• Title/Summary/Keyword: performance standards

Search Result 2,377, Processing Time 0.03 seconds

International Comparison of Performance Verbs included in Achievement Standards of Mathematics Curriculum: Focusing on South Korea, the United States, the United Kingdom, and Australia (수학과 교육과정 성취기준에 포함된 수행 동사 국제 비교: 한국, 미국, 영국, 호주의 수학과 교육과정을 중심으로)

  • Kwon, Jeom-Rae;Jung, Hye-Yun;Jung, Soo-Yong
    • Communications of Mathematical Education
    • /
    • v.37 no.2
    • /
    • pp.105-134
    • /
    • 2023
  • The purpose of this study is to explore which performance verbs are used in the achievement standards of the Korean mathematics curriculum and how to improve them. So, first, we analyzed whether there were differences in the performance verbs included in the 2015 revised mathematics curriculum achievement standards by school level. In addition, it was analyzed whether there were differences in the performance verbs included in the mathematics curriculum in Korea and foreign countries. As a result of the analysis, both the frequency and the type of performance verbs included in the achievement standards of the Korean mathematics curriculum decreased as the school level increased. Also, performative verbs such as 'understand' and 'know' were excessively used. Similar tendencies were seen in foreign mathematics curricula, but the frequency and the type of performance verbs were higher than those in Korea, and various performance verbs were used. As a result of the study, it is suggested that performance verbs included in achievement standards need to be improved to improve middle and high school mathematics classes.

The Reformation of Gas Technical Standards System

  • Hur, Young-Taeg;Lim, Ha-Kyung;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.20-23
    • /
    • 2008
  • The current gas regulations have been reformed into a new technical standards system called as "KGS (Korea Gas Safety) Code" system. Korea Gas Safety Corporation has developed a new framework of technical standards classification method and will manage the new technical standards system in compliance with the mandatory requirements of gas regulations. This study will cover an overall view of the reformation and show "KGS Code" in detail.

  • PDF

A Study on the Building Energy Efficiency Rating Changes by Enhanced Thermal Insulation Performance of Building Envelope Standards in Apartment Houses (공동주택에서 외피단열성능기준 강화에 따른 건축물에너지 효율등급 변화에 관한 연구)

  • Cho, Yeong Uk;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • This study aimed to compare the primary heating energy consumption of regional apartment houses based on the enhanced thermal insulation performance of building envelope standards. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the southern region, the largest regional difference in primary heating energy consumption, is $10.3kWh/(m^2{\cdot}year)$. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the central region is $8.0{\sim}8.5kWh/(m^2{\cdot}year)$ and that of the Jeju region is $0.5kWh/(m^2{\cdot}year)$. These energy consumption differences do not result in building energy efficiency ratings changing. The building energy efficiency ratings have the possibility to be changed.

An Analysis and Evaluation of Fire Resistance Performance for the Protected Steel Columns in Korea (국내 피복 철골기둥의 내화 성능 분석 및 평가)

  • Shin, Tae Song
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.27-35
    • /
    • 2009
  • Main structural steel members need fire-resistance measures to ensure their fire-resistance performance for a prescribed time. This paper analyzes and evaluates the fire-resistance performance of approved Korean fire-protection products for steel columns. These products are classified into products for board protection and for spray protection, samples of which were selected for the analysis. The fire-resistance performance was analyzed on the basis of Korean and European standards. The Korean standards are considered additional to the Euro-code standards for performance design. The Korean standards generally take more precautions to ensure safety on the temperature side, but require the reflection of material properties, the steel temperature calculation methodology, the profile factor, and the strength verification in a fire.

A Study on Constructing the Requirement Management System of the Performance Tests and Safety Standards of the High Speed Railway using Model-Based Systems Engineering Approach (모델기반 시스템엔지니어링 접근을 통한 고속철도 성능시험 및 안전기준 요구사항 관리체계 구축에 관한 연구)

  • Choi Yo-Chul;Park Young-Won;Wang Jong-Bae
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.3 s.34
    • /
    • pp.330-334
    • /
    • 2006
  • To maintain design-knowledge database and manage configuration for requirement of performance tests and safety standards of High Speed Railway(HSR), It is established that management system of performance tests and safety standards and then constructed that design-knowledge database and documented a performance test and safety specifications for supporting performance test and safety system using Model-Based Systems Engineering(MBSE) tool.

Evaluation criteria for filling performance of high-flowing concrete using steel-concrete panel

  • Dong Kyu Lee;Jae Seon Kim;Myoung Sung Choi
    • Advances in concrete construction
    • /
    • v.16 no.5
    • /
    • pp.231-241
    • /
    • 2023
  • The purpose of this study was to evaluate the practical application of high-flowing concrete for a steel-concrete panel (SCP) module for a liquefied natural gas (LNG) storage tank. We evaluated the physical properties and filling performance of the developed concrete for the SCP module. First, slump tests were performed to evaluate the performance of the proposed standards for the filling tests. All the concrete mixes showed satisfactory performance. Based on the results of the previous study, the reliability of the required time measured using the T500 test and the rheometer results measured before and after pumping was 0.94, indicating that segregation and blocking should not occur. L-box and U-box tests were conducted before and after pumping. All the recommended standards showed satisfactory performance. The SCP structural module for LNG storage tanks was fabricated to a full scale to evaluate its practical application at the final site. Satisfactory filling performance was confirmed for all the specimens.

Performance Estimation of KPST to GPS Time Offset for GNSS Interoperability to Increase Navigational Performance

  • Lee, Young Kyu;Yang, Sung-hoon;Lee, Ho Seong;Lee, Jong Koo;Hwang, Sang-wook;Rhee, Joon Hyo;Lee, Ju Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.3
    • /
    • pp.191-198
    • /
    • 2022
  • In order to increase the practical use and navigational application performance of the Korean Positioning System (KPS), it is required to provide interoperability with other Global Navigation Satellite System (GNSS). This kind of interoperability can be obtained by broadcasting the time offset between KPS and GNSS using a KPS navigation message. With the assumption that KPS Time (KPST) will be generated by the similar method and equipment of UTC(KRIS), the overall behavior of KPST will be close to that of UTC(KRIS). Therefore, the time offset between KPST and GPS Time (GPST) is estimated by using UTC(KRIS) instead of KPST because KPST can not available at the present time. In this paper, we describe the estimation results of the KPS to GPS Time Offset (KGTO) obtained by using a GNSS time transfer receiver which reference inputs are fed from UTC(KRIS). The estimated KGTO performance is compared to the time offset between UTC(KRIS) and UTC(USNO) which is used to generate GPST and considered as the real GPST. The time offset between UTC(KRIS) and UTC(USNO) is obtained by using the Bureau International des Poids et Mesures (BIPM) Circular T report. From the results, it is observed that KGTO can be estimated under 10 ns with the assumption that KPST will be generated by a similar method of UTC(KRIS) generation.

Performance Evaluation of Korean Power System for Developing the Planning Standards (계통계획기준 수립을 위한 한전계통의 성능평가)

  • Kook, Kyung-Soo;Oh, Tae-Kyoo;Kim, Tai-Hyun;Kim, Hak-Man;Bang, Min-Jae;Lee, B.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.203-205
    • /
    • 2001
  • This paper is part of an ongoing project of KEPCO; 'A Study on Criteria and Standards for Transmission System Planning', The objective of this project is to develop the standards and procedures for transmission system planning. This involves reviewing published literatures, other documents of existing criteria and procedures, and various case studies of advanced countries which are already under the competitive electricity industry. This paper presents the result of evaluating Korean Power System as a pre-study for developing the Planning Standards of Korean Power System. For this, WSCC/NERC's performance criteria for planning transmission system, and KEPCO's 'Long Term Transmission System Planning Criteria' are considered. By doing this, the level of performance criteria which should be applied to Korean Power System and the detailed procedures which would be used in system test were reviewed.

  • PDF

Comparative Analysis of Korean Universities' Journal Publication Research Performance Evaluation Standards (국내대학의 학술논문 연구업적평가기준 비교 분석)

  • Lee, Hye-Kyung;Yang, Kiduk
    • Journal of Korean Library and Information Science Society
    • /
    • v.48 no.2
    • /
    • pp.295-322
    • /
    • 2017
  • As a first step in developing a more effective and robust approach to faculty research performance assessment, this study analyzed the existing faculty research assessment methods by comparing Korean universities' research evaluation standards, National Research Foundation of Korea's (KRF) standard for assessing research proposals, and various bibliometric measures. The study data included research evaluation standards of KRF along with 27 Korean universities with Library and Information Science (LIS) department, and the publication data of 183 LIS faculties in Korean universities from 2001 to 2015, which consisted of 3,863 papers 16,978 citations. After the comparative analysis of research evaluation standards, the study examined the rankings of institutions and faculty produced by applying the collected standards and bibliometric metrics to the publication data. The study showed that Korean university standards for research evaluation, which aim to consider both productivity and impact of faculty research, differ from similar bibliometric measures such as h-index, and the difference could significantly impact the assessment of faculty research performance.