Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality |
Choi, Da-Hye
(Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University)
Choi, Bo-Ram (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) Choi, Jin-Woo (Department of Oral and Maxillofacial Radiology, College of Dentistry, Dankook University) Huh, Kyung-Hoe (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) Yi, Won-Jin (Department of Oral and Maxillofacial Radiology, BK21 Craniomaxillofacial Life Science, and Dental Research Institute, School of Dentistry, Seoul National University) Heo, Min-Suk (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) Choi, Soon-Chul (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) Lee, Sam-Sun (Department of Oral and Maxillofacial Radiology, BK21 Craniomaxillofacial Life Science, and Dental Research Institute, School of Dentistry, Seoul National University) |
1 | Raberin M, Laumon B, Martin JL, Brunner F. Dimensions and form of dental arches in subjects with normal occlusions. Am J Orthod Dentofacial Orthod 1993; 104 : 67-72. DOI ScienceOn |
2 | DIN German Institute for Standardization. DIN 6868-151. Image quality assurance in diagnostic X-ray departments - Part 151: acceptance testing of dental radiographic equipment accordance to RoV - Rules for the inspection of image quality after installation, maintenance and modification. Berlin: DIN Deutsches Institut für Normung e. V.; 2010. |
3 | Yoo S, Kim GY, Hammoud R, Elder E, Pawlicki T, Guan H, et al. A quality assurance program for the on-board imagers. Med Phys 2006; 33 : 4431-47. DOI ScienceOn |
4 | Enforcement regulations of the installation and operation of special medical equipments. Enforcement regulation No.65 of Ministry of Health and Welfare, 2003. |
5 | Lee SH, Choe YH, Chung SY, Kim MH, Kim EK, Oh KK, et al. Establishment of quality assessment standard for mammographic equipments: evaluation of phantom and clinical images. J Korean Radiol Soc 2005; 53 : 117-27. DOI |
6 | Korean Institute for Accreditation of Medical Imaging [internet]. Table for mammographic quality control. Available from: http:// www.ikiami.or.kr/Data/KMI501QD.aspx. |
7 | Kin HJ, Lee HG, Jeong JB, Im CI, Son HK. A study on guidance for medical radiation safety. Final report. Seoul: Korea Food and Drug Administration; 2010. Report No.: 10171Radiology |
8 | White SC, Pharoah MJ. Oral Radiology: principles and interpretation. 6th ed. St. Louis: Mosby-Year Book Inc; 2009. |
9 | Gopal A, Samant SS. Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics. Med Phys 2009; 36 : 2006-15. DOI ScienceOn |
![]() |