• 제목/요약/키워드: perforated wall

검색결과 100건 처리시간 0.028초

초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 요철이 설치된 유출면에서의 열/물질전달 특성 (Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow)

  • 이동호;남용우;조형희
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.338-348
    • /
    • 2004
  • The present study is conducted to investigate the effect of rib arrangements on an impingement/effusion cooling system with initial crossflow. To simulate the impingement/effusion cooling system, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of tile hole diameter. Initial crossflow passes between the injection and effusion plates, and the square ribs (3mm) are installed on the effusion plate. Both the injection and effusion hole diameters are 10mmand Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effects of rib arrangements, various rib arrangements, such as 90$^{\circ}$transverse and 45$^{\circ}$angled rib arrangements, are used. Also, the effects of flow rate ratio of crossflow to impinging jets are investigated. With the initial crossflow, locally low transfer regions are formed because the wall jets are swept away, and level of heat transfer rate get decreased with increasing flow rate of crossflow. When the ribs are installed on the effusion plate, the local distributions of heat/mass transfer coefficients around the effusion holes are changed. The local heat/mass transfer around the stagnation regions and the effusion holes are affected by the rib positions, angle of attack and rib spacing. For low blowing ratio, the ribs have adverse effects on heat/mass transfer, but for higher blowing ratios, higher and more uniform heat transfer coefficient distributions are obtained than the case without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. Average heat transfer coefficients with rib turbulators are approximately 10% higher than that without ribs, and the higher values are obtained with small pitch of ribs. However, the attack angle of the rib has little influence on the average heat/mass transfer.

평행평판 도파관의 윗면에 위치한 주기적인 슬롯 배열에 의한 전자파의 회절특성 (Diffraction Properties from Periodic Slot Array in the Upper Wall of Parallel Plate Waveguide)

  • 박진택;홍재표;고지환;조영기
    • 한국전자파학회논문지
    • /
    • 제16권3호
    • /
    • pp.311-318
    • /
    • 2005
  • 평행평판 도파관의 윗면에 2차원적 주기적인 슬롯이 배열된 구조에서 회절특성에 중점을 두어 해석하였다. 주기적인 슬롯배열은 한 축은 무한 슬롯 배열로 두고 다른 축은 유한개의 슬롯 배열로 구성된다. 평행편판 도파관 내부로 입사되는 전자파는 일부 반사되고 일부는 슬롯을 통하여 복사되며 나머지는 주기적인 슬롯이 있는 영역을 넘어 투과하게 된다. 이러한 경우에 평행평판 도파관의 높이, 단일 슬롯의 크기, 그리고 슬롯 배열의 주기에 따라 반사, 복사 그리고 투과되는 전력을 수치 계산하여 살펴보았다. 이러한 연구는 TFT-LCD와 PDP 구조의 됫면에 장착되는 주기적인 원형개구 구조를 이용하는 환기구조 설계에 유익할 것으로 사료된다.

무창 분만 ${\cdot}$ 자돈사 환기 형태가 돈사내 환경에 미치는 영향 (Effects of Ventilation Types on Interior Environment of the Enclosed Farrowing-Nursery Pig House)

  • 유용희;송준익;강희설;전병수;김태일;김형호
    • 한국축산시설환경학회지
    • /
    • 제8권2호
    • /
    • pp.79-86
    • /
    • 2002
  • This study was conducted to collect basic data about the effects of ventilation types on the interior environment of the enclosed farrowing-nursery pig house in Anseong, Icheon and Jeungpyong. Surveyed ventilation types in the enclosed farrowing-nursery pig house are classified in to 4 types. In V1 type, air enters through a planar slot inlet placed on the juncture of the entering wall and exit through the chimney fan outlet; in V2 type, air enters through a perforated ceiling inlet and exits chimney fan outlet(V2); in V3 type, air enters through a circular duct inlet and exit chimney fan outlet(V3); in V4 type, enters through a circular duct inlet and exits side wall exhaust fan outlet(V4). Temperature, relative humidity, air velocity and ammonia concentration($NH_3$) were measured in the interior of swine building in the summer. Interior temperature was not remarkably different in all ventilation types in this study. However, temperature of the V4 was somewhat lower than that of the other types. Air velocity of the V4 was higher and $NH_3$ concentration of the V4 was lower than those of other ventilation types. It is suggested that the V4 ventilation type be applicable in the enclosed farrowing-nursery pig house in Korea.

  • PDF

다공확장벽을 이용한 미사일 동체에 대한 플룸간섭 현상의 제어 (Control of Plume Interference Effects on a Missile Body Using a Porous Extension)

  • Young-Ki Lee;Heuy-Dong Kim
    • 한국추진공학회지
    • /
    • 제7권4호
    • /
    • pp.33-38
    • /
    • 2003
  • 플룸간섭 현상은 플룸에 의한 경계층 유동의 박리, 강한 전단층의 발생, 그리고 다수의 충격파들이 박리유동 및 전단층과 상호작용하게 되는 매우 복잡한 유동현상으로, 현재 미사일의 후미부에서 발생하는 플룸간섭 현상의 상세에 관해서는 잘 알려져 있지 않다. 본 연구에서는 초음속 미사일의 동체후미부에서 발생하는 플룸간섭 현상의 특징 및 동체기저부에 설치된 다공확장벽(porous extension)의 플룸간섭 현상에 대한 영향을 수치해석적으로 조사하였다. 그 결과, 다공확장벽이 플룸에 의한 충격파와 경계층 유동의 박리를 완화시켜 미사일 동체의 제어성능이 향상될 수 있음을 알았다.

초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 원형핀이 설치된 유출면에서의 열/물질전달 특성 (Heat/Mass Transfer on Effusion Plate with Circular Pin Fins for Impingement/Effusion Cooling System with Intial Crossflow)

  • 홍성국;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.828-836
    • /
    • 2005
  • Impingement/effusion cooling technique is used for combustor liner or turbine parts cooling in gas turbine engine. In the impingement/effusion cooling system, the crossflow generated in the cooling channel induces an adverse effect on the cooling performance, which consequently affects the durability of the cooling system. In the present study, to reduce the adverse effect of the crossflow and improve the cooling performance, circular pin fins are installed in impingement/effusion cooling system and the heat transfer characteristics are investigated. The pin fins are installed between two perforated plates and the crossflow passes between these two plates. A blowing ratio is changed from 0.5 to 1.5 for the fixed jet Reynolds number of 10,000 and five circular pin fin arrangements are considered in this study. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The results show that local distributions of heat/mass transfer coefficient are changed due to the installation of pin fins. Due to the generation of vortex and wake by the pin fin, locally low heat/mass transfer regions are reduced. Moreover, the pin fin prevents the wall jet from being swept away, resulting in the increase of heat/mass transfer. When the pin fin is installed in front of the impinging let, the blockage effect on the crossflow enhances the heat/mass transfer. However, the pin fin installed just behind the impinging jet blocks up the wall jet, decreasing the heat/mass transfer. As the blowing ratio increases, the pin fins lead to the higher Sh value compared to the case without pin fins, inducing $16\%{\~}22\%$ enhancement of overall Sh value at high blowing ratio of M=1.5.

연암부 벽면거칠기를 이용한 단위주면마찰력 특성에 관한 연구 (A Study on Characteristics of the Unit Skin Friction Using the Wall Roughness in the Soft Rock)

  • 홍석우;황근배
    • 한국지반공학회논문집
    • /
    • 제35권12호
    • /
    • pp.7-13
    • /
    • 2019
  • 현장타설말뚝인 경우에 연암 소켓부의 단위주면마찰응력을 산정하는 방법 중 벽면 거칠기에 의한 산정 방법이 있다. 이 방법은 현장타설말뚝을 시공하기 위한 굴착 단계에서 거칠기 측정 장치를 굴착공에 설치하여 암반 벽면의 거칠기 양상을 측정하여 주면마찰력을 산정하는 것이다. 본 연구에서는 현장타설말뚝의 암반 소켓부 벽면의 거칠기 양상을 천공홀에서 직접 측정하였으며 그 결과를 이용하여 암반의 주면마찰력 특성을 파악하고자 한다. 그리고, 거칠기 시험 결과를 검증하기 위하여 동일 말뚝에 정재하시험 및 하중전이시험을 수행하였다.

황토를 이용한 친환경 유공 흡음보드의 흡음특성 (Absorption Characteristics of Perforated Environment Friendly Sound Absorbing Board using Hwangto)

  • 김선우;박현구
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.3-8
    • /
    • 2011
  • Sound absorbing materials used for lightweight panels and interior material are mainly made of fibroid material such as glass wool or rock wool. However these fiber type sound absorbing materials have some problems such that sound absorption could be decreased as time goes by because of durability. In addition, dust scattering from fiber type material can cause another problem in health. In this point of view, this study aims to develop environment friendly sound absorbing material using Hwangto(so called loess or yellow soil), a traditional housing material. Hwangto is natural housing material in Korea and generally known for improving indoor air quality. Hwangto panel is made to construct on the floor, wall and ceiling, and expected that there is not enough absorption. Present study tried to develop environment friendly sound absorbing material that has high sound absorption performance with good environment performance in terms of air quality. Pore rate was designed to maximize the absorption in the specific frequency bands, and two kinds of backing space were applied in order to see the effect of backing space. As a result peak frequency that has maximum absorption is going high as the pore rate is increased. The backing space provides more absorption and makes the peak frequency down to low.

소파케이슨 방파제의 기대활동량 산정 (Calculation of Expected Sliding Distance of Wave Dissipating Caisson Breakwater)

  • 김동현
    • 한국해안해양공학회지
    • /
    • 제17권4호
    • /
    • pp.213-220
    • /
    • 2005
  • 소파케이슨 방파제의 기대활동량 산정방법을 제안하였다. 소파케이슨의 활동량 산정을 위해 필요한 파력의 시계열은 기존에 개발된 소파케이슨의 정적 파력모델을 동적으로 확장하여 개발하였다. 충격파와 중복파의 구성은 지속시간 및 최대파력을 이용하여 구하였다. 수치해석에서는 제안방법에 의한 소파케이슨의 1파에 대한 활동량 및 50년간의 기대활동량을 직립케이슨에 적용하는 기존방법의 결과와 비교하였다. 비고결과 제안방법에 의한 소파케이슨의 활동량은 기존방법을 적용할 때보다 감소하는 것으로 나타났다.

패시브환기외피의 통기 및 열성능에 관한 실험적 연구 (An Experimental Study on Ventilation and Thermal Performance of Passive Ventilation Building Envelopes)

  • 윤성환;이태철;강정식
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.711-717
    • /
    • 2011
  • In this study, 5 types of PVS(Passive ventilation system) units are made and experimented its ventilation performance, thermal performance according to open rate and hole diameter of perforated aluminum plane. Results are as follows. 1) The ventilation performance increases approximately 50~70% according by the open rate of PVS increasing. Also, the ventilation performance increases about 2%~12% according by the hole diameter of PVS increasing. 2) In winter temperature/pressure condition(in : $20^{\circ}C$, out : $-2^{\circ}C/{\Delta}P$ : 0.2~5.0Pa) the temperature of inflow air decreases according by the open rate of PVS increasing. Heat gain performance decreases 10.1%, 25.6% when open rate increases 3) In the same condition, Heat gain performance decreases 18.3%, 18.8% according by the hole diameter of PVS increasing.

유공벽 벽두께에 따른 에너지 손실계수의 변화 수리실험 (Hydraulic Experiment for Variation of Energy Loss Coefficient due to Thickness of Perforated Wall)

  • 권갑근;서종선;이재황;윤성범
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2011년도 학술발표회
    • /
    • pp.50-54
    • /
    • 2011
  • 공극률, 슬릿 수 및 두께가 다양한 오리피스 구조물을 대상으로 개수로 수리실험을 진행하여 유공벽의 벽두께에 따른 에너지 손실계수의 변화 및 메커니즘을 연구하였다. 오리피스의 개수로 수리실험을 수행하였으며 다양한 유속조건에서 오리피스의 벽두께에 대한 에너지 손실계수를 측정한 뒤 결과를 권 등(2010)의 관수로 실험결과와 비교하였다. 실험결과 전체적으로 유속에 따라 에너지 손실은 변화하였으며 유속이 감소할수록 에너지 손실은 크게 증가함을 보였다. 유속이 작은 층류구간에서 유속이 감소할수록 에너지 손실은 증가하는 반비례 관계를 보였고 에너지 손실량은 관수로 실험결과와 서로 비슷하였다. 그러나 유속이 강한 난류 구간에서는 에너지 손실이 유속과 무관하게 일정한 관수로 결과와는 달리 유속에 따라 변화하였다. 또한 유속이 약한 흐름에서는 오리피스의 두께 및 슬릿 수에 따라 에너지 손실은 각각 다르게 측정되었지만 유속이 강한 흐름에서는 벽두께 변화와 상관없이 에너지 손실은 거의 비슷하였다. 이 결과로부터 개수로 오리피스의 경우 유속이 강한 구간에서는 오리피스의 벽두께 효과 보다 상 하류 수위차로 발생하는 개수로 효과가 더 큰 영향을 주는 것으로 확인되었다.

  • PDF