• Title/Summary/Keyword: pavement structure

Search Result 172, Processing Time 0.034 seconds

Study on Analysis of the Proper Ratio and the Effects of Low Impact Development Application to Sewage Treatment District (하수처리구역 내 LID 적용에 대한 적정비율 및 효과분석 연구)

  • Shin, Hyun Suk;Kim, Mi Eun;Kim, Jae Moon;Jang, Jong Kyung
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1193-1207
    • /
    • 2013
  • Increase of impervious area caused by overdevelopment has led to increase of runoff and then the problem of flooding and NPS were brought up. In addition, as decrease of base flow made groundwater level to decline, a stream that dries up is issued. low impact development (LID) method which is possible to mimic hydrological water cycle, minimize the effect of development, and improve water cycle structure is proposed as an alternative. As introduction of LID in domestic increases, the study on small watershed is in process mainly. Also, analysis of property of hydrological runoff and load on midsize watershed, like sewage treatment district, is required, the study on it is still insufficient. So, area applying LID practices from watershed of Dongrae stream is pinpointed and made the ratio and then expand it to watershed of Oncheon stream. Among low impact development practices, Green Roof, Porous Pavement, and Bio- retention are selected for the application considering domestic situations and simulated with SWMM-LID model of each watershed and improvement of water cycle and reduction of non-point pollution loads was analysed. Improvement of water cycle and reduction of non-point pollution loads were analyzed including the property of rainfall and soil over long term simulation. The model was executed according to scenario based on combination of LID as changing conductivity in accordance with soil type of the watershed. Also, this study evaluated area of LID application that meets the efficiency of conventional management as a criteria for area of LID practices applying to sewer treatment district by comparing the efficiency of LID application with that of conventional method.

Sensitivity of NOx Removal on Recycled TiO2 in Cement Mortar (재생 이산화티탄을 혼입한 모르타르의 NOx 저감률 민감도 분석)

  • Rhee, Inkyu;Kim, Jin-Hee;Kim, Jong-Ho;Roh, Young-Sook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.388-395
    • /
    • 2016
  • This paper explores the photocatalytic sensitivity of cement mortar incorporated with recycled $TiO_2$ from waste water sludge. Basically, $TiO_2$ cluster sank down slowly to the bottom of cement mortar specimen before setting and hardening process. This leads the mismatch of $TiO_2$ concentration on the top and the bottom faces of a specimen. This poorly dispersed $TiO_2$-cement mortar naturally exhibits poor NOx removal efficiency especially on the top of cementitious structure. In architectural engineering application such as building or housing structures, one can simply filp over from the bottom so that more $TiO_2$ concentrated surface can be placed outward into the air. However, in highway pavement case, this could not be applicable due to in-situ installation of concrete pavement. Hence, the dispersion of $TiO_2$ cluster inside the cementitous material is getting important issue onto road construction application. To elaborate this issue, according to our results, silica fume, high-ranged water reducer, viscosity agent, blast furnace slag were not enhanced much of dispersion characteristics of $TiO_2$ cluster. The combination of foaming agent and accelerator of hardening with viscosity agent and small grain size of fine aggregate may help the dispersion of $TiO_2$ inside cementitious materials. Even though the enhanced dispersion were applied to the specimen, NOx removal efficiency doest not change much for the top surface of the specimen. This concurrently affected by the presence of tiny air voids and the dispersion of $TiO_2$ in that these voids could easily adsorbed NOx gas with the aid of large surface area.

The Suggestion for Classification of Biotope Type for Nationwide Application (전국적 적용을 위한 비오톱유형분류 제안)

  • Choi, Il-Ki;Oh, Choong-Hyeon;Lee, Eun-Heui
    • Korean Journal of Environment and Ecology
    • /
    • v.22 no.6
    • /
    • pp.666-678
    • /
    • 2008
  • The needs for drawing up of biotope map is rapidly spreaded over each local government recently in Korea, according as enhancing of interest about biotope, which is recognized to practical instrument for concretely being able to considering natural environment and ecosystem on all sorts of development plan. However, there are not yet the standard suggestion on biotope types and classification systems and biotope classification criteria. Therefore, each other methodologies are applied to each of local autonomies. First, under such critical mind the biotope types and classification systems were drafted by a review on biotope types, biotope classification systems, and biotope classification criteria of the preceded case studies until now at the inside and outside of the country. And then the purpose of this study is to derive biotope types and biotope classification systems applicable to the whole Korean region through continual feed back such as field surveys in selected representative areas and consultations. As a result of reviewing the case examples, first, the biotope classification systems were mixed two steps system with three steps system and those were composed mostly of the structure of two steps: large and small. Second, land-use, soil pavement ratio, green cover ratio, and vegetation usually were applied to the biotope classification criteria. This study suggests that the biotope classification system is consisted of four steps system: large(biotope class), medium(biotope group), small(biotope type) and detail(sub-biotope type), and the biotope types are classified into 13 types of large step, 45 types of medium step and 127 types of small step. However, this study suggests that the new biotope types on small step or detail step should be continually supplemented with the foundation of classification system proposed in this study because the biotope type classification should consider regional characteristics.

Examination of Color Difference in Elastic Pavement that uses EPDM Chip using Ultraviolet Ray Accelerated Weathering Test (자외선 촉진 내후성 시험에 의한 EPDM Chip을 사용한 탄성포장의 색차분석)

  • Hong, Chang Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.91-98
    • /
    • 2011
  • Recently, the usage of elastic paving using EPDM Chip instead of pedestrian sidewalk blocks or permeable concrete used mostly for pedestrian walk, trails and in parks has been increassed as it can absorb impact during walking and produce wide range of colors and designs. However, the properties of EPDM Chip including elasticity and durability are decreased when exposed to ultraviolet ray and scenic paving functions through various colors are lowered due to the yellowing phenomenon. In this study, ultraviolet ray accelerated weathering test has been conducted to analyze the color changes in EPDM Chip and polyurethane resin, which are the main ingredients of elastic paving, when exposed to ultraviolet ray. The color differences are quantitatively analyzed through the color value coordination of the colored space by using the color difference scheme. The experimental results show that the color changes in BL polyurethane resin which is used most frequently at present was larger than that of EPDM Chip. Moreover, the total color difference, ${\Delta}E$, of BC polyurethane resin are 3.162 on the $14^{th}$ day of commencement of acceleration, which is 6 times greater color change resistance against ultraviolet ray than that of BL polyurethane resin with total color difference of 20.639. Therefore, the usage of BC polyurethane resin, which is manufactured to have chain-type molecular structure by using the isocyanate as the HMDI at the time of producing polymer, as binder in elastic paving with EPDM Chip is found to be a highly efficient method of restraining the color changes due to the ultraviolet ray.

Evaluation on Bending Moment of Bridge Approach Slabs under Vehicle Load Considering Soil Settlement (지반침하를 고려한 교량 접속판의 차량하중에 의한 휨모멘트 평가)

  • Back, Sung-Yong;Kim, Jung-Gang;Cho, Baik-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5939-5946
    • /
    • 2013
  • The bridge approach slabs (BAS) to provide a transitional roadway between a roadway pavement and a bridge structure have not performed adequately due to various factors. The current Korean Roadway Design Guidelines treat the BAS as a simply supported beam with 70% of the span length and do not consider settlement and void development underneath the slab. To investigate the effect of soil settlements on the bending moment of BAS, a beam on elastic support (BAS-ES) was used in the present study. The parameters used in this study were span length, washout length, washout location, and soil modulus. It was shown from the parametric study that washout regions closer to the midspan exhibit maximum moment in the slab. Since voids under the BAS have typically been observed to be closer to bridge abutments, the springs from the abutment were removed to simulate settlement and void development in the model. The design moments based on AASHTO LRFD Bridge Design Specifications were compared to those of Korean Standard Specifications for Highway Bridge and Design Trucks for Highway Bridges. Even if the design moment from BAS-ES was used to incorporate the effect of the potential washout, significant savings could still be achieved compared to the current BAS design.

Evaluation of Deicing Performance and Effects of Deicers of the Winter Season (동절기의 융빙제들의 융빙 성능 및 영향 평가)

  • Doh, Young-Soo;Lee, Byeong-Duck;Choi, Kwang-Soo;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.149-158
    • /
    • 2008
  • This study was estimated on performance of deicers, corrosion inhibitors and low corrodible deicer used for removal of snow or ice on the road and on influence on structure. The weight loss rate after freezing and thawing of low corrodible deicer is lower than one of deicer, corrosion inhibitors and these combination. Relative dynamic elastic modulus of all except water, low corrodible deicer and NaCl+JF-1004 was radically reduced after freezing and thawing 150 cycles. And concretes after freezing and thawing were showed severe surface damage. It was found that individual use of low corrodible deicer and corrosion inhibitors had a problem of field application because of lack of early ice melting effect and considerably low durability. Products combined with NaCl was showed rapid weight loss by metal corrosion. Therefore, It will need to circumspectly select combination of deicers having low effect on concrete pavement and bridge if possible.

  • PDF

Study of Polymer Rapid Setting Cement Concrete Using Electric Arc Furnace Oxidizing Slag Aggregate (전기로(電氣爐) 산화(酸化)슬래그 잔골재를 이용한 폴리머 속경성(速硬性) 시멘트 콘크리트 기초물성(基礎物性) 연구(硏究))

  • Jung, Won-Kyong;Gill, Yong-Soo;Kang, Seung-Hee
    • Resources Recycling
    • /
    • v.21 no.1
    • /
    • pp.30-40
    • /
    • 2012
  • Electric arc furnace slag is made in ironworks during steel refining, it is been increasing chemical and physical resistibility using ageing method of unstable state of melting steel slag for using concrete's fine aggregates. Which is been changing stable molecular structure of aggregates, it restrains moving of ion and molecule. In Korea, KS F 4571 has been prepared for using the electric arc furnace oxidizing slag to concrete aggregates(EFS). In this study, Electric arc furnace oxidizing slag is used in the PRCC(Polymer Rapid setting Cement Concrete) which is applied a bridge pavement of rehabilitation, largely. The results showed that the increment of compressive strength development by 10- 20%. The flexural strength of EFS-Con increased greatly as the electric arc furnace oxidizing slag changed. The compressive strength and flexural strength developed enough for opening the overlayed EFS-Con to the traffic after 4 hours of EFS-Con placement. The permeability of EFS-Con was evaluated as negligible due to its very low charge passed. Thus, EFS-Con could be used at repairing or overlaying the concrete at fast-track job sites.

Research on Design Capacity Evaluation of Low Impact Development according to Design Criteria (저영향개발 시설 설계 기준에 따른 용량 평가 방법 연구)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.59-67
    • /
    • 2022
  • The interest in LID facilities is increasing worldwide for recovery of natural water cycle system to destroy by urbanization. However, problems are raised when installation of LID because comprehensive analysis about design capacity adequacy of LID facilities was not conducted completely. In this research, removal efficiency and design volume adequacy of LID facilities were analyzed based on rainfall monitoring data in four LID facilities(Vegetated Swale, Vegetative Filter Strip, Bio-Retention and Permeable Pavement). As a result, group of LID facility designed on WQV was shown higher flow(37%) and pollutants(TSS, BOD, TN and TP) removal efficiencies(20 ~ 37%) than group of LID facility designed on WQF. SA/CA graph was drawn for evaluation of design volume adequacy based on rainfall monitoring data. In this SA/CA graph, coefficient of determination show over 0.5 in all parameter, especially, Flow and TP were show over 0.95. And, 'SA/CA & L/CA' graph considering difference of structure mechanism in LID facility suggested in this research was confirmed that improved coefficient of determination in flow, TSS and TP than SA/CA graph. According to this research results, feasibility of applying 'SA/CA & L/CA' graph for evaluation of design volume adequacy in LID facility, and it is necessary to follow up research for generalization and normalization.

Development and Application of an Evaluation Model for Biotope Appraisal as Related to Nature Experiences and Recreation (비오톱의 자연체험 및 휴양가치 평가모형 개발과 적용)

  • Cho, Hyun-Ju;Lee, Hyun-Taek;SaGong, Jung-Hee;Ra, Jung-Hwa
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.4
    • /
    • pp.11-24
    • /
    • 2010
  • The main focus of this research is the establishment of a systemic evaluation model based on objective evaluation indices, which are drawn to assess the experiencing of nature and recreational value at the level of the district unit. First of all, as a result of a literature review, a total of 10 indices can be drawn including vegetation structure, pavement rate, and hemeroby to evaluate an assessment of natural experiences and recreational value. Also, as a result of expert survey analysis, all evaluation index items were above 4.4, which is a high importance average. Hemeroby and unique landscape factor items in particular were above 5.8, which is very high. In addition, as a result of implementing a factor analysis to classify evaluation indices according to characteristics, three factors arise: 'landscape structure and quality of natural experience', 'typical availability', and 'quality of aesthetic and visual sense.' Based on the above survey analysis results, the 'quality of aesthetic and visual sense' was the highest, at 3.510. The classification 'landscape structure and quality of natural experience' was the lowest, at 3.035. A systemic value evaluation model was established by comprehensively analyzing these results. To verify the validity of the evaluation model drawn, real sites are selected and applied. First of all, as a result of a biotope types classification of sites, biotope type groups are classified into a total of 13 including the stream biotope while its subordinate biotope types are classified into a total of 61 groups. Lastly, as a result of biotope value evaluation, which was a previously established evaluation model, there are a total of 16 types including vegetation-abundant natural rivers and small-scale woodlands near forests in grade I. There are 9 types in grade II, 8 in grade III, 8 in grade IV, 19 in the least-valuable grade V.

Ecological Renewal Plan of Urban Parks for the Revitalization of Urban Green Axis in Gangdong-Gu (강동구 도시 녹지축 기능 활성화를 위한 도시공원의 생태적 리뉴얼 방안 연구)

  • Park, Jeong-Ah;Han, Bong-Ho;Kwak, Jeong-In
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.12-27
    • /
    • 2023
  • In this study, among the construction-type parks in Gangdong-gu, targeting parks with high environmental and ecological value located on the urban green axis, a plan was prepared for the ecological renewal of urban parks, and a design that applied to them was proposed. The renewal target site was selected by analyzing the general condition of Gangdong-gu and urban parks, the land use and green area ratio, park green area, and the green axis of Gangdong-gu. Gangdong-gu has 54 parks, including 2 neighborhood parks and 52 children's parks. In the first stage of the current status review, 17 parks were extracted through locational value analysis, such as location and adjacency to the natural axis and green axis. In the second stage, eight parks were selected among the first-stage extraction parks based on the ratio of green spaces and open spaces within each park service area. In the third stage, two of the second stage extraction parks were selected based on whether the legal standard of the park area was met, and in the fourth stage, one of the third stage extraction parks was selected through an aging survey of the park. As for the urban ecological status of the renewal target site, the status of land use in the aspect of entropy reduction, the status of soil cover in the aspect of water circulation, and the status of planting structure in the aspect of biodiversity were investigated. As for the status of the three renewal sites, the green area was insufficient at 18.3-45.3%, and the facility area was 54.7%-81.7%, which was judged to have low urban temperature reduction effects. The impervious pavement area accounted for 34.5% to 48.9% of the park area, accounting for most of the facility area, and it was judged that the water circulation function was insufficient. The planting structure consisted of a single layer and a double layer structure, and although the tree layer was good, the lower vegetation was poor, and there was no planting site of edible plants or large hardwood trees, so the biodiversity was low. After the ecological renewal design of Seonrin Children's Park, Dangmal Children's Park, and Saemmul Children's Park, which were selected as the renewal targets in this study, the ecological area ratio of each park increased by 1.4 to 3 times than before the renewal. If the urban parks located on the urban green axis are examined from the perspective of the urban ecosystem and renewed ecologically, it is judged that the expected effect will be high in reducing entropy, improving water circulation, and laying the foundation for biodiversity in terms of the urban ecosystem.