• Title/Summary/Keyword: performance based evaluation

Search Result 6,791, Processing Time 0.042 seconds

A Study on the Effects of Relationship Between Copper Crusher Gauge and Internal Piezo Gauge (강내압력측정 신뢰성 확보 방안에 관한 연구: 동구게이지와 IPG 게이지 성능 비교 중심)

  • Jung, Min-Cheol;Lee, Jeong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.120-127
    • /
    • 2020
  • This study examined the operation of a pressure gauge for measuring the internal pressure of a barrel. During the ammunition performance evaluation test, the internal pressure of the barrel was measured mainly using a copper crusher gauge. The internal piezo gauge (IPG) was used to replace the pressure measurement method, and the test results were analyzed to verify the operability of the IPG. For verification, actual shooting test data were used, and a t-test was used to analyze the results. The 155MM KH179 and M119 series propellant were used for the test equipment and ammunition. The results confirmed that there was no difference between the mean values of the two data results at a significance level of 5% for the data values between the copper gauge and the IPG. The use of the IPG was verified by replacing the existing copper gauge to measure the internal pressure of the barrel, and it was confirmed that the application width could be widened in terms of diversity of test measurement methods. Based on the results of this test, it can be applied to the compression measurement test of various types of ammunition in addition to the propellant charges.

A Case Study on the Development of Suwon Village in ODA Project in Cambodia (캄보디아 ODA 수원마을 조성사업에 관한 사례 연구)

  • KANG, YONG-KYU
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.548-558
    • /
    • 2020
  • This study presents improvement measures at the local government level by analyzing the step-by-step projects of Suwon City's Suwon Village Development Project, which is being carried out with public development assistance in the Kingdom of Cambodia. For this study, realistic research was conducted by visiting the site and interviewing the person in charge. The following conclusions are drawn. First, public development assistance projects for local governments in Korea should be carried out, with detailed programs to implement them under the central government's ODA policy. Second, provided a project is competitively carried out, and is not simply pork barreling or enhancing the external image of local governments, the project should be continued, and supplementary measures taken based on an evaluation system and the results of the project's performance. Third, ODAs in the economic and social development sectors-not sporadic aid among central government ministries and local governments-should be centered on the central government and KOICA while local governments are small. If development cooperation is achieved by focusing on the software sector, criticism that it wastes taxpayers' money is likely to decrease. This study suggests that local governments need to establish ODA plans and cooperate with the central government.

Seismic Performance Evaluation of R/C Frame Apartment Strengthened with Kagome Truss Damper External Connection Method by Pseudo Dynamic Test (유사동적실험에 의한 외부접합형 카고메 트러스 제진장치가 설치된 RC 라멘조 공동주택의 내진성능 평가)

  • Heur, Moo-Won;Chun, Young-Soo;Hwang, Jae-Seung;Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.23-34
    • /
    • 2015
  • Recently a new damper system with Kogome truss structure was developed and its mechanical properties were verified based on the laboratory test. This paper presents a Kagome truss damper external connection method for seismic strengthening of RC frame structural system. The Kagome external connection method, proposed in this study, consisted of building structure, Kagome damper and support system. The method is capable of reducing earthquake energy on the basis of the dynamic interaction between external support and building structures using Kagome damper. The pseudo-dynamic test, designed using a existing RC frame apartment for pilot application of LH corporation, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and response ductility. Test results revealed that the proposed Kagome damper method installed in RC frame enhanced conspicuously the strength and displacement capacities, and the method can resist markedly under the large scaled earthquake intensity level.

A Valuation for Gas Hydrate R&D Project Using Fuzzy Real Options Model (퍼지실물옵션모형을 이용한 가스하이드레이트 R&D 사업의 가치평가)

  • Yun, Ga-Hye;Heo, Eunnyeong
    • Environmental and Resource Economics Review
    • /
    • v.18 no.2
    • /
    • pp.217-239
    • /
    • 2009
  • As gas hydrate is recently emerging as a new energy source to solve environmental and exhaustion problems caused by fossil energy, Korea is working on a gas hydrate development project under a 10-year plan from 2005 to 2014. Gas hydrate is expected to have a big effect on the economy and society of Korea, which is largely depending on energy imports besides water energy and atomic energy. However, it is uncertain whether the project will produce successful results. Thus, it is very important to improve its validity and to propose effective execution strategies by evaluating the value of the project in advance. Thus, this study intended to include new information, which had not been evaluated in existing methods, and to reduce biases or errors in value evaluation results by applying a fuzzy risk analysis to the real option model in order to evaluate the value of a gas hydrate development project. It is advantageous that the real option model based on the fuzzy risk analysis modelizes the vagueness and inexactness of intangible element judgment into an appropriate language scale so as to evaluate these elements clearly and integrate them with estimated financial performance results. The application of the fuzzy risk analysis makes it possible to conduct an analysis by dissolving a decision-making issue with complicated and various attributes into several simplified problems. With the continuing high oil prices and today's demand of clean energy, the necessity of energy resources and technology development projects keeps growing. Amid this situation, it is expected that these study results will contribute to proposing a guideline not only for gas hydrate projects but also for policy decision-making related to future energy industries.

  • PDF

Development of a Voice-activated Map Information Retrieval System based on MFC (MFC 기반 음성구동 수치지도정보 검색시스템의 구현)

  • Kim, Nag-Cheol;Kim, Tae-Soo;Jo, Myung-Hee;Chung, Hyun-Yeol
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.1
    • /
    • pp.69-77
    • /
    • 2000
  • In retrieving and analyzing digital map information using mouse or key strokes, it needs several times of repeated mouse operation for designating the range of study area. In this study, we proposed a voice activated map information retrieval system for eliminating such repetitions and we realized the system on the personal computer. The system was constructed in two ways - traditional OLE(object linking embedding) method and MFC(Microsoft fundamental class) method in controlling of window display for practical use. In the system performance evaluation, the retrieval data for digital map were consisted of 68 words uttered by 3 male persons which include attribute words and control words for Susung-gu area of Taegu city in a 1:5,000 map. As the results, we obtained the average 98.02% of recognition rate through on-line tests in the office environment and the operating speed of 5.39 seconds by OLE, 10.38 seconds by MFC. These results showed the possibility for practical use of information retrieval system using speech recognition in digital map.

  • PDF

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

Comprehensive Development Plans for the Low- and Intermediate-Level Radioactive Waste Disposal Facility in Korea and Preliminary Safety Assessment (우리나라 중·저준위 방사성폐기물 처분시설 종합개발계획(안)과 예비안전성평가)

  • Jung, Kang Il;Kim, Jin Hyeong;Kwon, Mi Jin;Jeong, Mi Seon;Hong, Sung Wook;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.385-410
    • /
    • 2016
  • The disposal facility in Gyeongju is planning to dispose of 800,000 packages of low- and intermediate- level radioactive waste. This facility will be developed as a complex disposal facility that has various types of disposal facilities and accompanying management. In this study, based on the comprehensive development plan of the disposal facility, a preliminary post-closure safety assessment is performed to predict the phase development of the total capacity for the 800,000 packages to be disposed of at the site. The results for each scenario meet the performance target of the disposal facility. The assessment revealed that there is a significant impact of the inventory of intermediate-level radionuclide waste on the safety evaluation. Due to this finding, we introduce a disposal limit value for intermediate-level radioactive waste. With stepwise development of safety case, this development plan will increase the safety of disposal facilities by reducing uncertainties within the future development of the underground silo disposal facilities.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Seasonal Effects Removal of Unsupervised Change Detection based Multitemporal Imagery (다시기 원격탐사자료 기반 무감독 변화탐지의 계절적 영향 제거)

  • Park, Hong Lyun;Choi, Jae Wan;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.2
    • /
    • pp.51-58
    • /
    • 2018
  • Recently, various satellite sensors have been developed and it is becoming more convenient to acquire multitemporal satellite images. Therefore, various researches are being actively carried out in the field of utilizing change detection techniques such as disaster and land monitoring using multitemporal satellite images. In particular, researches related to the development of unsupervised change detection techniques capable of extracting rapidly change regions have been conducted. However, there is a disadvantage that false detection occurs due to a spectral difference such as a seasonal change. In order to overcome the disadvantages, this study aimed to reduce the false alarm detection due to seasonal effects using the direction vector generated by applying the $S^2CVA$ (Sequential Spectral Change Vector Analysis) technique, which is one of the unsupervised change detection methods. $S^2CVA$ technique was applied to RapidEye images of the same and different seasons. We analyzed whether the change direction vector of $S^2CVA$ can remove false positives due to seasonal effects. For the quantitative evaluation, the ROC (Receiver Operating Characteristic) curve and the AUC (Area Under Curve) value were calculated for the change detection results and it was confirmed that the change detection performance was improved compared with the change detection method using only the change magnitude vector.

A Real-Time Multiple Circular Buffer Model for Streaming MPEG-4 Media (MPEG-4 미디어 스트리밍에 적합한 실시간형 다중원형버퍼 모델)

  • 신용경;김상욱
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.1
    • /
    • pp.13-24
    • /
    • 2003
  • MPEG-4 is a standard for multimedia applications and provides a set of technologies to satisfy the needs of authors, service providers and end users alike. In this paper, we suggest a Real-time Multiple Circular Buffer (M4RM Buffer) model, which is suitable for streaming these MPEG-4 contents efficiently. M4RM buffer generates each structure of the buffer, which matches well with each object composing an MPEG-4 content, according to the transferred information, and manipulates multiple read/write operations only by its reference. It divides the decoder buffer and the composition buffer, which are described in the standard, by the unit of frame allocated to minimize the range of access. This buffer unit of a frame is allocated according to the object description. Also, it processes the objects synchronization within the buffer and provides APIs for an efficient buffer management to process the real-time user events. Based on the performance evaluation, we show that M4RM buffer model decreases the waiting time in a buffer frame, and so allows the real-time streaming of an MPEG-4 content using the smaller size of the memory block than IM1-2D and Window Media Player.