• Title/Summary/Keyword: performance reduction characteristics

Search Result 1,222, Processing Time 0.026 seconds

Aerodynamic performance evaluation of different cable-stayed bridges with composite decks

  • Zhou, Rui;Ge, Yaojun;Yang, Yongxin;Du, Yanliang;Zhang, Lihai
    • Steel and Composite Structures
    • /
    • v.34 no.5
    • /
    • pp.699-713
    • /
    • 2020
  • The aerodynamic performance of long-span cable-stayed bridges is much dependent on its geometrical configuration and countermeasure strategies. In present study, the aerodynamic performance of three composite cable-stayed bridges with different tower configurations and passive aerodynamic countermeasure strategies is systematically investigated by conducting a series of wind tunnel tests in conjunction with theoretical analysis. The structural characteristics of three composite bridges were firstly introduced, and then their stationary aerodynamic performance and wind-vibration performance (i.e., flutter performance, VIV performance and buffeting responses) were analyzed, respectively. The results show that the bridge with three symmetric towers (i.e., Bridge I) has the lowest natural frequencies among the three bridges, while the bridge with two symmetric towers (i.e., Bridge II) has the highest natural frequencies. Furthermore, the Bridge II has better stationary aerodynamic performance compared to two other bridges due to its relatively large drag force and lift moment coefficients, and the improvement in stationary aerodynamic performance resulting from the application of different countermeasures is limited. In contrast, it demonstrates that the application of both downward vertical central stabilizers (UDVCS) and horizontal guide plates (HGP) could potentially significantly improve the flutter and vortex-induced vibration (VIV) performance of the bridge with two asymmetric towers (i.e., Bridge III), while the combination of vertical interquartile stabilizers (VIS) and airflow-depressing boards (ADB) has the capacity of improving the VIV performance of Bridge II.

Transmitted Noise Reduction of Piezoelectric Smart Panels using Passive/Active Method in Wide Range frequency (수동/능동적 방법을 혼용한 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;박우철
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.73-79
    • /
    • 2001
  • In this paper, the transmitted noise reduction performance of piezoelectric smart panels is experimentally studied. The proposed piezoelectric smart panels are comprised of plate structure on which piezoelectric sensor/actuators are bonded and sound absorbing material is provided. It is a combination of passive and active approaches utilizing a passive effect at high frequencies and an active effect at low frequencies. To prove the concept of piezoelectric smart panels, an acoustic measurement experiment is performed. An acoustic tunnel is designed and its acoustic characteristics are tested. Below 800Hz, the tunnel exhibits a plane wave guide characteristics. When an absorbing material is bonded on a single plate, a remarkable transmitted noise reduction in mid frequency range is observed except the first resonance frequency. By enabling the active control of single smart panel with negative feedback control. about 10dB noise reduction is achieved at the resonance frequencies. The double smart panel got 4dB at the first resonance frequency and has more potential to reduce the transmitted noise in a wide range frequency. Piezoelectric smart panels incorporating passive absorbing material and active piezoelectric devices is a promising technology for noise reduction in a wide range frequency.

  • PDF

Shrinkage and Durability Characteristics of Latex Modified Repair Mortar for Agricultural Concrete Structures (농업용 콘크리트 구조물용 라텍스개질 보수용 모르타르의 수축 및 내구성능 평가)

  • Won, Jong-Pil;Lee, Jae-Young;Park, Chan-Gi;Park, Seong-Gi;Kim, Wan-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.5
    • /
    • pp.23-30
    • /
    • 2007
  • This research was to evaluate the shrinkage and durability performance of latex modified repair mortar and to improve the service lift of the agricultural concrete structures. The shrinkage characteristics of the repair material creates the delamination of repair materials and existing concrete. It may reduce the service life of structures. Also the reduction of durability performance of the repair materials induces the destruction of the repaired concrete structures at early stage. In this research, plastic and drying shrinkage, thermal expansion coefficient for shrinkage properties, durability performance, permeability, repeated freezing and thawing, and resistance of chemical solution test were performed. Test results showed that the latex modified repair mortar indicated the shrinkage amount which the delamination does not happen, and the latex modified repair mortar appeared excellent long-term durability performance which can increase the service life.

Internal Marketing Approach to Internal Satisfaction, Loyalty and Organization Performance : Using Logistics Regression (내부마케팅이 직무만족, 애호도, 기업성과에 미치는 영향 : 로지스틱회귀분석 방법을 이용)

  • Son, Hee-Young;Kang, Man-Su;Park, Sang-Kyu
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.39 no.3
    • /
    • pp.117-131
    • /
    • 2014
  • As interests in the management of government-owned corporation rise, in these days, debt reduction and normalization of management of those companies have been proceeding under the lead of government. At this point, it is very important to seek internal marketing method for improvement of internal employees' satisfaction, loyalty and organization performance. This study analyzes impact of factors of internal marketing effect on organization satisfaction, loyalty and organization performance in the context of the domestic public companies, the Korea Electric Power Corporation (KEPCO) and the Korea Water Resources Corporation (K-WATER)'s employees empirically. There are some significant differences between the two publics. It is proved that delegation of the authority influences on internal satisfaction and organization performance in the case of KEPCO, and education and training influence on internal satisfaction and organization performance in the case of K-WATER. On the other hand, in the case of K-WATER, any internal marketing factors don't influence on loyalty. The results of this study show somewhat different characteristics depending on the characteristics of firm, however, it is expected that this study can be very useful in regards to similar public enterprises or businesses.

A Performance characteristics of Pt/C Electrode prepared by Hot Pressing Method (Hot Pressing법에 의해 제조된 Pt/C 전극의 성능특성)

  • 김진수;서동우;설용건;이태희
    • Journal of Energy Engineering
    • /
    • v.1 no.1
    • /
    • pp.58-65
    • /
    • 1992
  • Pt loaded porous carbon Pt/C electrode was prepared by hot pressing process to enhance the electrode performance in PAFC (phosphoric acid fuel cell). By changing the hot pressing conditions and PTFE contents, Pt/C electrodes were prepared and the electrochemical characteristics of oxygen reduction and unit-cell performance were evaluated. The optimum condition of hot press to make electrode is 360$^{\circ}C$ and 10 kg/$\textrm{cm}^2$. Maximum performance was obtained at 30 wt% PTFE content in the catalyst layer with 80% utilization of platinum clusters. Unit-cell performance of hot pressed Pt/C electrode was 200 mA/$\textrm{cm}^2$ at 700 ㎷ and stable performance was maintained more than 200 hr.

  • PDF

Performance Improvement of Air Conditioner Network System using Wireless Sensors Through System Performance Index and Dynamic Power Distribution Control (시스템 성능 지수 및 동적 전력분산 제어를 통한 무선센서를 이용한 에어컨 네트워크 시스템의 성능 개선)

  • Choi, Ho-seek;Kwon, Woo-hyen;Yoon, Byung-keun
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.64-70
    • /
    • 2019
  • Wireless sensors have been developed in numerous ways for enhancing the convenience of installation, management and maintenance of sensors. Energy harvesting wireless sensors, which can collect energy from the external environment for permanent usage without the need of recharging and exchanging batteries, have been developed and employed used in Internet of Things and at various industrial sites. Energy harvesting wireless sensors are significantly affected by the sensor lifespan to sudden variation in the external environment. Furthermore, reduction in the sensor operating timespan can greatly affect the characteristics of the devices connected through a network. In this paper, a system performance index is proposed that can comprehensively evaluate the lifespan of a solar cell wireless sensor, determine the characteristics of devices connected to the associated network, and recommend dynamic power distribution control for improving the system performance index. Improvement in the system performance index was verified by applying the proposed dynamic power distribution control to an air conditioner network system using a solar cell wireless sensor. Obtained results corroborate that the dynamic power distribution control can extend the lifespan of the incorporated wireless sensor and reduce the air conditioner's power consumption.

A Study on Treatment Characteristics of the Phenol and Catechol using on Anaerobic Fluidized Bed Reactor (혐기성 유동층 반응기를 이용한 페놀과 카테콜의 처리특성에 관한 연구)

  • 김민수;박동일;홍종순;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • This study was carried to investigate the treatment characteristics of the phenol and catechol with an anaerobic fluidized bed reactor(AFBR) having a dimension of 9 cm i.d. and 1.25 m height. The reactor was operated at $35\pm 1\circ$C. The COD concentration of the effluent, the gas production rate and the composition of gas were measured to determine the performance of the AFBR as the hydraulic retention time(HRT) was decreased from 2 days to i day at 600 mg/l of the phenol and catechol concentration. Stable treatment of the phenol wastewater could be achieved with the AFBR at 18 days but the catechol wastewater couldn't be. At HRT 2 days, the phenol wastewater showed the COD reduction efficiency of 93% and the gas production of 2.7 l/day and the catechol wastewater was obtained the COD reduction efficiency of 82% and the gas production of 0.72 l/day. Also at HRT 1 day the phenol and catechol wastewater showed the COD reduction efficiency of 95% and 73% and the gas production of 4.0 l/day and 1.25 l/day, respectively.

  • PDF

A Study of Echo Reduction of Underwater Acoustic Material Considering Ocean Condition (수중환경을 고려한 수중 음향재료의 반향음 감소성능 연구)

  • Seo, Young Soo;Ham, Il Bae;Jung, Woo Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.377-384
    • /
    • 2014
  • The requirement of acoustic material which is used in underwater environment more increases. The material is used to reduce acoustic signature and radiate noise for underwater vehicle. Underwater acoustic material was made by viscoelastic material such as a rubber and a polyurethane etc. The mechanical and acoustic characteristics of these material change with hydrostatic pressure. In order to increase an acoustic performance according to hydrostatic pressure, several kinds of scatterers were added to viscoelastic material. In this paper, acoustic modelling and analysis techniques of underwater acoustic material with hydrostatic pressure were introduced and proposed. The specimens for pulse tube test were made and echo reductions were calculated and measured with hydrostatic pressure. Also the characteristics of echo reduction of the specimens with hydrostatic pressure were obtained and discussed.

  • PDF

Characteristics of Sound Reduction Index through Small Sized Lightweight Panel (소형 경량판넬을 이용한 차음성능 영향요인별 음향감쇠계수 분석)

  • Yang, Hong-Seok;Kim, Myung-Jun;Jeong, Gab-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.138-147
    • /
    • 2007
  • Recently, framed structure is increasingly being used as apartment structure due to the advantages during remodeling. Therefore, the use of lightweight panel as separating wall is increasing. To construct lightweight panel structures with sound insulation performance appropriate to the conditions of each field, measurement of sound reduction index(SRI) through panel structures should be performed. In this study, measurement of SRI through 46 kinds of panel structures was performed in the condition of various factors such as surface density, air space and absorber. The result showed that SRI of panel structures was generally higher by increasing of surface density. In the case of double panel with no absorber, SRI at below critical frequency was gradually increased according to rise of air space. Double panel with absorber make remarkable improvement in SRI at low frequency, but there is a little difference compared with SRI of double panel with no absorber over critical frequency.

  • PDF

Direct Torque Control of Switched Reluctance Motor for Torque Ripple Reduction (토크 리플 저감을 위한 스위치드 릴럭턴스 모터의 직접 토크 제어)

  • Kim, Youn-Hyun;Kim, Tae-Heoung;Lee, Ju
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.283-294
    • /
    • 2004
  • This paper introduces the new Direct Torque Control(DTC) method based on the estimated torque in Switched Reluctance Motor(SRM) and applies the proposed DTC to SRM for the instantaneous torque ripple reduction. The nonlinear characteristics of SRM is considered in the calculation of the estimated torque and the theory is described in this paper. Current control is one of the kernel elements of torque controller and the performance of the current control should be high for this work. But the conventional PI current control has a weak point in SRM application because of motional EMF. Consequently, this paper makes up for the weakness of PI controller through present of new current controller, that is termed the non-interference current control. The ability of proposed torque and current controller is verified through simulation and experiment.