• Title/Summary/Keyword: performance criteria

Search Result 3,095, Processing Time 0.035 seconds

A Comparison Study on the Error Criteria in Nonparametric Regression Estimators

  • Chung, Sung-S.
    • Journal of the Korean Data and Information Science Society
    • /
    • v.11 no.2
    • /
    • pp.335-345
    • /
    • 2000
  • Most context use the classical norms on function spaces as the error criteria. Since these norms are all based on the vertical distances between the curves, these can be quite inappropriate from a visual notion of distance. Visual errors in Marron and Tsybakov(1995) correspond more closely to "what the eye sees". Simulation is performed to compare the performance of the regression smoothers in view of MISE and the visual error. It shows that the visual error can be used as a possible candidate of error criteria in the kernel regression estimation.

  • PDF

Synthesis of robust linear quadratic regulator (Robust linear quadratic regulator의 설계)

  • 김종철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.275-280
    • /
    • 1986
  • 본 연구는 LQR을 Robust하게 설계하는 방법을 다루었다. Unstructured Perturbation에 대응하기 좋으며 쉽게 다룰 수 있는 주파수 응답형 LQR criteria 선정법과, LQR의 변형으로서 Structured Perturbation에 대하여 유효한 Performance Criteria Insensitive Control을 제시하고 효과를 살펴보았다.

  • PDF

A Development of performance criteria tool for lightweight dry wall (건식경량벽체 요구성능 도출 도구 개발에 관한 연구)

  • Ji, Suk-won;Yoon, Sang-chun;Choi, Soo-kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.215-216
    • /
    • 2019
  • The following conclusions were reached through the research on the development of the required performance extraction tools for the application and utilization of various construction methods of lightweght dry wall. 1) Performance required for walls of apartment buildings can be divided into safety, habitation, durability and productivity. Among these, horizontal load resistance, shock resistance, anti-seismic performance, insulation, and acoustic characteristics are the main performance that correspond to dry walls. In addition, safety related to toxic gases and contaminants are required according to recent eco-friendly requirements. 2) To select a wall according to the required performance of an inner wall applied to an apartment, a map tool in the form of 2D matrices was constructed to enable the required performance to be applied, indicating that the wall location and wall material and its differentiating according to the old method.

  • PDF

DC-Suppression Selection Criteria of Multimode Modulation Code for Optical Recording (광 기록 시스템을 위한 멀티모드 변조 코드의 DC-억압 코드 선택 방법)

  • Lee, Myoung-Jin;Lee, Jun;Lee, Jae-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.3C
    • /
    • pp.209-214
    • /
    • 2003
  • Multi-mode coding method is a reliable DC-suppression method. There are two ways to improve the DC-suppression performance. One is improving scrambler's performance, and the other is improving selection criteria. The latter uses the MRDS(minimum running digital sum) criterion. It is easy to calculate, but its performance goes down when the length of codeword is getting longer. The MSW(mean squared weight) criterion that is known as the best so far regardless of the length of codeword has the high complexity. In this paper, we present the new selection criteria, MPRDS(minimum peak RDS) and A BSRDS(absolute RDS). Their performance are close to the MSW, implementation is simple. And also we present the SC(sign change) that has a subsidiary role with the original selection criteria and improve the capacity.

The Optimization Study on the Test Method of Remanufactured Power Steering Oil Pump by Using FMEA (FMEA를 활용한 재제조 파워스티어링 오일펌프 시험법에 대한 최적화 연구)

  • Seo, Youngkyo;Jung, Dohyun;Yu, Sangseok;Rha, Wanyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.90-98
    • /
    • 2016
  • Currently government certified test method for an automobile remanufactured products is insufficient. Thus many automotive parts in the remanufacturing market are lacking proper evaluation criteria and production of defective products are causing customer dissatisfaction. In this paper a power steering oil pump, which requires stringent manufacturing standards, is studied by the failure mode and effect analysis approach. The research suggested that the test criteria such as discharge flow characteristic test, tightness test, pulley run-out test, pressure switch operation test, low temperature test and rotation pressure durability test should be performed to evaluate the reliability of remanufactured power steering oil pumps. As a result of tests, the performance of remanufactured power steering oil pump satisfied the evaluation criteria of pressure switch operation test and low temperature test. However, the remanufactured power steering oil pump failed to satisfy the evaluation criteria on discharge performance test, tightness test and pulley run-out test. These performance evaluation tests proved the necessity of standard process for the remanufactured power steering oil pump.

A Study on the Fire Resistance Design of Buildings Considering the Fire Load Energy Density (화재하중밀도를 고려한 건축물의 내화설계법에 관한 연구)

  • 이평강;이용재;최인창;김회서
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2003
  • The main purpose of this study is to raise the point at issue and to propose reform direction about the current performance criteria of fire resistance through the examination of the fire resistance required for each use of compartment by using performance-based fire safety design method. To examine the performance criteria of fire resistance, this study compared the equivalent time of fire exposure which was calculated by using time-equivalent formulae with the required fire resistance time determined by existing prescriptive code, and surveyed factors such as the fire load energy density, ventilation factor, fire compartment materials and fire compartment geometry in order to calculate the equivalent time of fire exposure.

Design Criteria and Performance of Space-Frequency Bit-Interleaved Coded Modulations in Frequency-Selective Rayleigh Fading Channels

  • Park, Dae-Young;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • v.5 no.2
    • /
    • pp.141-149
    • /
    • 2003
  • In this paper, we investigate design criteria and the performance of the space-frequency bit-interleaved coded modulation (SF-BICM) systems in frequency-selective Rayleigh fading channels. To determine the key parameters that affect the performance of SF-BICM, we derive the pairwise error probability (PEP) in terms of the determinant of the matrix corresponding to any two codewords. We prove that the bit-interleavers do the function of distributing the nonzero bits uniformly such that two or more nonzero bits are seldom distributed into the symbols that are transmitted in the same frequency bin. This implies that the bit-interleavers transform an SF-BICM system into an equivalent 1-antenna system. Based on this, we present design criteria of SFBICM systems that maximizes the diversity order and the coding gain. Then, we analyze the performance of SF-BICM for the case of 2-transmit antennas and 2-multipaths by deriving a frame error rate (FER) bound. The derived bound is accurate and requires only the distance spectrum of the constituent codes of SF-BICM. Numerical results reveal that the bound is tight enough to estimate the performance of SF-BICM very accurately.

Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1 (사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용)

  • Jung, Hwansuk;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.

A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size (창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석)

  • Kim, Seong-Beom;Lee, Su-Yeul;Kim, Dong-Yoon;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

A Study on the Development of Performance Audit Model Using the System Dynamics (시스템다이내믹스 기법을 이용한 공공정책 성과감사 모형개발에 관한 연구)

  • Choi, Nam-Hee
    • Korean System Dynamics Review
    • /
    • v.12 no.3
    • /
    • pp.25-46
    • /
    • 2011
  • Recently, performance auditing system of governmen is carried out as most promising framework of government audit. Performance audit by the Board of Audit and Inspection of Korea involves assessing the causes and effects of government policies, programs, and Institutions with the criteria of economy, efficiency, effectiveness. Performance auditing will contribute to strengthening the values of objective assessments of whether public resources are responsibly and effectively managed to achieve intended results. Nevertheless, there seems to be a problems appears in implementation of audit. That is the problems of tendency return to legitimacy audit which is result from the lack of strong approach and methodology. So, this study purpose to developing stronger audit concepts and methods that add to the process and framework of traditional performance auditing system. First, this study evaluates the limitation of current performance auditing system with the perspective of systems thinking. Second, this study analyzes the process and method of current system and develop the conceptual model of the Dynamics Audit System using the system dynamics methodology, which focused on the appropriate auditing process and framework.

  • PDF