• Title/Summary/Keyword: peak power

Search Result 2,626, Processing Time 0.035 seconds

Double Two Switch Forward Transformer-Linked Soft-Switching PWM DC-DC Power Converter with Tapped Inductor Filters

  • Moisseev Serguei;Koudriavtsev Oleg;Hiraki Eiji;Nakamura Mantaro;Nakaoka Mutsuo;Hamada Satoshi
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.193-197
    • /
    • 2001
  • This paper presents a novel circuit topology of the double two-switch forward type high frequency transformer linked soft-switching PWM DC-DC power converter with tapped inductor filters that can operate under a condition of the low peak voltage stress across the power semiconductor devices and lowered peak current stress through the transformer for some high power applications. This circuit topology of an interleaved two-switch forward soft-switching power converter is proposed in the order to minimize an idle circulating current due to the tapped inductor filter without of any additional active auxiliary resonant-assisted snubber circuits, such as active resonant DC link snubbers and AC link snubbers, active resonant commutation leg link snubbers. The unique advantages of this power converter are less power circuit components and power semiconductor devices, constant frequency PWM scheme, cost effective configuration and wider soft-switching PWM operation range under PWM power regulations load variations. The practical effectiveness of the proposed soft-switching converter circuit topology is tested by simulations and is proved by experimental results received from the 500W-100kHz breadboard setup.

  • PDF

The Effects of High-intensity Combined Training Program on Cardiorespiratory Function, Isokinetic Trunk Strength and Anaerobic Power of Canoe Athletes (고강도 복합 훈련 프로그램이 카누선수의 심폐기능, 체간 등속성 근력과 무산소성 파워에 미치는 영향)

  • Jung, Jong-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.17-27
    • /
    • 2020
  • The purpose of this study is to confirm the effects of a 6-week high-intensity combined training program on canoe athletes' cardiorespiratory function, isokinetic trunk strength, and anaerobic power. For the purpose of this study, the high-intensity combined training program was applied to 9 high-school canoe athletes. The high-intensity combined training program consists of aerobic exercise performed 2 times a week (Tuesday and Thursday), anaerobic exercise performed 3 times a week (Monday, Wednesday, and Friday), and flexibility exercise performed 5 times a week. The core of the high-intensity combined training program was the anaerobic training program performed with 100% weight for repetition; otherwise, the existing training method was divided into the percentage (%) of the 1RM. The aerobic exercise and the gym ball exercise are performed subsidiarily. Results showed that there was a statistically significant difference in height and muscle mass, whereas there was no statistically significant difference in weight, body fat percentage, and BMI followed by the high-intensity combined training program. There were statistically significant differences in maximum oxygen uptake and total exercise time. The angular velocity of 30°/sec showed a statistically significant difference in the peak torque item of flexors only. Also, the angular velocity of 120°/sec showed a statistically significant difference in the total work item of extensors only; however, there was no statistically significant difference in all the items of peak power, average power, and peak drop. In conclusion, it seems that the high-intensity combined training program may be applied as a training program for enhancing canoe athletes' performance. For further studies, more than 6 weeks training program with more participants would show improved results of isokinetic strength and anaerobic power in athlets.

Isokinetic Strength Capacity Between Elite Athletes and Taekwondo Player (엘리트 육상선수와 태권도 선수의 등속성 운동능력에 관한 비교 연구)

  • Kim, Hyun-Mi;Lee, So-Yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2691-2697
    • /
    • 2011
  • The purpose of the dissertation is to offer basic data available for being conducive to application of a training program by comparatively analyzing the players' physical strength, the knee joint, a hip joint, power of the trunk joint and muscle power in order to study isokinetic strength and muscle power between short distance athletes and Taekwondo players. This study measured peak power, %Body weight peak power, always power, and %Body weight peak power targeting 8 male athletes and 8 male Taekwondo players who warmed up 10 minutes before from the test to reduce repulsion and unfamiliarity at the instrument. The power of the knee joint($60^{\circ}$/sec), muscle power($180^{\circ}$/sec), were measured by using HUNOM(U.S.A). As a result of the physical strength, statistically, short distance athletes were indicated to be better in muscle strength, muscular endurance than Taekwondo players, and there was no significant difference between flexibility, power, and muscular endurance. Although the short distance athletes were indicated to be better in right and left muscle strength of knee joint than Taekwondo player, there was no significant difference and Taekwonde players were indicated to be higher at the right and left muscle power than short distance athletes.

Characterization of the Spiral Type Fault Current Limiters Using High-$T_c$ Superconducting Thin Films (나선형태로 제작된 고온초전도 한류기의 특성해석)

  • 정동철;박성진;강형곤;최효상;곽민환;임해용;황종선;최명호;추철원
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.6
    • /
    • pp.518-524
    • /
    • 2001
  • We report the current limiting properties of superconducting fault current limiters (SFCL). Our SFCL was patterned in a spiral type on a YB $a_2$C $u_3$$O_{7-x}$(YBCO) film deposited using rf sputtering techniques and was coated with a gold shunt layer in order to disperse the heat generated at hot spots in the YBCO film. Current increased up to 13.5 $A_{peak}$ at 60 Hz for the voltage of 13 $V_{peak}$, which is the minimum quench point, and increased up to 17.6 $A_{peak}$ at 60 Hz fo the voltage fo 141.4 $V_{peak}$. The quench completion time was 5 msec at 13 $V_{peak}$ and 4 msec at 141. $V_{peak}$ respectively. we think that this architecture using spiral-type SFCL can be useful for the protection of the power delivery systems from fault currents.s. currents.s.

  • PDF

$S^{35}$(1,2-dichloro vinyl) L-Cysteine의 소에 의(依)한 대사물(代謝物)의 분리(分離)

  • Kim, Jae-Uk
    • Applied Biological Chemistry
    • /
    • v.2
    • /
    • pp.36-39
    • /
    • 1961
  • It has been ascertained that S-(1, 2-dichlorovinyl) L-cysteine (DCVC) is probably the toxic component in the trichloro-ethylene extracted soybean oil meal on the bovine. For the study of the metabolites of DCVC, the components with radioactive $S^{35}$-in the urine of the calf, to which $S^{35}$-DCVC was administrated, were separated using of cellulose powder with propanol-water (70:30 V/V) which is easily removable by evaporation. As the results followings were obtained: Peak 1, which shows fractions containing single $S^{35}$-radioactive components, whose Rf is 0.815 Peak 2, which shows fractions containing jingle $S^{35}$-radioactive component, whose Rf is 0.447 Peak 3, which shows fractions containing both $S^{35}$-radioactive components whose Rfs are 0.090 and 0.171 Peak 4, which shows fractions containing single $S^{35}$-radioactive component, whose Rf is 0.142. Peak 5, which shows fractions containing single $S^{35}$-radioactive component, whose Rf is 0.084. Besides these, two of small peak were obtained. Although, the resolving power of the cellulose powder column is not sufficient, it is applicable for the study of the components of metabolytes of DCVC conveniently with the rest of removable solvent easily. Also the components with radioactive $S^{35}$ in the feces of the calf were separated using citrate buffer gradient system of Moore and stein. As the results; three $S^{35}$-radioactive components were separated.

  • PDF

A Study on the Causality between Electric Reserve Margin, Electricity Tariff, Renewable Energy, Economic Growth, and Concurrent Peak in Winter and Summer: OECD Panel Analysis (전력예비율과 전기요금, 신재생, 경제성장, 동·하계 동시피크 간 인과관계 연구 : OECD 패널 분석)

  • Lee, Jung-Ho;Park, Kyung-Min;Park, Jung-Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1415-1422
    • /
    • 2018
  • In Korea, prior to 2011, the electric reserve margin followed the probabilistic reliability view and the planning reserve margin had been operated at about 15% based on the assumption that power outage was permitted within 0.5 days a year. However, after experiencing the shortage of the electric generation capacity in Sept. 15, 2011, the planning reserve margin was selected as 22% to improve the reliability of the electric supply. In this paper, using panel data of 28 OECD countries over the period 2000-2014 we attempted to empirically examine the linkage between reserve margin, electricity tariffs, renewable energy share, GDP per capita, and summer / winter peak-to-peak ratios. As a result, all four independent variables have been significant for the electric reserve margin, and in particular, we found that countries with similar peaks in winter and summer have operated 4.3% higher reserve margin than countries experiencing only summer peak.

Dependence of spacecraft anomalies at different orbits on energetic electron and proton fluxes

  • Yi, Kangwoo;Moon, Yong-Jae;Lee, Ensang;Lee, Jae-Ok
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.45.2-45.2
    • /
    • 2016
  • In this study we investigate 195 spacecraft anomalies from 1998 to 2010 from Satellite News Digest (SND). We classify these data according to types of anomaly : Control, Power, Telemetry etc. We examine the association between these anomaly data and daily peak particle (electron and proton) flux data from GOES as well as their occurrence rates. To determine the association, we use two criteria that electron criterion is >10,000 pfu and proton criterion is >100 pfu. Main results from this study are as flows. First, the number of days satisfying the criteria for electron flux has a peak near a week before the anomaly day and decreases from the peak day to the anomaly day, while that for proton flux has a peak near the anomaly day. Second, we found a similar pattern for the mean daily peak particle (electron and proton) flux as a function of day before the anomaly day. Third, an examination of multiple spacecraft anomaly events, which are likely to occur by severe space weather effects, shows that anomalies mostly occur either when electron fluxes are in the declining stage, or when daily proton peak fluxes are strongly enhanced. This result is very consistent with the above statistical studies. Our results will be discussed in view of the origins of spacecraft anomaly.

  • PDF

Peak Load Estimation of Pole-Transformer in Summer Season Considering the Cooling Load of Customer (수용가 냉방부하를 고려한 하절기 주상변압기 최대부하 추정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Kim, Gi-Hyun;Im, Jin-Soon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, we propose a method for estimating the peak load of pole-transformer in summer season considering the degree of cooling load possession in customer. The cooling load of customer is selected as the most reliable parameter of peak load in summer season. The proposed estimation method is restricted to the aspect of load management for pole-transformer. The main concept of proposed method is that the error of peak load estimation using load regression equation reduces with considering the degree of cooling load possession in customer. We propose an index for estimation of cooling load possession in each customer. The proposed index is defined as cooling load possession in customer (CLPC) and obtained from the increment of monthly electric energy. The membership function for deciding the uncertainty of cooling load possession in customer is used. The database of pole-transformer in Korea Electric Power Corporation (KEPCO) is used for case studies. Through the case studies, we verify that the proposed method reduces the error of peak load estimation than the conventional method in domestic.

  • PDF

Analysis of the spectral characteristics of white light-emitting diodes under various thermal environments

  • Jeong, Su-Seong;Ko, Jae-Hyeon
    • Journal of Information Display
    • /
    • v.13 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • An empirical functional form was suggested for the analysis of the emission spectrum of high-power light-emitting diode (LED) consisting of a sharp blue peak from the LED chips and a broad yellow peak from the phosphor layer. The peak positions, half widths, shape parameters, and amplitudes of these two peaks were reliably obtained as a function of the temperature, and the results were discussed qualitatively in relation with the junction temperature. The adoption of an inert liquid was found to have significantly reduced the LED temperature and the color shift of the emitted light. The phenomenological approach used in this study may be helpful in the simulation of the LED spectrum under various thermal conditions, and may thus be helpful in the improvement of the device performance.

A Study on Operation Scheme of STS with Emergency Generator for Peak Shedding (첨두부하 저감을 위한 비상발전기 연계형 STS 운영 방안에 관한 연구)

  • Kim, Chang-Hwan;Rhee, Sang-Bong;Kim, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.155-156
    • /
    • 2015
  • Recently, electricity consumption has rapidly increased along with economic growth. The operating strategy using emergency generator is aimed, to resolve a demand response management. For strategy of peak shedding using emergency generator, it is essential to introduce the fast transfer switching device. One of the most effective solutions is to use a static transfer switch (STS) based on thyristor. However, the characteristic of natural commutated SCR thyristor should anticipate short duration voltage sag. STS system thus requires more than a quarter cycle to successfully complete transfer process. This paper proposes the operation scheme of the STS system using the forced-commutation technique to mitigate instantaneous voltage sag during peak transfer process. Proposed STS system improved turn-off characteristic thus accomplishes the peak load shedding satisfied power quality. Performance of the proposed STS system is evaluated using electromagnetic transient program (EMTP) to confirm the effectiveness.

  • PDF