• Title/Summary/Keyword: passed charge

Search Result 81, Processing Time 0.021 seconds

Diffusion of Chloride Ions in Limestone Powder Concrete

  • Moon Han-Young;Jung Ho-Seop;Kim Jong-Pil
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.859-865
    • /
    • 2004
  • In this study, the diffusion of chloride ions in cement concrete made with and without the limestone powder was investigated. In order to study the effect of the limestone powder, all mixtures were prepared at a fixed water-cementitious ratio (0.45). From the experimental results, the setting time of limestone powder concrete is faster than that of control concrete, and compressive strength of all specimens decreased with increasing replacement ratio of limestone powders. The diffusion properties of limestone powder concretes indicated a trend increasing with curing period. LSA10 and LSA20 concretes, the diffusion coefficient was smaller than that of control concrete. The addition of $10-20\%$ limestone powder reduces the diffusion coefficient of chloride ions, irrespective of fineness levels of limestone powder.

A simplified method to determine the chloride migration coefficient of concrete by the electric current in steady state

  • Lin, K.T.;Yang, C.C.
    • Computers and Concrete
    • /
    • v.13 no.1
    • /
    • pp.117-133
    • /
    • 2014
  • This study presents a rapid method for determining the steady state migration coefficient of concrete by measuring the electric current. This study determines the steady state chloride migration coefficient using the accelerated chloride migration test (ACMT). There are two stages to obtain the chloride migration coefficient. The first stage, the steady-state condition was obtained from the initial electric current at the beginning of ACMT. The second stage, the average electrical current in the steady state condition was used to determine the steady state chloride migration coefficient. The chloride migration coefficient can be determined from the average steady state current to avoid sampling and analyzing chlorides during the ACMT.

Estimation on the Sulfate Ion Diffusivity in Concrete by Accelerated Test (촉진시험에 의한 콘크리트중의 황산이온 확산계수 추정)

  • 문한영;김성수;김홍삼;이승태;최두선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.425-428
    • /
    • 2000
  • When concrete structures are exposed to sulfate or marin environments, sulfate ions penetrated into concrete make it deteriorate. An accelerated test under potential difference method was performed to evaluate not only the sulfate ion diffusivity in ordinary portland cement and ground granulated blast-furnace slag cement concretes but the effect of slag replacement and water-cement ratio on the sulfate ions diffusivity. As the result of this study, we assumed the sulfate ion diffusivity was significantly related with total passed charge and initial current in concrete. Moreover sulfate ions penetration resistance of ordinary portland cement concrete was superior to that of ground granulated blast-furnace slag cement concrete.

  • PDF

Chloride Ion Diffusion Characteristics of Fly ash. Concrete with Age (재령에 따른 플라이 애쉬 콘크리트의 염소이온 확산특성)

  • 이재호;이광명;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.681-686
    • /
    • 2003
  • One of the major degradation processes of reinforced concrete (RC) structure is corrosion of reinforced steel due to chloride attack. Severe environments, such as marine environment and exposure to de-icing salts, could accelerate the steel corrosion of RC structures through the chloride ion intrusion into concrete. In order to delay this degradation process, several kinds of admixtures have been used in concrete mix. In this study, effective diffusion coefficient of chloride ion ($D_{eff}$) and total passed charge of concrete with and without fly ash were measured using electrical method. It is found that fly ash concrete has much less chloride ion coefficient than ordinary concrete at later age. By analyzing the test results, $D_{eff}$ at 28 and 90 days was obtained as a function of water-binder ratio (W/B) and an equation for predicting $D_{eff}$ with age was proposed considering the decreasing rate of $D_{eff}$.

  • PDF

An Experimental Study on the Strength and Permeability Characteristics of Repair Mortar (보수용 모르타르의 강도 및 투과특성에 관한 연구)

  • Paik, Shin-Won
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.105-109
    • /
    • 2003
  • Structure surfaces damaged due to many causes are repaired by several special mortars. But wide studies about the permeability of these mortars were rarely conducted. In this study compressive strength test, flexural strength test and bond strength test of these mortars were conducted. And chloride ion penetration test was also conducted to explore the permeability charcteristics of selected repair mortars. This test was carried out following the standard ASTM C1202-91. Colouriemtric penetration depth can be drawn from these test results using a relationship equation between colourimetric penetration depth and charge passed which C. Andrade suggested. Diffusion coefficient can be calculated by CTH rapid method. To the end, the present study can provide a firm base for the application of repair mortars to concrete structures.

Modified Driving Method for Reducing Address Time During Subfield Time in AC PDP (플라즈마 디스플레이 패널에서 부화면 시간동안 기입시간을 단축시키기 위한 수정된 구동파형)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.135-139
    • /
    • 2015
  • The address discharge time lags are investigated in each subfield time in AC plasma display panel and a modified driving waveform is proposed to reduce the address discharge time lag by applying different additional scan voltage under no misfiring discharge production. The weak plasma discharge in AC PDP is generated by applying high positive-going ramp waveform to the scan electrode during the first reset period and that induce the production of the priming particle and wall charge. Because the wall charge becomes the wall voltage in a cell, the wall plus external address voltage produce the address discharge. However, as the wall charge in a cell is gradually disappeared as time passed, the address discharge time in the subfield time for 1 TV frame is lagged. In the first subfield time, the address discharge is faster produced than the other subfield time because the wall charge are much remained by the high positive-going ramp voltage during the reset period in the first subfield time. Meanwhile, from the second to last subfield, the address discharge production time is gradually delayed due to the dissipation of the wall charge in a cell. In this study, the address discharge time lags are measured in each subfield time and the total address discharge time lags are shortened by applying the different additional scan voltage during the address period in each the subfield time.

A Study on the Container Charges of Pusan Container Terminal (부산 콘테이너 부두의 하역료에 관한 연구 - 공영기업 차원의 요금산정을 중심으로 -)

  • Lee, Cheol-Yeong;Lee, Kwang-Hee
    • Journal of Korean Port Research
    • /
    • v.3 no.1
    • /
    • pp.3-33
    • /
    • 1989
  • The amount of the Korean export & import in 1987 reached $88.3 billion which was 1.75% of the total world trade and the proportion of foreign dependence to G.N.P was 74.5%. From these facts, we can infer that the development of national economy is largely dependent upon trade. Therefore the role of transportation, especially Ocean transportation, as a basis of economic development through trade is one of the main factors that can not be passed over. Here, We can define that a port as a subsystem of transportation determines the efficiency of the total transportation system. Thus, the purpose of this paper is to contribute in improvement of the efficiency in port, reinforcement of the international competitiveness for exporting goods by the analysis of the cargo handling charges. In order to do this, this paper deals the case of B.C.T.O.C. Furthermore, this study gives some important informations related to the level of tariffs for establishing an autonomous port administration. The Summary of the conclusions of this paper is as follows ; 1) The object of port administration in Korea has been emphasized on the maximization of efficiency in using the port facilities. Nowadays, however, it should be moved to a direction that port is operated under the compound aims considering the public interests and economy. 2) For a criterian of tariff calculation, A tariff system based on the cost accounting is desirable. In general it is recommended that the cost for construction, management, and operation of port is compensated by the revenue from port operation. Therefore, it is necessary for the administration bodies of each port to establish a tariff system on the basis of the independent profit system. 3) For the investigation of actors of tariff adjustment by the Break-even point analysis, (1) When we conducted the B.E.P analysis using total cost as cost term, we got 3.8% discount in tariff at 12% of target profit rate and 1.5% discount at 15% of rate. when we set the target profit rate as 17% we could have the proper tariff level. (2) When using operating cost as cost term, we got 13.1% discount in tariff at 12% of target profit rate and 10.9% discount at 15% of rate. When setting the target profit rat as 28%, we could have the proper tariff level. 4) Comparing with the tariffs of foreign ports for the basic terminal rate, The tariff level of B.C.T.O.C showed 33% of stevedoring charge and 80% of marshalling charge incurred at Kobe port. The comparison with Singapore port gave 50% of transhipment charge and 17% - 20 % of stevedoring charge. 5) We found that the financial structure of B.C.T.O.C was better than those of other companies and the worth fixed assets ratio was too low. The fact of low worth fixed assets ratio implies that the cargo handling facilities should be increased. Moreover, The return of assets for B.T.T.O.C was good but non-operating expenses were still contained too much in. Therefore, we think that it is necessary for B.C.T.O.C. to rationalize business management. Although the present cargo handing charge for B.C.T.O.C is a proper level in terms of a public corporation, for the final recommendation in connection to the results, It is required to take the rationalization process for business management.

  • PDF

Evaluation of Chloride Diffusion Behavior and Analysis of Probabilistic Service Life in Long Term Aged GGBFS Concrete (장기 재령 GGBFS 콘크리트의 염화물 확산 거동 평가 및 확률론적 염해 내구수명 해석)

  • Yoon, Yong-Sik;Kim, Tae-Hoon;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.47-56
    • /
    • 2020
  • In this study, three levels of W/B(Water to Binder) ratio (0.37, 0.42, 0.47) and substitution ratio of GGBFS (Ground Granulated Blast Furnace Slag) rate (0 %, 30 %, 50 %) were considered to perform RCPT (Rapid Chloride Diffusion Test) at the 1,095 aged day. Accelerated chloride diffusion coefficient and passed charge of each concrete mixture were assessed according to Tang's method and ASTM C 1202, and improving behaviors of durability performance with increasing aged days are analyzed based on the test results of previous aged days from the preceding study. As the age of concrete increases, the passed charge and diffusion coefficient have been significantly reduced, and especially the concrete specimens containing GGBFS showed a significantly more reduction than OPC(Ordinary Portland Cement) concrete specimen by latent hydraulic activity. In the case of OPC concrete's results of passed charge, at the 1,095 days, two of them were still in the "Moderate" class. So, if only OPC is used as the binder of concrete, the resistance performance for chloride attack is weak. In this study, the time-parameters (m) were derived based on the results of the accelerated chloride diffusion coefficient, and the deterministic and probabilistic analysis for service life were performed by assuming the design variable as a probability function. For probabilistic service life analysis, durability failure probabilities were calculated using Monte Carlo Simulation (MCS) to evaluate service life. The service life of probabilistic method were lower than that of deterministic method, since the target value of PDF (Probability of Durability Failure) was set very low at 10 %. If the target value of PDF suitable for the purpose of using structure can be set and proper variability can be considered for each design variable, it is believed that more economical durability design can be made.

Compressive Strength and Chloride Permeability of High Strength Concrete according to the Variety of Mineral Admixtures (광물질혼화재 종류별 고강도콘크리트의 압축강도 및 촉진 염소이온침투 특성)

  • Moon Han-Young;Kim Byoung-Kwon
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.407-414
    • /
    • 2004
  • The purpose of this study is to evaluate the ability to resist chloride ions penetration of the concrete structure under marine environment in south-east asia especially. In this study, high strength concrete(HSC) with various combination of ordinary portland cement(OPC), blast-furnace slag(SG) and silica fume(SF) are cured 23 and $35^{\circ}C$ considering the site weather, and are cured in water for 3, 7 or 56 days respectively. And to investigate the fundamental properties and the resistance of chloride penetration of various HSC, setting time, slump flow, compressive strength, void and ASTM C 1202 test were conducted. Test results show that the compressive strength of HSC is similar regardless of SG replacement ratio and total charge passed of chloride is the smallest at 40% replacement of SG. The compressive strength of G4FS HSC is, besides, outstandingly high at early age compare with other HSC, but the compressive strength of G4F HSC, which is vary according to curing temperature and condition, most high at the age after 7 days. Total passed charge of HSC get larger in the order G4FS

Strength and Resistance to Chloride Penetration in Concrete Containing GGBFS with Ages (GGBFS를 혼입한 콘크리트의 재령에 따른 강도 및 염소이온 침투 저항성)

  • Park, Jae-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.307-314
    • /
    • 2017
  • Concrete is a durable and cost-benefit construction material, however performance degradation occurs due to steel corrosion exposed to chloride attack. Penetration of chloride ion usually decreases due to hydrates formation and reduction of pores, and the reduced chloride behavior is considered through decreasing diffusion coefficient with time. In the work, HPC (High Performance Concrete) samples are prepared with 3 levels of W/B (water to binder) ratios of 0.37, 0.42, and 0.27 and 3 levels of replacement ratios of 0%, 30% and 50%. Several tests containing chloride diffusion coefficient, passed charge, and compressive strength are performed considering age effect of 28 days and 180 days. Chloride diffusion is more reduced in OPC concrete with lower W/B ratio and GGBFS concrete with 50% replacement ratio shows significant reduction of chloride diffusion in higher W/B ratio. At the age of 28 days, GGBFS concrete with 50% replacement ratio shows more rapid reduction of chloride diffusion than strength development, which reveals that abundant GGBFS replacement has effective resistance to chloride penetration even in the early-aged condition.