• 제목/요약/키워드: peak power

검색결과 2,626건 처리시간 0.024초

Asymptotic Capacity Analysis in Multipoint-to-Point Cognitive Radio Networks with an Arbitrary Peak Power

  • Ji, Jianbo;Chen, Wen;Sun, Shanlin
    • Journal of Communications and Networks
    • /
    • 제15권6호
    • /
    • pp.576-580
    • /
    • 2013
  • In this paper, we investigate the capacity of a multipoint-to-point cognitive radio network. In existing works, the asymptotic capacity is only obtained in the high peak power region at secondary transmitter (ST) or obtained without considering the interference from primary transmitter (PT) for easy analysis. Here, we analyze the asymptotic capacity by considering an arbitrary peak power at the ST and the interference from the PT based on extreme value theory. Simulation results show that our approximated capacity is well-matched to the exact capacity. Furthermore, the scaling law of our capacity is found to be double logarithm of the number of secondary users.

IEM-based Tone Injection for Peak-to-Average Power Ratio Reduction of Multi-carrier Modulation

  • Zhang, Yang;Zhao, Xiangmo;Hou, Jun;An, Yisheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권9호
    • /
    • pp.4502-4517
    • /
    • 2019
  • Tone Injection (TI) scheme significantly reduces the peak-to-average power ratio (PAPR) of Multicarrier Modulation (MCM). However, the computational complexity of the TI scheme rises exponentially with the extra freedom constellation number. Therefore, a novel immune evolutionary mechanism-based TI scheme is proposed in this paper to reduce the computational complexity. By restraining undesirable degeneracy during the processing, this IEM scheme can dramatically increase the population fitness. Monte Carlo results show that proposed IEM-based TI scheme can achieve a significant PAPR and BER improvement with a low complexity.

Switching-Mode BJT Driver for Self-Oscillated Push-Pull Inverters

  • Borekci, Selim;Oncu, Selim
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.242-248
    • /
    • 2012
  • Self oscillating current fed push pull resonant inverters can be controlled without using special drivers. Dc current flows through the choke coil and the power switches, although the driving signals of the power switches are sinusoidal. When the base current is near zero, the transistors cannot be operated in switching mode. Hence higher switching power losses and instantaneous peak power during off transitions are observed. In this study, an alternative design has been proposed to overcome this problem. A prototype circuit has been built which provides dc bias current to the base of the transistors. Experimental results are compared with theoretical calculations to demonstrate the validity of the design. The proposed design decreases the peak and average power losses by about 8 times, when compared to conventional designs.

전력 케이블용 저밀도 폴리에틸렌의 냉각 조건에 따른 기계적 및 유전손실에 관한 연구 (A study on the Dynamic Mechanical and Dielectric Loss according to Quenched Condition in Low Density Polyethylene fer Power Cable)

  • 김재환;권병휘;박재준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권5호
    • /
    • pp.27-37
    • /
    • 1992
  • We studied the dielectric and dynamic mechanical losses according to the quenching condition in low density polyethylene being used to power cables. According to severe quenching condition, characteristics of the temperature in internal friction los peak have decreased the magnitude of loss peak as amorphous region lengthen. From now on, the frequency dependent characteristics of dielectric loss have investigated at room temperature, and the dielectric loss peak due to interface polarization, between crystal and amorphous region, occurs about 30[Hz], and that, the peak due to orientation polarization in correspondence to the loss peak in internal friction has observed at about 3 [MHz]. As quenching velocity increased, the effect on quenching condition about the dielectric loss has decreased the magnitude of the loss peak. Thus, estimation has been carried out on the activation energies nd the degree of crystallinity by means of X-ray diffraction are obtained as follows: room quenching : 26.4 [kal/mole] and 54.73 [%], ice quenching : 25.6 [kcal/mole] and 48.47 [%], liquid nitrogen quenching specimens : 22.56 [kcal/mole] and 40.95 [%].

  • PDF

체간 굴곡근과 신전근의 수축 형태에 따른 등속성 근력평가 (The Isokinetic Strength Evaluation of Trunk Flexors and Extensors by Contranction Type)

  • 김양희;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제10권2호
    • /
    • pp.57-69
    • /
    • 1998
  • The role of eccentric muscle activities in functional everyday activities and sport is important and equally significant to concentric conditions. Eccentric and concentric exercise and evaluation are, therefore, very important. The purposes of this study were to measure eccentric md concentric peak torgue, percentage of peak torque, average power and percentage of average power of trunk flexors and extensors by using the Cybex NORM isokinetic dynamometer, and to standardize the value obtained. Thirty four young volunteers were tested, 17 females and 17 males, who had no history of back pain or abnormality. Each subjects were tested on three repetitions for isokinetic concentric and eccentric contraction at 5 velocities. The results were as follows; 1) Peak torque percent body weight of eccentric contraction were significantly greater than concentric contraction at each angular velocity and in trunk flexors and extensors(p<0.01). 2) Peak torque percent body weight of concentric contraction were significantly decreased as the angular velocity increased both male and female(p<0.01). 3) Peak torque percent body weight of eccentric contraction were not significantly changed as the angular velocity increased both male and female(p<0.05), 4) Peak torque percent body weight of male were significantly greater than female at each angular velocity and in concentric and eccentric contraction of trunk flexors and extensors(p<0.01)

  • PDF

열적 피로에 의한 전원코드의 발화 특성과 전기화재 분석에 관한 연구 (A Study on the Electrical-Fire Analysis and Firing Characteristics of Power Cord by Thermal Stress)

  • 최충석;송길목;김향곤;김동욱;김동우
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2003년도 춘계학술논문발표회논문집
    • /
    • pp.164-170
    • /
    • 2003
  • In this paper, we studied on the firing characteristics and electrical fire analysis of power cord deteriorated by thermal stress. The cross section of PVC insulating cord deteriorated by indirect flame decreased through heat convection. PVC insulating cord deteriorated by direct flame was bumpy shape. The exothermic peak of normal cord was shown at ($526.7^{\circ}C$), but the peaks or on(heat treatment temperature) ($150^{\circ}C$) cord was shown at ($299.6^{\circ}C$) and [$502.2^{\circ}C$]. The exothermic peaks according to high temperature were similar to those of amorphous carbon. In the FT-IR analysis, the absorption peak of normal cord indicated double bond of oxygen and carbon in benzene ring at 1720.0$cm^{1}$. As the HTT was high, the height of characteristic peak decreased and the peak of carbonyl group was shown at about 1625.7$cm^{-1}$. The characteristic peak of single bond(O-H) was shown at about 3479.2$cm^{-1}$. In case of the internal part of wire covering deteriorated by over current, the characteristic peak were shown at about 3417.3$cm^{-1}$ and 1600.2$cm^{-1}$. The above results show that we can distinguish the differences according to the fire pattern through the internalㆍexternal analysis of wire covering deteriorated by heat.

  • PDF

제주도 지역별 대용량 태양광발전소들의 여름 피크타임 기여도 연구 (Contribution of Large-Scale PV Plants in the Respective Region of the Jeju Island to Electric Power during Summer Peak Times)

  • ;고석영;사공준;권훈;이개명
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1873-1878
    • /
    • 2017
  • Both the introduction of the Renewable Energy Portfolio Standard (RPS) system into the electric energy market in 2012 and a decrease in the cost of constructing photovoltaic (PV) power plants have been increasing the number of MW PV plants in South Korea. Jeju Island is located at the center of three nations, South Korea, China and Japan, and its provincial government declared in 2012 that the island will be a clean region where greenhouse gases are not emitted by 2030. The Jeju provincial government is now doing its best to install PV plants and wind farms to realize a carbon-free island. In this study we investigated contribution of MW PV plants to the power of the electric grid during summer peak times on Jeju Island. Mt. Halla the highest mountain in South Korea, is located at the center of Jeju Island, and we divided the island into four regions and carried out analyses of a total of 24 PV plants. The average contribution of the PV plants in the respective region to electric power of Jeju Island during summer peak times was investigated and compared with those of the other regions. The best average contribution during the 12.5% maximum load period was obtained from the PV plants in the western region, and the value was 33% during 2015 and 2016.

시계열 모형을 이용한 일별 최대 전력 수요 예측 연구 (Daily Peak Load Forecasting for Electricity Demand by Time series Models)

  • 이정순;손흥구;김삼용
    • 응용통계연구
    • /
    • 제26권2호
    • /
    • pp.349-360
    • /
    • 2013
  • 최근 일별 최대 전력수요 예측은 전력설비 계획 및 운용에 매우 중요한 사안으로 주목받고 있다. 본 연구는 일별 최대 전력수요 예측을 위하여 대표적 시계열 모형을 소개하고, 예측의 성능 비교를 위하여 RMSE(Root mean squared error)와 MAPE(Mean absolute percentage error)를 사용한다. 연구결과로 보완된 Holt-Winters 모형과 Reg-ARIMA 모형이 다른 모형에 비하여 우수한 예측 성능을 보였다.

Adaptive Digital Predictive Peak Current Control Algorithm for Buck Converters

  • Zhang, Yu;Zhang, Yiming;Wang, Xuhong;Zhu, Wenhao
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.613-624
    • /
    • 2019
  • Digital current control techniques are an attractive option for DC-DC converters. In this paper, a digital predictive peak current control algorithm is presented for buck converters that allows the inductor current to track the reference current in two switching cycles. This control algorithm predicts the inductor current in a future period by sampling the input voltage, output voltage and inductor current of the current period, which overcomes the problem of hardware periodic delay. Under the premise of ensuring the stability of the system, the response speed is greatly improved. A real-time parameter identification method is also proposed to obtain the precision coefficient of the control algorithm when the inductance is changed. The combination of the two algorithms achieves adaptive tracking of the peak inductor current. The performance of the proposed algorithms is verified using simulations and experimental results. In addition, its performance is compared with that of a conventional proportional-integral (PI) algorithm.

Program Cache Busy Time Control Method for Reducing Peak Current Consumption of NAND Flash Memory in SSD Applications

  • Park, Se-Chun;Kim, You-Sung;Cho, Ho-Youb;Choi, Sung-Dae;Yoon, Mi-Sun;Kim, Tae-Yun;Park, Kun-Woo;Park, Jongsun;Kim, Soo-Won
    • ETRI Journal
    • /
    • 제36권5호
    • /
    • pp.876-879
    • /
    • 2014
  • In current NAND flash design, one of the most challenging issues is reducing peak current consumption (peak ICC), as it leads to peak power drop, which can cause malfunctions in NAND flash memory. This paper presents an efficient approach for reducing the peak ICC of the cache program in NAND flash memory - namely, a program Cache Busy Time (tPCBSY) control method. The proposed tPCBSY control method is based on the interesting observation that the array program current (ICC2) is mainly decided by the bit-line bias condition. In the proposed approach, when peak ICC2 becomes larger than a threshold value, which is determined by a cache loop number, cache data cannot be loaded to the cache buffer (CB). On the other hand, when peak ICC2 is smaller than the threshold level, cache data can be loaded to the CB. As a result, the peak ICC of the cache program is reduced by 32% at the least significant bit page and by 15% at the most significant bit page. In addition, the program throughput reaches 20 MB/s in multiplane cache program operation, without restrictions caused by a drop in peak power due to cache program operations in a solid-state drive.