• 제목/요약/키워드: peak to peak

검색결과 16,559건 처리시간 0.048초

체간 굴곡근과 신전근의 수축 형태에 따른 등속성 근력평가 (The Isokinetic Strength Evaluation of Trunk Flexors and Extensors by Contranction Type)

  • 김양희;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제10권2호
    • /
    • pp.57-69
    • /
    • 1998
  • The role of eccentric muscle activities in functional everyday activities and sport is important and equally significant to concentric conditions. Eccentric and concentric exercise and evaluation are, therefore, very important. The purposes of this study were to measure eccentric md concentric peak torgue, percentage of peak torque, average power and percentage of average power of trunk flexors and extensors by using the Cybex NORM isokinetic dynamometer, and to standardize the value obtained. Thirty four young volunteers were tested, 17 females and 17 males, who had no history of back pain or abnormality. Each subjects were tested on three repetitions for isokinetic concentric and eccentric contraction at 5 velocities. The results were as follows; 1) Peak torque percent body weight of eccentric contraction were significantly greater than concentric contraction at each angular velocity and in trunk flexors and extensors(p<0.01). 2) Peak torque percent body weight of concentric contraction were significantly decreased as the angular velocity increased both male and female(p<0.01). 3) Peak torque percent body weight of eccentric contraction were not significantly changed as the angular velocity increased both male and female(p<0.05), 4) Peak torque percent body weight of male were significantly greater than female at each angular velocity and in concentric and eccentric contraction of trunk flexors and extensors(p<0.01)

  • PDF

열적 피로에 의한 전원코드의 발화 특성과 전기화재 분석에 관한 연구 (A Study on the Electrical-Fire Analysis and Firing Characteristics of Power Cord by Thermal Stress)

  • 최충석;송길목;김향곤;김동욱;김동우
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2003년도 춘계학술논문발표회논문집
    • /
    • pp.164-170
    • /
    • 2003
  • In this paper, we studied on the firing characteristics and electrical fire analysis of power cord deteriorated by thermal stress. The cross section of PVC insulating cord deteriorated by indirect flame decreased through heat convection. PVC insulating cord deteriorated by direct flame was bumpy shape. The exothermic peak of normal cord was shown at ($526.7^{\circ}C$), but the peaks or on(heat treatment temperature) ($150^{\circ}C$) cord was shown at ($299.6^{\circ}C$) and [$502.2^{\circ}C$]. The exothermic peaks according to high temperature were similar to those of amorphous carbon. In the FT-IR analysis, the absorption peak of normal cord indicated double bond of oxygen and carbon in benzene ring at 1720.0$cm^{1}$. As the HTT was high, the height of characteristic peak decreased and the peak of carbonyl group was shown at about 1625.7$cm^{-1}$. The characteristic peak of single bond(O-H) was shown at about 3479.2$cm^{-1}$. In case of the internal part of wire covering deteriorated by over current, the characteristic peak were shown at about 3417.3$cm^{-1}$ and 1600.2$cm^{-1}$. The above results show that we can distinguish the differences according to the fire pattern through the internalㆍexternal analysis of wire covering deteriorated by heat.

  • PDF

Electrochemical Investigation of Acetaminophen with a Carbon Nano-tube Composite Film Electrode

  • Li, Chunya;Zhan, Guoqing;Yang, Qingdan;Lu, Jianjie
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1854-1860
    • /
    • 2006
  • Electrochemical behaviors of acetaminophen at a muti-wall carbon nano-tube composite film modified glassy carbon electrode were investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Compared with that obtained at the unmodified electrode, the peak currents were enhanced significantly, and the oxidation peak shifted towards more negative potential with the reduction peak shifted positively. The peak-to-peak separation turned narrow, and suggested that the reversibility was improved greatly. Experimental parameters, such as scan rate, pH and accumulation conditions were optimized. It was found that a maximum current response can be obtained at pH = 5.0 after accumulation at -0.50 V for 80 s. The oxidation peak current was found to be linearly related to acetaminophen concentration over the range of $5.0{\times}10^{-7}\;\sim\;1.0{\times}10^{-4}$ mol $L^{-1}$ with a detection limit of $5.0{\times}10^{-8} $mol $L^{-1}$. A convenient and sensitive electrochemical method was developed for the determination of acetaminophen in a commercial paracetamol oral solution. Its practical application demonstrated that it has good selectivity and high sensitivity.

EDFA로 증폭된 고출력 펄스 신호의 소광비 향상 (Improvement of extinction ratio of amplified pulses by incorporating a nonlinear optical loop mirror)

  • 김병준;최현범;이한협;이동한;김대연;권일범
    • 한국광학회지
    • /
    • 제14권2호
    • /
    • pp.189-193
    • /
    • 2003
  • 높은 peak 값의 광 펄스 신호를 얻기 위하여 대역통과 필터(band pass filter)를 사용한 2단 구조 erbium-doped fiber amplifier (EDFA)를 구성하여 125 W peak 값과 32 ㏈ 소광비(extinction ratio)를 갖는 펄스 신호를 얻었다. 이때 pulse off power는 79 ㎽이다. pulse off power를 낮추고 소광비를 높이기 위하여 nonlinear optical loop mirror(NOLM)을 사용하였다. NOLM 을 통과한 펄스 신호는 35 W peak 값과 0.3 ㎽ pulse off power, 50.4 ㏈ 소광비를 갖는다.

The topographic effect of ground motion based on Spectral Element Method

  • Liu, Xinrong;Jin, Meihai;Li, Dongliang;Hu, Yuanxin;Song, Jianxue
    • Geomechanics and Engineering
    • /
    • 제13권3호
    • /
    • pp.411-429
    • /
    • 2017
  • A Spectral Element Method for 3D seismic wave propagation simulation is derived based on the three-dimensional fluctuating elastic dynamic equation. Considering the 3D real terrain and the attenuation characteristics of the medium, the topographic effect of Wenchuan earthquake is simulated by using the Spectral Element Method (SEM) algorithm and the ASTER DEM model. Results show that the high PGA (peak ground acceleration) region was distributed along the peak and the slope side away from the epicenter in the epicenter area. The overall distribution direction of high PGA and high PGV (peak ground velocity) region is parallel to the direction of the seismogenic fault. In the epicenter of the earthquake, the ground motion is to some extent amplified under the influence of the terrain. The amplification effect of the terrain on PGA is complicated. It does not exactly lead to amplification of PGA at the ridge and the summit or attenuation of PGA in the valley.

뇌경새(腦梗塞) 환자(患者)와 건강인(健康人)의 맥상(脈象)과 사상체질(四象體質)에 관(關)한 연구(硏究) (Comparative Study on the Pulse Wave Variables and Sasang Constitution in Cerebral Infarction Patients and Healthy Subjects)

  • 고기덕;김경요;김종열;이시우;주종천
    • 대한약침학회지
    • /
    • 제10권2호통권23호
    • /
    • pp.119-132
    • /
    • 2007
  • This study was performed to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of cerebral infarction patieno (CI), compared with those of healthy subjects, as well as 2) to determine Sasang Constitution in CI and healthy subjects. 1. Calibrated in Gwan, the amount of energy(Energy), height of main peak(H1), height of aorticvalley(H2), height of aortic peak(H3), total area of pulse wave(At), and area of main peak width(Aw) of the CI group were higher than those of the healthy group. 2. Calibrated in Cheek, Energy, H1, H2, H3, height of valve valley(H4), At, Aw, and main peak angle(MPA) of the CI group were higher than those of the healthy group. 3. Among the healthy (subjects) group, Taeumin showed the highest contact pressure(CP) and height of valve peak(H5) calibrated in Chon. The main peak width divided by whole time of pulse wave(MPW/T) calibrated in Gwan and Cheok, was highest in Soyangin and was lowest in Taeumin. The H3 divided by H1(H3/H1) and the time to valve valley minus the time to main peak and divided by T[(T4-T1)/T] calibrated in Cheek were highest in Soyangin. The time to main peak(T1) was longest in Soumin. 4. Among the CI group, At calibrated in Chon was widest in Taeumin and was narrowest in Soumin The time to aortic peak(T3) calibrated in Cheek was longest in Soumin and was shortest in Soyangin. The time to valve peak(T5) was shortest in Soyangin. 5. There were main effects of cerebral infarction in the area of systolic period(As) and area of diastolic period(Ad) calibrated in Chon, Energy calibrated in Cwan, and Energy, H1, H2, H3, (H4+H5)/Hl, and MPA calibrated in Cheek. 6. There were main effects of Sasang Constitution in (T4-T1)/T, area of systolic period(As), and Ad calibrated in Chon. 7. The interactions between the cerebral infarction and Sasang Constitution were observed in H5/H1 , T, At, As, Ad, and MPA calibrated in Chon, H4, T4, (T4-T1)/T, As, and Ad calibrated in Cwan, and 74,75, and MPW calibrated in Cheok. Therefore, we concluded that pulse analyzer was useful to determine the risk degree of cerebral infarction and Sasang Constitution.

들기 작업에서 높이와 각도 변화가 발 부위에 미치는 스트레스에 관한 연구 (An Analysis of Stress on Foot by Lifting Height and Angle)

  • 여민우;이상도;이동춘
    • 대한인간공학회지
    • /
    • 제25권3호
    • /
    • pp.17-24
    • /
    • 2006
  • In this paper, we propose a stress analysis on foot by lifting task attitudes. Maximum force and peak pressure were measured on 8 body regions by Pedar system in order to analysis the stress which is affected by task style and angle on foot when Manual Materials Handling task. As for the peak pressure of the whole foot as to the task height during the lifting task, the height from Knuckle to Shoulder was the least in the peak pressure. Also, as for the maximum force and the peak pressure of the whole foot as to the task angle during the lifting task, it could be seen that the more an angle increases, the stress influencing on a foot jumps. As for the maximum force and the peak pressure by foot region as to the task height in case of the lifting task, the height from Knuckle to Shoulder is indicated the smallest value in the maximum force and the peak pressure, thus there is necessary to attain the work design that considered this. Also, as for the maximum force by foot region as to the task angle in case of the lifting task, 0° tasking is indicated to be least, thus there is necessity to be attained the tasking design in a bid to prevent the existence of an angle. The results of this paper are thought to be helpful to the suitable work design, to the prevention of musculoskeletal disorders related to the lower limbs, and to the design of ergonomic safety shoes.

복부 기능적전기자극이 목척수손상환자의 최대기침유량과 노력성폐활량에 미치는 효과 (Effects of Abdominal Functional Electrical Stimulation on Peak Cough Flow and Forced Vital Capacity in Patients with Cervical Spinal Cord Injury)

  • 안혜인;고영범;윤선화;차수환;전용진
    • 대한통합의학회지
    • /
    • 제7권2호
    • /
    • pp.85-93
    • /
    • 2019
  • Purpose : The purpose of this study was to investigate the effects of abdominal functional electrical stimulation on peak cough flow and forced vital capacity in patients with cervical spinal cord injury. Methods : The study examined 20 patients with cervical spinal cord injury. The subjects were randomly divided into two groups. All subjects performed conservative physical therapy for 30 minutes. The experimental group also underwent abdominal functional electrical stimulation for at least 20 minutes per day. Abdominal functional electrical stimulation was applied to the rectus abdominis muscle twice each day, three times a week, for four weeks. In all subjects, the peak cough flow was measured using a peak flow meter and forced vital capacity was assessed using a spirometer. Results : The experimental group showed a significant increase in peak cough flow and forced vital capacity in pre-post measurements (p<.05), while the control group showed a significant increase only in peak cough flow. Conclusion : These findings suggest that conservative physical therapy in combination with the abdominal functional electrical stimulation can improve peak cough flow and forced vital capacity in patients with cervical spinal cord injury.

Effects of Step Length Change on Kinetic Characteristics While Stepping Over an Obstacle From a Position of Quiet Stance in Young and Elderly Adults: A Preliminary Study

  • Kim, Hyeong-Dong
    • 한국전문물리치료학회지
    • /
    • 제14권4호
    • /
    • pp.66-74
    • /
    • 2007
  • The aim of the present study was to investigate age-related differences in stepping behavior in response to sensory perturbations of postural balance. The participants for this study were 2 healthy elderly adults (mean age=76.0) and 2 younger adults (mean age=25.5). Subjects were asked to step over a 10 cm high obstacle at self-paced speed with the right limb to land on the primary target (normal step length) that is 10 cm in diameter. However, if, during movement, the light was illuminated, then the subject had to step on the secondary target (long step length). It was planned that the onset of the light would be prior to peak Fx of swing limb, between swing peak Fx and swing toe-off, and after swing toe-off. In the younger adults these secondary visual cues were provided at mean times of 240 ms (standard deviation (SD)=11), 402 ms (SD=13), and 476 ms (SD=88) following the movement onset. Corresponding mean times for the healthy elderly were 150 ms (SD=67), 352 ms (SD=39), and 562 ms (SD=115). Results showed great changes in both group and visual cue condition in Fx ground reaction forces and temporal events following the swing toe-off. Swing limb acceleration force (Fx) and stance peak Fx1 was much greater in the young adults compared to the older adults. Both young and older adults increased stance peak Fx2 in the visual cue condition compared to normal stepping. There was no difference in stance peak Fx2 between the visual cue conditions in both groups. Similarly, the time to stance peak Fx2 was much longer for the visual cue condition than for the normal stepping. It was not different between the visual cue conditions in the young adults, but in the elderly mid and late cue was much greater than early cue. In addition, time to stance peak Fx2 and swing and stance time were much longer in the older adults compared to the young adults for the visual cue conditions. These results suggest that unlike young adults, elderly adults did not flexibly modify their responses to unexpected changes in step length while stepping over obstacles.

  • PDF

오수관 설계유량 산정법이 설계유속에 미치는 영향 (Design Flow Velocity Changes According to the Design Flow Determination Methods in the Sanitary Sewer)

  • 현인환;원승현;김형준;이제인
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.749-757
    • /
    • 2005
  • The present study analyzed actual cases of designed flow estimation method and designed flow rate of sewage pipe lines. In order to examine the effects of peak-hour demand factor estimation with given daily highest peak loading, we analyzed its effects on designed flow rate with changing the peak-hour demand factor from 2.0 to 10.0. The results of this study are as follows. When reviewing the recent designs, we found that 59.4% of pipe line with 250mm and 300mm diameter, which fall under minimum allowable pipeline did not meet the minimum velocity which is specified as 0.6m/sec in design standards. The pipe line that have minimal access population or have very low slope did not satisfy the minimum velocity. In estimating the designed sewage flow, the applied daily highest peak loading and hourly highest peaking loading were the load factor for the entire population of the planned area, and for the peak loading of the initial pipes connected to a very small population, we applied the same factor as that applied to the entire area and, as a result, the hourly highest flow was underestimated. Because, in case of the initial pipes, the method of applying the same peak loading to all subject areas is highly possible to produce underestimated design flow, when estimating the designed flow of the initial pipes connected to a small population need to adopt a rational flow factor according to the size of population. For this, it is considered to investigate and analyze raw data on daily and hourly variation of sewage flow.