• Title/Summary/Keyword: patients

Search Result 62,819, Processing Time 0.092 seconds

A Study Analyzing Nursing Diagnoses and Nursing Interventions used in a Demonstration Home Care Project (가정간호 시범사업 간호진단 및 간호중재 분석 연구)

  • Suh, Mi-Hae;Lee, Hae-Won;Chun, Choon-Young
    • The Korean Nurse
    • /
    • v.34 no.5
    • /
    • pp.52-67
    • /
    • 1996
  • As home care in developing and becoming part of the health care delivery system in Korea, it is necessary to examine the use of nursing diagnoses and related nursing interventions with a view to increasing the standardization of nursing recording. This study was done to examine the nursing diagnosis and related nursing interventions used in home care. Data were collected using a chart review of the nursing notes written for the home care given to 38 patients who had pulmonary diseases or traumatic brain or spinal cord injuries and who had received home care as part of a demonstration home care project in a college of Nursing in Seoul. Early on in the project discussions as to format and use to nursing diagnosis was done and a tool was developed based on Gordon's eleven functional catergories with the addition of categories to cover family and environment. This tool was used in the data collection. Data included nursing diagnosis, etiologies and interventions. Real numbers and percentages were used in the analysis. The results show that the most frequently used diagnoses were in the category of physical function (75.6%), followed by the category of emotional and social function (21.8%). The least frequently used category was the one for family and environment (2.6%). The order of the frequency of recorded nursing interventions was the same, 82.3% for physical function, 16.2% of emotional and social function and 1.5% for family and environment. Under the category of physical functioning the most frequently used nursing diagnoses were related to mobility (62.2%), nutrition (23.6%) and elimination (11.9%). The frequencies of nursing interventions for these three diagnostic categories were 69.8%, 16.0% and 10.8% respectively. For emotional and social functioning, the most frequently used diagnoses were for cognition-perception (37.1%), self-perception (30.6%) and perception of health (23.7%). The ordering of the frequency of nursing interventions varied slightly. The most frequently used interventions were for the category of self-perception (31.7%) followed by cognition-perception (24.1%) and perception of health (22.9%). Looking at individual diagnoses, it was found that within the categroy of physical functioning, the most frequently used diagnosis was "impaired physical mobility" (29.5%) and this diagnosis involved 43.9% of the interventions. This was followed by "ineffective breathing pattern" (19.4%) with 17.7% of interventions, and "alteration in nutrition, less than body requirements" (11.2%) with 8.1% of the interventions. For the emotional social category, noncompliance was the most frequently used nursing diagnosis (18.2%) with 19.2% of the interventions. This was followed by "anxiety" (13.4%) with 13.6% of the interventions and by "knowledge deficit" (13.4%) but with only 5.5% of the interventions. The other diagnoses and interventions did not follow this pattern of frequency. Although there were a large number of diagnostic and intervention events, the number of actual diagnoses and interventions used were relatively small ranging from six interventions for "knowledge deficit" to 40 interventions for "imparied physical mobility". From this it can be concluded that the results of this study could be used as basic data for the development of standardized charts with respect to nursing diagnosis and interventions for clients with pulmonary disease and clients with traumatic brain or spinal cord injuries. Interventions that were direct care activities (1178) were much more frequent that education (430), and assessment and observation (148). There were also few diagnoses or interventions related to the family and the environment. This suggests two areas that need to be developed in home care and that need to be considered in the development of standardized records for use in home care.

  • PDF

Reproductive Factor and Food Intake Pattern Influencing on the Breast Cancer Risk in Daegu${\cdot}$Gyungbuk Area, Korea (대구${\cdot}$경북지역 유방암 위험에 영향 미치는 생식적 요인 및 식품섭취 패턴)

  • Lee, Eun-Ju;Suh, Su-Won;Lee, Won-Kee;Lee, Hye-Sung
    • Journal of Nutrition and Health
    • /
    • v.40 no.4
    • /
    • pp.334-346
    • /
    • 2007
  • The present study examined the reproductive factors and food intake pattern which influence on the breast cancer risk in Daegu${\cdot}$Gyungbuk area. The case subjects were 103 patients newly diagnosed as breast cancer at Kyungpook National University Hospital. The control subjects were 159 healthy women selected by frequency matching of age and menopausal status in the same community. The survey was conducted by individual interviews using questionnaires which include general and reproductive characteristics, dietary habits, and food frequency. The odds ratios were calculated by using unconditional logistic regression after adjusting for confounding variables. The mean age of the subjects was 50 yrs, and mean body mass index was significantly high in the patient group than in the control. The patient group had a significantly higher familial history of breast cancer and a significantly shorter breast-feeding period compared to the control group. It has been found no significant relationship between extrinsic hormone use such as oral contraceptives or estrogen replacement therapy and breast cancer risk. In regard of food habits, a high preference for the cooking method of steaming rather than frying, panbroiling or roasting was significantly associated with lower relative risk of breast cancer. The higher intake frequencies of fruits for all subjects, and seaweeds only for postmenopausal subjects were related with a significantly lower relative risk of breast cancer. The results of the study suggest that the possible risk factors for the breast cancer occurrence include high BMI, family history, less breast feeding experience, preference for the cooking method of frying, and less consumption of fruits and seaweeds. This study provides an useful data for nutrition education to prevent breast cancer for the residents in Daegu${\cdot}$Gyungbuk area.

Species of Bacteria and Antimicrobial Susceptibility Isolated from Clinical Specimens in Jeon Buk Area (전북지역 임상가검물에서 분리된 세균의 종류와 항생제 감수성)

  • 황구연
    • Biomedical Science Letters
    • /
    • v.3 no.1
    • /
    • pp.55-67
    • /
    • 1997
  • Considering many problems caused by the abuse of antibiotics recently, the appearance of antibiotic resistance bacteria is believed to help the cure of patients greatly. From Jan. 1st, 1996 to Dec. 31, 1996, 6135 strains were examined after being asked of and seperated from the clinical pathology departments of general hospitals, and the isolation frequency of identified bacteria and the susceptibility of antibiotics showed the following result. 1. The isolation frequency of strains was Escherichia coli, 1134 strains (18.4%), Pseudomonas aeruginosa, 856 strains (13.9%), coagulase negative Staphylococcus, 793 strains (12.89%), Staphylococcus aureus, 555 strains (9.02%), B. cepacia, 421 strains (6.84%), Enterobacter cloacae, 366 strains (5.95%), Enterobacter faecalis (4.86%), and Klebsiella pneumonia, 220 strains (3.85%). 2. The isolation rate of specimen was urine, 1, 969 strains, wound 1, 104 strains, sputum 701 strains, blood 643 strains, vaginal swab, 342 strains, and eye discharge, 192 strains, 40% of urine strains were E. coli 18% of wound strains were B. cepacia, 43.7% of sputum were P. aeruginosa, and in blood strains there were Enterobacter cloacae (25.8%), coagulase negative Staphylococcus (19.6%), and P. aeruginosa (8.7%). 3. The result of antibiotics susceptibility showed that, among gram negative bacilli, P. aeruginoas had resistance in almost all antibiotics except ceftazidme imipenem. But B. cepacia, the same glucose non-fermentation gram negative bacilli had more than 90% of sensitivity in aztreonam, ceftazidime, ciproflxacin, piperacillin, trimethoprim/sulfa and had resistance in the others. Enterococcus faecalis showed more than 85% of sensitivity in penicillin-G, ampicillin, ciprofloxacin. 4. In the case of specimen antibiotics susceptibility, Enterobacter cloacae was lower in specimen isolated from blood than in those isolated from others and p. aeruginosa was low in specimen isolated from urine, which showed that there was difference in specimen antibiotics susceptibility. The result of this study shows that there happen many resisitances in antibiotics used frequently and some countermeasure is necessary because many bacteria began to show new resistance. Also it is desirable that the choice of antibiotics for infection diagnosis and its cure should be made after the inspection of antibiotics.

  • PDF

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Comparison of Retinal Ganglion Cell Responses to Different Voltage Stimulation Parameters in Normal and rd1 Mouse Retina (정상망막과 변성망막에서 전압자극 파라미터 변화에 따른 망막신경절세포의 반응 비교)

  • Ye, Jang-Hee;Ryu, Sang-Baek;Kim, Kyung-Hwan;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.209-217
    • /
    • 2010
  • Retinal prostheses are being developed to restore vision for the blind with retinal diseases such as retinitis pigmentosa (RP) or age-related macular degeneration (AMD). Since retinal prostheses depend upon electrical stimulation to control neural activity, optimal stimulation parameters for successful encoding of visual information are one of the most important requirements to enable visual perception. Therefore, in this paper, we focused on retinal ganglion cell (RGC) responses to different voltage stimulation parameters and compared threshold charge densities in normal and rd1 mice. For this purpose, we used in vitro preparation for the retina of normal and rd1 mice on micro-electrode arrays. When the neural network of rd1 mouse retinas is stimulated with voltage-controlled pulses, RGCs in degenerated retina also respond to voltage amplitude or voltage duration modulation as well in wild-type RGCs. But the temporal pattern of RGCs response is very different; in wild-type RGCs, single peak within 100 ms appears while in RGCs in degenerated retina multiple peaks (~4 peaks) with ~10 Hz rhythm within 400 ms appear. The thresholds for electrical activation of RGCs are overall more elevated in rd1 mouse retinas compared to wild-type mouse retinas: The thresholds for activation of RGCs in rd1 mouse retinas were on average two times higher ($70.50{\sim}99.87\;{\mu}C/cm^2$ vs. $37.23{\sim}61.65\;{\mu}C/cm^2$) in the experiment of voltage amplitude modulation and five times higher ($120.5{\sim}170.6\;{\mu}C/cm^2$ vs. $22.69{\sim}37.57\;{\mu}C/cm^2$) in the experiment of voltage duration modulation than those in wild-type mouse retinas. This is compatible with the findings from human studies that the currents required for evoking visual percepts in RP patients is much higher than those needed in healthy individuals. These results will be used as a guideline for optimal stimulation parameters for upcoming Korean-type retinal prosthesis.

Ferucarbotran-Enhanced Hepatic MRI at 3T Unit: Quantitative and Qualitative Comparison of Fast Breath-hold Imaging Sequences (간의 3T 자기공명영상에서 초상자성산화철 조영증강 급속호흡정지영상기법들간의 양적 및 질적 비교평가)

  • Cho, Kyung-Eun;Yu, Jeong-Sik;Chung, Jae-Joon;Kim, Joo-Hee;Kim, Ki-Whang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.31-40
    • /
    • 2010
  • Purpose : To compare the relative values of various fast breath-hold imaging sequences for superparamagnetic iron-oxide (SPIO)-enhanced hepatic MRI for the assessment of solid focal lesions with a 3T MRI unit. Materials and Methods : 102 consecutive patients with one or more solid malignant hepatic lesions were evaluated by spoiled gradient echo (GRE) sequences with three different echo times (2.4 msec [GRE_2.4], 5.8 msec [GRE_5.8], and 10 msec [GRE_10]) for $T2^*$-weighted imaging in addition to T2-weighted turbo spin echo (TSE) sequence following intravenous SPIO injection. Image qualities of the hepatic contour, vascular landmarks and artifacts were rated by two independent readers using a four-point scale. For quantitative analysis, contrast-to-noise ratio (CNR) was measured in 170 solid focal lesions larger than 1 cm (107 hepatocellular carcinomas, nine cholangiocarcinomas and 54 metastases). Results : GRE_5.8 showed the highest mean points for hepatic contour, vascular anatomy and imaging artifact presence among all of the subjected sequences (p<0.001) and was comparable (p=0.414) with GRE_10 with regard to lesion conspicuity. The mean CNRs were significantly higher (p<0.001) in the following order: GRE_10 ($24.4{\pm}14.5$), GRE_5.8 ($14.8{\pm}9.4$), TSE ($9.7{\pm}6.3$), and GRE_2.4 ($7.9{\pm}6.4$). The mean CNRs of CCCs and metastases were higher than those of HCCs for all imaging sequences (p<0.05). Conclusion : Regarding overall performances, GRE using a moderate echo time of 5.8 msec can provide the most reliable data among the various fast breath-hold SPIO-enhanced hepatic MRI sequences at 3T unit despite the lower CNR of GRE_5.8 compared to that of GRE_10.

Assessment of Carotid Geometry by Using the Contrast-enhanced MR Angiography (조영증강 MR 혈관 조영술을 이용한 경동맥 기하학의 평가)

  • Lee, Chung-Min;Ryu, Chang-Woo;Kim, Keun-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.47-55
    • /
    • 2010
  • Purpose : To evaluate the geometry of carotid artery by assessing the images of contrast-enhanced MR angiography (CE-MRA) and interrelationships between the geometry of carotid artery and clinical factors. Materials and Methods : 216 consecutive patients who performed supraaortic CE-MRA with fast spoiled gradient-echo imaging were included. Their medical records were reviewed for variable information including risk factors predictive of generalized atherosclerotic disease (age, hypertension (HTN), diabetes mellitus, hyperlipidema, and smoking), sex, body weight, height, and body mass index (BMI). We reviewed the CE-MRA with carotid origin (3 types), carotid artery tortuosity, angle of internal carotid artery bifurcation, the type of aortic arch branching, and the presence of the coiling of carotid artery. Results : Multinomial logistic regression analysis showed that significantly contributed clinical backgrounds for carotid origin were the age and the BMI. With an increase of age at 1, the probability that the type of carotid origin become from type 1 to type 2 was 0.9 times (p=0.004) in right carotid artery (RCA), 0.9 times (p = 0.031) in left carotid artery (LCA), 0.9 times that are likely to be type3 from type 2 (p<0.001) in RCA and 0.9 times in LCA (p=0.009). Increase in BMI at 1 increased odds of becoming type 2 as 1.1 times (p = 0.067) in RCA, 1.1 times (p=0.009) in LCA and increased chance of becoming type 3 as 1.2 times (p = 0.001) in RCA, 1.2 times (p=0.003) in LCA. Mean value of right and left carotid tortuosity were $240.9{\pm}69.0^{\circ}$and $154.4{\pm}55.0^{\circ}$, respectively. Conclusion : The BMI, age, sex and presence of HTN affects the geometry of carotid arteries, the site of origin and tortuosity of carotid artery specifically.

Correlation of the Speed of Enhancement of Hepatic Hemangiomas with Intravoxel Incoherent Motion MR Imaging (간혈관종의 조영증강속도와 복셀내비결집운동 MR영상과의 상관관계)

  • Yang, Dal Mo;Jahng, Geon-Ho;Kim, Hyun Cheol;Kim, Sang Won;Kim, Hyug-Gi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.208-218
    • /
    • 2014
  • Purpose : To evaluate the relationship between the speed of enhancement of hepatic hemangiomas on gadolinium-enhanced MRI and ADC values by using various parameters, including the D, f, $D^*$ and $ADC_{fit}$ on intravoxel incoherent motion (IVIM) MR Imaging. Materials and Methods: The institutional review board approved this retrospective study. A total of 47 hepatic hemangiomas from 39 patients were included (20 men and 19 women). The hemangiomas were classified into three types according to the enhancement speed of the hepatic hemangiomas on gadolinium-enhanced dynamic T1-weighted images: rapid (Type A), intermediate (Type B), and slow (Type C) enhancement. The D, f, $D^*$ and $ADC_{fit}$ values were calculated using IVIM MR imaging. The diffusion/perfusion parameters and ADC values were compared among the three types of hemangiomas. Results: Both the $ADC_{fit}$ and D values of type C were significantly lower than those of type A (P = 0.0022, P = 0.0085). However, for the f and $D^*$, there were no significant differences among the three types. On DWI with all b values (50, 200, 500 and $800sec/mm^2$), the ADC values of type C were significantly lower than those of the type A (P < 0.012). For b values with $800sec/mm^2$, the $ADC_{800}$ values of the type C hemangiomas were significantly lower than those of type B (P = 0.0021). We found a negative correlation between hepatic hemangioma enhancement type and $ADC_{50}$ (${\rho}=-0.357$, P = 0.014), $ADC_{200}$ (${\rho}=-0.537$, P = 0.0001), $ADC_{500}$ (${\rho}=-0.614$, P = 0.0001), and $ADC_{800}$ (${\rho}=-0.607$, P = 0.0001). Therefore, four ADC values of $ADC_{50}$, $ADC_{200}$, $ADC_{500}$, and $ADC_{800}$ were decreased with decreasing enhancement speed. Conclusion: Hepatic hemangiomas had variable ADCs according to the type of enhancement, and the reduced ADCs in slowly enhancing hemangiomas may be related to the reduced pure molecular diffusion (D).

Investigation of Correlations of Double Inversion Recovery and MR Spectroscopy on Breast MR Imaging (유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구)

  • Ryu, Jung Kyu;Rhee, Sun Jung;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • Purpose : To evaluate the correlation of lesion-to-normal ratio (LNR) of signal intensity from double inversion recovery MR imaging and total choline-containing compound (tCho) resonance from single voxel MR spectroscopy in breast cancers. Materials and Methods: Between August 2008 and December 2009, 28 patients who were diagnosed as breast cancer and had undergone both double inversion recovery (DIR) MR imaging and MR spectroscopy (MRS) were included in this study. The signal intensities of the lesion (L) and ipsilateral normal breast tissue (N) were measured in region of interest of each breast cancer in DIR and contrast enhance MR image (CE-T1WI) to calculate the LNR value for each technique. MRS was performed using single-voxel MR spectroscopy. The height, width and area of tCho resonance were compared with each LNR of DIR and CE-T1WI. We used Pearson's correlation coefficient(r) for correlation analysis and the significance level was p=0.05. Results: There was no statistically significant correlation between LNR of CE-T1WI and height (r=-0.322, p=0.094), width (r=-0.233, p=0.232) and area (r=-0.309, p=0.109) of MRS tCho. There was no statistically significant correlation between LNR of DIR and height (r=0.067, p=0.735), width (r=-0.287, p=0.139) and area (r=0.012, p=0.953) of MRS tCho, either. The Pearson's correlation coefficient was 0.186 between LNRs of CET1WI and DIR (p=0.344). Conclusion: There was no statistically significant correlation between LNR of DIR and relative amount of tCho resonance of MRS.

Does the ADC Map have Additional Clinical Significance Compared to the DWI in the Brain Infarction? (뇌경색에서 확산강조영상과 비교하여 현성확산계수 지도의 부가적인 임상적 중요성이 있는가?)

  • Choi, Sunseob;Ha, Dong-Ho;Kang, Myong-Jin;Lee, Jin Hwa;Yoon, Seong Kuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.267-274
    • /
    • 2013
  • Purpose : To re-evaluate additional clinical significance of the apparent diffusion coefficient (ADC) map in the inference of infarction stage, authors studied the evolution patterns of the DWI and the ADC map of the brain infarction. Materials and Methods: In 127 patients with cerebral infarctions, including follow-up checks, 199 studies were performed. They were classified as hourly (117 studies)-, daily (108 studies)-, weekly (62 studies)-based groups. The signal intensity (SI) was measured at the core of the infarction and contralateral area with ROI of 0.3 $cm^2$ or more on the images of the DWI and the ADC map, and calculated the ratios of SI and ADC value of the infarction area / contralateral normal area, and compared the patterns of the change according to the evolution. Results: Infarction was detected as early as 1 hour after the attack, and the ratio of SI in the DWI became over than 2 after 12 hours, which showed a plateau until the 6th day. Thereafter, it decreased slowly to 1 on the 30th day, and changed to lower SI than the surrounding brain. The ratio in the ADC map became 0.46 in 24 hours after the attack, and increased slowly to 1 in the 15th day. Thereafter, it became a higher value than the surrounding brain. Overall, the ratio in the ADC map changed earlier than in the DWI, and the ratio curves showed inverse pattern each other according to the evolution of the infarction. Conclusion: The evolution patterns of infarction on the ADC map showed an inverse curve of DWI curve, which means that the ADC value is accurately predictable from DWI, and the ADC map joined with the DWI seems helpful in the determination of subacute infarction between 15 to 30 days.