• Title/Summary/Keyword: performance improvement

Search Result 12,253, Processing Time 0.052 seconds

Efficiency Test for Surface Protecting Agents for the Chemical Resistance of Concrete Structures Using Sulfur Polymers (Sulfur Polymer를 사용한 콘크리트 구조물용 내화학성 표면보호재의 성능 평가)

  • Lee, Byung-Jae;Lee, Eue-Sung;Chung, Woo-Jung;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2014
  • Structures requiring chemical resistance are usually coated with surface protecting agents, but the cost for maintenance and re-construction is incurred due to the low durability. Therefore, in this study, sulfur was polymerized and the performance was examined so that it could be used as the concrete surface protecting agents for structures requiring chemical resistance. The evaluation results indicated that for the spray of the sulfur polymer surface coating agents, the application of the gravity type was appropriate; and for the number of coating times, about 3 cycle spray gave the best results. For the surface condition of the concrete to be coated with the surface protecting agents, outstanding quality was obtained above room temperature ($20{\sim}30^{\circ}C$), and the bond strength increased as the temperature increased. The evaluation results of the strength characteristics depending on the filler content of the surface protecting agents indicated that about 20~40% filler mixing contributed to the strength improvement as it reduced the shrinkage of the sulfur polymer. Also, the mixing of silica showed larger increase in the bond strength than the mixing of fly ash, and the most outstanding bond strength characteristics could be obtained by the mixing of both silica and fly ash. In the case of the chemical resistance, the strength reduction was minimized and outstanding chemical resistance was obtained when the fly ash and silica were substituted by 20%, respectively. The performance evaluation of the chloride ion penetration indicated that for the specimens coated with the sulfur polymer surface protecting agents, the chloride ion penetration resistance increased by 29~48% compared to the specimen without the coating of the surface protecting agent. The examination of the coating condition of the surface protecting agents, compressive strength, bond strength, chemical resistance, and salt damage resistance indicated that in the range of this study, the optimal level was when the silica and fly ash were substituted by 20%, respectively, as the filler for the sulfur polymer.

A Study on the Water Quality Improvement in Semi-closed Sea Area Using Solar Powered Circulators (태양광 물 순환장치 가동에 의한 반폐쇄성 수역의 수질 변화)

  • Kim, Deok-Gil;Lee, Eun-Kyeong;Kim, Mu-Chan;Song, Sung-Kyu;Cho, Kwang-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.3
    • /
    • pp.257-262
    • /
    • 2012
  • This study was conducted to verify the performance of the solar water circulation apparatus that was installed in a semi-closed sea area of Tongyeong to improve the water quality through removing thermocline and oxygen depleted water mass, and to prevent the occurrence of red tides caused by eutrophication. From 8 weeks of experiments, we found that the thermocline in the semi-closed sea area has been removed gradually after installation of the apparatus. The initial temperature of surface and bottom was $27.9^{\circ}C$ and $23.8^{\circ}C$, respectively and it was changed to $22.1^{\circ}C$ in both depth. In case of DO concentration, there was a big gap between surface (5.49 mg/L) and bottom (2.61 mg/L) and was an oxygen depleted water mass in the bottom area at initial. However DO concentration in bottom layer has increased gradually after operation (6.19 mg/L) and the oxygen depleted water mass has removed. Due to the effects of seasonal variation and the operation of the solar water circulation apparatus for 8 weeks, COD concentration decreased from 5.61 mg/L to 2.36 mg/L in surface area, and from 6.08 mg/L to 1.73 mg/L in bottom area. Dissolved inorganic nitrogen concentration also decreased from 0.135 mg/L to 0.050 mg/L in surface area, and from 0.076 mg/L to 0.051 mg/L in bottom area. This research was conducted from July to September, and it might be possible that the variation of water quality was affected by both seasonal variation and the operation of the water circulation apparatus. Hence a further research is required to verify the performance of the water circulation apparatus itself and to monitor dissolved inorganic nitrogen and phosphorous concentrations as well as Chl-a.

Effect of the Preparation Method on the Activity of CeO2-promoted Co3O4 Catalysts for N2O Decomposition (촉매 제조방법에 따른 Co-CeO2 촉매의 N2O 분해 특성 연구)

  • Kim, Hye Jeong;Kim, Min-Jae;Lee, Seung-Jae;Ryu, In-Soo;Yi, Kwang Bok;Jeon, Sang Goo
    • Clean Technology
    • /
    • v.24 no.3
    • /
    • pp.198-205
    • /
    • 2018
  • This study investigated the influence of catalyst preparation on the activity of $Co-CeO_2$ catalyst for $N_2O$ decomposition. $Co-CeO_2$ catalysts were synthesized by co-precipitation and incipient wetness impregnation. In order to estimate the performance of the as prepared catalysts, direct catalytic $N_2O$ decomposition test was carried out under $250{\sim}375^{\circ}C$. As a result, the catalyst prepared by co-precipitation (CoCe-CP) showed an enhanced performance on $N_2O$ decomposition reaction even in the presence of $O_2$ and/or $H_2O$, whereas the impregnation catalyst (CoCe-IM) did not. In order to investigate the difference in catalytic activity, characterization such as XRD, BET, TEM, $H_2-TPR$, $O_2-TPD$, and XPS was conducted. It is confirmed that the particle size and specific surface area were changed depending on the catalyst preparation method and the synthesis process influenced the physical properties of the catalysts. In addition, the improvement in the activity of the catalyst prepared by co-precipitation is due to the enhanced reduction from $Co^{3+}$ to $Co^{2+}$ and the improved oxygen desorption rate. However, it has been confirmed that the surface electron state and binding energy, which are related to $N_2O$ decomposition, do not change depending on the preparation method.

A Study for Design and Performance Improvement of the High-Sensitivity Receiver Architecture based on Global Navigation Satellite System (GNSS 기반의 고감도 수신기 아키텍처 설계 및 성능 향상에 관한 연구)

  • Park, Chi-Ho;Oh, Young-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.4
    • /
    • pp.9-21
    • /
    • 2008
  • In this paper, we propose a GNSS-based RF receiver, A high precision localization architecture, and a high sensitivity localization architecture in order to solve the satellite navigation system's problem mentioned above. The GNSS-based RF receiver model should have the structure to simultaneously receive both the conventional GPS and navigation information data of future-usable Galileo. As a result, it is constructed as the multi-band which can receive at the same time Ll band (1575.42MHz) of GPS and El band (1575.42MHz), E5A band (1207.1MHz), and E4B band (1176.45MHz) of Galileo This high precision localization architecture proposes a delay lock loop with the structure of Early_early code, Early_late code, Prompt code, Late_early code, and Late_late code other than Early code, Prompt code, and Late code which a previous delay lock loop structure has. As we suggest the delay lock loop structure of 1/4chips spacing, we successfully deal with the synchronization problem with the C/A code derived from inaccuracy of the signal received from the satellite navigation system. The synchronization problem with the C/A code causes an acquisition delay time problem of the vehicle navigation system and leads to performance reduction of the receiver. In addition, as this high sensitivity localization architecture is designed as an asymmetry structure using 20 correlators, maximizes reception amplification factor, and minimizes noise, it improves a reception rate. Satellite navigation system repeatedly transmits the same C/A code 20 times. Consequently, we propose a structure which can use all of the same C/A code. Since this has an adaptive structure and can limit(offer) the number of the correlator according to the nearby environment, it can reduce unnecessary delay time of the system. With the use of this structure, we can lower the acquisition delay time and guarantee the continuity of tracking.

A Study on Forecasting Accuracy Improvement of Case Based Reasoning Approach Using Fuzzy Relation (퍼지 관계를 활용한 사례기반추론 예측 정확성 향상에 관한 연구)

  • Lee, In-Ho;Shin, Kyung-Shik
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.4
    • /
    • pp.67-84
    • /
    • 2010
  • In terms of business, forecasting is a work of what is expected to happen in the future to make managerial decisions and plans. Therefore, the accurate forecasting is very important for major managerial decision making and is the basis for making various strategies of business. But it is very difficult to make an unbiased and consistent estimate because of uncertainty and complexity in the future business environment. That is why we should use scientific forecasting model to support business decision making, and make an effort to minimize the model's forecasting error which is difference between observation and estimator. Nevertheless, minimizing the error is not an easy task. Case-based reasoning is a problem solving method that utilizes the past similar case to solve the current problem. To build the successful case-based reasoning models, retrieving the case not only the most similar case but also the most relevant case is very important. To retrieve the similar and relevant case from past cases, the measurement of similarities between cases is an important key factor. Especially, if the cases contain symbolic data, it is more difficult to measure the distances. The purpose of this study is to improve the forecasting accuracy of case-based reasoning approach using fuzzy relation and composition. Especially, two methods are adopted to measure the similarity between cases containing symbolic data. One is to deduct the similarity matrix following binary logic(the judgment of sameness between two symbolic data), the other is to deduct the similarity matrix following fuzzy relation and composition. This study is conducted in the following order; data gathering and preprocessing, model building and analysis, validation analysis, conclusion. First, in the progress of data gathering and preprocessing we collect data set including categorical dependent variables. Also, the data set gathered is cross-section data and independent variables of the data set include several qualitative variables expressed symbolic data. The research data consists of many financial ratios and the corresponding bond ratings of Korean companies. The ratings we employ in this study cover all bonds rated by one of the bond rating agencies in Korea. Our total sample includes 1,816 companies whose commercial papers have been rated in the period 1997~2000. Credit grades are defined as outputs and classified into 5 rating categories(A1, A2, A3, B, C) according to credit levels. Second, in the progress of model building and analysis we deduct the similarity matrix following binary logic and fuzzy composition to measure the similarity between cases containing symbolic data. In this process, the used types of fuzzy composition are max-min, max-product, max-average. And then, the analysis is carried out by case-based reasoning approach with the deducted similarity matrix. Third, in the progress of validation analysis we verify the validation of model through McNemar test based on hit ratio. Finally, we draw a conclusion from the study. As a result, the similarity measuring method using fuzzy relation and composition shows good forecasting performance compared to the similarity measuring method using binary logic for similarity measurement between two symbolic data. But the results of the analysis are not statistically significant in forecasting performance among the types of fuzzy composition. The contributions of this study are as follows. We propose another methodology that fuzzy relation and fuzzy composition could be applied for the similarity measurement between two symbolic data. That is the most important factor to build case-based reasoning model.

Factors Influencing the Therapeutic Compliance of Patients with Lung Cancer (폐암환자의 치료순응도에 영향을 미치는 요인)

  • Chae, Sang-Chul;Park, Jae-Yong;Kim, Jeong-Suk;Bae, Moon-Seob;Shin, Moo-Chul;Kim, Keon-Yeob;Kim, Chang-Ho;Shon, Sang-Kyun;Kam, Sin;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.953-961
    • /
    • 1998
  • Background : In recent years, lung cancer has been one of most common cause of death in Korea. Despite many physician's high degree of pessimism about the gains made in treatment, progressive improvement in the survival of lung cancer by treatment has occurred, particulary in the early stages of the disease. However, a lot of patients refuse treatment or give up in the fight against the disease. This study was done to evaluate factors influencing the compliance to therapy and to lead in the establishment of special programs to enhance compliance in patients with lung cancer. Methods: The medical records of 903 patients, whose ECOG(Eastern Cooperative Oncology Group) performance status was 3 or less and whose medical record was relatively satisfactory, among 1141 patients diagnosed with lung cancer between January 1989 and December 1996 were reviewed retrospectively. Compliance was classified into three groups based on the degree of compliance with physicians practice guideline: (a) compliants; (b) patients who initially complied but gave up of themselves midway during the course of treatment; (c) noncompliants who refused the treatment. Results: The overall compliance rate was 63.9%, which was progressively increased from 57.3-61.3% in 1989 and 1990 to 64.2-67.5% in 1995 and 1996. Age, education level and occupation of patients bore statistically significant relationship with the compliance but sex, marital status and smoking history did not. The compliance was significantly higher in patients without symptoms than with, and was also significantly higher in patients with good performance status. The compliance was significantly high in patients with NSCLC(non-small cell lung cancer) compared to SCLC(small cell lung cancer), but after exclusion of stage I and II, among NSCLC, which had higher compliance to surgery there was no significant difference of compliance by histology. The compliance was significantly lower in advanced stage. Conclusion: To enhance the compliance, special care including education programs about therapy including complication and prognosis are necessary, especially for educationally and economically disadvantaged patients.

  • PDF

A Study on the Development of a Competency-Based Intervention Course Curriculum of the Korean Academy of Sensory Integration (대한감각통합치료학회 역량기반 중재과정 교육커리큘럼 개발연구)

  • Namkung, Young;Kim, Kyeong-Mi;Kim, Misun;Lee, Jiyoung
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.17 no.3
    • /
    • pp.26-45
    • /
    • 2019
  • Objective : The purpose of this study is to develop educational goals, training content, and training methods for the intervention course of the Korean Academy of Sensory Integration (KASI) and to conduct competency-based intervention courses based on the competency model for sensory integration intervention. Methods : This study was conducted on work therapists who participated in the 2019 intervention course of KASI. In the first phase, educational needs were analyzed to set goals for the interventional course. In the second phase, a meeting of researchers drafted the intervention course education program and the methods of education, and the intervention course was conducted. In the third phase, the changes in educational satisfaction and performance level pre- and post-intervention course for each competency index were investigated. Results : The educational goals of "learning and applying the clinical reasoning process of sensory integration intervention" and "intervention by applying the principle of sensory integration intervention" were set after reflecting on the results of the analysis of the educational requirements. The length of the competency-based intervention course was 42 hours. The average education satisfaction level of participants in the arbitration process was 4.48±0.73, and the average education satisfaction level of the supervisor was 3.92±0.71. In both groups, the most satisfying curriculums were the data-driven decision-making process and the intervention goal-setting lecture. But the satisfaction level of was the lowest. Before and after the intervention course, there were significant changes in the performance of the two behavioral indicators of the analytic skills in the expertise competency cluster of the competency model. Conclusion : This study is meaningful in that it conducted a survey of educational needs, the development and implementation of an educational curriculum, and an education satisfaction survey through systematic courses necessary for education development.

Results of Arthroscopic Debridement of the Elbow Osteoarthritis (주관절 골관절염에서 관절경적 변연절제술 후 결과)

  • Chun, Churl-Hong;Kim, Jung-Woo;Lim, Jae-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Purpose: Primary osteoarthritis on the elbow is the result of the growth of osteophytes and contracture of the capsule. It often causes disability on joint motion and pain while exercising. As arthroscopy has developed, the arthroscopic diagnosis and treatment of the elbow have recently become more generalized as well. Therefore, we like to report on arthroscopy for treating elbow arthritis and its results. Materials and Methods: This study includes 23 cases of elbow arthritis that were seen between 2005 June to 2007 June and these patients didn't response to conservative treatment. From this we excluded 18 cases that underwent arthroscopic surgery and among these 18 cases, 6 cases underwent ulnar nerve transfer. The average observation time was 21.3 months and the average age was 48.4 years (range: 22-66 years). The pre and post operative pain was evaluated with using the Visual Analogue Scale (VAS) and functional evaluation was done with using the Mayo elbow Performance Score (MEPS) with the range of joint motion. Results: The VAS score at the last follow up was significantly decreased from 3.4 to 1.9 compare to the preoperative score. The range of joint motion was improved by 25 (0-40) to 8.5 (0-20) in extension and 101.7 (80-140) to 125.2 (85-140) in flexion (p<0.05). The MEPS always showed significant improvement by showing an increase from 65.4 (40-85) to 87.9 (55-100). However, 3 cases showed a decreased range of motion after the operation. One case showed ulnar nerve symptoms after surgery. Conclusion: An arthroscopic procedure can treat the pathologic processes associated with arthritis of the elbow and it was safe and effective in this series.

Improvement of the Elbow Function with Early Mobilization and Rigid Fixation of Coronoid Fracture by Tension Band Technique (압박 긴장대 방법을 이용한 구상 돌기 골절의 견고한 고정과 조기 운동을 통한 주관절 기능의 향상)

  • Rhyou, In-Hyeok;Suh, Bo-Gun;Kim, Hyung-Jin;Chung, Chae-Ik;Kim, Kyung-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.159-166
    • /
    • 2009
  • Purpose: We wanted to evaluate the surgical results of early mobilization after rigid fixation of small coronoid fracture using the tension band technique Materials and Methods: Eight cases of coronoid fracture were fixed with the tension band technique and using K-wire and wire through the medial approach. All the cases were Regan-Morrey type 2. According to O'Driscoll, they were classified as 5 cases of the tip type (subtype 2) and 3 cases of the anteromedial type (1 case of subtype 2, and 2 case of subtype 3). The associated collateral ligament injuries (6 cases) and radial head/neck fractures (4 cases) were managed simultaneously. After immobilization for 5~7 days, active ROM exercise with a fitted hinge brace started and continued till postoperative 6 weeks. The patients were assessed for pain, ROM and functional disability using the Mayo elbow performance score (MEPS) at an average of 11 months (range: 6~28 months). The ulnar nerve symptoms were also investigated. Results: We observed solid union in all the coronoid fractures without hardware failure. An average of 2.2 wires (range: 2~4) were used. The mean extension was $3^{\circ}$(range: $0^{\circ}\sim25^{\circ}$), the mean flexion was $137^{\circ}$(range: $130^{\circ}\sim140^{\circ}$), the mean pronation was $69^{\circ}$(range: $45^{\circ}\sim90^{\circ}$) and the mean supination was $78^{\circ}$(range: $45^{\circ}\sim90^{\circ}$). The mean MEPS was 96 (range: 65~100). Ulnar nerve symptoms occurred at postoperative one day and persisted in one patient with the terrible triad of taking radial head excision and residual medial instability. Conclusion: The tension band technique uses easily obtained, economic K-wires and the wire was strong enough to permit early elbow ROM exercise and the technique might improve the elbow function. It was especially useful for fixation of multiple small fragments.

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF