• 제목/요약/키워드: perfobond rib

검색결과 33건 처리시간 0.02초

Concrete-filled rectangular hollow section X joint with Perfobond Leister rib structural performance study: Ultimate and fatigue experimental Investigation

  • Liu, Yongjian;Xiong, Zhihua;Feng, Yuncheng;Jiang, Lei
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.455-465
    • /
    • 2017
  • This paper presents a series of ultimate and fatigue experimental investigation on concrete-filled rectangular hollow section (CRHS) X joints with Perfobond Leister rib (PBR) under tension. A total of 15 specimens were fabricated, in which 12 specimens were tested under ultimate tension and 3 specimens were investigated in fatigue test. Different parameters including PBR stiffening, brace-to-chord ratio (${\beta}$) and inclined angle (${\theta}$) were considered in the test. Each joint was tested to failure under tension load. Obtained from test result, PBR was found to improve the tension strength and fatigue durability of CRHS joint substantially. Concrete dowel consisted by PBR and concrete inside the chord stiffened the joint, which leaded to a combination failure mode of punching shear and chord plastification of CRHS joint under tension. Finite element analysis validated the compound failure mode. Stress concentration on typical spot of CRHS joint was mitigated by PBR which was observed from fatigue test. Initial fatigue crack presented in CRHS joint with PBR also differentiated with the counterpart without PBR.

Experimental shear strength evaluation of perfobond shear connector with various hole shapes

  • Zheng, Shuangjie;Zhao, Chen;Liu, Yuqing
    • Structural Engineering and Mechanics
    • /
    • 제67권2호
    • /
    • pp.131-142
    • /
    • 2018
  • The perfobond connector, composed of a steel plate with a number of holes, serves as a certain type of shear connector in steel and concrete composite structures. Depending on limits in hole distances and rib heights, various hole shapes including circular-hole and long-hole are alternatives for perfobond connectors. This study presented the results of tests performed on 72 push-out specimens with perfobond connectors. The purpose was to evaluate the shear strength of perfobond connectors with circular-hole and long-hole. The effects of various parameters were investigated, including the hole diameter, the hole length, the hole height, the concrete strength, the existence, diameter and strength of rebar in the hole, the thickness, height and distance of perfobond ribs, and the thickness of concrete slabs. On the basis of 132 push-out test results in references and in this study, an analytical model was proposed by regression analysis to predict the shear strength of perfobond connectors. The proposed equation agreed reasonably well with the experimental results of perfobond connectors with different hole shapes.

전단구속철근을 배치한 유공강판 전단연결재에 관한 실험적 연구 (An Experimental Study on the Behavior of the Perforated Rib Connector with Shearing Bars)

  • 김성칠;김영호;유성근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권6호
    • /
    • pp.175-182
    • /
    • 2006
  • 강 콘크리트 합성구조에서 강재와 콘크리트 사이의 경계면에 효과적인 응력전달과 합성거동을 유도하기 위하여 스터드, 채널, 유공강판 등이 사용된다. 가장 광범위하게 사용하는 전단연결재는 스터드 형식이고, 최근에 들어서는 강판에 구멍을 뚫은 유공강판전단연결재인 Perfobond가 주목을 받고 있다. 본 연구는 강 콘크리트 합성교량에 적용하기 위한 Perfobond형 전단연결재의 연성능력과 전단성능을 향상시킬 목적으로 횡방향 전단구속철근을 배치하고, Push-out 실험을 수행하여 전단내력을 비교하였다. 실험결과, 유공강판 전단연결재에 전단구속철근, 횡방향 관통철근, 단부 지압판 등을 설치함에 따른 수평 저항성능이나 다웰효과 등에 의해 전단내력이 상승하였으며, 또한 최대내력 이후 변형능력이 유지되면서 연성거동 특성을 보였다.

유공강판 전단연결재로 보강된 강관말뚝머리의 구조 성능 평가 (The Structural Performance Evaluation of Steel Pipe Pile Cap with Perfobond Rib Shear Connector)

  • 구현본;김영호;강재윤
    • 대한토목학회논문집
    • /
    • 제28권6A호
    • /
    • pp.843-851
    • /
    • 2008
  • 본 연구에서는 현행 설계기준상의 강관말뚝머리 연결부 결합방법이 갖고 있는 전단키 용접, 철근 배근 및 정착길이 확보 등의 문제점을 개선하고자 결합용 구조 요소로 유공강판 전단연결재(Perforated Flat Shear Connector)를 활용한 새로운 보강방법을 고안하고 이에 대한 구조적 거동 특성을 실험적으로 규명하였다. 실험 결과, 유공강판 전단연결재를 활용한 보강방법은 기존 방법을 대체할 만한 동등 수준 이상의 구조 안전성은 물론 시공성 및 경제성 측면에서도 우수한 성능을 갖는 구조 시스템인 것으로 나타났으며, 이에 따라 효율적인 강관말뚝머리 연결부 보강방법의 하나로 자리매김할 것으로 기대된다.

Shear resistance behaviors of a newly puzzle shape of crestbond rib shear connector: An experimental study

  • Chu, Thi Hai Vinh;Bui, Duc Vinh;Le, Van Phuoc Nhan;Kim, In-Tae;Ahn, Jin-Hee;Dao, Duy Kien
    • Steel and Composite Structures
    • /
    • 제21권5호
    • /
    • pp.1157-1182
    • /
    • 2016
  • A newly puzzle shape of crestbond rib shear connector is a type of ductile perfobond rib shear connector. This shear connector has some advantages, including relatively easy rebar installation and cutting, as well as the higher shear resistance strength. Thus, this study proposed a newly puzzle shape of crestbond rib with a "${\mho}$" shape, and its shear resistance behaviors and shear strengths were examined using push-out tests. Five main parameters were considered in the push-out specimens to evaluate the effects of shear resistance parameters such as the dimensions of the crestbond rib, transverse rebars in the crestbond dowel, concrete strength, rebar strength, and dowel action on the shear strength. The shear loading test results were used to compare the changes in the shear behaviors, failure modes, and shear strengths. It was found that the concrete strength and number of transverse rebars in the crestbond rib were significantly related to its shear resistance. After the initial bearing resistance behavior of the concrete dowel, a relative slip occurred in all the specimens. However, its rigid behavior to shear loading decreased the ductility of the shear connection. The cross-sectional area of the crestbond rib was also shown to have a minor effect on the shear resistance of the crestbond rib shear connector. The failure mechanism of the crestbond rib shear connector was complex, and included compression, shear, and tension. As a failure mode, a crack was initiated in the middle of the concrete slab in a vertical direction, and propagated with increasing shear load. Then, horizontal cracks occurred and propagated to the front and rear faces of the specimens. Based on the results of this study, a design shear strength equation was proposed and compared with previously suggested equations.

유공강판 전단연결재의 인발저항성능 평가 (Pull-out Resistance Capacity Evaluation of Perfobond Rib Shear Connector)

  • 김영호;구현본
    • 대한토목학회논문집
    • /
    • 제28권6A호
    • /
    • pp.853-859
    • /
    • 2008
  • 본 연구에서는 유공강판 전단연결재를 강관말뚝머리 연결부의 결합용 구조 요소로 활용하기 위한 연구의 일환으로 유공강판 전단연결재의 홀 형상, 홀 직경, 홀 관통철근, 매입깊이 등에 따른 구조적 성능 및 거동 특성을 실험적으로 규명하였으며, 그 결과 유공강판 전단연결재가 충분한 인발저항성능을 확보하기 위해서는 콘크리트 다웰 효과가 충분히 발현될 수 있도록 확보가능한 만큼의 다수의 홀을 가공 배치하되, 각 홀의 직경은 전단연결재 높이의 절반 정도임과 동시에 관통철근 배근 후에도 콘크리트의 완전한 충전이 가능할 만큼의 홀 내 여유 공간을 충분히 확보하는 것이 바람직하며, 아울러 유공강판 전단연결재가 강관말뚝머리 연결부의 결합용 구조 요소로서의 제기능을 발휘할 수 있도록 충분한 정착성능을 확보할 필요가 있다.

퍼포본드로 보강된 강관말뚝머리의 압발저항성능 평가 (The Push-out Resistance Evaluation of Steel Pipe Cap with Perfobond Rib Shear Connector)

  • 구현본;김영호;강재윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.77-80
    • /
    • 2008
  • 본 연구에서는 현행 설계기준상의 강관말뚝머리 연결부의 결합방법이 갖고 있는 철근 배근 및 정착길이 확보, 전단키 용접 등의 문제점을 개선하기 위해 퍼포본드 전단연결재(Perforated Rib Shear Connector)를 활용한 강관말뚝머리 보강방법을 고안하고 이에 대한 압발저항성능을 실험적으로 검증하였다. 그 결과 퍼포본드를 활용한 보강방법은 연직하중에 대해 기존 방법을 대체할만한 동등 수준이상의 구조 안전성은 물론 시공성 및 경제성 측면에서도 우수한 성능을 갖는 구조 시스템인 것으로 나타남에 따라 상부구조의 작용하중을 강관말뚝으로 전달하기 위한 효율적인 강관말뚝머리 연결부 보강방법의 하나로 자리매김할 것으로 사료된다.

  • PDF

유공판재형 전단연결재를 갖는 강-콘크리트 합성바닥판의 피로거동에 관한 연구 (Fatigue Behavior of Steel-Concrete Composite Bridge Deck with Perfobond Rib Shear Connector)

  • 경갑수;이승용;정연주;권순철
    • 대한토목학회논문집
    • /
    • 제30권1A호
    • /
    • pp.71-80
    • /
    • 2010
  • 교량 바닥판은 차량하중 및 환경 등의 영향을 직접 받는 부재여서 열화손상에 취약하므로 이에 대한 적절한 보수 및 보강이 필요하다. 그러므로 교량 바닥판의 유지관리를 최소화하고 교량의 설계수명까지의 공용을 위해서는 현재의 바닥판 성능을 개선한 고강도, 고내구성의 바닥판 개발이 필요하다. 따라서 본 연구에서는 기존의 철근콘크리트 바닥판의 문제점을 보완하여 새롭게 개발된 강-콘크리트 합성바닥판의 피로성능을 평가하기 위하여 정적실험을 실시하고, 이를 토대로 피로하중을 선정하고 일정진폭 반복하중 하에서 피로실험을 실시하였다. 이로부터 합성바닥판의 주요 구조상세의 S-N 곡선을 작성하고, 이를 피로설계기준과 비교, 평가하여 피로거동 특성을 규명하고 피로설계지침을 제시하였다. 그 결과 본 연구에서 제안된 합성바닥판의 각 구조상세인 절곡강판 상부플랜지 및 절곡강판 중간부, 전단연결재 및 절곡강판 하부플랜지는 모두 충분한 피로강도를 확보하고 있는 것을 알 수 있었다.

CT형강 전단연결재가 적용된 합성형 PHC벽체파일-하부슬래브 연결부 성능에 관한 실험적 연구 (An Experimental Study on Structural Capacity of Joint Between Composite PHC Wall Pile and Bottom Slab with CT Shear Connector)

  • 마호성;원정훈;이종구
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.531-541
    • /
    • 2013
  • 본 연구에서는 합성형 PHC 벽체파일의 CT형강 전단연결재가 벽체파일과 하부 슬래브와의 연결부에서 인장력에 저항하는 앵커의 성능을 갖는지 직접 인발실험을 통해 분석하였다. 다양한 실물 크기 실험체들의 파괴형상과 하중-변위 곡선으로부터 CT형강의 인발파괴를 방지하기 위해서는 CT형강 복부 홀에 관통철근을 배치하여 강도를 증가시켜야 함을 알 수 있다. 관통철근이 설치된 다양한 단면의 실험체들을 대상으로 지지점 거리를 변화시켜 파괴형상과 극한강도를 분석한 결과, CT형강의 인발파괴 전에 벽체파일 자체의 콘크리트 인장파괴가 모든 실험체에서 발생하므로 적용된 CT형강 전단연결재는 벽체파일과 하부 슬래브 연결부의 발생 인장력에 대해 충분히 저항할 수 있다.

전단 지간의 변화에 따른 PSC 거더용 강-콘크리트 합성 바닥판의 역학적 거동 (Behavior of Steel-Concrete Composite Decks for PSC Girder Bridge with Various Shear Span Lengths)

  • 김태협;박준명;홍성남;박선규;김형렬
    • 콘크리트학회논문집
    • /
    • 제19권3호
    • /
    • pp.275-281
    • /
    • 2007
  • 최근에 교량과 건축물의 건설에 강-콘크리트 합성 구조물이 광범위하게 적용되고 있다. 본 논문에서는 과거의 현장 타설 철근콘크리트 바닥판을 대체하기 위하여 새로운 형태의 강-콘크리트 합성 바닥판을 재안하였다. 유공판재형 전단 연결재는 성형 강판과 콘크리트 사이의 수평전단저항력을 제공하는데 유용하였다. 제안된 바닥판 시스템의 효과를 증명하기 위하여 PSC 거더용 바닥판을 8개 제작하였으며, 정적 하중 상태에서 바닥판의 수평전단저항력을 결정하기 위하여 4가지의 전단 지간을 적용하여 실험을 수행하였다. 또한 제안된 바닥판과의 비교를 위하여 2개의 철근콘크리트 바닥판을 제작하여 실험을 수행하였다. 그리고 제안된 바닥판 시스템의 수평전단저항력은 m-k 방법을 이용하여 산정되었다.