• Title/Summary/Keyword: pcbs

Search Result 495, Processing Time 0.027 seconds

ESTIMATION OF RAIN SCAVENGING RATIO FOR PARTICLE BOUND POLYCYCLIC AROMATIC HYDROCARBONS AND POLYCHLORINATED BIPHENYLS

  • Kim, Hyeon-Kook;Shin, Yong-Seung;Lee, Dong-Soo;Song, Byung-Joo;Kim, Jong-Guk
    • Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.33-44
    • /
    • 2006
  • The objective of this study was to develop and assess a method for estimating the rain scavenging ratios (RSRs) of particle-bound PAHs and PCBs using measured scavenging ratio of particulate matters (PM) and routinely available data of physico-chemical properties of PM. Paired atmospheric and rainwater sampling was conducted for a total of 4 rain events. Assuming equilibrium partitioning in rainwater-gas-PM system, an equation was derived for estimating the RSR of particle-bound chemicals as a function of RSR of PM and three equilibrium partition constants (i.e. dimensionless Henry's law constant, gas-particle partition coefficient, and water-particle partition coefficient). For all PAHs, the model significantly under-predicted the RSR while the model prediction for PCBs agreed with observation mostly within a factor of 5. The RSR model for the chemicals is of limited use as its accuracy critically depends on how close the observed partitioning of the chemicals in the gas-PM-rainwater system is to that estimated under the equilibrium assumption.

Disposal of Polychlorinated Biphenyls(PCBs) by a Combined Chemical with Thermal Treatment (화학 및 열적 처리를 이용한 폴리염화바이페닐(PCB)의 제거)

  • Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.286-293
    • /
    • 1999
  • A comnprehensive process which combines chemical with thermal treatment by controlled counterflow oxidation has been developed for disposal of PCBs in transformer oil. PCBs which not completely removed by chemical treatment, after being filtered with appropriate adsorbent during the oil circulations, was thermally treated. Destruction efficiencies of better than 99.99% was obtained, with no measurable formation of PCDDs (polychlorinated dibenzo-p-dioxins) or PCDFs (polychlorinated dibenzofurans). The combination also permits high recovery of oil and inorganic supports from scrap power transformers. The process is environmentally benign, easy to use and less capital intensive than other available technologies.

  • PDF

Decontamination of PCBs by Hybrid Adsorption/Regeneration on Granular Activated Carbon (입자상 활성탄의 흡착과 재생에 의한 PCBs 오염제거)

  • Hong, Yong Pyo;Choe, Jong Ha
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.2
    • /
    • pp.117-124
    • /
    • 2002
  • Counterflow oxidation was developed and evaluated for treatment of organics that adsorbed in/on granular activated carbon(GAC). This reaction is a method that destructs and removes organics adsorbed, at the same time, regenerates waste carbon, uti lizing a self-sustained flame which propagates itself ina direction counter to the oxygen flow. The results showed that the mass loss of carbon and flam temperature were strongly dependent on the flow rate of oxyen, adsorptive capability of regenerated carbon completely was recovered, as well as destrution and removal efficiency of thermally stable PCBs was achieved with the value of better than 99.99%.

Study on the Causes of Malfunctions of PCBs Applied to the Power Saving Mode of Electrical Systems and its Solution (전기시스템의 절전모드에 적용되는 PCB의 오작동 원인 개선에 관한 연구)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.51-55
    • /
    • 2013
  • The purpose of this study is to find the causes of malfunctions and defective operation of printed circuit boards(PCBs) built into home refrigerators to perform power saving functions. This study performed an electrostatic test of a PCB built-in using an Auto Triggering system; lightning and impulse tests using an LSS-15AX; and an impulse test using an INS-400AX. From the analysis of a secondarily developed product, it was found that electrostatic discharge(ESD) caused more malfunctions and defective operations than electric overstress(EOS) due to overvoltage. As a result of increasing the condenser capacity of the PCB circuit, withstanding voltage was increased to 7.4 kV. In addition, this study changed the power saving mode and connected a varistor to the #2 pin of an IC chip. As a result, the system consisting of all specimens of a finally developed product was operated stably with an applied voltage of less than 10 kV. This study found it necessary to perform quality control at the manufacturing stage in order to reduce the occurrence of electrostatic accidents to IC chips built into a PCB.

Distribution and exposure assessment of indicator PCBs in Food (식품 중 indicator PCBs의 분포와 노출평가)

  • Oh, Keum-Soon;Suh, Jung-Hyuck;Paek, Ok-Jin;Park, Seong-Soo;Na, Young-Joon;An, Yeong-Sun;Kim, Mee-Hye;Lee, Kwang-Ho
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.312-321
    • /
    • 2010
  • Seven indicator PCBs (IUPAC nos 28, 52, 101, 118, 138, 153, 180 congeners) concentrations were measured in food samples including cereal (polished rice), meats, eggs, milk and dairy products, and fisheries and products as representation for the general Korean populations during 2006-2007, and was analyzed using isotopic dilution method. Fishes had the highest average level as 39.8 ng/g, 1.4 ng/g for milk and dairy products, and 0.9 ng/g for meats. The hairtail out of fishes was contaminated at the level of 15.4 ng/g, 5.4 ng/g for pacific mackerel and spanish mackerel, and 4.5 ng/g for yellow croaker. The ratio for indicator PCBs in overall food was contributed as follows; 35.8% for PCB-153, 16.2% for PCB-138, 16.1% for PCB-101, 13.4% for PCB-118, 8.8% for PCB-180, 6.9% for PCB-52, and 2.9% for PCB-28. The hexa-CBs including PCB-153 and 138 were more predominated, and the next was penta-CBs including PCB-101 and 118 in food. For estimated daily intake (EDI) in average and $95^{th}$ percentile, fishes and products out of overall food were taken to represent over 50%. However, it was estimated that there was no adverse health effect for Korean.

The Relationship among the Indicator PCBs in Breast Milk and Dietary Habits and Demographic Factors in Women Living in Urban Areas (대도시에 거주하는 여성의 모유 중 Indicator PCBs와 식이습성 및 인구통계학적 인자간의 관계)

  • We, Sung-Ug;Kim, Ki-Ho;Cho, Bong-Hui;Cho, Yu-Jin;Yoon, Cho-Hee;Min, Byung-Yoon
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.3
    • /
    • pp.199-207
    • /
    • 2010
  • In this study, breast milk levels of indicator polychlorinated biphenyls (PCBs) were estimated, and statistics drawn, for 22 Koreans in the general population, aged 26-38, who had resided in metropolitan areas for more than 5 years without occupational exposure to organochlorine pollutants. Concentrations of indicator PCBs were measured using the isotope dilution method with a high resolution gas chromatograph/high resolution mass detector, which provided accurate and precise data for investigation of trends, and international comparisons. The geometric mean of total indicator PCB levels was 22.3 ng/g lipid, which is significantly lower than the level in individuals from European countries. Overall, the geometric mean and 95th percentile of the most abundant congener PCB 153 were 8.04 ng/g lipid and 16.4 ng/g lipid, respectively. PCB congeners 138, 153 and 180 together accounted for about 75% of the indicator congeners analyzed. Breast milk total indicator PCB concentrations were significantly associated with age and parity, but not with body mass index (BMI), rate of body weight increase, or smoking habits. The geometric mean level of PCB 153 in breast milk from mothers with a pre-pregnant BMI < $21\;kg/m^2$ was significantly higher than in pre-pregnant women with a BMI of ${\geqslant}\;21\;kg/m^2$ (p<0.05). Women who ate more fish, meat, and milk products did not have significantly higher total indicator PCB levels than those who ate less of these products, but a significant difference in PCB 153 levels was demonstrated between the subjects consuming higher (11.45 ng/g lipid) and lower (6.79 ng/g lipid) amounts of fish (p<0.05), after adjusting for confounders. These results suggest that age, parity and fish intake are the important factors affecting the concentrations of indicator PCBs in these subjects.

Application of ZVI/TiO2 towards Clean-up of the Contaminated Soil with Polychlorinated Biphenyls (ZVI/TIO2를 이용한 폴리염화비페닐로 오염된 토양 정화)

  • Jae Wook Park;Yun Jin Jo;Dong-Keun Lee
    • Clean Technology
    • /
    • v.29 no.2
    • /
    • pp.118-125
    • /
    • 2023
  • Once a site is contaminated with polychlorinated biphenyls (PCBs), serious environmental and human health risks are inevitable. Therefore, innovative but economical in situ remediation technologies must be immediately applied to the contaminated site. Recently, nanoscale zero-valent iron (nano-ZVI) particles have successfully been applied for the dechlorination of various chlorinated organic compounds like TCE, PCE and DDT, and they are considered to be environmentally safe due to the high abundance of iron in the earth's crust. Nano-ZVIs are much more reactive than granular ones, but tend to agglomerate due to their high surface energy and magnetic properties. In order to prevent them from being agglomerated toward larger particles, TiO2 was used as a support to immobilize the nano-ZVI particles as much as possible. 10wt% ZVI/TiO2 was prepared by adding NaBH4 slowly into an FeSO4/TiO2 aqueous slurry. In spite of their non-uniformity in size, the nano-ZVI particles were quite successfully dispersed onto the exterior surface of a non-porous TiO2 powder. The ZVI/TiO2 was then employed to degrade Aroclor 1242, a kind of PCBs standard, in spiked soil, and its reactivity towards the degradation of Aroclor 1242 was investigated. The fabricated ZVI/TiO2 degraded Aroclor 1242 in soil quite effectively, but the creation of remaining dechlorinated compounds, possibly high molecular weight hydrocarbons, in the soil was unavoidable.