• Title/Summary/Keyword: peltier

Search Result 128, Processing Time 0.023 seconds

Composition and Evaluation of the Thermal Desorption-Gas Chromatographic System for the Measurement of Volatile Organic Compounds in Air (공기 중 휘발성 유기화합물의 측정을 위한 열탈착-분석시스템의 구성 및 평가)

  • 이수형;송희남;김희갑
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.63-71
    • /
    • 2002
  • The thermal desorption-gas chromatographic (TD-GC) system has been constructed for the measurement of volatile organic compounds. The thermal desortion unit is composed of four major parts: 1) the control part; 2) the thermal desorption part; 3) the focusing part; and 4) the injection part. The peltier element was introduced to the focusing part for the temperature of the focusing tube to reach-35$^{\circ}C$. The system was tested for the linearity of the calibration curves and reproducibility of instrumental analyses using some disinfection by-products (DBPs) and BTXs (benzene, toluene and p-xylene). The coefficients of determination (r$^2$) for all the calibration curves made were higher than 0.998, and the coefficients of variation (CV) for triplicate measurements were all within 10%. The system also has been tested for field applicability. The analysis of field samples showed that there was no breakthrough problem in the sampling system and that the system could be applied to field measurements.

Control of Junction Temperature in LEDs with Peltier Effect

  • Kim, Yun-Jung;Kim, Jeong-Hyeon;Han, Sang-Ho;Jeong, Jong-Yun;Kim, Hyeon-Cheol;Gang, Han-Rim;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.268-268
    • /
    • 2011
  • 열전소자를 사용하여 발광다이오드의 발열을 개선한다. 열전소자(Thermoelectric device: TED)의 펠티에효과(Peltier effect)를 이용하여 발광다이오드(Light Emitting Diodes: LED)의 접합온도 (Junction Temperature)를 제어한다. 열전소자의 구동 전력을 제어하여, 발광다이오드의 사용 전류에 대한 접합온도의 특성을 조사한다. 열전소자의 입력 전력 0.2W에 대하여, 일반 조명용 또는 표시 장치로 사용되는 1W급 고전력 LED를 정격전류(350 mA)로 구동할 때 접합온도를 최저 $69^{\circ}C$로 유지할 수 있다. 열전소자의 구동 전력이 0.2W일 때, 발광다이오드의 접합온도 $110^{\circ}C$에 대하여 최대 사용 가능 전류는 560 mA로 예측된다.

  • PDF

Experimental fabrication and analysis of thermoelectric devices (복합재료에 의한 열전변환 냉각소자의 개발에 관한 연구)

  • 성만영;송대식;배원일
    • Electrical & Electronic Materials
    • /
    • v.9 no.1
    • /
    • pp.67-75
    • /
    • 1996
  • This paper has presented the characteristics of thermoelectric devices and the plots of thermoelectric cooling and heating as a function of currents for different temperatures. The maximum cooling and heating(.DELTA.T) for (BiSb)$\_$2/Te$\_$3/ and Bi$\_$2/(TeSe)$\_$3/ as a function of currents is about 75.deg. C, A solderable ceramic insulated thermoelectric module. Each module contains 31 thermoelectric devices. Thermoelectric material is a quaternary alloy of bismuth, tellurium, selenium, and antimony with small amounts of suitable dopants, carefully processed to produce an oriented polycrystalline ingot with superior anisotropic thermoelectric properties. Metallized ceramic plates afford maximum electrical insulation and thermal conduction. Operating temperature range is from -156.deg. C to +104.deg. C. The amount of Peltier cooling is directly proportional to the current through the sample, and the temperature gradient at the thermoelectric materials junctions will depend on the system geometry.

  • PDF

Temperature Controllable HPLC Column for Preparative Fractionation of Polymers

  • Im, Kyu-Hyun;Park, Hae-Woong;Kim, Young-Tak;Chang, Tai-Hyun
    • Macromolecular Research
    • /
    • v.16 no.6
    • /
    • pp.544-548
    • /
    • 2008
  • An HPLC column with a self-contained temperature control device was constructed for preparative temperature programmed interaction chromatography. Two Peltier plates were attached to a large bore column ($120{\times}22\;mm$ i.d.) and the column temperature was controlled by PID mode feed back control. At a flow rate of 1.5 mL/min, the column temperature could be increased and decreased at a rate as high as $50^{\circ}C/min$ and $10^{\circ}C/min$, respectively, which is much faster than using a column jacket and bath/circulator. The rapid heating and cooling rates allows a high repetition rate of chromatographic fractionation. The performance of the temperature controllable column was demonstrated successfully by the fractionation of homo-polymer precursors from diblock copolymers.

A Study on flow optimization of thermoelectric refrigerator using visualization technique (가시화 기법을 이용한 열전소자 냉장고의 유동최적화에 관한 연구)

  • Kim, Bo-ra;Lee, Change-je;Jeong, Yeon-ho;Whang, Kwang-il;Cho, Gyeong-rae
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.1
    • /
    • pp.94-99
    • /
    • 2021
  • In order to increase the efficiency of thermoelectric refrigerators using the Peltier effect, it is necessary to optimize the distribution of the flow of cold air from the fan. In this study, the flow flowing upwards and downwards while changing the area of the flow path was visualized using the PIV technique for the control of cold air in a thermoelectric refrigerator. From these results, the flow rate according to the change in the area of the flow path was confirmed, and design criteria for optimizing the distribution of cold air flowing to the top and bottom of the refrigerator were suggested.

Implementation of Optimal Temperature Controller for Thermoelectric Device-based Heating System Using Genetic Algorithm (유전알고리즘을 이용한 열전소지 기반 히팅 시스템의 최적 온도 제어기 구현)

  • Jung-Shik Kong
    • Design & Manufacturing
    • /
    • v.17 no.3
    • /
    • pp.41-47
    • /
    • 2023
  • This paper presents the development of a controller that can control the temperature of an heating system based on a thermoelectric module. Temperature controller using Peltier has various external factors such as external temperature, characteristics of an aluminum plate, installation location of temperature sensors, and combination method between the aluminum plate and heating element. Therefore, it is difficult to apply the simulation and simulation results of heating system using Peltier at control algorithm. In general, almost temperature controller is using PID algorithm that finds control gain value heuristically. In this paper, it is proposed mathematical model that explain correlate between the temperature of the heating system and input voltage. And then, optimal parameter of estimated thermal model of the aluminum plate are searched by using genetic algorithm. In addition, based on this estimated model, the optimal PID control gain are inferred using a genetic algorithm. All of the sequence are simulated and verified with proposed real system.

Development of SMH Actuator System Using Hydrogen-Absorbing Alloy (수소저장합금을 이용한 SMH 액추에이터 시스템 개발)

  • Kwon, Tae-Kyu;Hong, Kyung-Ju;Kim, Kyung;Jeon, Won-Suk;Pang, Du-Yeol;Lee, Seong-Cheol;Kim, Nam-Gyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1067-1073
    • /
    • 2007
  • This paper presents development of an special metal hydride(SMH) actuator system using a peltier module. The newly developed simple SMH actuator, consisting of the plated hydrogen-absorbing alloy as a power source, Peltier elements as a heat source and a cylinder with metal bellows as a functioning part, has been developed. The SMH actuator is characterized by its small size, low weight, noiseless operation and a compliance similar to that of human body. A new SMH actuator that uses reversible reactions between the heat energy and mechanical energy of a hydrogen absorbing alloy. It is well known that hydrogen-absorbing alloys can reversibly absorb and desorb a large amount of hydrogen, more than about 1000 times of their own volume. To improve the thermal conductivity of the hydrogen-absorbing alloy, an electro-less copper plating has been carried out. For this purpose, the effects of the electro-less copper plating and the dynamic characteristics of the SMH actuator have been studied. The hydrogen equilibrium pressure increases and hydrogen is desorbed by heating the hydrogen-absorbing alloys, whereas by cooling the alloys, the hydrogen equilibrium pressure decreases and hydrogen is absorbed. The SMH actuator has the characteristic of being light and easy to use. Therefore, it is suitable for medical and rehabilitation applications.

Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature (손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정)

  • Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.