarose gel were frequently used for needling training. Classifications of the phantom models for needling training by topic included phantom development, phantom-based education and evaluation system, phantom-based quantitative measurement, comparison of kinematic characteristics of hand motion between experts and beginners, and phantom models for acupoint location and needling training. Further research on the development of acupuncture practice training systems to improve practical skills is needed.

3D 프린팅을 활용한 일반 X선 촬영 실습용 인체 팬텀 제작 (Making Human Phantom for X-ray Practice with 3D Printing)

  • 최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.371-377
    • /
    • 2017
  • 일반 X선 촬영 실습용 팬텀은 방사선학과에 없어서는 안 되는 중요한 교재나 기존의 시판되는 팬텀은 고가의 수입품이기에 다양한 종류의 팬텀을 갖추는 것이 어렵다. 3D 프린팅 기술을 활용해 일반 X선 촬영 실습용 팬텀을 더욱 저렴하고 간편하게 제작해 보고자 한다. CT 영상 데이터를 기반으로 제작한 골격 모형을 FDM(Fused Deposition Modeling) 방식의 3D printer를 이용해 출력한 골격 모형을 일반 X선 촬영 실습용 팬텀으로써 사용해 보고자 한다. 3D slicer 4.7.0 프로그램을 이용해 CT DICOM 영상 데이터를 STL 파일로 변환하고 G-code 변환 과정을 거쳐 3D 프린터로 출력하여 골격 모형을 제작한다. 완성된 팬텀을 X선 촬영, CT 촬영하여 실제 의료 영상, 시판되는 팬텀과 비교해 본 결과 실제 의료영상과 골 밀도 등의 세부적인 차이가 존재하였으나 실습용 팬텀으로써 활용할 수 있다고 판단되었다. 저가화되어 보급된 3D 프린터와 연구용으로 무료 배포된 3D slicer 프로그램을 활용하여 저렴하면서도 일반 X선 촬영 실습에 사용하는 것이 가능한 팬텀을 제작할 수 있었다. 앞으로의 3D 프린팅 기술의 다양화와 연구에 따라 보건 교육, 의료 서비스 등 여러 분야에 적용하는 것이 가능할 것이다.

Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality

  • Choi, Da-Hye;Choi, Bo-Ram;Choi, Jin-Woo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • 제43권1호
    • /
    • pp.7-15
    • /
    • 2013
  • Purpose: This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. Materials and Methods: The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phantom stand. The phantom stand had slits in four regions (incisor, premolar, molar, TMJ). Four raw images of the test phantom in each region and one raw image of the real skull were converted into 50 test phantom images and 50 skull phantom images with various line-pair values. 50 post-processed real skull phantom images were divided into 4 groups and were randomly submitted to 14 evaluators. Image quality was graded on a 4 point scale (1. good, 2. normal, 3. poor but interpretable, and 4. not interpretable). The reference line pair was determined as the first line-pair value scored less than 2 points. Result: The mean scores tended to decrease as the line-pair values increased. The reference line-pair values were 3.19 LP/mm in the incisor, 2.32 LP/mm in the premolar and TMJ, and 1.88 LP/mm in the molar region. Conclusion: Image quality evaluation methods and criteria should be able to assess various regions considering the characteristics of panoramic systems. This study suggested overall and regional reference line-pair values and established a set of standard values for them.

물팬톰에 조사된 고에너지 광자선의 선량 분포 특성에 관한 이론적 고찰 (The Theoretical Study of Absorbed Dose Distributions in Water Phantom Irradiated by High Energy Photon Beam)

  • 최동락;이명자
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.75-84
    • /
    • 1990
  • We have claculated the absorbed dose distributions in water phantom irradiated by high energy photon beam. PDD (Percent Depth Dose) and Beam Profile can be represented by functions of depths and distances by using one dimensional model model based on transport theory. The parameters on scattering and absorption are evaluated by using non-linear regression process method. The values neeessary for calculation are obtained by simple experiment. The calculated values are in good agreement with the measured values.

  • PDF

Phantom에서 Laser Induced Fluorescence의 스펙트라에 관한 연구 (A Study on Spectra of Laser Induced Fluorescence in Phantom)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.329-335
    • /
    • 1999
  • The influences of fluorophor, scatterer, and absorber in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength. The molecular properties have been studied by laser induced fluorescence spectroscopy in phantom. It has been found that the effects of optical properties in scattering media could be investigated by the optical parameters(${\mu}_a$, ${\mu}_a$, ${\mu}_t$). Experimental and Monte Carlo Simulation method for modelling light transport in tissue was applied. The experimental results using a phantom were discussed and compared with those obtained through Monte Carlo Simulation. It may also aid in designing the best model for oil chemistry, medicine and application of medical engineering.

A new phantom to evaluate the tissue dissolution ability of endodontic irrigants and activating devices

  • Kimia Khoshroo ;Brinda Shah;Alexander Johnson ;John Baeten ;Katherine Barry;Mohammadreza Tahriri ;Mohamed S. Ibrahim;Lobat Tayebi
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.45.1-45.8
    • /
    • 2020
  • Objective: The aim of this study was to introduce a gelatin/bovine serum albumin (BSA) tissue standard, which provides dissolution properties identical to those of biological tissues. Further, the study evaluated whether the utilization of endodontic activating devices led to enhanced phantom dissolution rates. Materials and Methods: Bovine pulp tissue was obtained to determine a benchmark of tissue dissolution. The surface area and mass of samples were held constant while the ratio of gelatin and BSA were varied, ranging from 7.5% to 10% gelatin and 5% BSA. Each sample was placed in an individual test tube that was filled with an appropriate sodium hypochlorite solution for 1, 3, and 5 minutes, and then removed from the solution, blotted dry, and weighed again. The remaining tissue was calculated as the percent of initial tissue to determine the tissue dissolution rate. A radiopaque agent (sodium diatrizoate) and a fluorescent dye (methylene blue) were added to the phantom to allow easy quantification of phantom dissolution in a canal block model when activated using ultrasonic (EndoUltra) or sonic (EndoActivator) energy. Results: The 9% gelatin + 5% BSA phantom showed statistically equivalent dissolution to bovine pulp tissue at all time intervals. Furthermore, the EndoUltra yielded significantly more phantom dissolution in the canal block than the EndoActivator or syringe irrigation. Conclusions: Our phantom is comparable to biological tissue in terms of tissue dissolution and could be utilized for in vitro tests due to its injectability and detectability.

혈관표면의 3차원 재구성을 위한 Deformable model의 정확성 검증에 관한 연구 (A Verification of the Accuracy of the Deformable Model in 3 Dimensional Vessel Surface Reconstruction)

  • 김호철;오장석;김형률;조성범;선경;김민기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.3-5
    • /
    • 2005
  • Vessel boundary detection and modeling is a difficult but a necessary task in analyzing the mechanics of inflammation and the structure of the microvasculature. In this paper we present a method of analyzing the structure by means of an active contour model(using GVF Snake) for vessel boundary detection and 3D reconstruction. For this purpose we used a virtual vessel model and produced a phantom model. From these phantom images we obtained the contours of the vessel by GVF Snake and then reconstructed a 3D structure by using the coordinates of snakes.

  • PDF

온라인 경매에의 카드깡 탐지요인에 대한 실증적 연구 (An Empirical Study on the Detection of Phantom Transaction in Online Auction)

  • 채명신;조형준;이병채
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2004년도 추계학술대회 및 정기총회
    • /
    • pp.68-98
    • /
    • 2004
  • Although the internet is useful for transferring information, Internet auction environments make fraud more attractive to offenders because the chance of detection and punishment are decreased. One of fraud is phantom transaction which is a colluding transaction by the buyer and seller to commit illegal discounting of credit card. They pretend to fulfill the transaction paid by credit card, without actual selling products, and the seller receives cash from credit card corporations. Then seller lends it out buyer with quite high interest rate whose credit score is so bad that he cannot borrow money from anywhere. The purpose of this study is to empirically investigate the factors to detect of the phantom transaction in online auction. Based up on the studies that explored behaviors of buyers and sellers in online auction, bidding numbers, bid increments, sellers' credit, auction length, and starting bids were suggested as independent variables. We developed an Internet-based data collection software agent and collect data on transactions of notebook computers each of which winning bid was over 1,000,000 won. Data analysis with logistic regression model revealed that starting bids, sellers' credit, and auction length were significant in detecting the phantom transaction.

  • PDF

온라인 경매에서의 신용카드 허위거래 탐지 요인에 대한 실증 연구 (An Empirical Study on the Detection of Phantom Transaction in Online Auction)

  • 채명신;조형준;이병태
    • 경영과학
    • /
    • 제21권2호
    • /
    • pp.273-289
    • /
    • 2004
  • Although the Internet is useful for transferring information, Internet auction environments make fraud more attractive to offenders, because the chance of detection and punishment is decreased. One of these frauds is the phantom transaction, which is a colluding transaction by the buyer and seller to commit the illegal discounting of a credit card. They pretend to fulfill the transaction paid by credit card, without actually selling products, and the seller receives cash from the credit card corporations. Then the seller lends it out with quite a high interest rate to the buyer, whose credit rating is so poor that he cannot borrow money from anywhere else. The purpose of this study is to empirically investigate the factors necessary to detect phantom transactions in an online auction. Based upon studies that have explored the behaviors of buyers and sellers in online auctions, the following have been suggested as independent variables: bidding numbers, bid increments, sellers' credit, auction lengths, and starting bids. In this study. we developed Internet-based data collection software and collected data on transactions of notebook computers, each of which had a winning bid of over W one million. Data analysis with a logistic regression model revealed that starting bids, sellers' credit, and auction length were significant in detecting the phantom transactions.

혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가 (Evaluation of Roadmap Image Quality by Parameter Change in Angiography)

  • 공창기;송종남;한재복
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2020
  • 이 연구의 목적은 Roadmap 영상에서 화질에 영향을 미치는 인자들을 알아보기 위한 것으로, 조영제의 희석률, Collimation Field, Flow Rate를 변화하여 연구를 하였다. 화질의 정량적인 평가를 위해, 아크릴를 이용하여 3mm 혈관모형의 Water Phantom을 자체 제작하였고, 자체 제작한 혈관모형의 Water Phantom으로 Roadmap 영상을 획득하고, SNR(Signal to Noise Ratio)과 CNR(Contrast to Noise Ratio)을 분석하였다. CM : N/S 희석률 변화에 대한 연구에서 CM : N/S 희석률을 (100%~10% : 100%)로 변화를 주었으며, 혈관모형 Water Phantom을 이용하여 촬영한 Roadmap 영상의 SNR과 CNR의 측정 결과 CM에 N/S 희석률이 높아질수록 SNR의 측정값이 점차적으로 낮아짐을 나타났고, CNR의 측정값도 점차적으로 낮아짐을 나타났다. 결론적으로 CM : N/S의 희석률이 높아질수록 SNR과 CNR 낮아짐을 확인하였고, CM : N/S의 희석률(100%~70 : 30%)에서 유의한 이미지를 얻을 수 있음을 확인하였다. Collimation Field 변화에 대한 연구에서 혈관모형 Water Phantom을 이용하여 Colimation Field를 혈관모형 중심으로 좌, 우 2 cm 간격으로 좁히면서 0 cm, 2 cm, 4 cm, 6 cm, 8 cm 10 cm, 12 cm으로 각각 변화를 주었으며, Roadmap을 촬영한 영상의 SNR과 CNR의 측정 결과는 Collimation Field를 혈관모형 중심으로 좁힐수록 SNR과 CNR의 측정값이 증가하는 것을 확인할 수 있었다. Flow rate 변화에 대한 연구에서 Autoinjector의 Volume을 15로 일정하게 하고, Flow Rate를 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 으로 각각 변화를 주었다. 혈관모형 Water Phantom을 이용하여 Roadmap 영상을 촬영한 이미지의 SNR과 CNR의 측정 결과 Flow Rate를 증가했을 때, SNR의 측정값이 점차적으로 감소하다가 Flow Rate 9~10에서 SNR의 측정값이 점차적 증가를 보였고, CNR의 측정값도 점차적으로 감소하다가 Flow Rate 9~10에서 CNR의 측정값이 점차적으로 증가를 보였다. 그러나 ROI Mean 값과 Background Mean 값으로 SNR과 CNR의 상관관계를 확인할 수 없었다. 상관관계를 확인하기 위해 Flow Rate 변화에 따른 Roadmap 연구는 향후 더 많은 연구로 확인해야 할 것으로 사료된다. 결론적으로 Roadmap 영상의 화질에 영향을 미치는 인자들을 알아보기 위해 조영제의 희석률, Collimation Field, Flow Rate 변화에 대한 연구에서 조영제에 N/S의 희석률이 증가할수록 SNR과 CNR이 낮아져 화질과 대조도가 낮아지는 것을 확인하였으며, Collimation Field를 좁힐수록 SNR과 CNR이 증가하여 화질과 대조도가 높아지는 것을 확인하였다. 그러나 Flow Rate 변화에 대한 연구에서는 상관관계를 확인할 수 없었다. 검사 및 시술을 할 때 신장의 영향을 최소화하기 위해 적절한 조영제 농도 선택과 대조도 향상 및 피폭 감소를 위한 적절한 Collimation Field를 사용하는 것이 유용할 것으로 판단된다.