• 제목/요약/키워드: patient bed room

검색결과 47건 처리시간 0.025초

종합병원 다인병실의 치유환경 개선을 위한 건축 계획적 연구 (A Study on the Architectural Planning for Improvement of the Healing Environment in Multi-bed Room of General Hospitals)

  • 김용우;양내원
    • 한국실내디자인학회논문집
    • /
    • 제36호
    • /
    • pp.76-83
    • /
    • 2003
  • The purpose of this study is to know how to improve environment of multi-bed room by investigating and analysing factors influencing to patients. 1 measured stress and satisfaction degrees about patient room for 4ㆍ5ㆍ6ㆍ7 men of domestic general hospital wards. The results of research show that patients of 4 bed room appeared the fewest stress and highest satisfaction degree among patients of other room styles. The patients positioned between two beds can give us more stress and fewer satisfaction than others. These results have proven that 4 bed room patients are offering comfortable environment than any other room types as a healing environment. When patient room area are more than 7.3$M^2$ per 1 person, bed interval space is more than 120cm, there is curtain between bed, transit space such as a toilet were established in patient room, patients' satisfaction appeared high.

1인실과 다인실 입원 병상 이용에 관한 병상 선택 요인과 환자 만족도 분석 (Use of Single Bedrooms versus Multiple Bedrooms: Selection Factors and Comparison of Patient Satisfaction)

  • 이근찬
    • 한국병원경영학회지
    • /
    • 제26권3호
    • /
    • pp.68-83
    • /
    • 2021
  • Background: It is widely acknowledged that single bedrooms have many potential advantages compared to multiple bedrooms. However, Korea has a reimbursement system that patients have to pay the additional fee if they will use single bedroom or pay-bed (1-3 bedroom). There is little research on patients' bed selection and relationship between patient satisfaction and bed type in the Korean setting. Methods: Using the 2017 Korea Health Panel (KHP) Survey data, we modified bed type by two dichotomous variables: single bedroom vs. multiple bedroom (2+ bedrooms) and pay-bed (1-3 bedroom) vs. reimbursed bed (4+ bedroom). Multivariate logistic regression is performed to determine the factors affecting the patient's choice of room types. Multivariate regression analysis was conducted to examine how hospital room types are affecting patient satisfaction. Results: Single room and pay-bed (1-3 bedroom) use was influenced by patient age (19- years old), male, a person at work, hospitalizing in a clinic, and birth. After controlling variables of the behavioral model of medical utilization, the association between patient satisfaction and use of single bedroom & pay-bed (1-3 bedroom). Cause of hospitalization, major treatment, and recognition of unnecessary care are statistically significant variables on patient satisfaction. Conclusion: Although the single room is about the standard for newly built hospitals in western countries, it remains unclear that single room or pay-bed (1-3 bedroom) has positive effects on patient's outcomes and satisfaction. In this empirical study, the difference in patient satisfaction by bedroom type was not noticeable. In terms of bed management by hospital staff, securing patient credibility in hospital care is an important task. Patients' perception of whether medical staffs have encouraged unnecessary treatment or tests has a significant impact on patient's satisfaction.

중환자실 병상주변공간의 면적과 간격에 관한 연구 (A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit)

  • 이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

병원의 다인병실 환경개선에 관한 연구 (A Study on the Environmental Improvement of Multi-bed rooms in Hospital)

  • 유영민
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제11권1호
    • /
    • pp.7-14
    • /
    • 2005
  • The existing six-bed patient rooms, general type of multiple-bed rooms in Korea causes many problems for the amenity of patients. We should reconsider their inconvenience carefully and try to provide the right to keep their privacy and enjoy amenity. The number of patients of multi-bed rooms is very critical point to improve the environmental condition of the patient rooms. So This paper aims to provide the possibilities of four-bed rooms through the comparison and analysis of six and four-bed room for planning and design.

  • PDF

다인병실 입원환자의 성별에 따른 프라이버시 특성 연구 (A Study of Gender Differences in Inpatients' Privacy Concerns in Multi-bed Hospital Room)

  • 신은경;박수빈
    • 한국실내디자인학회논문집
    • /
    • 제27권1호
    • /
    • pp.80-87
    • /
    • 2018
  • This study aims to find gender differences in inpatients' privacy and stress concerns in multi-bed hospital room. In the literature review, we consider the characteristics of multi-bed hospital room and patients' privacy as a psychological environment factor. In the survey research, the questionnaires were used to understand the inpatients' general characteristics and privacy requirements. A total of 109 copies were analyzed through a cross-tabulations and T-test using the SPSS 18.0. Results and conclusions are as follows: (1) In the case of multi-bed room patients, there were some gender differences in privacy and stress, but the differences were limited. (2) There is a difference in the patient 's preference of the hospital room according to gender, and this is related to the privacy characteristic. (3) The social communication and strolling are commonly effective stress relief methods for both men and women, so space is needed to do this methods. The meaning of this study is to specify the privacy and stress of the inpatients in multi-bed patients' room.

창의 형태 및 차양 계획에 따른 다인 병실의 에너지소비량과 주광조도의 평가 및 분석 (Energy Consumptions and Daylight Illumination levels of a Multi-beded Patient Room according to the Window Shapes and Shading)

  • 최창대;권순정;김선숙
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제18권3호
    • /
    • pp.29-39
    • /
    • 2012
  • Window and shading designs have a great influence on energy consumption and daylighting in buildings. As far as energy is concerned, small window area is advantageous. But it is not good to the patient healing in hospital. So it is important to find out the optimum window shape which is favorable for both energy consumption and patient healing. In this study, annual energy consumption and daylight illumination levels were analyzed according to the window shapes and shading devices for a multi-beded patient room in hospitals. The simulations were conducted for 19 different cases by COMFEN 4.0 computer simulation program. The results of this paper are as follows. First, window to wall area ratio and shading devices have great influences on annual energy consumption. But it is a problem in that they decrease significantly daylight level in bed room. Second, considering the same energy consumption, reducing the width of window rather than the hight of window is desirable for the secure of daylight level. Third, increase of the number of horizontal shade is not desirable in south face of the building for the energy consumption and daylight level. Fourth, sun shade is not necessary in north face of the building for the energy consumption and daylight level.

2015년 메르스 사태 이후 신축된 종합병원 병동부의 공간구성 특징 및 입원실 세부시설기준에 관한 연구 (A Study of the Spatial Composition and the Facility Criteria of In-patient Rooms in General Hospitals after MERS 2015)

  • 이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권2호
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: This study is to address the spacial composition of a standard ward and bedroom size for sake of infection control and efficient medical service. Methods: Spacial composition of a standard ward has been proposed by comparative analysis of 5 big hospitals' wards. Bedroom sizes have been explored on the ground of Health care facility regulations from Korea, USA, Australia and Canada. Of course, Literature and field survey have been conducted in order to draw out various bedroom sizes. Results: 16 basic and some other additional spaces have been proposed for the composition of hospital standard ward. Area of Single bedroom is $11.6m^2$, and that of multi-beded room is $7.4m^2$. Bed to bed Clearance is 1.5m, spacing between bedsize and hard wall is 0.9m in 1~2 beded room, 0.75m in 4-beded room. Space clearance between Foot side of bed and curtain is proposed as 0.3m and additional 0.9m is necessary for the circulation. Implications: The result of this study can be applied to the new cons.

국가지정입원격리병상의 시설별 면적구성에 관한 연구 - 2016년 국가지정입원격리병상 확충사업대상을 중심으로 (A Study on the Area Composition Analysis of the National Designated Isolation Unit Wards(NDIUs) - Focused on the NDIU wards issued in 2016)

  • 윤형진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권2호
    • /
    • pp.73-82
    • /
    • 2017
  • Purpose: Since the facility guidelines for National Designated Isolation Unit wards(NDIUs) had been edited since 2016, all hospital who want to expand or install NDIU should adapt the new guidelines. Instead of providing area requirement, by the way, only essential or optional facility requirements are suggested except patient bedroom in the guidelines. So, as analyze area and area composition of the NDIUs, it could be expected that this study has a role as an area planing reference for not only NDIU but also another airborne infection isolation room. Methods: For the area analysis, 18 sample hospitals are selected among 2016 year applicants. All rooms in NDIUs are grouped as zones whether those are negative air pressurized or not and programed room or not. At the end, area of the zones are summarized and analysed a relationship between area increase and bed number by both correlation analysis and regression analysis. In addition, department usable and gross area per bed, N/G ratio, G/N ratio, and average area ratio of each zone is calculated. Results: First of all, rooms in none negative air pressurized zone of the NDIUs haven't shown a regular installation so that only those in negative air pressurized zone are targeted for the area analysis. Second of all, patient room unit(0.92) and support area(0.79), by correlation analysis, are correlated with total net area. Patient room unit(0.94) and total net area(0.79) are also shown a correlation with bed number. Department usable area($R^2=0.63$, y=36.278x + 102) and patient room unit area($R^2=0.89$, y= 27.993x - 0.8924) has a relationship with bed number by regression analysis. Average N/G is shown as 0.85 and G/N 1.36. Average area ratio of circulation, doffing area, patient room unit, and support area are 25.4%, 9.1%, 50.9%, and 14.6% in order. Implications: This study is a basic research for exploring the NDIUs guidelines to find resonable evidence to develop it for its practical use. Still, it is possibly expected that the guideline is to be developed by post occupancy evaluation in the area of where minimum requirement or facility grade needs to be defined, and by further studies with various perspectives.

응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발 (Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed)

  • 임우택;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

백선 환자가 사육하고 있는 애완동물 및 침실먼지에서 피부사상균의 분리 (Isolation of Dermatophytes from Domestic Animals and Bed Room Dust of Tinea Patients)

  • 방용준;김쌍용
    • 대한임상검사과학회지
    • /
    • 제38권2호
    • /
    • pp.94-98
    • /
    • 2006
  • The mattresses and dust in the bed rooms of nine dermatophytes infected patients and nine domestic animals were examined by the KOH method. Microsporum canis species and Trichophyton mentagrophytes were isolated from cats and rabbits, respectively. The sources of infection of three patients were the M. canis infected cats raised by them and the four other patient's sources of infection were not confirmed. The sites of infection of the nine patients were their heads and those of the domestic animals were their heads and bodies. M. canis species were isolated from the infection sites of three cats and specimens collected by hair brush from the nine domestic animals. T. mentagrophytes species were also isolated from the infection sites of two rabbits. The seven patients had mattresses and bed room dust contaminated with M. canis.

  • PDF