• 제목/요약/키워드: patient-specific

Search Result 1,656, Processing Time 0.037 seconds

Hemolytic-uremic Syndyome Associated with Bloody Diarrhea (혈변을 동반한 용혈성 요독 증후군 5례)

  • Kim Jung-Sim;Park Eun-Jung;Chung So-Hee;Ko See-Hwan;Uhm Mee-Ryung;Park Moon-Su;Lee Heung-Jea;Jin Dong-Kyu
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.170-175
    • /
    • 1997
  • Purpose : Hemolytic uremic syndrome(HUS), known as a most common cause of childhood renal failure in western countries, has been a relatively rare disease in Korea. Although the reported cases were not related to any specific cause in Korea, there was an outbreak of HUS with bloody diarrhea in Japan last year. We report here that we experienced the several typical HUS last year. Patients : From Jan.1996 to Dec. 1996, five patients were diagnosed as HUS at Samsung Seoul Medical Center, Dept. Pediatrics. Results : 1) The age of onset was below 3 years in 3 cases and above 9 years in 2 cases. 2) All the cases happened between summer and autumn. Three patients had domestic travel and 4 patients drank well or spring water before the symptoms. 3) The clinical manifestation was generalized edema, oliguria, anuria and hematuria. The bloody diarrhea were present in 5 cases and 1 patient had operation with the impression of appendicitis. 4) There was no bacteria which was isolated from the blood or stool samples. 5) Renal biopsies were performed in 2 cases, because of protracted clinical course. One showed microthrombotic angiopathy and the other cortical necrosis with necrotizing glomeruli. 6) Complete recovery was the outcome in 4 cases and one case progressed to chronic renal failure. Conclusion : In conclusion, typical HUS associated with bloody diarrhea, epidemic and good prognosis can be found in Korea and careful surveillance of the pre-clinical cases will be necessary.

  • PDF

The Effects of Diluted Fibrin Glue about Continuous Air Leakage after Lung Surgery (폐수술 후 지속적 공기누출에 희석한 Fibrin Glue의 효과)

  • Choi Chang-Woo;Lee Seong-Jin;Lee Chol-Sae;Lee Kihl-Rho;Lee Seock-Yeol
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.770-774
    • /
    • 2006
  • Background: Continuous air leakage through chest tube after lung surgery may increase pt's hospital stay and lead to many complications including empyema etc. Chemical pleurodesis has frequently been used for prevention of air leakage. Therefore, we performed chemical pleurodesis using diluted fibrin glue in patients with continuous air leak-age and observed the effects and efficiency of treatment. Material and Method: From September, 2001 to August, 2005, 16 patients whose continuous air leakage lasted more than 7 days underwent chemical pleurodesis with diluted fibrin glue. The effects of treatment, complications and recurrences were reviewed. Dissolved fibrinogen 1.0 g and aprotinin 500,000 KIU were mixed in a 50 cc syringe (Mixed solution A). And dissolved thrombin 5,000 IU and Calcium chloride 600 mg were mixed in a 50 cc syringe (Mixed solution B). Cefazolin 1.0 g was mixed in a 50 cc syringe (Mixed solution C). Rubber tube was inserted between the chest tube and the collecting bottle. An inserted rubber tube was positioned 60cm above the patient and forming a loop appearance was done. Mixed solutions A, B and C were injected into the highest rubber tube. Results: Continuous air leakages disappeared in all f6 patients at next day. Chest tubes were removed after 3 days in all patients. Complications were chest pain in 12 patients (75%), leukocytosis in 14 patients (88%), fever and chill in 14 patients (88%). All complications were transient and disappeared without specific treatment. Conclusion: Our findings demonstrated that diluted fibrin glue chemical pleurodesis was effective in patients with continuous air leakage lasting more than 7 days. Diluted fibrin glue chemical pleurodesis had good results with acceptable complications. long term follow-up is necessary to evaluate the accurate effects of treatment and recurrence in a large number of patients.

Temporal Variations of Cerebrovascular Diseases in a University Hospital (일개 대학병원을 대상으로 한 뇌혈관질환의 시간적 변동양상)

  • Lee, Mi-Yon;Lee, Sang-Bock;Lee, Jun-Hang;Lee, Sam-Yul;Lee, Tae-Soo;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.17-23
    • /
    • 2007
  • Background: Cerebrovascular diseases are known to show different patterns of incidence among regions and races. Therefore, it is very important to determine the incidence pattern of a specific area in order to diagnose, treat and prevent cerebrovascular diseases. The objective of the present study is to analyze quantitatively the incidence ratios of hemorrhagic and ischemic cerebrovascular diseases by season, by gender and by age. Methods: The subjects of this study were 1603 patients hospitalized for hemorrhagic or ischemic cerebrovascular diseases at the Department of Neurosurgery or the Department of Neurology of a University Hospital. Statistical analysis of data used Excel 2003 of Microsoft, and t-test was conducted using ORIGIN 6.0 of MICROCAL. Results: In the subjects, the incidence ratios of hemorrhagic and ischemic cerebrovascular diseases for four years, the period of this research, were 38.55% and 61.45%, respectively. The mean and standard deviation of age when hemorrhagic cerebrovascular diseases occurred were 58.20 and 12.60, respectively, and the percentages of subjects in their 40s, 50s, 60s and 70s were all around 20%. On the contrary, the mean and standard deviation of age when ischemic cerebrovascular diseases occurred were 65.01 and 13.59, respectively. The average age of patients with ischemic cerebrovascular diseases was older than that of patients with hemorrhagic brain diseases, and the percentages of those in their 60s, 70s and 80s were 15.53%, 37.06% and 27.72%, respectively. The season when hemorrhagic cerebrovascular diseases appeared most frequently was winter, which was followed by summer, spring and autumn. The season when hemorrhagic cerebrovascular diseases appeared most frequently was spring, which was followed by summer, winter and autumn. Conclusions: In this study, the incidence rates of hemorrhagic and ischemic cerebrovascular diseases were 38.55% and 61.45%, showing the rising percentage of ischemic cerebrovascular diseases. For making adequate prevention and disease control plans, it is considered necessary to make a long-term epidemiological investigation of cerebrovascular diseases.

  • PDF

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Perfusion Impairment in Infantile Autism on Brain SPECT Using Tc-99m ECD : Comparison with MR Findings (유아 자폐증 환아에서의 Tc-99m ECD를 이용한 뇌 단일 광전자 방출 전산화 단층 촬영술상의 관류 저하: 자기 공명 영상과의 비교 분석)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Yoon, Pyeong-Ho;Kim, Dong-Ik;Oh, Young-Taik;Lee, Sun-Ah;Lee, Ho-Bun;Shin, Yee-Jin;Lee, Byung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.320-329
    • /
    • 1997
  • Neuroanatomic substrate of autism has been the subjects of continuing investigation. Because previous studies had not demonstrated consistent and specific neuroimaging findings in autism and most studies comprised adults and school-aged children, we performed a retrospective review in search of common functional and anatomical abnormalities with brain SPECT using Tc-99m ECD and correlative MRI The patient population was composed of 18 children aged 28 to 89 months(mean age : 55 months) who met the diagnostic criteria of autism as defined in the DSM-IV and CARS. Brain SPECT was performed after intravenous injection of 185-370MBq of Tc-99m ECD using brain dedicated annular crystal gamma camera. MRI was performed in all patients including T1, T2 axial and T1 sagittal sequences. SPECT data were visually assessed. Thirteen patients had abnormal SPECT scan revealing focal areas of decreased perfusion. Decreased perfusion of cerebellar vermis(12/18), cerebellar hemisphere(11/18), thalami(13/18), basal ganglia(4/18), posterior parietal(7/18), and temporal(4/18) area were noted on brain SPECT. Whereas, only 3 patients had abnormal MR findings which were subtle volume loss of parieto-occipital white matter in 3 and mild thinning of posterior body of corpus callosum in 2 and slightly decreased volume of cerebellar vermis in 1. Comparison of the numbers of abnormal findings revealed that regional cerebral blood flow (rCBF) abnormalities seen on SPECT were more numerous than anatomical abnormalities seen on MRI. In conclusion, extensive perfusion impairment involving cerebellum, thalami and parietal lobe were found in this study. SPECT may be more sensitive in reflecting pathophysiology of autism than MRI. However, further studies are mandatory to determine the significance of thalamic and parietal perfusion impairment in autism.

  • PDF

Assessment of the Effect of a Public Health Clinics' Home-Based Terminal Cancer Patient Management in Collaboration with a Regional Cancer Center (경남 지역 암센터와 보건소 재가암환자 관리 서비스와의 연계 사업)

  • Song, Haa-Na;Kang, Myoung Hee;Lee, Gyeong Won;Kim, Hoon Gu;Lee, Won Sup;Kang, Jung Hun;Kang, Yoon Sik;Eun, Young
    • Journal of Hospice and Palliative Care
    • /
    • v.16 no.1
    • /
    • pp.10-19
    • /
    • 2013
  • Purpose: Home-based care providers were surveyed to assess the effect of collaborative service between Gyeongnam Regional Cancer Center (GRCC) and public health centers (PHCs) in Gyeongnam province. Methods: Twenty home-based care providers who had previously participated in the GRCC-PHC care project were recruited from nine PHCs and were surveyed using a questionnaire developed by specialists. Questions were rated using the 5-point Likert scale ranging from "strongly disagree (-2)" to "strongly agree (+2)" and each score was multiplied by the corresponding number of respondents (n=20) with the maximum score of 40. Results: Between January 2008 and December 2011, 73 patients were registered to the collaborative service: 72 by GRCC and one by PHC. Home-based care providers marked the highest score (23 points) to "The collaborative service contributed to patients and their family's psychological stability" and the lowest score (11 points) to "The collaborative service was generally helpful for home-based cancer management." For possible suggestions to improve the service, the highest score (35 points) was given to "Simplification of the hospitalization process" followed by "Substantial benefits for patients at their visit to the hospital" (34 points). Conclusion: The results revealed several limitations of the GRCC-PHC collaborative care service for terminal cancer patients. The service could be further improved by developing measures to address the limitations and a service model tailored to region-specific needs.

Novel Real Time PCR Method for Detection of Plasmodium vivax (새로운 Real Time PCR 방법을 통한 Malaria(Plasmodium vivax)의 검출)

  • Ki, Yeon-Ah;Kim, So-Youn
    • Microbiology and Biotechnology Letters
    • /
    • v.33 no.2
    • /
    • pp.148-153
    • /
    • 2005
  • Malaria is a re-emerging infectious disease that is spreading to areas where it had been eradicated, such as Eastern Europe and Central Asia. To avoid the mortality from malaria, early detection of the parasite is a very important issue. The peripheral blood smear has been the gold standard method for the diagnosis of malaria infection. Recently, several other methods have been introduced for quantitative detection of malaria parasites. Real time PCR that employs fluorescent labels to enable the continuous monitoring of PCR product formation throughout the reaction has recently been used to detect several human malaria parasites. 18S rRNA sequences from malaria parasites have been amplified using Taqman real time PCR assay. Here, a SYBR Green-based real time quantitative PCR assay for the detection of malaria parasite-especially, Plasmodium vivax - was applied for the evaluation of 26 blood samples from Korean malaria patients. Even though SYBR Green-based real time PCR is easier and cheaper than Taqman-based assay, SYBR Green-based assay cannot be used because 18S rRNA cannot be specifically amplified using 1 primer set. Therefore, we used DBP gene sequences from Plasmodium vivax, which is specific for the SYBR Green based assays. We amplified the DBP gene from the 26 blood samples of malaria patients using SYBR Green based assay and obtained the copy numbers of DBP genes for each sample. Also, we selected optimal reference gene between ACTB and B2M using real time assay to get the stable genes regardless of Malaria titer. Using selected ACTB reference genes, we successfully converted the copy numbers from samples into titer, ${\sharp}$ of parasites per microliter. Using the resultant titer from DBP based SYBER Green assay with ACTB reference gene, we compared the results from our study with the titer from Taqman-based assay. We found that our results showed identical tendency with the results of 18S rRNA Taqman assay, especially in lower titer range. Thus, our DBP gene-utilized real time assay can detect Plasmodium vivax in Korean patient group semi-quantitatively and easily.

Review of the Radiation Risk and Clinical Efficacy Associated with Computed Tomography Cancer Screening (암의 조기발견을 위한 CT촬영에서의 임상적 효능과 방사선위해에 대한 고찰)

  • Kim, Hyun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.214-227
    • /
    • 2013
  • Computed tomographic scan as a screening procedures in asymptomatic individuals has seen a steady increase with the introduction of multiple-raw detector CT scanners. This report provides a brief review of the current controversy surrounding CT cancer screening, with a focus on the radiation induced cancer risks and clinical efficacy. 1. A large study of patients at high risk of lung cancer(the National Lung Screening Trial[NLST]) showed that CT screening reduced cancer deaths by 20%(1.33% in those screened compared with 1.67% in those not screened). The rate of positive screening tests was 24.2% and 96.4% of the positive screening results in the low-dose CT group were false-positive. Radiation induced lung cancer risk was estimated the most important in screening population because ERR of radiation induced lung cancer does not show the decrease with increasing age and synergistic connection between smoking and radiation risk. Therefore, the radiation risk may be on the same order of magnitude as the benefit observed in the NLST. Optimal screening strategy remain uncertain, CT lung cancer screening is not yet ready for implementation. 2. Computed tomographic colonography is as good as colonoscopy for detecting colon cancer and is almost as good as colonoscopy for detecting advanced adenomas, but significantly less sensitive and specific for smaller lesions and disadvantageous for subsequent therapeutic optical colonoscopy if polyps are detected. The average effective dose from CT colonography was estimated 8-10 $mS{\nu}$, which could be a significant dose if administered routinely within the population over many years. CT colonography should a) achieve at least 90% sensitivity and specificity in the size category from 6 and 10 mm, b) offer non-cathartic bowl preparation and c) be optimized and standardized CT parameters if it is to be used for mass screening. 3. There is little evidence that demonstrates, for whole-body scanning, the benefit outweighs the detriment. This test found large portion of patient(86~90.8%) had at least one abnormal finding, whereas only 2% were estimated to have clinically significant disease. Annual scans from ages 45 to 75 years would accrue an estimated lifetime cancer mortality risk of 1.9%. There is no group within the medical community that recommends whole-body CT. No good studies indicate the accuracy of screening CT, at this time. The benefit/risk balance for any of the commonly suggested CT screening techniques has yet to be established. These areas need further research. Therefore wild screening should be avoided.

The Effectiveness of Spiral Computed Tomography as a Diagnostic Tool in Pulmonary Embolism(Comparison of Spiral CT with Ventilation-Perfusion Scan) (폐색전증 진단의 도구로서의 Spiral Computed Tomography의 유용성(폐환기관류주사와의 비교))

  • Koh, Jae-Hyun;Oh, Eun-Young;Park, Jung-Ho;Park, Sang-Joon;Yun, Jung-Hwan;Park, Jung-Woong;Suh, Gee-Young;Chung, Man-Pyo;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.564-573
    • /
    • 1999
  • Background: With variable symptoms and nonspecific radiographic appearances, pulmonary embolism (PE) is a frequent and often undiagnosed cause of mortality and morbidity. The Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) study suggested that the majority of patients undergoing ventilation-perfusion (V-Q) scan would require additional studies to establish or to exclude the diagnosis of PE. Pulmonary angiography has been regarded as gold standard for diagnosis of PE. However, it is an invasive procedure that may be associated with significant notable morbidity and mortality. Thus, availability of an accurate, noninvasive screening examination is highly desirable. Method: From October 1994 to February 1997, twenty patients (male 13, female 7, range 23-91 years, median 58 years) who were suspected as pulmonary embolism on the basis of clinical evidence and underwent the spiral volumetric computed tomography (spiral CT), were studied retrospectively to evaluate the effectiveness of spiral CT as a diagnostic tool in PE. Results: PE could be excluded with spiral CT in 4 patients ; diagnoses of these patients were lung cancer, pneumonia with lung abscess, bilateral pleural effusion due to congestive heart failure, nonspecific pulmonary abnormality retrospectively. One patient who disclosed high probability in V/Q scan, could be diagnosed as pneumonia with lung abscess and underlying emphysema with spiral CT. Among 4 patients who showed intermediate and low probability in V/Q scan, 3 patients could be confirmed as PE with spiral CT. Spiral CT was helpful in 3 patients, in whom V/Q scan could not be performed due to other reasons (e.g. night time, mechanical ventilation) to confirm the diagnosis of PE. Spiral CT could demonstrate embolus above lobar artery level in 11 patients, and up to segmental artery level in 5 patients. Conclusion: This study demonstrated that spiral CT could allow accurate demonstration of thrombotic clots in centrally localized embolism. Spiral CT could be effective, specific, noninvasive and useful diagnostic screening modality for the diagnosis of pulmonary embolism.

  • PDF

Hepatic Cirrhosis Secondary to chronic Hepatitis in an English Cocker Spaniel (ECS) Dog (잉글리쉬 코커스파니엘 견에서 발생한 만성 간염 및 간경화 증례)

  • Park Chul;Yoo Jong-Hyun;Jung Dong-In;Kim Ha-Jung;Kang Byeong-Teck;Lim Chae-Young;Yoon Hun-Young;Jeong Soon-Wuk;Sur Jung-Hyang;Park Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.72-76
    • /
    • 2006
  • A 1-year-old, female English cocker spaniel (ECS) dog was presented with 3-month history of vomiting and retaking of the vomitus, and chronic weight loss. The client had noticed mild abdominal distension 10 days before. The dog was diagnosed as chronic hepatitis with hepatic cirrhosis based on complete blood count (CBC), serum chemistry profiles, radiography, ascites assessment, bile acid evaluation, and liver biopsy through exploratory laparotomy and necropsy. CBC and serum chemistry profiles revealed mild anemia, slightly elevated hepatic enzymes (ALT and AST), increased creatinine kinase (CK), hyperammonemia, and hypoproteinemia with hypoalbuminemia. Ascites was transudate according to analysis of components. Bile acid assessment (fasting; $174.4{\mu}mol/L$ and postprandial; $198.4{\mu}mol/L$) showed strongly suspected hepatic insufficiency. On radiological findings, ascites was evident. Atrophied liver (especially left side lobes) and distended mesenteric vasculatures were observed by exploratory laparotomy. Histopathological examination of marginal lesion of left lateral lobe of liver by biopsy revealed the necrosis of hepatic cells, dilation of sinusoids, infiltration of neutrophils in sinusoids, and vacuolation of hepatic cytoplasm. The patient had been managed with careful low protein diet and specific supportive therapy (ursodeoxycholic acid, prednisolone, vitamine E, and interferon). Vomiting and ascites disappeared with medical management. The dog was monitored periodically by CBC, serum chemistry and radiographic examination. The dog survived more 18 months with medical therapy. After spontaneous death, necropsy and histopathologic examination were performed.