• Title/Summary/Keyword: passive range

Search Result 731, Processing Time 0.025 seconds

Transmitted Noise Reduction of Piezoelectric Smart Panels using Passive/Active Method in Wide Range frequency (수동/능동적 방법을 혼용한 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;박우철
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.73-79
    • /
    • 2001
  • In this paper, the transmitted noise reduction performance of piezoelectric smart panels is experimentally studied. The proposed piezoelectric smart panels are comprised of plate structure on which piezoelectric sensor/actuators are bonded and sound absorbing material is provided. It is a combination of passive and active approaches utilizing a passive effect at high frequencies and an active effect at low frequencies. To prove the concept of piezoelectric smart panels, an acoustic measurement experiment is performed. An acoustic tunnel is designed and its acoustic characteristics are tested. Below 800Hz, the tunnel exhibits a plane wave guide characteristics. When an absorbing material is bonded on a single plate, a remarkable transmitted noise reduction in mid frequency range is observed except the first resonance frequency. By enabling the active control of single smart panel with negative feedback control. about 10dB noise reduction is achieved at the resonance frequencies. The double smart panel got 4dB at the first resonance frequency and has more potential to reduce the transmitted noise in a wide range frequency. Piezoelectric smart panels incorporating passive absorbing material and active piezoelectric devices is a promising technology for noise reduction in a wide range frequency.

  • PDF

Comparison of Hip Rotation Range of Motion in Jiu-Jitsu Athletes With and Without Low Back Pain (주짓수 선수의 허리 통증 유무에 따른 엉덩관절 돌림 가동범위 비교)

  • Yang, Sung-jun;Park, Kyue-nam;Kyung, Moon-soo;Kim, Si-hyun
    • Physical Therapy Korea
    • /
    • v.25 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Background: A limited hip rotational range of motion (ROM) has been considered to be one of characteristics of low back pain (LBP) in athletes. Although LBP frequently occurs in jiu-jitsu athletes, no previous has compared hip rotational ROM between jiu-jitsu athletes with and without LBP. Objects: The aim of the study was to compare ROM for hip internal rotation (IR) and external rotation (ER), and total hip rotation between jiu-jitsu athletes with and without LBP. Methods: Jiu-jitsu athletes were recruited for the LBP group ($n_1=15$) and control group without LBP ($n_2=15$). IR, ER, and total rotational range of hip joint were measured using a goniometer. Analysis of variance was used to compare the ROM between groups and sides. Results: The LBP group showed a significantly lower range of passive hip IR, passive total rotation, active IR, active ER, and active total rotation than the control group (p<.05). Dominant side of passive hip IR and active IR had a significantly lower ROM than non-dominant side (p<.05). In passive ER ROM, non-dominant side was significantly greater than dominant side (p<.05). Conclusion: Compared to jiu-jitsu athletes without LBP, athletes with LBP exhibit a loss of hip rotational ROM. Based on these results, clinicians and athletic trainers should measure hip rotational ROM when designing the management plan for jiu-jitsu athletes with LBP.

Implementation of Passive Telemetry RF Sensor System Using Unscented Kalman Filter Algorithm (Unscented Kalman Filter를 이용한 원격 RF 센서 시스템 구현)

  • Kim, Kyung-Yup;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1861-1868
    • /
    • 2008
  • In this paper, Passive Telemerty RF Sensor System using Unscented Kalman Filter algorithm(UKF) is proposed. General Passive Telemerty RF Sensor System means that it should be "wireless", "implantable" and "batterless". Conventional Passive Telemerty RF Sensor System adopts Integrated Circuit type, but there are defects like complexity of structure and limit of large power consumption in some cases. In order to overcome these kinds of faults, Passive Telemetry RF Sensor System based on inductive coupling principle is proposed in this paper. Because passive components R, L, C have stray parameters in the range of high frequency such as about 200[KHz] used in this paper, Passive Telemetry RF Sensor System considering stray parameters has to be derived for accurate model identification. Proposed Passive Telemetry RF Sensor System is simple because it consists of R, L and C and measures the change of environment like pressure and humidity in the type of capacitive value. This system adopted UKF algorithm for estimation of this capacitive parameter included in nonlinear system like Passive Telemetry RF Sensor System. For the purpose of obtaining learning data pairs for UKF Algorithm, Phase Difference Detector and Amplitude Detector are proposed respectively which make it possible to get amplitude and phase between input and output voltage. Finally, it is verified that capacitive parameter of proposed Passive Telemetry RF Sensor System using UKF algorithm can be estimated in noisy environment efficiently.

The Relationship among the degrees of pain coping strategies, Pain and Depression of patients with Rheumatoid Arthritis (류마티스 관절염 환자의 통증대처, 통증 및 우울정도의 관계)

  • Park, Gyung;Choi, Soon-Hee
    • Journal of muscle and joint health
    • /
    • v.5 no.2
    • /
    • pp.253-264
    • /
    • 1998
  • This study has done for the purpose of investigation among the degrees of pain coping strategies, pain, and depression of patients with rheumatoid arthritis. The subjects of this study were 214 patients diagnosed with rheumatoid arthritis. The data were collected from september 4 to 16, 1995 by questionnaires. The data were analysed by the use of frequency, t-test, Pearson Correlation Coefficients, ANOVA, and Duncan test. The results Were as follows ; 1. The mean score of pain was 213.5(range : 4-390) and that of depression was 21.4 (range : 1-50). The mean score of passive pain coping strategies was 30.2(range : 11-48) and that of active pain coping strategies was 18.6(range : 7-33) 2. The passive pain coping degree showed a positive correlation with the pain degree (r=.475, p=.0001) and the active pain coping degree showed a inversive correlation with that(r= -.296, p=.0001). The passive pain coping degree showed a positive correlation with the depression degree (r=.425, p=.0001) and the active pain coping degree showed a inversive correlation with that(r=-.299, p=.0001). The pain degree showed a positive correlation with the depression degree(r=.374, p=.0001).

  • PDF

The Immediate Effects of Active Ankle ROM exercise on Passive Straight Leg Raising (족관절의 능동 관절가동범위 운동이 수동 하지직거상에 미치는 즉각적 영향)

  • Sim, Hyun-Po;Yoon, Hong-Il;Lee, Jun-Yong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.40-47
    • /
    • 2010
  • Purpose : To exam the effects of active ankle range of motion(ROM) exercise on sciatic nerve movement and provide the evidence that use it to patients with hypomobile sciatic nerve as a nerve mobilization technique. Methods : The subjects consist of 32 asymptomatic healthy adults(male; 15, female; 17) who have limited passive straight leg raising(PSLR) ranges below 70 degrees. First, examiner measures PSLR angles at three times. Then, subject was instructed perform the active ankle ROM exercise(dorsiflexion and plantarflextion) at limited angle. After each subject completed the active ankle ROM exercise, return the starting position and examiner measures the PSLR angles at three times again. Results : First, PSLR range was no significant differences between dominant and non-dominant leg(p >.05). Second, active ankle ROM exercise significantly increased PSLR range by mean of degrees(p <.05). Third, there was no learning effects among the measurement trials(p >.05). Conclusion : These data show that active ankle ROM exercise can mobilize the sciatic nerve. Therefore, it can be applied to patients with hypomobile sciatic nerve(sliding dysfunction) as a neural mobilization technique.

  • PDF

Long-Range Dependence and 1/f Noise in a Wide Area Network Traffic (광역 네트워크 트래픽의 장거리 상관관계와 1/f 노이즈)

  • Lee, Chang-Yong
    • Journal of KIISE:Information Networking
    • /
    • v.37 no.1
    • /
    • pp.27-34
    • /
    • 2010
  • In this paper, we examine a long-range dependence in an active measurement of a network traffic which has been a well known characteristic from analyses of a passive network traffic measurement. To this end, we utilize RTT(Round Trip Time), which is a typical active measurement measured by PingER project, and perform a relevant analysis to a time series of both RTT and its volatilities. The RTT time series exhibits a long-range dependence or a 1/f noise. The volatilities, defined as a higher-order variation, follow a log-normal distribution. Furthermore, volatilities show a long-range dependence in relatively short time intervals, and a long-range dependence and/or 1/f noise in long time intervals. From this study, we find that the long-range dependence is a characteristic of not only a passive traffic measurement but also an active measurement of network traffic such as RTT. From these findings, we can infer that the long-range dependence is a characteristic of network traffic independent of a type of measurements. In particular, an active measurement exhibits a 1/f noise which cannot be usually found in a passive measurement.

A Study on Target Tracking Filter Architecture in Underwater Environment using Active and Passive Sensors (능, 수동센서를 이용한 수중환경에서의 표적추적필터 구조 연구)

  • Lim, Youngtaek;Suh, Taeil
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.517-524
    • /
    • 2015
  • In this paper, we propose a new target tracking filter architecture using active and passive sensors in underwater environment. A passive sensor for target tracking needs a bearing measurement of target. And target tracking filter for using passive sensor has the observability problem. On the other hand, an active sensor does not have the problem associated with system observability problem because an active sensor uses bearing and range measurement. In this paper, the tracking filter algorithm that could be used in the active and passive sensor system is proposed to analyze maneuvering target and to improve target tracking performance. The proposed tracking filter algorithm is tested by a series of computer simulation runs and the results are analyzed and compared with existing algorithm.

Detection Range of Passive Sonar System in Range-Dependent Ocean Environment (거리의존 해양환경에서 수동소나체계의 표적탐지거리예측)

  • Kim, Tae-Hak;Kim, Jea-Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.29-34
    • /
    • 1997
  • The prediction of detection range of a passive sonar system is essential to estimate the performance and to optimize the operation of a developed sonar system. In this paper, a model for the prediction of detection range in a range-dependent ocean environment based on the sonar equation is developed and tested. The prediction model calculates the transmission loss using PE propagation model, signal excess, and the detection probability at each target depth and range. The detection probability is integrated to give the estimated detection range. In order to validate the developed model, two cases are considered. One is the case when target depth is known. The other is the case when the target depth is unknown. The computational results agree well with the previously published results for the range-independent environment. Also,the developed model is applied to the range-dependent ocean environment where the warm eddy exists. The computational results are shown and discussed. The developed model can be used to find the optimal frequency of detection, as well as the optimal search depth for the given range-dependent ocean environment.

  • PDF

Image Measurement and Processing using Near-Range Passive Millimeter-wave Imaging System (근거리 수동 밀리미터파 이미징 시스템을 이용한 영상 측정과 영상처리)

  • Jung, Kyung Kwon;Yoon, Jin-Seob;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.8
    • /
    • pp.159-165
    • /
    • 2015
  • In this paper, we designed and tested of the passive millimeter-wave imaging system in near range. The proposed passive millimeter-wave imaging system consists two parts. The first part is a 94 GHz band millimeter imaging sensor which is coupled to an antenna, two LNAs, and a diode detector. The second part is a control unit. The control unit is consists of the 2-axes Cartesian robot, the data acquisition (DAQ), and imaging program. The 2-axes Cartesian robot should be able to scan a 2-D image of the metalic tools, IC card and plastic objects, with a raster scanning method. The passive millimeter-wave image of $20{\times}20$ pixels is acquired within less than 60s, and is immediately displayed and stored for post processing.In order to improve the image quality, interpolation methods are applied.

The Effect of Different Starting Periods of Passive Exercise on the Clinical Outcome of Arthroscopic Rotator Cuff Repair

  • Back, Young-Woong;Tae, Suk-Kee;Kim, Min-Kyu;Kwon, Oh-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.2
    • /
    • pp.57-63
    • /
    • 2014
  • Background: To compare the effect of different starting periods of rehabilitative exercise (early or delayed passive exercise) on the rate of retear and other clinical outcomes after the arthroscopic repair of the rotator cuff. Methods: In total, 103 patients who underwent arthroscopic repair of the rotator cuff were included in the study. Determined at 2 weeks post-operation, patients who were incapable of passive forward elevation greater than $90^{\circ}$ were allotted to the early exercise group (group I: 79 patients; 42 males, 37 females), whilst those capable were allotted to the delayed exercise group (group II: 24 patients; 14 males, 10 females). The group I started passive exercise, i.e. stretching, within 2 weeks of operation, whilst group II started within 6 weeks. The results were compared on average 15.8 months (11-49 months) post-operation using the passive range of motion, the Visual Analog Scale (VAS) pain score, and the University of California at Los Angeles (UCLA) and Constant scores. Stiffness was defined as passive forward elevation or external rotation of less than $30^{\circ}C$ compared to the contralateral side. Follow-up magnetic resonance imaging (MRI) was carried out on average 1 year post-operation and the rate of retear was compared with Sugaya's criteria. Results: There were no differences between the two groups in gender, age, smoking, presence of diabetes, arm dominance, period of tear unattended, pre-operative range of motion, shape and size of tear, degree of tendon retraction, and tendon quality. There were no significant differences in clinical outcomes. Whilst stiffness was more frequent in group II (p-value 0.03), retear was more frequent in group I (p-value 0.028) according to the MRI follow-up. Conclusions: During rehabilitation after the arthroscopic repair of the rotator cuff, the delay of passive exercise seems to decrease the rate of retear but increase the risk of stiffness.