• Title/Summary/Keyword: periodontal parameter

Search Result 21, Processing Time 0.025 seconds

THE STUDY ON THE EFFECTS OF THE INSULIN-LIKE GROWTH FACTOR-I ON THE BIOLOGICAL ACTIVITY OF THE HUMAN PERIODONTAL LIGAMENT CELLS (Insulin-like growth factor-I 이 치주인대세포의 생물학적 활성도에 미치는 영향에 대한 연구)

  • Kim, Seong-Jin;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.2
    • /
    • pp.219-237
    • /
    • 1994
  • The ultimate goal of clinical periodontal therapy is to achieve regeneration of a healthy connective tissue reattachment. Conventional therapy including scaling, root planing, gingival curettage, gingivectomy and flap procedures of various types results primarily in repair rather than regeneration of the periodontium. In order for periodontal regeneration to occur, progenitor periodontal ligament cells must migrate to the denuded root surface, attach to it, proliferate and mature into an organized and functional fibrous attachment apparatus. Polypeptide growth factors belong to a class of potent biologic mediators which regulate cell differentiation, proliferation, migration and metabolism. Insulin-like growth factor-I (IGF- I ) of these factors appear to have an important role in periodontal wound healing and bone formation. The purpose of this study is to evaluate the effects of IGF- I on the periodontal ligament cells to use as a regeneration promoting agent of periodontal tissue. Human periodontal ligament cells were obtained from periodontal tissue explants culture of the first premolar tooth extracted for the orthodontic treatment. Cells were cultured in Dulbecco's modified Eagle medium(DMEM) with 10% fetal bovine serum. Fourth to seventh passage cells were plated in 24 well tissue culture plates and medium changed to serum-free medium prior to addition of growth factors. Cell proliferation was measured by the incorporation of $[^3H]-thymidine$ into DNA, Protein synthesis was determined by measurement of $[^3H]-proline$ incorporation into collagenase-digestible protein(CDP) and noncollagenous protein(NCP) according to the method of Peterkofsky and Diegelmann (1971), And alkaline phosphatase activity was measured as one parameter of osteoblastic differentiation. The results were as follows : The DNA synthetic activity was increased in a dose-dependent manner with IGF- I except for 0.1ng/ml concentration of IGF- I At the concentration of 10, 100ng/ml, IGF- I significantly increased the DNA synthetic activity(P<0.05) The total protein, collagen and noncollagen synthesis was increased in a dose-dependent manner with IGF- I except for 0.1ng/ml concentration of IGF- I. At the concentration of 1, 10, 100ng/ml, IGF- I significantly increased the total protein, collagen and noncollagen synthesis activity(P<0.95, P<0.001). The % of collagen was not effected according to the concentration of IGF- I. The alkaline phosphatase activity was increased in a dose-, time-dependent manner with IGF- I (10, 100ng/ml). In conclusions, the present study shows that IGF- I has a potentiality to enhance the DNA synthesis of periodontal ligament cells with including the increase of the total protein and collagen synthetic activity. The use of IGF- I to mediate biological stimulation of periodontal ligament cells shows promise for future therapeutic applications.

  • PDF

$BBPY^{(R)}$ graft for periodontal intrabony defects and molar furcation lesions: Case Report (다양한 치주 골내낭과 이개부 병변의 처치를 위한 $BBP^{(R)}$ 이식재의 임상적 효과)

  • Kim, Myung-Jin;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.1
    • /
    • pp.97-102
    • /
    • 2008
  • Purpose: Periodontal intrabony defects have great deal of importance since they contribute to the development of periodontal disease. Current treatment regimens for intrabony defects involve grafting of numerous bony materials, GTR using biocompatible barriers, and biomodification of root surface that will encourage the attachment of connective tissue. Xenograft using deproteinized bovine bone particles seems to be very convenient to adjust because it doesn't require any donor sites or imply the danger of cross infections. These particles are similar to human cancellous bone in structure and turned out to be effective in bone regeneration in vivo. We here represent the effectiveness of grafting deproteinized bovine bone particles in intrabony defect and furcation involvements that have various numbers of bony walls. Materials and methods: Open flap debridement was done to remove all root accretions and granulation tissue from the defects within persisting intrabony lesions demonstrating attachment loss of over 6mm even 3 months after nonsurgical periodontal therapy have been completed. Deproteinized bovine bone particles($BBP^{(R)}$, Oscotec, Seoul) was grafted in intrabony defects to encourage bone regeneration. Patients were instructed of mouthrinses with chlorohexidine-digluconate twice a day and to take antibiotics 2-3 times a day for 2 weeks. They were check-up regularly for oral hygiene performance and further development of disease. Probing depth, level of attachment and mobility were measured at baseline and 6 months after the surgery. The radiographic evidence of bone regenerations were also monitored at least for 6 months. Conclusion: In most cases, radio-opacities increased after 6 months. 2- and 3-wall defects showed greater improvements in pocket depth reduction when compared to 1-wall defects. Class I & II furcation involvements in mandibular molars demonstrated the similar results with acceptable pocket depth both horizontally and vertically comparable to other intrabony defects. Exact amount of bone gain could not be measured as the re-entry procedure has not been available. With in the limited data based on our clinical parameter to measure pocket depth reduction following $BBP^{(R)}$ grafts, it was comparable to the results observed following other regeneration techniques such as GTR.

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Root Substitute Removal in Vitro (큐렛형 팁을 장착한 압전방식 초음파 치석제거기가 치근대체물 삭제에 미치는 영향)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.429-442
    • /
    • 2000
  • Based on current evidence in the literature, it is known that endotoxin is a weakly adherent surface phenomenon and that power-driven instruments can be used to accomplish definitive root detoxification and maximal wound healing without overinstrumentation of root and without extensive cementum removal. And one of the newly developed curette tips used with low power of piezoelectric ultrasonic scaler, is effective to remove calculus and not to remove the excessive cementum. The purpose of this study is therefore, to assess the influence of ultrasonic power and various working parameters on root substitute removal when instrumentation is performed with the curette tip on piezoelectric ultrasonic scaler. This study assessed defect depth, width and area resulting from instrumentation using a piezoelectric ultrasonic scaler with a curette type tip in vitro to acrylic resin block as a root substitute. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1 N, 2 N) and instrumentation time(5 sec, 10 sec, 20 sec) and power setting was adjusted 0,2,4,8 in P mode. Power setting had the greatest influence on defect depth compared to lateral force and instrumentation time(standardized regression parameter estimates${\pm}$standard error, $0.37{\pm}0.02$, $0.19{\pm}0.02$, $0.07{\pm}0.02$). The effects on defect area also greatest for power setting($0.57{\pm}0.03$) compared to lateral force and instrumentation time($0.33{\pm}0.03$, $0.12{\pm}0.03$). The effect of the power setting on the defect width($0.15{\pm}0.01$) is not so great as defect depth or defect area compared to lateral force($0.12{\pm}0.01$) and effect of instrumentation time is minimal($0.02{\pm}0.01$). It could be concluded that the power setting has the greatest influence on the defect depth and area in curette type tip with low power of piezoelectric ultrasonic device. Many parameters can be adjusted in various situation in clinical use of piezoelectric ultrasonic scaler but the power setting is the first parameter to be adjusted.

  • PDF

THE CHANGE OF INTERPROXIMAL BONE DENSITY ASSESSED BY VIDEODENSITOMETER AFTER SUBGINGIVAL CURETTAGE (Videodensitometer를 이용한 치은연한소파술후 치간골 골밀도의 변화)

  • Choi, Jin-Keun;Lee, Man-Sup;Kwon, Young-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.397-406
    • /
    • 1995
  • The purpose of this study was to evaluate the changes of interproximal bone density by means of videodensitometer and to examine the clinical applicability of videodentitometer to assess the periodontal disease activity.Twelve interproximal sites, with periodontal pockets deeper than 5mm and vertical loss of bone on standard dental radiograph, were treated by subgingival curettage. The papilla bleeding index, the plaque index, the degree of mobility, the depth of pockets, and the level of attachment were measured. Standardized reproducible radiographs were taken by using the occlusal stent with parallelling film holder. The density of the interdental bone was measured on the radiographs by a videodensitometer at three levels: the most 'superficial' level; the 'deep' level, arbitrarily 1.5mm below: and the 'apical' level, where no bony changes were to be expected. The clinical parameter and the radiographical change were measured at initial, and 1 month, 3 months, and 6 months after treatment.The results were as follows :1. The papilla bleeding index and the degree of mobility decreased significantly until 3 months after subgingival curettage and showed the Same level in the remaining experimental periods. 2. The pocket depth mainly decreased due to the gingival recession until 1 month after treatment, but to the attachment gain after 1 month. 3. The density of the interdental bone did not show a significance increase until 1 month after treatment, but showed a steady increase throughout the 6 months of observation. 4. The close relationships were shown between the decrease in pocket depth and the gain of attachment and the improvement of bone density at 6 months after treatment.

  • PDF

Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study

  • Kim, Seok-Gyu;Yun, Pil-Young;Park, Hyun-Sik;Shim, June-Sung;Hwang, Jung-Won;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.18-23
    • /
    • 2012
  • PURPOSE. The purpose of this prospective study was to evaluate the effect of early loading on survival rate or clinical parameter of anodic oxidized implants during the 12- month postloading period. MATERIALS AND METHODS. Total 69 implants were placed in 42 patients. Anodic oxidized implants (GS II, Osstem Cor., Busan, Korea) placed on the posterior mandibles were divided into two groups, according to their prosthetic loading times: test group (2 to 6 weeks), and control group (3 to 4 months). The implant survival rates were determined during oneyear postloading period and analyzed by Kaplan-Meier method. The radiographic peri-implant bone loss and periodontal parameters were also evaluated and statistically analyzed by unpaired t-test. RESULTS. Total 69 implants were placed in 42 patients. The cumulative postloading implant survival rates were 88.89% in test group, compared to 100% in control group (P<.05). Periimplant marginal bone loss (T: $0.27{\pm}0.54$ mm, C: $0.40{\pm}0.55$ mm) and periodontal parameters showed no significant difference between the groups (P>.05). CONCLUSION. Within the limitation of the present study, implant survival was affected by early loading on the anodic oxidized implants placed on posterior mandibles during one-year follow-up. Early implant loading did not influence peri-implant marginal bone loss, and periodontal parameters.

The Effects of Nd:YAG Laser Irradiation on the Root Surface;A Scanning Electron Microscopic Study (Nd:YAG 레이저 조사시 치근면에 미치는 효과에 관한 주사전자현미경적 연구)

  • Lee, Su-Jeong;Kim, Soo-Ah;Seo, Seok-Ran;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.495-514
    • /
    • 1997
  • The purpose of this study was to evaluate the in vitro effects of Nd:YAG laser irradiation on removal of a root surface smear layer after root planing in comparison with Tetracycline HCl. The 60 extracted human teeth due to severe periodontal disease were vigorously scaled and root planed with Gracey curet. Thirty specimen($5{\times}5{\times}2mm$) were obtained from root planed surface of 30 human teeth and assigned randomly to one of three groups : root planed group(5 specimen), Tetracycline HCI group(5 specimen, burnished for 5 minutes), and Nd:YAG laser group(25 specimen, German Dental Laser, Fotona Twinlight). Nd:YAG laser group was divided into 4 subgroups according to power of 1W, 1.5W, 2W, 3W at frequency to 10Hz. The specimen were then fixed, and examed by Scanning electron microscopic study. 30 of 60 human teeth used to measurement of the intrapulpal temperature rise during laser irradiation. Laser-irradiated surface exhibited various surface texture from relative flat surface to irregular surface with patent dentinal tubules of various shape and size. In some area, the root surface alteration which are carbonization, pit and crater formation and melting and resolidification were observed. The number of exposed dentinal tubules per unit($100_{\mu}m^2$) on tetracycline HCI group was more than that in the laser group below 1.5W of power(150mJ/pulse) and was significantly less than that in laser group above 2W of power(200mJ/pulse)(P<0.OOl). As power increased the intrapulpal temperature rise also increased. The result suggested that the parameter which effectively remove root surface smear layer than tetracycline HCI may cause thermal damage to pulp and root surface alteration result from laser exposure would indicate need for additional instrumentation. Thus, Nd:YAG laser irradiation in these parameter may not be appropriate for clinical use as adjunct to conventional periodontal therapy.

  • PDF

The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error (중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구)

  • Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF

The study of the peri-inplant soft tissue around osseointegrated implants in partial edentulous patients (하악 부분 무치악 환자의 골유착성 임플랜트 주위 연조직에 관한 연구)

  • Jung, Keun-Sik;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.561-573
    • /
    • 1997
  • The keratinized mucosa around the implant is an important key in health of soft tissue and hard tissue. The purpose of this study is showed that the keratinized mucosa is associated with the keratinized mucosa index, plaque index, gingival index, probing depth. which is investigated to observing the peri-implant mucosa of mandibular partial edentulous patuent using periodontal parameter by previously published paper. It was estimated 6 site with regard to 80 fixture for 28 person, and the average age is 46.8. Each estimation is the order of less trauma, that is, plaque index, keratinized mucosa index, gingival index and probing depth. In this study, statstically analyzed treatment is used for Spss V 7.0 for Windows(Spss Inc, USA). The Kruskal Walis Test is used to compare the amount of the keratinized mucosa is into the $0{\sim}3$ index, with plaque index, gingival index and probing depth. Mann-whitney Test is used to interpreate the relation of plaque index and probing depth, which is showed significant difference. The Result are as follows 1. The kertinized mucosa index 3 amounts to 47.7%, which is much higher than the other indices and the index order is followed 3, 1, 2 and O. 2. The plaque index 1 amounts to 61.7%, which is much higher than the other indices and the index order is followed 1, 2, 3 and O. The plaque index 0 is significant to each of index(P<0.05). The plaque index is decrease as the keratinized mucosa index is increased. 3. The probing depth for 2mm, 1mm, 3mm is 48.9%, 23.5%, 16.8% respectively, which is most occupied. The probing depth 2mm and 3mm for the keratinized mucosa index is significant(P<0.05). The probing index is decreased as the keratinized mucosa index is increased. 4. The gingival index 0 amounts to 58.0%, which is much higher than the other indices and the index order is followed 0, 1, 2 and 3.

  • PDF

Analysis of the priority of anatomic structures according to the diagnostic task in cone-beam computed tomographic images

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.46 no.4
    • /
    • pp.245-249
    • /
    • 2016
  • Purpose: This study was designed to evaluate differences in the required visibility of anatomic structures according to the diagnostic tasks of implant planning and periapical diagnosis. Materials and Methods: Images of a real skull phantom were acquired under 24 combinations of different exposure conditions in a cone-beam computed tomography scanner (60, 70, 80, 90, 100, and 110 kV and 4, 6, 8, and 10 mA). Five radiologists evaluated the visibility of anatomic structures and the image quality for diagnostic tasks using a 6-point scale. results: The visibility of the periodontal ligament space showed the closest association with the ability to use an image for periapical diagnosis in both jaws. The visibility of the sinus floor and canal wall showed the closest association with the ability to use an image for implant planning. Variations in tube voltage were associated with significant differences in image quality for all diagnostic tasks. However, tube current did not show significant associations with the ability to use an image for implant planning. conclusion: The required visibility of anatomic structures varied depending on the diagnostic task. Tube voltage was a more important exposure parameter for image quality than tube current. Different settings should be used for optimization and image quality evaluation depending on the diagnostic task.

Clinical study of guided bone regeneration of extracted socket with PLA/PGA membrane and silk fibroin membrane (PLA/PGA 차폐막과 실크 피브로인 차폐막을 이용한 발치와의 골유도재생술의 비교연구)

  • Hwang, Woo-Jin;Jeong, Seong-Nyum;Kim, Yun-Sang;Pi, Sung-Hee;You, Hyung-Keun;Chung, Chong-Pyoung;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.129-138
    • /
    • 2009
  • Purpose: This study was designed to compare the bond regeneratiom effects of treatment using silk fibroin membrane ( Nanogide-S$^{(R)}$ ) resorbable barrier with control group treated by polyactic acid / polylacticglycolic acid membrane(Biomesh$^{(R)}$ ) Methods: 44 severe bone loss on extraction socket from 44 patients were used in this study. In experimental group 22 sites of them were treated by silk fibrin membrane as and the other 22 sites were treated by polyactic acid/ polylacticglycolic acid membrane as a control group. Clinical parameters including recovered bone width, length and radiographic parameter of vertical length were evlauated at base line and 3 months after surgery. Results: 1) Severe bone width, length was significantlly decreased in two group. 2) Bone width, length was significantlly decreased in two group. 3) Decreased bone width, length and radiographic examination differences between group. Conclusions: On the basis of these results, silk fibrin resorbable membrane has similar bone regeneration ability to polyactic acid / polylacticglycolic acid membrane in guided bone regeneration for severe bone loss defect on extraction socket.