• Title/Summary/Keyword: peak-flow

Search Result 1,463, Processing Time 0.032 seconds

Tc-99m-DAPA Pulmonary Clearance in Normals (정상성인에서의 Tc-99m-DTPA 폐제거율)

  • Chung, Soo-Kyo;Yang, Woo-Jin;Sohn, Hyung-Sun;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.338-342
    • /
    • 1994
  • Pulmonary clearance of Tc-99m-DTPA(PCD) has been used for the measurement of polmonary epithelial permeability. It has been reported to be increased not only in variety of polmonary diseases including ARDS, interstitial fibrosis, and smokers, but also in normal subjects on positive end expiratory pressure respirator, or after exercise. It was also noted that decrease of pulmonary blood flow due to pulmonary arterial obstruction results in delayed PCD. Normal range of PCD varies with institutes. We prospectively measured PCD in 17 normals (5 males and 12 females) consisted of staffs and trainees in the department of radiology of Kangnam St. Mary's hospital using original Bark Nebulizer (India). Age ranged from 32 to 43 years. 370 MBq of Tc-99m-DTPA was inhaled in supine position and supine posterior images were subsequently obtained with 1 min/frame, $64{\times}64$ matrix and word mode for 30min. Regions of interest were set on each lung, whole lungs, and upper, middle and lower thirds of right lung, respectively. Best fit regression curve was obtained by least square method from initial 7min after peak activity on each curve and time for half clearance of maximum activity (t1/2) was calculated. Mean t1/2 was $51{\pm}11.2min$ for whole lung. There was no significant difference between t1/ 2 of right and left lungs. Initial uptake was higher in the lower third and t1/2 was shorter in the lower third than in the upper third(P<0.05). We reviewed several reports on PCD and compared our data with the others. In this study, faster clearance in the lower third may be due to the position imaged with or the environment the subjects belong to, and further investigation is under way.

  • PDF

Estimating design floods for ungauged basins in the geum-river basin through regional flood frequency analysis using L-moments method (L-모멘트법을 이용한 지역홍수빈도분석을 통한 금강유역 미계측 유역의 설계홍수량 산정)

  • Lee, Jin-Young;Park, Dong-Hyeok;Shin, Ji-Yae;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.8
    • /
    • pp.645-656
    • /
    • 2016
  • The study performed a regional flood frequency analysis and proposed a regression equation to estimate design floods corresponding to return periods for ungauged basins in Geum-river basin. Five preliminary tests were employed to investigate hydrological independence and homogeneity of streamflow data, i.e. the lag-one autocorrelation test, time homogeneity test, Grubbs-Beck outlier test, discordancy measure test ($D_i$), and regional homogeneity measure (H). The test results showed that streamflow data were time-independent, discordant and homogeneous within the basin. Using five probability distributions (generalized extreme value (GEV), three-parameter log-normal (LN-III), Pearson type 3 (P-III), generalized logistic (GLO), generalized Pareto (GPA)), comparative regional flood frequency analyses were carried out for the region. Based on the L-moment ratio diagram, average weighted distance (AWD) and goodness-of-fit statistics ($Z^{DIST}$), the GLO distribution was selected as the best fit model for Geum-river basin. Using the GLO, a regression equation was developed for estimating regional design floods, and validated by comparing the estimated and observed streamflows at the Ganggyeong station.

Effect of Trunk Strength Exercise and Deep Stabilization Exercise Combined with Breathing Exercise on Abdominal Muscle Thickness and Respiration (호흡운동을 병행한 몸통 근력운동과 심부 안정화 운동이 배근육 두께와 호흡에 미치는 영향)

  • Kim, Hyeonsu;Lee, Keoncheol;Choo, Yeonki
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.181-188
    • /
    • 2020
  • Purpose : The purpose of this study is to compare the effects on abdominal muscle thickness and breathing by applying trunk strength exercise and deep stabilization exercise along with breathing exercise, which is the main respiratory muscle during breathing, to present an efficient exercise method with diaphragm breathing. Methods : This study was performed on normal 6 females and 14 males subjects. They were divided into 2 groups which trunk strength exercise and deep stabilization exercise group. The trunk strength exercise group (TSE) attended prone press-up, crunch and pelvic tiling. The deep stabilization exercise group (DSE) attended abdominal drawing, horizontal side-support and bridging exercise. Breathing exercise was performed for each set break time for 1 minute. Results : First, in the comparison of the change in the thickness of the abdominal muscle between the trunk strength training group and the deep stabilization group before and after exercise, there was a statistically significant difference in the comparison of transverse abdominis (TrA), rectus femoris (RF), external oblique (EO), internal oblique (IO) (p<.05). However, there was no significant difference in any comparison between groups (p>.05). Second, in the comparison of changes in respiratory function between the trunk strength exercise group and the deep stabilization exercise group before and after exercise, there were statistically significant differences in the exerted forced vital capacity (FVC), forced expiratory volume at one second (FEV1), peak expiratory flow (PEF) in the comparison before and after the experiment (p<.05). However, there was no significant difference in any comparison between groups (p>.05). Conclusion : As a result of this study, it can be said that both trunk strength exercises and deep stabilization exercises along with diaphragm breathing are exercises that strengthen deep and superficial muscles, and have a positive effect on breathing function as well as muscle strength. However, it is not known which exercise was more effective, and because it was combined with breathing exercise, the interference effect appeared.

Growth Characteristics of Blue-green Algae (Anabaena spiroides) Causing Tastes and Odors in the North-Han River, Korea (북한강 수계에서 이취미를 유발하는 남조류(Anabaena spiroides)의 증식 특성)

  • You, Kyung-A;Byeon, Myeong-Seop;Youn, Seok-Jea;Hwang, Soon-Jin;Rhew, Doug-Hee
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.135-144
    • /
    • 2013
  • Blue-green algae blooms occurred during early winter in the North-Han River, Korea. Among blue-green algae, Anabaena spiroides were observed for approximately 33 consecutive days, between 28 November and 30 December, 2011. A. spiroides emerged from Lake Uiam to Lake Paldang, depending on the flow of the river has spread downstream. Changes of physical water environment like rising water temperature and increasing hydraulic retention time influenced the A. spiroides bloom. The A. spiroides bloom showed a very rapid increase in cell density, and a slow decrease: the cell density increased to a maximum of $11,325cells\;mL^{-1}$ in Lake Paldang (st. 5), and was completely disappeared after the water temperature dropped below $4^{\circ}C$. A decrease in water temperature was the most influential factor among all environmental parameters, for the reduction of A. spiroides cell density. The A. spiroides bloom was accompanied with the occurrence of very high concentrations of the odor metabolite geosmin. Geosmin reached the peak value of $1,640ng\;L^{-1}$ in Lake Paldang (st. 4). The geosmin concentration was very strongly correlated with cell numbers of A. spiroides.

Optimal HPLC Condition for Simultaneous Determination of Catechins and Caffeine in Green Tea Extracts (녹차 함유 카테친 및 카페인 동시분석을 위한 최적 HPLC 분석 조건)

  • Choung, Myoung-Gun;Lee, Min-Seuk
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.2
    • /
    • pp.224-232
    • /
    • 2008
  • The health benefits associated with tea consumption have resulted in the wide inclusion of green tea extracts in botanical dietary supplements, which are widely consumed as adjuvants for complementary and alternative medicines. Tea contains polyphenols such as catechins or flavan-3-ols including (-)-epicatechin (EC), (-)-epigallocatechin (EGC), (-)-epicatechin gallate (ECG), and (-)-epigallocatechin gallate (EGCG), as well as the alkaloid, caffeine. The contents of catechins and caffeine in green tea are considered as a standard of quality evaluation of green tea. Therefor, the purpose of this study was to investigate the most suitable HPLC condition for simultaneous determination of catechins and caffeine in green tea extracts. The efficient HPLC analytical condition of catechins and caffeine contained green tea extracts was developed. The gradient elution employed a $250\;mm\;{\times}\;4.6\;mm$ i.d. YMC-pak ODS-AM 303 column. The gradient system was used two mobile phases. A gradient elution was performed with mobile phase A, consisting of 0.1% aqueous phosphoric acid, and mobile phase B, comprising 100% MeOH, and delivered at a flow rate of 1 mL/min as follows: $0{\sim}25\;min$, 80% A; $26{\sim}50\;min$, $80{\sim}70%$ A; 51 min, 80% A. $51{\sim}55\;min$, 80% A. The UV detection wavelength was set at 280 nm. The limit of detection (LOD) for catechins and caffeine standards were under 50 ng/mL.

Shear-Rate Dependent Ring-Shear Characteristics of the Waste Materials of the Imgi Mine in Busan (부산 임기광산 광미의 전단속도에 따른 링 전단특성 연구)

  • Jeong, Sueng-Won;Ji, Sang-Woo;Yim, Gil-Jae
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.7
    • /
    • pp.5-15
    • /
    • 2014
  • Abandoned mine deposits are exposed to various physico-chemical geo-environmental hazards and disasters, such as acid mine drainage, water contamination, erosion, and landslides. This paper presents the ring shear characteristics of waste materials. The ring shear box with a rotatable O-ring was used in this study. Three tests were performed: (i) Shear stress-time relationship for given normal stress and shear speed, (ii) shear stress as a function of shear speed, and (iii) shear stress as a function of normal stress. For a given normal stress (50 kPa) and speed (0.1 mm/sec), the materials tested exhibit a strain softening behavior, regardless of drainage condition. The peak and residual shear stresses were determined for each normal stress and shear speed. The shear stress was measured when shear speed is equal to 0.01, 0.1, 1, 10, 50, 100 mm/sec or when normal stress is equal to 20, 40, 60, 80, 100, 150 kPa. From the test results, we found that the shear stress increases with increasing shear speed. The shear stress also increases with increasing normal stress. However, different types of shearing mode were observed in drained and undrained conditions. Under drained condition, particle crushing was observed from the shearing zone to the bottom of lower ring. Under undrained condition, particle crushing was observed only at the shearing zone, which has approximately 1 cm thick. It means that a significant high shear speed under undrained condition can result in increased landslide hazard.

Disinfection of E.coli in Drinking Water by TiO2 Photocatalytic System (TiO2 광촉매 시스템을 이용한 음용수 중의 대장균 살균연구)

  • Jung, Jin-Ah;Kwak, Do Hwan;Oh, Dae Woong;Park, Dong Min;Yang, O-Bong
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.11-17
    • /
    • 2012
  • Disinfection of Escherichia coli (E. coli) in drinking water was investigated by using $TiO_2$ and $TiO_2-SiO_2$ based photocatalyst prepared by sol-gel method. The disinfection test was carried out in an annular flow reactor with circulating sterile water containing the photocatalysts powder under UV-A irradiation. The disinfection activity was proportional to the anatase`s intensity of crystalline peak of the $TiO_2$ photocatalysts. 100% disinfection of E.coli without endotoxin was achieved with $TiO_2$ coated photocatalytic system under UV-A irradiation within 2 h. However, toxic endotoxine was exist in the disinfection of E.colithe under UV-C irradiation even though 100% disinfection of E.colithe within 30 min, which suggest that $TiO_2$ coated photocatalytic system with UV-A is useful tool for the disinfection of E.coli in drinking water.

Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film

  • Bogdanowicz, Robert;Sobaszek, Michał;Ficek, Mateusz;Gnyba, Marcin;Ryl, Jacek;Siuzdak, Katarzyna;Bock, Wojtek J.;Smietana, Mateusz
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.705-710
    • /
    • 2015
  • The fabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrodes on fused silica single mode optical fiber cladding has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ℃. We have obtained homogenous, continuous and polycrystalline surface morphology with high sp3 content in B-NCD films and mean grain size in the range of 100-250 nm. The films deposited on the glass reference samples exhibit high refractive index (n=2.05 at λ=550 nm) and low extinction coefficient. Furthermore, cyclic voltammograms (CV) were recorded to determine the electrochemical window and reaction reversibility at the B-NCD fiber-based electrode. CV measurements in aqueous media consisting of 5 mM K3[Fe(CN)6] in 0.5 M Na2SO4 demonstrated a width of the electrochemical window up to 1.03 V and relatively fast kinetics expressed by a redox peak splitting below 500 mV. Moreover, thanks to high-n B-NCD overlay, the coated fibers can be also used for enhancing the sensitivity of long-period gratings (LPGs) induced in the fiber. The LPG is capable of measuring variations in refractive index of the surrounding liquid by tracing the shift in resonance appearing in the transmitted spectrum. Possible combined CV and LPG-based measurements are discussed in this work.

Dry Etching of PMMA and Polycarbonate in a Diffusion Pump-based Capacitively Coupled O2 Plasma (확산펌프 기반의 O2 축전결합 플라즈마를 이용한 PMMA와 폴리카보네이트의 건식 식각)

  • Park, Ju-Hong;Lee, Seong-Hyun;Choi, Jyoung-Hoon;Noh, Ho-Sub;Lee, Je-Won
    • Korean Journal of Materials Research
    • /
    • v.19 no.8
    • /
    • pp.421-426
    • /
    • 2009
  • We report on the capacitively coupled O2 plasma etching of PMMA and polycarbonate (PC) with a diffusion pump. Plasma process variables were process pressure and CCP power at 5 sccm $O_2$ gas flow rate. Characterization was done in order to analyze etch rate, etch selectivity, surface roughness, and morphology using stylus surface profilometry and scanning electron microscopy. Self bias decreased with increase of process pressure in the range of 25$\sim$180 mTorr. We found an important result for optimum pressure for the highest etch rate of PMMA and PC, which was 60 mTorr. PMMA and PC had etch rates of 0.46 and 0.28 ${\mu}m$/min under pressure conditions, respectively. More specifically, etch rates of the materials increased when the pressure changed from 25 mTorr to 60 mTorr. However, they reduced when the pressure increased further after 60 mTorr. RMS roughnesses of the etched surfaces were in the range of 2.2$\sim$2.9 nm. Etch selectivity of PMMA to a photoresist was $\sim$1.5:1 and that of PC was $\sim$0.9:1. Etch rate constant was about 0.04 ${\mu}m$/minW and 0.02 ${\mu}m$/minW for PMMA and PC, respectively, with the CCP power change at 5 sccm $O_2$ and 40 mTorr process pressure. PC had more erosion on the etched sidewall than PMMA did. The OES data showed that the intensity of the oxygen atomic peak (777.196 nm) proportionally increased with the CCP power.

Assessment of Dual-Polarization Radar for Flood Forecasting (이중편파 레이더의 홍수예보 활용성 평가)

  • Kim, Jeong-Bae;Choi, Woo-Seok;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.4
    • /
    • pp.257-268
    • /
    • 2015
  • The objective of this study is to assess the dual-polarization radar for flood forecasting. First, radar rainfall has temporal and spatial errors, so estimated radar rainfall was compared with ground observation rainfall to assess accuracy improvement, especially, considering the radar range of observation and increase of the rainfall intensity. The results of this study showed that the error for estimated dual-polarization radar rainfall was less than single-polarization radar rainfall. And in this study, dual-polarization radar rainfall for flood forecasting was assessed using MAP (Mean Areal Precipitation) and SURR (Sejong University Rainfall Runoff) model in Namkang dam watershed. The results of MAP are more accurate using dual-polarization radar. And the results of runoff using dual-polarization radar rainfall showed that peak flow error was reduced approximately 12~63%, runoff volumes error was reduced by approximately 30~42%, and also the root mean square error decreased compared to the result of runoff using single-polarization radar rainfall. The results revealed that dual-polarization radar will contribute to improving the accuracy of the flood forecasting.