• Title/Summary/Keyword: performance evaluation and design

Search Result 3,783, Processing Time 0.049 seconds

Design of Personalization Service System in Mobile GIS (모바일 GIS에서의 개인화 서비스 시스템 설계)

  • Park, Key-Ho;Jung, Jae-Gon
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2008.10a
    • /
    • pp.106-112
    • /
    • 2008
  • Personalization is user oriented dynamic method based on user preferences for easy access to what users want to view or get. It has become more important in mobile domain with rapid growth of wireless Internet and mobile phone market after success of web based market and therefore, it can be applied to service of spatial analysis result. In this paper, spatial analysis using user profile and notification service methods are proposed as one of personalized spatial data service methods for mobile users. A service system for spatial analysis with user profile is designed to prove possibility of spatial analysis based on user preferences and notification service is also designedto show generated output can be sent to user's mobile devices efficiently to make users informed of preferred information. Prototype system is implemented and it is applied to real estate data that has many selectable conditions by users. Information service based on user preferences can be applied to spatial data by using proposed system and it is efficient when cache module is used to shorten response time. Various user models for application domains and performance evaluation methods need to be developed in the future.

  • PDF

The effects of learning method, learning schedule, and task difficulty on the learning of computer software (학습방법, 학습계획, 과제 난이도가 소프트웨어 학습에 미치는 영향)

  • Kim, Kyung-Su;Li, Hyung-Chul;Kim, Shinwoo
    • Science of Emotion and Sensibility
    • /
    • v.17 no.1
    • /
    • pp.3-12
    • /
    • 2014
  • Quick and accurate learning of diverse electronic products has become an important daily task. In particular, software occupies core status in the control and operation of the products. This research tested the effects of learning method, schedule, and task difficulty in the learning of software. Using 2 (learning method: experiential vs. verbal) ${\times}$ 2 (learning schedule: spaced vs. massed) ${\times}$ 2 (difficulty: easy vs. difficult) between-subjects design, Experiment 1 tested participants' learning of file control using Windows Movie Maker. There was no effect of learning schedule on task completion time, but participants in experiential learning were faster in the completion of evaluation task compared with those in verbal learning condition. Importantly, as task difficulty increases participants in verbal condition showed markedly lower performance than those in experiential condition, which suggests that experiential learning is more effective with more difficult learning task. That is, in case of learning simple operation of software verbal learning using linguistic manual or instruction could be sufficient; on the other hand in case of learning complex operation learning from experience or tutorial mode would be more effective. Additional studies which manipulated task difficulty (Expt. 2) and inter-trial learning interval (Expt. 3) did not produce meaningful results.

An analytical study on the thermal performance of multi-tube CO2 water heater (다중관형 CO2 급탕열교환기의 열적성능에 대한 해석연구)

  • Chang, Keun Sun;Choi, Youn Sung;Kim, Young-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.23-30
    • /
    • 2016
  • In this study, the heat transfer and pressure drop characteristics were evaluated for multi-tube $CO_2$ water heaters with lengths of 4.5 m and 7.5 m. The evaluation was done using the -NTU method, and the results were compared with experimental data. Water flows through the shell side of the water heater, while $CO_2$ flows through 8 inner tubes. The heater uses a counter-current design to maximize the heat transfer efficiency. The energy balance equation describing the flows of $CO_2$ and water for each node is set up using the section-by-section method. The calculated heat transfer rates agree well with the experimental data within ${\pm}5%$ error. The outlet water temperature decreased linearly with the increase of the water flow rate. The calculated heat transfer rates agreed well with the experimental data within ${\pm}3%$ error. The results show that the heat transfer rate increases almost linearly with the increase of water flow rate or $CO_2$ inlet temperature in both the 4.5-m and 7.5-m water heaters, whereas the water outlet temperature linearly decreases with the increase of the water flow rate. The comparison of the $CO_2$ pressure drop between the calculation and experiment results shows good agreement at the high $CO_2$ flow rate within 5 % error, but the value is about 20 % higher in the experimental pressure drop at the low $CO_2$ flow rate.

A Study on Fire Performance Evaluation of EIFS on Anti-Flaming Finish by Cone Calorimeter Test (콘칼로리미터에 의한 외단열시스템의 방염 화재성능평가를 위한 연구)

  • Min, Se-Hong;Sun, Ju-Seok;Kim, Sang-Chul;Choi, Yong-Mook;Lee, Seok-Ki
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.106-111
    • /
    • 2012
  • In this study, EIFS (Exterior insulation finish system) of exterior cladding was applied Cone calorimeter test to confirm the effect of flame retardant. As a results, the initial ignition points in accordance with the coated form and concentration of the flame retardant was delayed. But flame resistant treatment of EIFS cladding to control the fire will not affect confirmed that. In addition, EIFS that uses high-density and low-density due to difference in the density of the impact of the fire was no difference. The exterior of the ignition experiment occurred before and after 40 seconds, heat release rate to 100 seconds appears to occur about 90 % compared with the other exterior wall materials, the initial fire spread very fast was confirmed. EIFS cladding in order to prevent the spread of fire in the application of EIFS legally use is limited by the use of the building. And flame spread can be prevented, such as a vertical outer wall compartment measures are urgently needed.

Performance Evaluation of perpetual Asphalt Pavements Using an Accelerated Pavement Tester (포장가속시험기를 이용한 장수명 아스팔프포장의 공용성 평가 연구)

  • Song, Seo-Gyu;Lee, Jung-Hun;Lee, Hyun-Jong;Hwang, Eui-Yoon
    • International Journal of Highway Engineering
    • /
    • v.7 no.3 s.25
    • /
    • pp.1-10
    • /
    • 2005
  • In this study, accelerated pavement tester(APT) was performed on long-life asphalt pavements that can save maintenance and user costs by increasing the design life twice longer than conventional asphalt pavements. Basic material testings are first conducted on a high modulus base(HMB) mixture developed in this study. Four different pavement sections including thin and thick conventional and thin and thick HMB courses are constructed to compare the load-carrying capacities and to investigate the fatigue and rutting performances using an accelerated pavement tester. Tensile strain values at the bottom of base courses under the various loading levels are measured. The tensile strain values of the HMB sections are lower than those of the conventional sections. It is observed from the APT performed on the thin pavement sections that no significant cracks are developed up to the 180,000 cycles of a wheel load. In terms of rutting, only 3mm of rutting is developed in the thick HMB section while 5.3mm of rutting is developed in the thick conventional section at the 90,000 cycles of the wheel load. The HMB material developed in this study can be successfully used in the long-life asphalt pavements because of its excellent fatigue and rutting performances. It is estimated from a series of structural analysis that the use of the HMB material instead of the conventional base materials may reduce the asphalt thickness at least 5cm because of its better load-carrying capacity.

  • PDF

Design and Evaluation of a Buffering Patching Technique for VOD Systems (주문형 비디오 시스템을 위한 버퍼링 패칭 기법의 설계 및 평가)

  • 하숙정;배인한
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.10
    • /
    • pp.523-532
    • /
    • 2003
  • Video on Demand(VOD) services cause high resource consumption in a video seuer, because multimedia are characterized by continuous playback, a high bandwidth requirement, and long playback duration. Patching has been proposed to save the network I/O bandwidth of a video server. To achieve true VOD, patching uses multicasting to share video streams, thereby providing immediate VOD services to users without any service latency. A communication channel is used to either multicast the entire video as a regular channel or multicast only the leading portion of a video as a Patching channel. This paper Proposes a buffering patching technique that divides regular channels, as used in patching, into sub-regular channels and regular channels to shorten the holding time of the channels. In the proposed technique, the last portion of video data, corresponding to the size of the buffering window, is not transferred by sub-regular channels, but rather downloaded and buffered in the user buffer from the latest regular channel. When simulations were performed to compare the performance of the proposed technique with that of conventional patching, the results indicated that the proposed technique was superior in terms of the defection rate, average service latency, and fairness, although the amount of video data buffered at each user station was higher than that with patching.

Design and Evaluation of a NIC-Driven Host-Independent Network System (네트워크 인터페이스 카드에 기반한 호스트 독립적인 네트워크 시스템의 설계 및 성능평가)

  • Yim Keun Soo;Cha Hojung;Koh Kern
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.11
    • /
    • pp.626-634
    • /
    • 2004
  • In a client-server model, network server systems suffer from both heavy communication and computational loads. While communication channels become increasingly speedy, the existing protocol stack architectures still include mainly three performance bottlenecks of protocol stack processing, system call, and network interrupt overheads. To address these obstacles, in this paper we present a host-independent network system where a network interface card (NIC) is utilized in an efficient manner. First, by offloading network-related portion to the NIC, the host can fully utilize its processing power for other useful purposes. Second, it eliminates the system call overhead, such as context-switching and memory copy operations, since the host communicates with the NIC through its user-level libraries. Third, it a] so reduces the network interrupt operation count as the host handles the interrupt in a segment instead of a packet. The experimental results show that the proposed network system reduces the host CPU overhead for communication system by 68-71%. It also shows that the proposed system improves the communication speed by 11-83% under heavy computational and communication load conditions.

A Study on the Cascade Hybrid Cooling/Refrigeration Cycle Equipped With Intercooler and Air-Cooled Condenser in Series (인터쿨러와 공랭식 응축기를 동시에 사용하는 냉방-냉동 겸용 캐스케이드 사이클에 대한 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.353-362
    • /
    • 2019
  • Thermodynamic analysis of cascade refrigeration systems has attracted considerable research attention. On the other hand, a system evaluation based on thermodynamic analyses of the individual parts, including the evaporator, condenser, intercooler, expansion valve, etc., has received less attention. In this study, performance analysis was conducted on a cascade refrigeration system, which has an individual cooling and refrigeration evaporator, and equips the intercooler and air-cooled condenser in a series in a lower cycle. The thermo-fluid design was then performed on the major components of the system - upper condenser, lower condenser, cooling evaporator, refrigeration evaporator, intercooler, compressor, electronic expansion valve - of 15 kW refrigeration, and 8 kW cooling capacity using R-410A. A series of simulations were conducted on the designed system. The change in outdoor temperature from 26 C to 38 C resulted in the cooling capacity of the lower evaporator remaining approximately the same, whereas it decreased by 9% at the upper evaporator and by 63% at the intercooler. The COP decreased with increasing outdoor temperature. In addition, the COP of the cycle with the intercooler operation was higher that of the cycle without the intercooler operation. Furthermore, the increase in the upper condenser size by two fold increased the upper evaporator by 4%. On the other hand, the lower evaporator capacity remained the same. The COP of the upper cycle increased with increasing upper condenser size, whereas that of the lower cycle remained almost the same. When the size of the lower condenser was increased 2.8 fold, the intercooler capacity increased by 8%, whereas those of upper and the lower evaporator remained approximately the same. Furthermore, the COP of the lower cycle increased with an increase in the lower condenser. On the other hand, the change of the upper condenser was minimal.

Seismic Zonation on Site Responses in Daejeon by Building Geotechnical Information System Based on Spatial GIS Framework (공간 GIS 기반의 지반 정보 시스템 구축을 통한 대전 지역의 부지 응답에 따른 지진재해 구역화)

  • Sun, Chang-Guk
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.1
    • /
    • pp.5-19
    • /
    • 2009
  • Most of earthquake-induced geotechnical hazards have been caused by the site effects relating to the amplification of ground motion, which is strongly influenced by the local geologic conditions such as soil thickness or bedrock depth and soil stiffness. In this study, an integrated GIS-based information system for geotechnical data, called geotechnical information system (GTIS), was constructed to establish a regional counterplan against earthquake-induced hazards at an urban area of Daejeon, which is represented as a hub of research and development in Korea. To build the GTIS for the area concerned, pre-existing geotechnical data collections were performed across the extended area including the study area and site visits were additionally carried out to acquire surface geo-knowledge data. For practical application of the GTIS used to estimate the site effects at the area concerned, seismic zoning map of the site period was created and presented as regional synthetic strategy for earthquake-induced hazards prediction. In addition, seismic zonation for site classification according to the spatial distribution of the site period was also performed to determine the site amplification coefficients for seismic design and seismic performance evaluation at any site in the study area. Based on this case study on seismic zonations in Daejeon, it was verified that the GIS-based GTIS was very useful for the regional prediction of seismic hazards and also the decision support for seismic hazard mitigation.

A Study for the Evaluation of Container Modules; The Technology of Korean Container Tree Production Model (한국형 컨테이너 조경수 생산기술로서 컨테이너 모듈의 성능 평가)

  • Jung, Yong-Jo;Lim, Byung-Eul;Oh, Jang-keun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.5
    • /
    • pp.59-67
    • /
    • 2016
  • In landscape design by public institutions, although the costs and species of landscape trees stipulated by the Korean Public Procurement Service(PPS) are generally adhered to, the PPS regulations about planting trees with well-developed rootlets are almost entirely neglected. This study aimed to evaluate the performance of buried container modules, which are a new technology and product in landscape production that is able to reduce the defect rate while complying with regulations. To this end, this study measured rootlet density, rootlet development length, rootlet survival rate on excavation, and impairments of tree growth for 3 months after root pruning, and compared these variables for the container modules with those for trees that underwent root pruning in bare ground, and those that were cultivated in a container above ground. The results were as follows: First, the rootlet density was 88% for the trees in container modules, which was very high. Trees that underwent standard root pruning in bare ground had a somewhat lower density of 64%. Meanwhile, the trees that were cultivated in pots above ground died, invalidating measurement. Second, in terms of rootlet development and rootlet survival rate, the trees in container modules showed a mean length of 10.4cm, and 100% survival rate, indicating that there was no rootlet damage caused by excavation. For the trees that only underwent root pruning in bare ground, the mean length was 25.6cm and the rootlet survival rate was only half that of the trees in container modules, at 56%, demonstrating considerable damage. Rootlet development did not occur at all in the trees grown in pots. Third, the trees in container modules and those that underwent root pruning in bare ground did not show any deaths during the root pruning process, or any impairments such as stunted leaf growth. Conversely, the trees grown in pots nearly all died, and severe impairments of tree growth were observed. As shown by the results above, when we evaluated the performance of buried container modules, they showed the most outstanding performance of the three models tested in this study. The container modules prevent defects by stimulating early rooting in environments that with poor conditions for growth, or in trees that are not suited to the summer environment Therefore, it is expected that they would be an optimal means by which to enable compliance with rules such as the regulation presented by the PPS.