• Title/Summary/Keyword: performance demonstration

Search Result 398, Processing Time 0.038 seconds

Procedure Development and Qualification of the Phased Array Ultrasonic Testing for the Nuclear Power Plant Piping Weld (원자력발전소 배관 용접부 위상배열 초음파검사 절차서 개발 및 기량검증)

  • Yoon, Byung-Sik;Yang, Seung-Han;Kim, Yong-Sik;Lee, Hee-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.317-323
    • /
    • 2010
  • The manual ultrasonic examination for the nuclear power plant piping welds has been demonstrated by using KPD(Korean Performance Demonstration) generic procedure. For automated ultrasonic examination, there is no generic procedure and it should be qualified by using applicable automated equipment. Until now, most of qualified procedures used pulse-echo technique and there is no qualified procedure using phased array technique. In this study, data acquisition and analysis software were developed and phased-array transducer and wedge were designed to implement phased array technique for nuclear power plant in-service inspection. The developed procedure are qualified for performance demonstration for the flaw detection, length sizing and depth sizing. The qualified procedure will be applied for the field examination in the nuclear power plant piping weld inspection.

Round Robin Test for Performance Demonstration System of Ultrasonic Examination Personnel (초음파검사자 기량검증 체제를 위한 다자비교시험)

  • Yoon, Byung-Sik;Yang, Seung-Han;Kim, Yong-Ho;Kim, Yong-Sik;Yang, Dong-Soon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.378-383
    • /
    • 2004
  • The Korean Performance Demonstration(KPD) System for the ultrasonic testing personnel, equipments and procedures applicable to the Class 1 and 2 piping examination for nuclear power plant in Korea has been established. A round robin test was conducted in order to compare the examination results by the method of Performance Demonstration(PD) with the traditional dB-drop method. The round robin test shows that the reliability of the PD method is better than that of the dB-drop method. As a result, adoption of the PD method to the in-service inspection of the nuclear power plants will improve the reliability of the ultrasonic test results.

Thermal performance of solar cooling and hot water for the demonstration system (태양열 실증 시스템의 냉방 및 급탕 일일 열성능)

  • Lee, Ho;Kim, Sang-Jin;Joo, Hong-Jin;Kwak, Hee-Youl
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.564-569
    • /
    • 2007
  • This study describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about 350㎡ was heated and cooled with the solar system. The system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, subsidiary tank, absorption chiller, chiller storage tank, and cooling tower. The results of the experimental study indicated that the total solar energy gain as daily performance on a sunny day (August 25, 2007) with total daily radiation of $606\;W/m^2$ was 671 kWh, the collecting efficiency of 55%. In the case of supplies to heat source more than $83^{\circ}C$, cooling time operated by solar was driven 8.8 hours, cooling energy generated by solar system was 179 kWh and the solar cooling fraction was 79.2%, and hot water supplied with surplus heat source by the solar system was 201 kWh.

  • PDF

Development of an Analysis Software for the Load Measurement of Wind Turbines (풍력발전기의 하중 측정을 위한 해석 소프트웨어의 개발)

  • Gil, Kyehwan;Bang, Je-Sung;Chung, Chinwha
    • Journal of Wind Energy
    • /
    • v.4 no.1
    • /
    • pp.20-29
    • /
    • 2013
  • Load measurement, which is performed based on IEC 61400-13, consists of three stages: the stage of collecting huge amounts of load measurement data through a measurement campaign lasting for several months; the stage of processing the measured data, including data validation and classification; and the stage of analyzing the processed data through time series analysis, load statistics analysis, frequency analysis, load spectrum analysis, and equivalent load analysis. In this research, we pursued the development of an analysis software in MATLAB to save labor and to secure exact and consistent performance evaluation data in processing and analyzing load measurement data. The completed analysis software also includes the functions of processing and analyzing power performance measurement data in accordance with IEC 61400-12. The analysis software was effectively applied to process and analyse the load measurement data from a demonstration research for a 750 kW direct-drive wind turbine generator system (KBP-750D), performed at the Daegwanryeong Wind Turbine Demonstration Complex. This paper describes the details of the analysis software and its processing and analysis stages for load measurement data and presents the analysis results.

Performance Analysis of Grid-Connected PCS for PV System by Field Demonstration Test

  • So J.H.;Jung Y.S.;Yu G.J.;Jung M.W.;Kang G.H.;Choi J.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.516-519
    • /
    • 2003
  • 3kW photovoltaic (PV) systems and data acquisition system are constructed for performance analysis of PV system at field demonstration test center (FDTC) of Korea. As climatic and irradiation conditions are varied, the performance characteristics of PV system are collected and analyzed in data acquisition system. From these results, the performances of gird-connected power conditioning system (PCS) fur PV system have been evaluated and analyzed. Furthermore, performance indices of grid-connected PCS e.g. output power, efficiency, loss factor, and the other index at the site are reviewed.

  • PDF

The Effect of flow experience of online Taekwondo demonstration on participation and re-visibility : For adult women (온라인 태권도 시범 공연의 플로우(Flow) 경험이 관여도 및 재관람의도에 미치는 영향 : -성인 여성을 대상으로-)

  • Seo, Eun-Mi
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.415-424
    • /
    • 2021
  • This study aims to identify the impact of flow experience on participation and re-view of online taekwondo demonstrations on adult women, and provide practical data to revitalize online taekwondo demonstration performances, promote visitors, and promote adult taekwondo trainees. Visitors who watched the "High Kick" online taekwondo demonstration performance performed by the Kukkiwon Taekwondo Demonstration Team were selected as a population, and a total of 248 copies of the data were finally used by distributing online questionnaires. First, the difference in flow, involvement, and re-visibility due to female visitors' experiences in taekwondo is the perception, time distortion, and involvement except pleasure factors among flow sub-factors. There is a difference in the factors of re-viewing. Second, among the flow factors of online taekwondo demonstration performances, the factors of attention, pleasure, and time distortion were found to have had a positive impact on involvement. Third, the flow factor of online taekwondo demonstration shows a positive effect on the intention of re-watching. Fourth, the level of participation in online taekwondo demonstrations has a positive effect on the intention of re-watching. The results of this study suggest changes in attitudes and behavior, such as increased involvement of female visitors and intention of re-viewing, and it is believed that online performances will help establish a new non-face-to-face cultural performance system.

Generic Procedure Development for the Ultrasonic Examination of Dissimilar Metal Welds in Nuclear Power Plants (원전 이종금속 용접부 초음파 검사 일반 절차서 개발)

  • Yang, Seung Han;Kim, Yong Sik;Yoon, Byung Sik;Guon, Kee Il
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • To enhance the reliability of ultrasonic testing system, MOST(Ministry of Science and Technology) bulletin 2004-13 was published in 2004.6 requiring performance demonstration in ultrasonic examination and MEST(Ministry of Education, Science and Technology) 2009-37 was published in 2009.9(formerly MOST bulletin 2004-13). In order to meet the MEST bulletin requirement and increase the reliability of ultrasonic testing, all the ultrasonic examination procedure and equipment should be performance demonstrated and qualified. In this paper, generic procedure for the ultrasonic examination of dissimilar metal welds are described and new technique are introduced.

  • PDF

Performance Analysis of 3kW Grid-Connected PV System (3kW급 계통연계형 태양광발전시스템의 성능 비교분석)

  • So J.H.;Jung Y.S.;Yu G.J.;Lee K.O.;Choi J.Y.;Ahn H.S
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.707-710
    • /
    • 2003
  • 3kW grid-connected photovoltaic (PV) system and data acquisition system are constructed for performance analysis of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data acquisition system. From these results, the performances of PV system have simulated and evaluated using simulation tool in comparison with actual value of data acquisition system of field demonstration test center. Furthermore, performance of total PV system e.g. electric power and loss factor at the site are reviewed.

  • PDF

Daylighting Performance Evaluation of Lightshelf Window System by Lightscape (Lightscape를 이용한 광선반 창호시스템의 채광성능평가)

  • Moon, Ki Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.45-52
    • /
    • 2004
  • Simulation of daylighting by computer program is a method to avoid unnecessary efforts in manufacture of its testing models, to reduce its measuring tolerances and be able to provide variations of various weather conditions as well. Many simulation programs on daylighting have been released freely or commercialized for selling, however, a demonstration of their availability and validity as a tool for evaluating daylighting performance is required since each one has its own characteristics. The objectives of this study lie in suggesting an application method of evaluation tools and demonstration of limits and characteristics so as to more easily determine the daylightingperformance in the very initial stages of planning for an arbitrary office space in which windows with daylight access are built. We produced scale model of the general light inducing type side lighting with lightshelfand ceiling, and the luminance (at 78 measuring points) and illuminance (at 84 measuring points) were measured in a clear sky. And a comparison of the measured values and the calculated values from a computer simulation using the Lightscape program was performed.

Analysis and Evaluation of 3kW Grid-Connected PV System by Field Demonstration Test (3kW급 계통연계형 태양광발전시스템의 실증시험 분석평가)

  • So, Jeong-Hoon;Yu, Gwon-Jong;Jung, Myung-Woong;Jung, Young-Seok;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1353-1355
    • /
    • 2003
  • Total six units of 3kW photovoltaic (PV) system and data acquisition system (DAS) are constructed for analyzing performance of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data-acquisition system. Furthermore, not only performance test of each PV system component such as PV module and power conditioning system, but also performance of total PV system e.g. system efficiency, electric power and loss factor at the site are reviewed.

  • PDF