• Title/Summary/Keyword: passive safety systems

Search Result 108, Processing Time 0.027 seconds

Assessment and Improvement of the Horizontal In-Tube Condensation Heat Transfer Model in the MARS code (MARS 코드의 수평관내부 응축열전달 모델 평가 및 개선)

  • Lee, Hyun Jin;Ahn, Tae Hwan;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.56-68
    • /
    • 2016
  • Extensive researches have been carried out for enhancing the safety of nuclear power plants and, especially, the development of passive cooling systems, such as passive containment cooling system (PCCS) and passive residual heat removal system, is increasingly important, where condensation is a crucial heat transfer mechanism. Recently, Ahn & Yun et al. developed a horizontal in-tube condensation heat transfer model as one of the activities for the PCCS development. In this work, we implemented the Ahn & Yun 's condensation heat transfer model into the MARS code and assessed it using the PASCAL experimental data. Based on the results of the assessment, we identified the limitations of the Ahn & Yun 's model and suggested a modified Ahn & Yun 's model, and assessed the model using various experimental data.

NATURAL CIRCULATION ANALYSIS CONSIDERING VARIABLE FLUID PROPERTIES WITH THE CUPID CODE (CUPID 코드의 유체 물성치 변화를 고려한 자연대류 해석)

  • Lee, S.J.;Park, I.K.;Yoon, H.Y.;Kim, J.
    • Journal of computational fluids engineering
    • /
    • v.20 no.4
    • /
    • pp.14-20
    • /
    • 2015
  • Without electirc power to cool down the hot reactor core, passive systems utilizing natural circulation are becoming a big specialty of recent neculear systems after the severe accident in Fukusima. When we consider the natural circulation in a pool, thermal mixing phenomena may start from single phase circulation and can continue to two phase condition. Since the CUPID code, which has been developed for two-phase flow analysis, can deal with the phase transition phenomena, the CUPID would be pertinent to natural convection problems in single- and two-phase conditions. Thus, the CUPID should be validated against single- and two-phase natural circulation phenomena. For the first step of the validation process, this study is focused on the validation of single-phase natural circulation. Moreover, the CUPID code solves the fluid properties by the relationship to pressure and temperature from the steam table considering non-condensable gas effects, so that the effects from variable properties are included. Simple square thermal cavity problems are tested for laminar and turbulent conditions against numerical and experimental data. Throughout the investigation, it is found that the variable properties can affect the flow field in laminar condition, but the effect becomes weak in turbulence condition, and the CUPID code implementing steam table is capable of analyzing single phase natural circualtion phenomena.

A study on driver experience to railway crossings in driving simulator (차량 시뮬레이터를 이용한 철도건널목 운전행태에 관한 연구)

  • Kim, Inhi;Lee, Seonha
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.2
    • /
    • pp.57-67
    • /
    • 2014
  • In the last decade, various situations were simulated through virtual environment due to rapid improvement of computer capability and technology. Transportation engineering also has adopted the virtual environment facility in order to identify drivers behaviour under various circumstances. This study aims to evaluate driver reactions to the introduction of new ITS interventions at railway crossings (RLX) in driving simulator. Three ITS safety devices were used to figure out how drivers reacted to them. In addition, a survey was conducted to find participants' work load and acceptance of the technology. The ultimate purpose of this paper is to evaluate ITS safety devices in various aspects. Each participant made 3 runs (2 baselines, 1 ITS randomly) for approximately 20 minutes each. The participants answered that current railway crossings did not look safe prior to experiment. They responded that the use of ITS technologies were easy and the technologies were more effective on passive railway crossings.

Vehicle dynamic analysis of continuously controlled semi-active suspension using hardware-in-the-loop simulation (Hardware-in-the-loop 시뮬레이션을 이용한 연속 가변식 반능동 현가 시스템의 차량 동역학적 해석)

  • 황성호;허승진;이교일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1107-1112
    • /
    • 1996
  • A semi-active suspension system with continuously variable damper is greatly expected to be mainly used in the future as a high-performance suspension system due to its cost-effectiveness, light weight, and low energy consumption. To develop the suitable control logic for the semi-active suspension system, the hardware-in-the-loop simulation is performed with the experimental continuously variable damper combined with a quarter-car model. The hardware-in-the-loop simulation results are compared for passive, on/off controlled, and continuously controlled dampers in the aspects of ride comfort and driving safety, assuming each damper to be installed on a vehicle.

  • PDF

Image-based Subway Security System by Histogram Projection Technology

  • Bai, Zhiguo;Jung, Sung-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.3
    • /
    • pp.287-297
    • /
    • 2015
  • A railway security detection system is very important. There are many safety factors that directly affect the safe operation of trains. Security detection technology can be divided into passive and active approaches. In this paper, we will first survey the railway security systems and compare them. We will also propose a subway security detection system with computer vision technology, which can detect three kinds of problems: the spark problem, the obstacle problem, and the lost screw problem. The spark and obstacle detection methods are unique in our system. In our experiment using about 900 input test images, we obtained about a 99.8% performance in F- measure for the spark detection problem, and about 94.7% for the obstacle detection problem.

FCWA(Forward Collision Warning and Avoidance) algorithm using MMW Radar Sensor (레이더 센서를 이용한 종방향 충돌방지 및 회피 알고리즘)

  • 이태훈;유기정;박문수;홍석교
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.389-389
    • /
    • 2000
  • The number of automobiles is rapidly increasing , as are the importance of the car as a way of transportation, and the variety of its uses. In these surroundings, a safety, one of the primary factors which must be considered in automotive engineering, demands a system that aids the driver's vision and perception. In this point of view, development of the more promoted system that complement the existing passive method which relies on just man's ability is the important issue of the advanced traffic system including ITS. In this paper, we provide an algorithm and implementation of a control system that warns the collisions ahead and avoids this situation, using informations about the host-car, target-car and surroundings. The warning is made by an algorithm that decides the degree of safely. With this degree of safely, the controller automatically controls a vehicle's speed to a proper level.

  • PDF

Islanding detection of grid-connected photovoltaic inverters using Automatic phase-shift method (계통연계형 PV 인버터의 자동 위상 이동법에 의한 고립운전 검출)

  • Yun, Jung-Hyeok;Kim, Heung-Geun;Choi, Jong-Woo;Chun, Tae-Won;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.591-594
    • /
    • 2005
  • Islanding of PV systems occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding Is one of the serious problems in an electric power system connected with dispersed power sources. Also, this scan present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding phenomena. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new anti-islanding algorithm is proposed and its validity is verified through simulation and experimental results for utility interconnection of PV system.

  • PDF

A Novel Anti-islanding Algorism for Utility Interconnection of PV System (PV 시스템의 계통연계를 위한 새로운 고립운전 방지 알고리즘)

  • Yun, Jung-Hyeok;Kim, Heung-Geun;Choi, Jong-Woo;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.271-273
    • /
    • 2005
  • Islanding of PV systems occurs when the utility grid is removed but local sources continue to operate and provide power to local loads. Islanding is one of the serious problems in an electric power system connected with dispersed power sources. Also, this can present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding phenomena. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new anti-islanding algorithm is proposed and its validity is verified through simulation and experimental results for utility interconnection of PV system.

  • PDF

An Experimental Study on Mass Driving Anti-Rolling System for Ships (부가질량을 이용한 선박용 횡동요 저감장치에 대한 실험적 연구)

  • Moon, Seok-Jun;Kim, Byung-In;Lee, Sung-Hwi;Ham, Sang-Yong;Jeong, Jong-Ahn;Lee, Kyung-Joong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.727-730
    • /
    • 2004
  • Reduction of a ship's rolling is the most important performance requirement for improving the safety of the crew on board and preventing damage to cargos as well as improving the comfort of the ride. A mass driving anti-rolling system (MD-ARS) might be one candidate of several systems against the ship's rolling. In this paper, three types of MD-ARS, two passive and one active devices, are developed for small ships. After they are installed on the cabin of the small leisure boat, respectively, a series of test is conducted before and after operating them. Through the test, it is confirmed that the roll responses of the ship are pretty well reduced by the system.

  • PDF

Study of Performance Criteria Methodology for Maintenance Effectiveness Monitoring Program for Nuclear Power Plants (원전 정비효과성감시 프로그램의 성능기준설정 방법론 개선)

  • Song, Tae-Young;Yeom, Dong-Un;Hyun, Jin-Woo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.26-32
    • /
    • 2012
  • The systems of the nuclear power plant are designed based on the User Requirement Document, and Korea Hydro & Nuclear Power Co. (KHNP) implements preventive maintenance activities to keep the specific design function of the system consistently. To monitor the preventive maintenance effectiveness, KHNP has also developed maintenance effectiveness monitoring (MR) program based on NUMARC 93-01 since 2003, and has implemented the program in all operating plants. Recently, KHNP has upgraded MR programs by reflecting implementing experiences ; reestablishing the performance monitoring level, improving analysis for standby function and performance criteria for passive components, reestablishing the availability performance criteria and the performance criteria for the same type of components. These upgraded MR programs will contribute to enhance safety and improve equipment reliability through monitoring maintenance effectiveness.