• Title/Summary/Keyword: performance of the test.

Search Result 21,599, Processing Time 0.048 seconds

Performance Evaluation Procedure for Advanced Emergency Braking System (자동비상제동 시스템의 안전성능평가)

  • Kim, Taewoo;Yi, Kyongsu;Choi, In Seong;Min, Kyong Chan
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.2
    • /
    • pp.25-31
    • /
    • 2015
  • This paper presents a performance evaluation procedure for advanced emergency braking (AEB) system. To guarantee the performance of AEB system, AEB test scenario should contains various driving conditions which can be occurred in real driving condition. Also, performances of each elements of AEB system, such as sensor, decision, human machine interface (HMI) and control, should be evaluated in various situations. For this, driving conditions, road types, environment, and elements of AEB system were introduced. Test scenario has been designed to represent the real driving condition and to evaluate the safety performance of AEB system in various situations. To confirm that the proposed AEB test scenario is realistic and physically meaningful, vehicle test have been conducted in two cases of proposed AEB test scenario: subject vehicle cut-out scenario and narrow street turn left scenario.

Ride Performance Evaluation of a Heavy Truck Semi-active Cabin Air Suspension System (대형 트럭 반능동형 캐빈 공기 현가시스템의 승차감 성능 평가 연구)

  • Lee, Ji-Sun;Choi, Gyoo-Jae;Lee, Kwang-Heon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.77-83
    • /
    • 2008
  • Semi-active cabin air suspension system improves driver's comfort by controlling the damping characteristics in accordance with driving situation. For the driver's comfort evaluation, test procedure has the two methodologies which are filed test and lab test. A field test method has a drawback. It requires a lot of time and money on repetitive test, due to the sensitivity of field test. On the other hand, the test with six axes simulation table at laboratory can obtain the repeatability of test, better than the field test method. In this paper, the procedures of ride performance test and control logic tuning with the table are presented. Drive files of the table can be represented with the almost same input condition as field test data. According to the result from the comparative test using six axes simulation table between passive and semi-active system by making ECU logic tuning, the RMS acceleration of semi-active cabin air suspension system was reduced by 29.6% compared with passive system.

Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT) (대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전)

  • Ahn, Jong-Woo;Kim, Gun-Do;Kim, Ki-Sup;Park, Young-Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.6
    • /
    • pp.428-434
    • /
    • 2015
  • The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.

The study of correlations between clinical balance scales and balance performance monitor parameters in patients with adolescent idiopathic scoliosis (청소년기 특발성 척추측만증 환자의 임상적 균형 평가지수와 균형 수행 모니터 측정값의 상관성 연구)

  • Shin, Seung-Sub
    • PNF and Movement
    • /
    • v.8 no.3
    • /
    • pp.39-47
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the correlations between clinical balance scales and Balance Performance Monitor parameters in patient with adolescent idiopathic scoliosis (AIS). Methods : Twenty AIS subjects (age, $14.26{\pm}1.93yrs$; height, $160.56{\pm}7.98cm$; weight, $47.54{\pm}6.94kg$)were participated in this study. Postural sway(mean balance, sway angle, sway area, sway path, maximal sway velocity) were were evaluated by balance performance monitor. Measurements for clinical balance scales were Functional reach test (both side), the Lateral reach test (both side) and One leg standing test (both legs). Results : The results were as follows. There were positive strong correlation between major curve direction and left-right sway angle, sway path, maximal sway velocity. There were negative strong correlation between the functional reach and left-right sway angle, sway area, sway path, maximal sway velocity. And the lateral reach were also showed negative strong correlation parameters of balance performance monitor. One leg standing were negatively correlated with left-right sway angle, sway path, maximal sway velocity. Conclusion : The clinical balance scales will be useful tools for balance measurements, and basic tools for clinical setting for patient with AIS.

  • PDF

A Characteristic Analysis of High Pressure and High Temperature 3-way Ball Valve (고온.고압용 3-way 볼밸브의 특성해석)

  • Lee, Joon-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.180-184
    • /
    • 2012
  • 3-way ball valves have been mostly used for high temperature/high pressure valves using in petrochemical carriers and oil tankers, which requires high quality products with confidentiality and durability. As a larger disaster may be generated by leakage of oil or gas from valves, thus the present research applied a numerical analysis method with thermal-structural coupled field analysis and the performance test. The Max stress by parts was confirmed through thermal-structural coupled field analysis and develop the 3-way ball valve design, which is safe on operating condition. And its performance was verified by carrying out pressure test, leakage test and durability test for the manufactured 3-way ball valves with satisfying it's regulations.

Consideration of Geosynthetics Chemical Resistance Test for Long-Term Performance Evaluation (장기성능 평가를 위한 토목섬유 화학저항성 시험 고찰)

  • Jeon, Han-Yong;Jang, Yeon-Soo;Gong, Hak-Bong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.222-232
    • /
    • 2009
  • In this study, the real site test conditions were considered and applied to suggest the improved test method for geosynthetics chemical resistance. For this, index and performance tests were done to specify and regulate the more approached test method. Accelerated model by Arrhenius equation was applied to interpretate the experimental data. Through analysis and comparison the overall experimental results, we could suggest the possibility and setup the advanced chemical resistance test method for geosynthetics.

  • PDF

An Experimental Study on the Ventilation performance in a Test Chamber and Office Room (모형실과 실공간에서의 환기성능에 관한 실험적 연구)

  • Yoon, Suk-Goo;Ku, Jae-Hyun;Yun, Ok-Chun;Han, Jung-Gun;Lee, Jae-Keum;Cho, Min-Chul;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.520-525
    • /
    • 2000
  • This research is to analyze the ventilation performance of mechanical ventilation systems for indoor air quality control and management. A ventilation performance with supply sites is evaluated in a test model chamber and office room. A $CO_2$ gas as a tracer gas is used to measure the ventilation performance. The ventilation performance is found to increase with increased the ventilation rate. The ventilation performance is analysed with 55% at the supply air of 570 lpm and with 20% at the supply air of 100 lpm in a test chamber. The ventilation performance is better than 15% comparing with natural decay at the supply of 570 lpm in office room.

  • PDF

Performance Test of Combustor for Aeropropulsion Gasturbine Engine (항공추진용 가스터빈엔진 연소기 성능시험)

  • Park, Poo-Min;Kim, Hyung-Mo;Choi, Young-Ho;Jeon, Byoung-Ho;Yang, Su-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.405-406
    • /
    • 2008
  • Combustor is one of the major component of gas turbine engine and its development is done mostly by performance test. Combustors for aviation gasturbine engines has been successfully tested at the test facility in KARI as well as for stationary gasturbine engines. Full scale combustor test requires large amount of high temperature and pressure air, so the test facility is equipped with big air compressor and heater.

  • PDF

Performance Assessment of Sputter-Coating-Colored BIPV Modules Through Field Test (현장 실험을 통한 Sputter Coating 컬러 BIPV 모듈의 발전성능 평가)

  • Lee, Hyo-Mun;Yoon, Jong-Ho;Kim, Hyun-Il;Lee, Gun-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.5
    • /
    • pp.1-12
    • /
    • 2020
  • To assess the performance and characteristics of colored building-integrated photovoltaic (BIPV) modules, a comparative assessment of empirical performance was conducted on colored BIPV modules (gray, blue, and orange) and general BIPV module. These modules were installed on the south-facing slope (30°) for comparative assessment through a field test. Monitoring data were collected every 10 min from December 20, 2019 to January 21, 2020 and used to performance and characteristics analysis. Performance ratio and module efficiency were utilized during performance indexing for comparative assessment. For general BIPV modules, the operational efficiency was analyzed at 16.63%, whereas for colored BIPV modules, 13.70% (gray), 15.12 % (blue), and 14.49% (orange) were analyzed. It was discovered that the efficiency reduction caused by transmission losses owing to the application of colored cover glasses were 17.74% (gray), 9.05% (blue), and 9.86 % (orange), under field testing conditions. These values turned on an additional 7% reduction in efficiency for gray BIPV modules, compared to the degradation resulting from transmission drop (gray: 10.87%, blue: 8.99%, and orange: 9.02%) calculated using the efficiency of each module in standard test conditions (STC). Performance ratio analysis resulted in the following values: 0.92 for general BIPV modules, and 0.85 (gray), 0.91 (blue), and 0.91 (orange) for colored BIPV modules. As demonstrated by the above results, modules with a colored cover glass may differ in their operational performance depending on their color, unlike general modules. Therefore, in addition to the performance evaluation under STC, additional factors of degradation require consideration through field test.