• Title/Summary/Keyword: peak value

Search Result 2,398, Processing Time 0.034 seconds

The Isokinetic Strength Evaluation of Trunk Flexors and Extensors by Contranction Type (체간 굴곡근과 신전근의 수축 형태에 따른 등속성 근력평가)

  • Kim Yang-Hee;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.2
    • /
    • pp.57-69
    • /
    • 1998
  • The role of eccentric muscle activities in functional everyday activities and sport is important and equally significant to concentric conditions. Eccentric and concentric exercise and evaluation are, therefore, very important. The purposes of this study were to measure eccentric md concentric peak torgue, percentage of peak torque, average power and percentage of average power of trunk flexors and extensors by using the Cybex NORM isokinetic dynamometer, and to standardize the value obtained. Thirty four young volunteers were tested, 17 females and 17 males, who had no history of back pain or abnormality. Each subjects were tested on three repetitions for isokinetic concentric and eccentric contraction at 5 velocities. The results were as follows; 1) Peak torque percent body weight of eccentric contraction were significantly greater than concentric contraction at each angular velocity and in trunk flexors and extensors(p<0.01). 2) Peak torque percent body weight of concentric contraction were significantly decreased as the angular velocity increased both male and female(p<0.01). 3) Peak torque percent body weight of eccentric contraction were not significantly changed as the angular velocity increased both male and female(p<0.05), 4) Peak torque percent body weight of male were significantly greater than female at each angular velocity and in concentric and eccentric contraction of trunk flexors and extensors(p<0.01)

  • PDF

Improvement of extinction ratio of amplified pulses by incorporating a nonlinear optical loop mirror (EDFA로 증폭된 고출력 펄스 신호의 소광비 향상)

  • Kim, Byung-Jun;Choi, Hyun-Beom;Lee, Han-Hyub;Lee, Dong-Han;Kim, Dae-Yun;Kwon, Il-Bum
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.2
    • /
    • pp.189-193
    • /
    • 2003
  • A two-stage erbium-doped fiber amplifier (EDFA) with a band pass filter is used to get optical pulses of high peak value. The pulse signal has a 32 ㏈ extinction ratio, 125 W peak power and 79 ㎽ pulse off power. A nonlinear optical loop mirror (NOLM) is used to lower the pulse off power so as to increase the extinction ratio. The pulse signal after the NOLM has a 50.4 ㏈ extinction ratio, 35 W peak power and 0.3 ㎽ pulse off power.

Similar Movie Retrieval using Low Peak Feature and Image Color (Low Peak Feature와 영상 Color를 이용한 유사 동영상 검색)

  • Chung, Myoung-Beom;Ko, Il-Ju
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.8
    • /
    • pp.51-58
    • /
    • 2009
  • In this paper. we propose search algorithm using Low Peak Feature of audio and image color value by which similar movies can be identified. Combing through entire video files for the purpose of recognizing and retrieving matching movies requires much time and memory space. Moreover, these methods still share a critical problem of erroneously recognizing as being different matching videos that have been altered only in resolution or converted merely with a different codec. Thus we present here a similar-video-retrieval method that relies on analysis of audio patterns, whose peak features are not greatly affected by changes in the resolution or codec used and image color values. which are used for similarity comparison. The method showed a 97.7% search success rate, given a set of 2,000 video files whose audio-bit-rate had been altered or were purposefully written in a different codec.

Growth and Anthocyanins of Lettuce Grown under Red or Blue Light-emitting Diodes with Distinct Peak Wavelength (상이한 피크파장의 적색광 및 청색광 발광다이오드 조사에 따른 상추의 생장 및 안토시아닌)

  • Lee, Jae Su;Kim, Yong Hyeon
    • Horticultural Science & Technology
    • /
    • v.32 no.3
    • /
    • pp.330-339
    • /
    • 2014
  • Growth and anthocyanins of lettuce (Lactuca sativa L., 'Mid-season') grown under LED lamps with blue light in the range of 430-470 nm or with red light in the range of 630-670 nm were analyzed in this study. Cool-white fluorescent light was used a s the control. P hotosynthetic photon flux, p hotoperiod, air temperature, relative humidity, and $CO_2$ concentration in a closed plant production system were $201{\pm}2\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 16/8 hours (day/night), $22/18^{\circ}C$, 70%, and $400{\mu}mol{\cdot}mol^{-1}$, respectively. At 21 days after light quality treatment, growth characteristics and anthocyanins content of lettuce as affected by the peak wavelength of blue or red LED were significantly different. Among peak wavelengths treated in this stusy, R1 treatment (peak wavelength 634 nm) and R6 treatment (peak wavelength 659 nm) were effective for increasing leaf width, leaf area, shoot fresh weight, and photosynthetic rate of lettuce. B5 treatment (peak wavelength 450 nm) and B4 treatment (peak wavelength 446 nm) increased the anthocyanins concentration and chlorophyll content in lettuce leaves, respectively. Anthocyanins in lettuce leaves increased linearly with decreasing hue value of leaf color and with increasing SPAD value of lettuce leaves. From these results, it was concluded that the red LED with peak wavelengths of 634 nm and 659 nm and the blue LED with peak wavelengths of 450 nm can be used as potential light spectra for increasing the yield and anthocyanins accumulation of leafy vegetable.

Purification and Isolation for Antihypertensive Peptides from Beef Heart and Spleen (쇠고기 부산물로부터 혈압 상승 억제 펩타이드 분리 및 정제)

  • Jang, S. H.;Jang, A.;Kim, K. J.;Cheon, Y. H.;Min, J. S.;Lee, S. O.;Lee, M.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.319-326
    • /
    • 2003
  • Angiotensin-I converting enzyme(ACE)inhibitor was isolated from beef by-products. The beef by- product hydrolysates prepared with various proteases were tested for the inhibitory effects against ACE. The proteases used were proteinase A from bakers yeast, protease type ⅩIII fungal and thermolysin. The maximum inhibitory effect was observed after hydrolysis for 12hrs(beef heart) and 24hrs(beef spleen), respectively. After gel filtration, IC50 value was 0.37mg/ml in beef heart and 1.84mg/ml in beef spleen. After RP-HPLC, the IC50 value of peak 1, peak 2, peak 3 and peak-4 were 0.28mg/ml, 0.26mg/ml, 0.25mg/ml and 0.35mg/ml, respectively. In the results of amino acid composition of peak 1, peak 2, peak 3 and peak 4, it was observed that peak 1 was consisted mainly of glycine and methionine, peak 2 was proline, cystine and methionine, peak 3 was proline and peak 4 was alanine, methionine and leucine. In conclusion, beef heart hydrolysate treated with thermolysin+ proteinase A was shown to have the highest inhibitory effect for 12hrs incubation at 37$^{\circ}C$.

Design of Driving methods of lower power consumption in Plasma AI(plasma adaptive intensifier) driving method (Plasma AI(plasma adaptive intensifier)구동의 전력 소모 개선을 위한 구동방식 설계)

  • Kim, Jun-Hyeong;O, Sun-Taek;Lee, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.844-847
    • /
    • 2003
  • Display devices are becoming increasingly important as an interface between humans and machines in the growing information society. In display devices, PDP (Plasma Display Panel) has many advantages in that it has wide screen, wide viewing angle and is light weight, thin. In PDP driving method, if the brightness of input image is high, applying the fixed sustain pulse to the PDP panel will raise the PDP power consumption and may damages the PDP panel. To overcome these problems, the Plasma AI driving method was introduced by the Matshushita co. in Japan. The Plasma AI driving module calculates the peak value and average value of 1 frame image and adjusts the gradation and sustain pulses for 1 frame sustain. In this paper, the proposed PDP driving module is based on the Plasma AI driving module. The proposed driving module calculates peak value and average value, and the brightness distribution of 1 frame image. Using brightness distribution, the proposed driving module divides 1 frame input image into 15 image patterns. For each image pattern, minimum sustain pulses and sub-frames are used for the brightness of 1 frame image and the sustain weight for 64, 128, 192 gradation is proposed. Therefore, the sustain power consumption can be reduced.

  • PDF

Program Cache Busy Time Control Method for Reducing Peak Current Consumption of NAND Flash Memory in SSD Applications

  • Park, Se-Chun;Kim, You-Sung;Cho, Ho-Youb;Choi, Sung-Dae;Yoon, Mi-Sun;Kim, Tae-Yun;Park, Kun-Woo;Park, Jongsun;Kim, Soo-Won
    • ETRI Journal
    • /
    • v.36 no.5
    • /
    • pp.876-879
    • /
    • 2014
  • In current NAND flash design, one of the most challenging issues is reducing peak current consumption (peak ICC), as it leads to peak power drop, which can cause malfunctions in NAND flash memory. This paper presents an efficient approach for reducing the peak ICC of the cache program in NAND flash memory - namely, a program Cache Busy Time (tPCBSY) control method. The proposed tPCBSY control method is based on the interesting observation that the array program current (ICC2) is mainly decided by the bit-line bias condition. In the proposed approach, when peak ICC2 becomes larger than a threshold value, which is determined by a cache loop number, cache data cannot be loaded to the cache buffer (CB). On the other hand, when peak ICC2 is smaller than the threshold level, cache data can be loaded to the CB. As a result, the peak ICC of the cache program is reduced by 32% at the least significant bit page and by 15% at the most significant bit page. In addition, the program throughput reaches 20 MB/s in multiplane cache program operation, without restrictions caused by a drop in peak power due to cache program operations in a solid-state drive.

R-Peak Detection Algorithm in ECG Signal Based on Multi-Scaled Primitive Signal (다중 원시신호 기반 심전도 신호의 R-Peak 검출 알고리즘)

  • Cha, Won-Jun;Ryu, Gang-Soo;Lee, Jong-Hak;Cho, Woong-Ho;Jung, YouSoo;Park, Kil-Houm
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.5
    • /
    • pp.818-825
    • /
    • 2016
  • The existing R-peak detection research suggests improving the distortion of the signal such as baseline variations in ECG signals by using preprocessing techniques such as a bandpass filtering. However, preprocessing can introduce another distortion, as it can generate a false detection in the R-wave detection. In this paper, we propose an R-peak detection algorithm in ECG signal, based on primitive signal in order to detect reliably an R-peak in baseline variation. First, the proposed algorithm decides the primitive signal to represent the QRS complex in ECG signal, and by scaling the time axis and voltage axis, extracts multiple primitive signals. Second, the algorithm detects the candidates of the R-peak using the value of the voltage. Third, the algorithm measures the similarity between multiple primitive signals and the R-peak candidates. Finally, the algorithm detects the R-peak using the mean and the standard deviation of similarity. Throughout the experiment, we confirmed that the algorithm detected reliably a QRS group similar to multiple primitive signals. Specifically, the algorithm can achieve an R-peak detection rate greater than an average rate of 99.9%, based on eight records of MIT-BIH ADB used in this experiment.

Influence on Meridians Electric Potential for Electrical Ground and Insulation (-침술효과 객관화를 위한 연구- 접지와 절연조건이 경락전위에 미치는 영향)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2243-2250
    • /
    • 2006
  • When a patient is positioned at insulated bed and practitioner is positioned at insulated floor, that condition could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection and Insulation could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated non-insulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground respectively. Then we used insulated needles and measured same as above. Non-insulated all ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. Practitioner ground only showed negative mean potential of $51.5{\pm}9.3{\mu}V$ and $367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential of $2.9{\pm}1.3{\mu}V$, $16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential of $1.6{\pm}0.7{\mu}V$, $3.3{\pm}1.9{\mu}V$ of peak to peak potential. In case of Insulated condition, there elicited no mean potential. Non ground and Practitioner only showed weak value of peak to peak potential as $7.8{\pm}2.6{\mu}V$ and $8.4{\pm}2.5{\mu}V$ each. But patient only and all ground showed no potential as $4.7{\pm}2.2{\mu}V$, $3.4{\pm}2.2{\mu}V$, respectively. Therefore, Ground connection modulate the energy transfer course between practitioner and patient. Insulation block energy transfer but static electrical impulse between practitioner and patient.

Study on threshold values of a intensity-of-congestion measure for operations evaluation at signalized intersections based on traffic flow information (교통소통 정보기반 신호교차로 운영평가를 위한 혼잡강도 지표 임계값 연구)

  • Kim, Jin-Tae;Cho, Yongbin
    • International Journal of Highway Engineering
    • /
    • v.20 no.3
    • /
    • pp.85-92
    • /
    • 2018
  • PURPOSES : In this study, analyze the characteristics of IOC indicator 'threshold' which is needed when evaluating the traffic signal operation status with ESPRESSO in various grade road traffic environment of Seoul metropolitan city and derive suggested value to use in field practice. METHODS : Using the computerized database program (Postgresql), we extracted data with regional characteristics (Arterial, Collector road) and temporal characteristics (peak hour, non-peak hour). Analysis of variance and Duncan's validation were performed using statistical analysis program (SPSS) to confirm whether the extracted data contains statistical significance. RESULTS : The analysis period of the main and secondary arterial roads was confirmed to be suitable from 14 days to 60 days. For the arterial, it is suggested to use 20 km/h as the critical speed for PM peak hour and weekly non peak hour. It is suggested to use 25 km/h as the critical speed for AM peak hour and night non peak hour. As for the collector road, it is suggested to use 20 km/h as the critical speed for PM peak hour and weekly non peak hour. It is suggested to use 30 km/h as the critical speed for AM peak hour and night non peak hour. CONCLUSIONS : It is meaningful from a methodological point of view that it is possible to make a reasonable comparative analysis on the signal intersection pre-post analysis when the signal operation DB is renewed by breaking the existing traffic signal operation evaluation method.