• Title/Summary/Keyword: passive method

Search Result 1,683, Processing Time 0.029 seconds

Direct position tracking method for non-circular signals with distributed passive arrays via first-order approximation

  • Jinke Cao;Xiaofei Zhang;Honghao Hao
    • ETRI Journal
    • /
    • v.46 no.3
    • /
    • pp.421-431
    • /
    • 2024
  • In this study, a direct position tracking method for non-circular (NC) signals using distributed passive arrays is proposed. First, we calculate the initial positions of sources using a direct position determination (DPD) approach; next, we transform the tracking into a compensation problem. The offsets of the adjacent time positions are calculated using a first-order Taylor expansion. The fusion calculation of the noise subspace is performed according to the NC characteristics. Because the proposed method uses the signal information from the previous iteration, it can realize automatic data associations. Compared with traditional DPD and two-step localization methods, our novel process has lower computational complexity and provides higher accuracy. Moreover, its performance is better than that of the traditional tracking methods. Numerous simulation results support the superiority of our proposed method.

An Implementation of Stabilizing Controller for 2-Axis Platform using Adaptive Fuzzy Control and DSP

  • Ryu, Gi-Seok;Kim, Jin-Kyu;Park, Jang-Ho;Kim, Dae-Young;Kim, Jong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.71.3-71
    • /
    • 2001
  • Passive Stabilization method and active stabilization method are mainly used to comprise a control system of platform stabilizer. Passive Stabilization method has demerits because of size and weight except that control structure is simple while active stabilization method using sensors can reduce size and weight, it requires high sensor technique and control algorithm. In this paper, a stabilizing controller using adaptive fuzzy control technique and floating-point processor(DSP) is suggested.

  • PDF

Finite Element Analysis of the Direct Shear Test (직접 전단시험의 유한 요소 해석)

  • 이장덕
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.21-36
    • /
    • 1996
  • The stress transfer mechanism between soil and grid reinforcements involves two basic mechanism : frictional soil resistance and passive soil resistance. However the mechanism of the passive soil resistance is very complex to understand. To study the failure mechanism of ribbed reinforcement, the direct shear tests which are dominated by passive soil resistance are analyzed by using the finite element method. The finite element method is used to examine the effects of ribs on this passive soil resistance development and the met hanism of failure. The calculated behavior of the ribbed reinforcement is compared with the measured behavi or. Comparisons between the measured and the simulated strain pat terns, failure modes and load displacement relationship are presented. The behavior of the ribbed reinforcements in a cohesive soil is predicted on the basis of a good agreement between the measured and the Predicted behavior of the Ottawa sand.

  • PDF

Investigation and Implementation of a Passive Snubber with a Coupled-Inductor in a Single-Stage Full-Bridge Boost PFC Converter

  • Meng, Tao;Ben, Hongqi;Li, Chunyan;Wei, Guo
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.206-213
    • /
    • 2013
  • In this paper, an improved passive snubber is investigated in a single-phase single-stage full-bridge boost power factor correction (PFC) converter, by which the voltage spike across primary side of the power transformer can be suppressed and the absorbed energy can be transferred to the output side. When compared with the basic passive snubber, the two single-inductors are replaced by a coupled-inductor in the improved snubber. As a result, synchronous resonances in the snubber can be achieved, which can avoid the unbalance of the voltage and current in the snubber. The operational principle of the improved passive snubber is analyzed in detail based on a single-phase PFC converter, and the design considerations of both the snubber and the coupled-inductor are given. Finally, a laboratory-made prototype is built, and the experimental results verify the feasibility of the proposed method and the validity of the theoretical analysis and design method.

Performance Analysis of Data Association Applied Frequency Weighting in 3-Passive Linear Array Sonars (주파수 가중치를 적용한 3조의 수동 선배열 소나 센서의 정보 연관 성능 분석)

  • 구본화;윤제한;홍우영;고한석
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.109-116
    • /
    • 2004
  • This paper deals with data association using 3 sets of passive linear array sonars (PUS) geometrically positioned in a Y-shaped configuration, but fixed in an underwater environment. The data association problem is directly transformed into a 3-D assignment problem, which is known to be NP-hard. For generic passive sensors, it can be sotted using conventional algorithms, while it in PLAS becomes a formidable task due to the presence of bearing ambiguity. In particular, we proposed data association method robust to bearing measurements errors by incorporating frequency information and analyze a region of ghost problem by geometrical relation PUS and target. We analyzed the effectiveness of the proposed method by representative simulation in multi-target.

A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter (직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구)

  • Oh, Jae-Hoon;Ko, Su-Hyun;Han, Yoon-Seok;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

Uniform-fiber-Bragg-grating-based Fabry-Perot Cavity for Passive-optical-network Fault Monitoring

  • Xuan, Zhang;Ning, Ning;Tianfeng, Yang
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.47-53
    • /
    • 2023
  • We propose a centralized passive-optical-network monitoring scheme using the resonance-spectrum properties of a Fabry-Perot cavity based on fiber Bragg gratings. Each cavity consists of two identical uniform fiber Bragg gratings and a varying cavity length or grating length, which can produce a unique single-mode resonance spectrum for the drop-fiber link. The output spectral properties of each cavity can be easily adjusted by the cavity length or the grating length. The resonance spectrum for each cavity is calculated by the transfer-matrix method. To obtain the peak wavelength of the resonance spectrum more accurately, the effective cavity length is introduced. Each drop fiber with a specific resonance spectrum distinguishes between the peak wavelength or linewidth. We also investigate parameters such as reflectivity and bandwidth, which determine the basic performance of the fiber Bragg grating used, and thus the output-spectrum properties of the Fabry-Perot cavity. The feasibility of the proposed scheme is verified using the Optisystem software for a simplified 1 × 8 passive optical network. The proposed scheme provides a simple, effective solution for passive-optical-network monitoring, especially for a high-density network with small end-user distance difference.

A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System (PMSG 기반 풍력발전용 계통연계 인버터의 신뢰성 향상을 위한 새로운 하이브리드 단독운전 방지기법)

  • Kang, Sung-Wook;Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.27-36
    • /
    • 2013
  • Islanding in a gird connected inverter of wind power generation system may influence a bad effect on equipments or yield safety hazards on grid so it should be detected rapidly and exactly. A passive method to detect islanding is comparatively simpler than an active method but suffers from non detection zone (NDZ). On the other hand, the active method can significantly reduce NDZ by injecting a disturbance into inverter output. To improve the reliability of islanding detection, this paper proposes a hybrid anti-islanding detection method combining the conventional passive method as well as the active method based on novel harmonic injection method using fourier transform. The proposed scheme is fast to detect islanding when NDZ does not exist because it has the nature of passive method. Under NDZ, the active method can detect occurrence of islanding reliably. The effectiveness and validity of the proposed scheme is proved through comparative simulations.

The Effects of Passive Stretching of the Iliopsoas Muscles on Pulmonary Function (엉덩허리근에 대한 수동 신장이 폐 기능에 미치는 영향)

  • Han, Dong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.3
    • /
    • pp.79-86
    • /
    • 2022
  • PURPOSE: By virtue of its location, the iliopsoas muscle has the potential to affect the function of the diaphragm. Therefore, the purpose of this study was to investigate the effects of passive stretching of the iliopsoas muscles on pulmonary function. METHODS: Twenty male university students participated in this study. Subjects with low back pain, negative results on the modified Thomas test, and chest breathing patterns not directly related to the function of the iliopsoas muscles were excluded from this study. A digital pulmonary function measuring device (Pony FX, COSMED Inc, Italy) was used to test pulmonary function. The test was performed three times: the first test before passive stretching, the second test 10 minutes after the first test, and the third after passive stretching. Passive stretching was performed 5 times for each of the left and right iliopsoas muscles. Passive stretching was carried out for 20 seconds followed by a 10-second break. The SPSSWIN (ver. 27.0) statistics program was used for data analysis, and the significance level was α =.05. RESULTS: Among slow vital capacity (SVC) parameters, tidal volume (VT), inspiratory reserve volume (IRV), inspiratory capacity (IC) and vital capacity (VC) improved significantly after passive stretching. Also, among the maximal effort vital capacity (MEVC) parameters, forced vital capacity(FVC) and forced expiratory volume in one second(FEV1) improved significantly after passive stretching. CONCLUSION: The results showed that among the various pulmonary function parameters measured, passive stretching of the iliopsoas muscles can improve the SVC and MEVC. Therefore, passive stretching of the iliopsoas muscles may be considered for use as a treatment method to improve pulmonary function.