• Title/Summary/Keyword: passive construction

Search Result 267, Processing Time 0.027 seconds

Unaccusativity and L2 Passive Construction

  • Kim, Jung-Tae
    • English Language & Literature Teaching
    • /
    • v.12 no.4
    • /
    • pp.69-89
    • /
    • 2006
  • This study investigated whether and how semantic nature of intransitive verbs can be related to the L2 overpassivization errors. A total of 126 Korean high school students participated in a grammaticality judgment test on English sentences in which seven semantically different types of intransitive verbs were passivized. The results showed that there was an effect of semantic type on the students' judgment on overpassivization errors. Overall, it was shown that the students experienced the lowest degree of difficulty with the Controlled Process-Motional type verbs while experiencing the high degree of difficulty with the Change of State, Existence of State, Continuation of Pre-existing State, and Uncontrolled Process types. Two interlanguage patterns were also identified: the students at higher proficiency level and those at lower-proficiency level showed distinctive patterns on the task. It was argued that the simple dichotomy of unaccusative-unergative distinction does not suffice for the explanation of the complex phenomenon of L2 overpassivization.

  • PDF

Optimal distribution of the cable tensions and structural vibration control of the cable-cabin flexible structure

  • Qiu, Y.Y.;Duan, B.Y.;Wei, Q.;Nan, R.D.;Peng, B.
    • Structural Engineering and Mechanics
    • /
    • v.14 no.1
    • /
    • pp.39-56
    • /
    • 2002
  • In order to trace a target in deep sky, a feed cabin 20 tons in weight used for a large radio telescope is drawn with six cables. To realize a smooth tracing all the time, optimal distribution of the cable tensions is explored. A set of cable-clog systems is utilized to control the wind-induced vibration of the cable-cabin structure. This is an attempt to apply the passive structural control strategy in the area of radio astronomy. Simulations of wind-induced vibration of the structure in both time and frequency domains offer a valuable reference for construction of the next generation large radio telescope.

Effects of an Apartment Complex on Flow and Dispersion in an Urban Area (도시 지역에서 아파트 단지가 흐름과 확산에 미치는 영향)

  • Lee, Young-Su;Kim, Jae-Jin
    • Atmosphere
    • /
    • v.21 no.1
    • /
    • pp.95-108
    • /
    • 2011
  • The effects of an apartment complex on flow and pollutant dispersion in an urban area are numerically investigated using a computational fluid dynamics (CFD) model. The CFD model is based on the Reynolds-averaged Navier-Stokes equations and includes the renormalization group k-${\varepsilon}$ turbulence model. The geographic information system (GIS) data is used as an input data of the CFD model. Eight numerical simulations are carried out for different inflow directions and, for each inflow direction, the effects of an apartment complex are investigated, comparing the characteristics of flow and dispersion before and after construction of the apartment complex in detail. The observation data of automatic weather system (AWS) is analyzed. The windrose analysis shows that the wind speed and direction after the construction of the complex are quite different from those before the construction. The construction of the apartment complex resulted in the decrease in wind speed at the downwind region. It is also shown that the wind speed increased partially inside the apartment complex due to the channeling effect to satisfy the mass continuity. On the whole, the wind speed decreased at the downwind region due to the drag effect by the apartment complex. As a result, the passive pollutant concentration increased (decreased) near the downwind region of (within) the apartment complex compared with that before the construction.

Correlation Analysis on the Duration and CO2 Emission Following the Earth-work Equipment Combination (토공장비조합에 따른 공사기간 및 이산화탄소 배출량의 상관성 분석)

  • Kim, Byungsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4D
    • /
    • pp.603-611
    • /
    • 2011
  • After Kyoto Protocol was adopted for green gas reduction, each nations are stepping up efforts to reduce $CO_2$ of a typical green gas. Construction industry also is trying $CO_2$ reduction with the techniques of two types which are software and hardware techniques. The software technique are Passive Design considered green gas emission and the environment impact assessment by LCA. The hardware techniques are adjustment of equipment system and development of eco- friendly material. But, it is nonexistent that a study related to $CO_2$ emission considered detail process in construction industry. This study analyzed the correlation of equipment combination, $CO_2$ emission and duration by calculate $CO_2$ emission follow to equipment combination on earth-work which is the process emitted most $CO_2$ among railway bedding construction.

A design approach of integral-abutment steel girder bridges for maintenance

  • Kim, WooSeok;Jeong, Yoseok;Lee, Jaeha
    • Steel and Composite Structures
    • /
    • v.26 no.2
    • /
    • pp.227-239
    • /
    • 2018
  • Integral abutment bridges (IABs) have no joint across the length of bridge and are therefore also known as jointless bridges. IABs have many advantages, such as structural integrity, efficiency, and stability. More importantly, IABs have proven to be have both low maintenance and construction costs. However, due to the restraints at both ends of the girder due to the absence of a gap (joint), special design considerations are required. For example, while replacing the deck slabs to extend the service life of the IAB, the buckling strength of the steel girder without a deck slab could be much smaller than the case with deck slab in place. With no deck slab, the addition of thermal expansion in the steel girders generates passive earth pressure from the abutment and if the applied axial force is greater than the buckling strength of the steel girders, buckling failure can occur. In this study, numerical simulations were performed to estimate the buckling strength of typical steel girders in IABs. The effects of girder length, the width of flange and thickness of flange, imperfection due to fabrication and construction errors on the buckling strengths of multiple and single girders in IABs are studied. The effect of girder spacing, span length ratio (for a three span girder) and self-weight effects on the buckling strength are also studied. For estimation of the reaction force of the abutment generated by the passive earth pressure of the soil, BA 42/96 (2003), PennDOT DM4 (2015) and the LTI proposed equations (2009) were used and the results obtained are compared with the buckling strength of the steel girders. Using the selected design equations and the results obtained from the numerical analysis, equations for preventing the buckling failure of steel girders during deck replacement for maintenance are presented.

Energy Performance and Operating Cost Assessment for Implementing Green Remodeling Technologies in a Detached House (단독주택 건물 그린리모델링에 따른 건물 에너지 성능과 운전비용 절감 효과 평가)

  • Byonghu Sohn;Su-In Lee;Jae-Sik Kang
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.4
    • /
    • pp.27-38
    • /
    • 2023
  • The Government the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of buildings and to promote green growth policy in construction sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. Green remodeling reinforced the insulation of the exterior walls and roofs of the buildings and replaced high-efficiency windows and doors. In this study, the energy performance before and after green remodeling applied in a detached house was comparatively analyzed for baseline scenario and three different ones, ALT 1, ALT 2 and ALT 3. A building modeling and simulation software (DesignBuilder V7.0) with EnergyPlus (V9.4) calculation engine was used to calculate the energy demand and energy consumption for each scenario. Based on the calculation results of the building's energy demand for baseline, it was determined that the target building required more heating energy than cooling energy. The simulation results also showed that the implementation of building envelope performance improvement technologies (ALT 1) could notably decrease the heating energy consumption of the building. After the remodeling (ALT 1), the source energy consumption per unit floor area was assessed to be reduced by 65.2%, compared to prior remodeling of 338.7 kWh/m2 -y. Meanwhile, ALT 2 can achieve energy savings of 67.7% and ALT 3 can achieve savings of 73.1%. Following completion of the remodeling project, actual construction costs, and on-site measurements and verification results will be gathered and compared with the simulation results. Additionally, economic analysis including construction costs and payback period will be conducted using actual site data.

Selecting of Earth-work Equipment Combination Considered CO2 Emission (이산화탄소 배출량을 고려한 토공 장비조합의 선정)

  • Kim, Byung-Soo
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1750-1756
    • /
    • 2011
  • After Kyoto Protocol was adopted for green gas reduction, each nations are stepping up efforts to reduce $CO_2$ of a typical green gas. Construction industry also is trying $CO_2$ reduction with the techniques of two types which are software and hardware techniques. The software technique are Passive Design considered green gas emission and the environment impact assessment by LCA. The hardware techniques are adjustment of equipment system and development of eco- friendly material. But, it is nonexistent that a study related to $CO_2$ emission considered detail process in construction industry. This study analyzed the relativeness of equipment combination and $CO_2$ emission by calculate $CO_2$ emission follow to equipment combination on earth-work which is the process emitted most $CO_2$ among railway bedding construction.

  • PDF

Weak Connectivity in (Un)bounded Dependency Constructions

  • Kim, Yong-Beom
    • Proceedings of the Korean Society for Language and Information Conference
    • /
    • 2007.11a
    • /
    • pp.234-240
    • /
    • 2007
  • This paper argues that various kinds of displaced structures in English should be licensed by a more explicitly formulated type of rule schema in order to deal with what is called weak connectivity in English. This paper claims that the filler and the gap site cannot maintain the total identity of features but a partial overlap since the two positions need to obey the structural forces that come from occupying respective positions. One such case is the missing object construction where the subject fillers and the object gaps are to observe requirements that are imposed on the respective positions. Others include passive constructions and topicalized structures. In this paper, it is argued that the feature discrepancy comes from the different syntactic positions in which the fillers are assumed to be located before and after displacement. In order to capture this type of mismatch, syntactically relevant features are handled separately from the semantically motivated features in order to deal with the syntactically imposed requirements.

  • PDF

An Study on Efficiency and Application of Thermal Siphon in the Permafrost (영구동토 지대에서 Thermal Siphon의 효율성 연구)

  • Kang, Jae-Mo;Kim, Hak-Seung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.963-966
    • /
    • 2009
  • A Construction of pipe line foundation and railroad, buildings in a permafrost area requires engineering technology of ground stabilization. In the permafrost area, thermal siphons have been used to stabilize foundation by eliminating the heat of ground to the air. the thermal siphon is a passive heat transfer device that operates by convection through vaporization and condensation. The heat transfer from ground to the air is driven by a temperature difference across the unit. A buried part in ground working as vaporizing function and upper part work as condensing. In this study, buried thermal siphon around the pipe lines laid in the Vladivostok site and measuring temperature variation. It is found that the thermal siphons freezing ground faster and decrease temperature variation in winter season.

  • PDF

The Study Of Optimum Method About The Architecture, Construction, And Maintenance Through The Construction Of Zero Energy House (제로 에너지 하우스 구축을 통한 설계, 시공, 유지관리 최적 방안에 관한 연구 및 제안)

  • Kim, Sun-Geun;Kwon, Soon-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.42-50
    • /
    • 2014
  • In the thesis, the case of zero energy house construction applied with various Active factors and Passive factors which is the real residence as a standard not a normal experimental residence was evaluated, analyzed, and organized. The thesis can be the base data to construct another similar case of zero energy house.