• 제목/요약/키워드: performance of experiment

검색결과 9,025건 처리시간 0.035초

합판 종류에 따른 기능성 오일스테인의 성능 평가 (Performance Evaluation of Functional Oil Stain by Plywood Type)

  • 이주원;이창우;황우준;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.35-36
    • /
    • 2022
  • In order to supplement the flame-retardant performance of oil stain, which can prevent wooden buildings from contamination, (NH4)2HPO4, a phosphorus flame-retardant, was added to oil stain and applied for each type of plywood, and an experiment was conducted. The addition rate was set to 0-60%, but white powder appeared on the surface of plywood from 40% and thus it was impossible to experiment, so the maximum addition rate was selected as 30%. As a result of the experiment, acacia plywood had the best performance. As the rate of addition of the flame retardant increased, the remaining time and carbonization length of all plywood decreased, but the carbonization length of the MDF plywood was not met with the standards.

  • PDF

시판 발열의복의 발열성능 평가 (Evaluation for the Heating Performance of the Heated Clothing on Market)

  • 이현영;정연희
    • 한국의류산업학회지
    • /
    • 제12권6호
    • /
    • pp.843-850
    • /
    • 2010
  • To evaluate the heating performance of commercial heated vests, we investigated the thermal images and the temperature between body and vest for three heated vests. We captured infrared thermography by FT-IR Spectrometer to analyzed the heating temperature of the heating elements taken from the vests, and the maximum heating temperature of the vests was compared with thermal image in the room temperature($18^{\circ}C$). In outdoor experiment($-4.7^{\circ}C$), we measured the inner temperature as well as the thermal image of heated vests. Four healthy men participated in this experiment, and the ANOVA and Duncan test was performed for statistical analysis. As the results, the heating temperature range of the heated vests used in this experiment was $32{\sim}42^{\circ}C$, much lower than the displayed temperature range in their specifications, so the exact specification for heating performance of heated clothing was required. In comparisons of the heating performance among the heated vests, we found out that the insulation of clothing is very important to design the heated clothing, because the inner temperature of the vest had good insulation by itself was higher than that of the vest shown higher temperature over $7^{\circ}$ than another vests at the heating temperature.

캔드타입 전동워터펌프용 수중베어링의 특성분석 (Characteristic Analysis of Underwater Bearing for Canned-Type Electric Water Pump)

  • 박인겸;김형진;홍남표;서영호;김병희
    • 한국생산제조학회지
    • /
    • 제23권2호
    • /
    • pp.186-193
    • /
    • 2014
  • This paper presents characteristic analysis of underwater bearing for canned type electric water pump. Characteristic analysis of underwater bearing was performed using self-developed performance tester, which capable of torque change, noise change, motor speed change and abrasion loss test with respect to temperature change of underwater bearing. The performance tester can be monitored in real time by designing the control unit using the Labview program. The performance experiment was performed through comparison of the silicon carbide (SIC) and the carbon bearing. From the experiment results, performance of SIC bearing was better than carbon bearing at the abrasion and temperature experiment.

FRP-콘크리트 합성 바닥판의 윤하중 피로 성능 평가 (Evaluation of Wheel Load Fatigue Performance of FRP-Concrete Composite Deck)

  • 조근희;박성용;조정래;김성태;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.38-41
    • /
    • 2006
  • Wheel load fatigue experiment is carried out on a FRP-concrete composite deck. In FRP-concrete composite deck, FRP plays a role of a main tensile member as well as a permanent formwork and concrete plays a role of a main compressive member. Wheel load fatigue experiment, which shows more realistic behavior than pulsating fatigue experiment, is selected as a fatigue performance evaluation method. Until 1,000,000 cycles of loadings, load resistant performance is maintained without any loss, while residual deflection is increased.

  • PDF

PCA기반의 얼굴인식 알고리즘들에 대한 연산방법 분석 (Computational Analysis of PCA-based Face Recognition Algorithms)

  • Hyeon Joon Moon;Sang Hoon Kim
    • 한국멀티미디어학회논문지
    • /
    • 제6권2호
    • /
    • pp.247-258
    • /
    • 2003
  • 얼굴인식 기술 분야에 있어서 Principal component analysis (PCA)기반 알고리즘은 많은 관련 알고리즘의 기초가 되고 있다. PCA는 매우 통계적인 접근이며 얼굴인식 분야에 응용하기 위해서는 많은 설계 결정요인 (design derision)을 필요로 한다. 본 논문에서는 일반적인 modular PCA알고리즘을 소개하면서 design decision을 얻는다. 얼굴인식 알고리즘 평가에 대한 표준 접근 방법인 September 1996 FERET evaluation protocol을 활용하여 각 모듈에 대한 서로 다른 구현방법을 실험하고 평가한다. 실험조건으로는 (1) 조도의 정규화 과정 을 변화 (2) JPEG과 wavelet compression 알고리즘 사용에 대한 성능효과를 분석 (3) 표현방법에서 eigenvectors의 수를 조절 (4) 분류과정에서 유사도 측정방법을 변경하는 등이다. 본 논문에서는 standard September 1996 FERET의 대용량 gallery image set에 대해 적용해 본 결과에 대해 정리하며, 100개의 무작위로 발생된 image set에 대해서도 알고리즘의 성능 변화를 평가한다.

  • PDF

열전소자를 이용한 액체 냉각기의 냉각열전달 특성 (Cooling characteristics of a Liquid cooler Using Thermoeletric Module)

  • 박민영;이근식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.197-202
    • /
    • 2007
  • In this study, the cooling characteristics of a liquid cooler using thermoelectric module was experimentally investigated. The experiment was conducted for various inner structures of liquid cooler (4 cases), hot fluid flow rates (0.15-0.25 L/min), number of T.E module (2, 4, 6 set), and the cooling water flow rates (200-600 cc/min) for both parallel and counter flow types. Among the results, better cooling performance geometry was selected. And experiment was also carried out to examine further enhancement of cooling performance by inserting coils (pitches: 0.2, 3, 6 mm) into the hot-fluid channel. Present results showed that the short serpentine type(case2) indicated the best cooling performance. In the case of coil pitch of 3 mm, the best cooling performance was shown, more than 10% increase of the inlet and outlet temperature difference, compared with the case of the cooler without coil. Consequently, the inserted coil pitch should be properly selected to improve cooling performance.

  • PDF

가상현실 표시장치에서의 시간적, 공간적, 회화적 해상도에 따른 가상물체 이동작업의 인간성능 평가 (Human Performance Evaluation of Virtual Object Moving Task in the Different Temporal, Spatial and Pictorial Resolution of a Stereoscopic Display)

  • 박재희
    • 산업공학
    • /
    • 제18권1호
    • /
    • pp.82-87
    • /
    • 2005
  • Most of virtual reality systems ask users to control 3D objects or to navigate 3D world using 3D controllers. To maximize the human performance in the control, the design of virtual reality system and its input and output devices should be optimized. In this study, an experiment was designed to investigate the effects of three resolution factors of a virtual reality system on the human performance. Six subjects conducted the experiment for the factors; two frame rates, three spatial resolutions, and three pictorial contents. The result showed that the greater the spatial resolution was, the higher the human performance was. For the temporal resolution, fixed frame rate at 18 Hz was better than the varied maximized frame rate. For the pictorial contents, the virtual space with orientation cues marked the greatest performance than the other two conditions; the virtual space without any orientation cue and the virtual space like real world. These results could be applied for the design of virtual reality systems.

재열기를 사용한 고성능 VI 사이클 열펌프의 난방 성능 특성에 관한 연구 (A Study on the Characteristics of Heating Performance of High-Performance Heat Pump with VI cycle using Re-Heater)

  • 이진국;최광환
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.69-75
    • /
    • 2015
  • In this study, the characteristics of heating performance of a high-performance air-cooled heat pump with vapor-injection(VI) cycle using re-heater was investigated experimentally. Devices used in the experiment is consist of a VI compressor, condenser, oil separator, refrigerant (economizer outlet refrigerant) re-heater, economizer, evaporator. And R410A was used as a working fluid. The experiment was conducted with two cycles(cycles A and B) for investigating heating performance. In case of cycle B, heat exchange was conducted by re-heater between outlet refrigerant of compressor and suction refrigerant of the VI system(Fig.1, re-heater). But the re-heater was not used in case of cycle A. As a result of this experiment, discharge temperature of refrigerator in compressor was shown higher value, when the cycle B was conducted, because of the heat exchange between suction refrigerant of VI cycle and outlet refrigerant of compressor in the re-heater than cycle A that was not use re-heater. it means that liquid hammer and the decrement of heating performance can be decreased by using re-heater. Also, Heating coefficient of performance(COPh) was shown about 2.98 in Cycle B which was 4% higher than Cycle A and from these results, It was confirmed that the improvement of the heating performance of heat pump with VI cycle can be achieved by applying re-heater.

MEASUREMENT OF SYNTHESIS RATE OF LONG-CHAIN ACYL-COENZYME A ESTER IN BOVINE LIVER BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

  • Mitsuhashi, T.;Mitsumoto, M.;Yamashita, Y.;Ozawa, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제1권2호
    • /
    • pp.99-106
    • /
    • 1988
  • A high performance liquid chromatographic procedure is described for the direct determination of the picomole amount of palmitoyl-Coenzyme A and stearoyl-Coenzyme A, using a stainless steel column packed with C-18 derivatized porous silica ($5{\mu}m$), an isocratic elution with a mixture of 33 mM $KH_2PO_4$/acetonitrile as a mobile phase and a UV detector. The long-chain acyl-Coenzyme A esters were determined in incubated microsomal fractions of a bovine liver to demonstrate the utility of this method for monitoring acyl-CoA synthesis in biological samples. The reaction rate of palmitate was higher than that of stearate. After a 60 minute incubation period, the generated amount of palmitoyl-Coenzyme A and stearoyl-Coenzyme A were approximately 70 and 20 n mol/mg micresomal protein, respectively. The advantage of this method are in that no decomposition of the CoA esters is involved, while the constituent molecular species is detected.

Studies on the Development of a Tea Harvesting Machine

  • Okada, Yoshiichi;Gejima, Yshiinori
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.478-487
    • /
    • 1996
  • A " plucking rolls device" was developed in this study to improve the quality of harvested tea leaves. In this report, the outline of the system and the results of performance experiments in our laboratory are discussed. Tow kinds of performance experiments were carried out. The first experiment checked harvesting accuracy by using a plucking unit that was developed for harvesting machine installation. The second experiment was a harvesting experiment which utilized a fron bar in order to prevent cutting of the tea buds which had been a problem in precious experiments . As a results of the first experiments , it was confirmed that selective harvesting obtained high quality tea leaves. but a cutting problem that, when the harvesting seed was faster than the working speed, which was non-selective harvesting , was also seen. In the second experiment, the cutting rate decreased to a maximum of 50% level, when tea buds most bent ahead by the front bar. The effect was seen that cutt ng problem was alleviated from this.

  • PDF