Browse > Article
http://dx.doi.org/10.3795/KSME-B.2004.28.3.338

Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow  

Rhee, Dong-Ho (연세대학교 대학원)
Nam, Yong-Woo (연세대학교 대학원)
Cho, Hyung-Hee (연세대학교 기계공학과)
Publication Information
Transactions of the Korean Society of Mechanical Engineers B / v.28, no.3, 2004 , pp. 338-348 More about this Journal
Abstract
The present study is conducted to investigate the effect of rib arrangements on an impingement/effusion cooling system with initial crossflow. To simulate the impingement/effusion cooling system, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of tile hole diameter. Initial crossflow passes between the injection and effusion plates, and the square ribs (3mm) are installed on the effusion plate. Both the injection and effusion hole diameters are 10mmand Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effects of rib arrangements, various rib arrangements, such as 90$^{\circ}$transverse and 45$^{\circ}$angled rib arrangements, are used. Also, the effects of flow rate ratio of crossflow to impinging jets are investigated. With the initial crossflow, locally low transfer regions are formed because the wall jets are swept away, and level of heat transfer rate get decreased with increasing flow rate of crossflow. When the ribs are installed on the effusion plate, the local distributions of heat/mass transfer coefficients around the effusion holes are changed. The local heat/mass transfer around the stagnation regions and the effusion holes are affected by the rib positions, angle of attack and rib spacing. For low blowing ratio, the ribs have adverse effects on heat/mass transfer, but for higher blowing ratios, higher and more uniform heat transfer coefficient distributions are obtained than the case without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. Average heat transfer coefficients with rib turbulators are approximately 10% higher than that without ribs, and the higher values are obtained with small pitch of ribs. However, the attack angle of the rib has little influence on the average heat/mass transfer.
Keywords
Impingement/Effusion Cooling; Initial Crossflow; Rib Turbulator; Heat and Mass Transfer Analogy;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 3-D Numerical Simulation of Impinging Jet Cooling with Initial Crossflow /
[ Haiping,C.;Wanbing,C.;Taiping,H. ] / ASME Paper No.99-GT-256
2 Haiping, C., Wanbing, C. and Taiping, H., 1999, '3-D Numerical Simulation of Impinging Jet Cooling with Initial Crossflow,' ASME Paper No. 99-GT-256
3 Yoon, P. H., Rhee, D. H. and Cho, H. H., 2001, 'Flow and Heat/Mass Transfer Characteristics of Arrays of Impingement Jets with Effusion Holes,' Trans of KSME (B), Vol. 25, No. 11, pp. 1606-1615   과학기술학회마을
4 Rhee, D. H., Choi, J. H. and Cho, H. H., 2002, 'Flow and Heat (Mass) Transfer Characteristics in an Impingement/Effusion Cooling System with Crossflow,' J. of Turbomachinery, Vol. 125, pp. 74-82   과학기술학회마을   DOI
5 Gau, C. and Lee, C. C., 1992, 'Impingement Cooling Flow Structure and Heat Transfer Along Rib-Roughened Walls,' Int. J. of Heat Mass Transfer, Vol. 35, pp. 3009-3020   DOI   ScienceOn
6 Lee, D. H., Won, S. Y. and Lee, J. S., 1999, 'Heat Transfer Measurement by a Round Jet Impinging on a Rib-Roughened Concave Surface,' Trans of KSME (B), Vol. 23, No. 6, pp. 734-743
7 Chung, Y. S., Lee, D. H. and Lee, J. S., 1998, 'Heat Transfer Coefficient Measurement by a Jet Impinging on a Rib-Roughened Convex Surface,' Trans of KSME (B), Vol. 22, No. 3, pp. 373-385   과학기술학회마을
8 Cho, H. H. and Goldstein, R. J., 1995, 'Heat (Mass) Transfer and Film Cooling Effectiveness with Injection through Discrete Holes Part I: within holes and on the back surface,' J. of Turbomachinery, Vol. 117, pp. 440-450   DOI
9 Haiping, C., Dalin, Z., Dong, H. and Taiping, H., 1996, 'Experimental investigation on Impingement Heat Transfer from Rib roughened surface within Arrays of circular jet: Effect of Geometric Parameters,' ASME Paper No. 98-GT-208
10 Han, J. C., Chandra, P. R. and Lau, S. C., 1988, 'Local Heat/Mass Transfer Distributions Around Sharp 180 Deg Turns in Two-Pass Smooth and Rib-Roughened Channels,' J. Heat Transfer, Vol. 110, pp. 91-98   DOI
11 Goldstein, R. J. and Cho, H. H., 1995, 'A Review of Mass Transfer Measurement Using Naphthalene Sublimation,''Exp. Thermal and Fluid Science, Vol. 10, pp. 416-434   DOI   ScienceOn
12 Ekkad, S. V. and Han, J. C., 1997, 'Detailed Heat Transfer Distribution in Two-pass Square Channels with Rib Turbulators,' Int. J. of Heat Mass Transfer, Vol. 40, No. 11, pp. 2525-2537   DOI   ScienceOn
13 Cho, H. H., Wu, S. J., and Kwon, H. J., 2000, 'Local Heat/Mass Transfer Measurements in a Rectangular Duct with Discrete Ribs,' J. of Turbomachinery, Vol. 122, pp. 579-586   DOI
14 Chandra, P. R., Han, J. C. and Lau, S. C., 1988, 'Effect of Rib Angle on Local Heat /Mass Transfer Distribution in a Two-Pass Rib- Roughened Channel,' J. of Turbomachinery, Vol. 110, pp. 233-241   DOI
15 Taslim, M. E. and Spring, S. D., 1994, 'Effects of Turbulator Profile and Spacing on Heat Transfer and Friction in a Channel,' J. of Thermophysics and Heat Transfer, Vol. 8, No. 3, pp. 555-562   DOI   ScienceOn
16 Liou, T. M. and Hwang, J. J., 1993, 'Effect of Ridge Shapes on Turbulent Heat Transfer and Friction in a Ractangular Channel,' Int. J. of Heat Mass Transfer, Vol. 36, No. 4, pp. 931-940   DOI   ScienceOn
17 Kline, S. J., and McClintock, F. A., 1953, 'Describing Uncertainty in Single-Sample Experiments,' Mechanical Engineering, Vol. 75, pp. 3-8   과학기술학회마을
18 Choi, C. C., Rhee D. H. and Cho H. H., 2002, 'Heat/Mass Transfer and Pressure Drop in A Square Duct with V-Shaped Ribs,' Trans of KSME (B), Vol. 26, No. 11, pp. 1542-1551   과학기술학회마을   DOI
19 Hollwarth, B. R. and Dagan, L., 1980, 'Arrays of Impinging Jets with Spent Fluid Removal through Vent Holes on the Target Surface Part 1: Average Heat Transfer,' J. of Engineering for Power, Vol. 102, pp. 994-999   DOI
20 Eckert, E. R. G., 1976, 'Analogies to Heat Transfer Processes, in Measurements in Heat Transfer,' ed. Eckert, E. R. G. and Goldstein, R. J., Hemisphere Pub., New York, pp. 397-423
21 Metzger, D. E. and Korstad, R. J., 1992, 'Effects of Cross flow in Impingement Heat Transfer,' J. of Engineering for Power, Vol. 94, pp. 35-41
22 Cho, H. H. and Rhee, D. H., 2001, 'Local Heat/Mass Transfer Measurement on the Effusion Plate in Impingement/Effusion Cooling System,' J. of Turbomachinery, Vol. 123, pp. 601-608   DOI
23 Hollwarth, B. R. and Lehmann, G. and Rosiczkowski, J., 1983, 'Arrays of Impinging Jets with Spent Fluid Removal through Vent Holes on the Target Surface Part 2: Local Heat Transfer,' J. of Engineering for Power, Vol. 105, pp. 393-402   DOI
24 Cho, H. H. and Goldstein, R. J., 1996, 'Effect of Hole Arrangements on Impingement/ Effusion Cooling,''Proceeding of the 3rd KSME-JSME Thermal Engineering Conference, pp. 71-76
25 Yoon, P. H., Rhee, D. H. and Cho, H. H., 2000, 'Effect of Arrays of Impinging Jets with Crossflow on Heat/Mass Transfer,' Trans of KSME (B), Vol. 24, No. 2, pp. 195-203   과학기술학회마을
26 Florschuetz, L. W., Metzger, D. E. and Su, C. C., 1984, 'Heat Transfer Characteristics for Jet Array Impingement With Initial Crossflow,''J. of Heat Transfer, Vol. 106, pp. 34-41   DOI
27 Cho, H. H., Choi, J. H. and Rhee, D. H. 2001, 'The Effects of Hole Arrangements on Heat/Mass Transfer of Impingement/Effusion Cooling System,' Proceedings of ExHFT-5, pp. 975-980