• 제목/요약/키워드: pass-by test

검색결과 455건 처리시간 0.031초

견인구동시스템 시험을 위한 개선된 프로그램어블 다이나모메터 제어 (Improved Programmable-Dynamometer Control For Traction Drive System Testing)

  • 김길동;홍재성;신정렬;이우동;한석윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.427-432
    • /
    • 2003
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of moter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for meter torque of programmable dynamometer. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction meter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법 (A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter)

  • 이복희;엄주홍
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

전동기 시험을 위한 프로그램어블 다이나오메터 제어 (Programmable-Dynamometer Control For Traction Motor Testing)

  • 김길동;홍재성;안태기;이호용;신종렬;한석윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1108-1110
    • /
    • 2003
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of meter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for meter torque of programmable dynamometer. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction moter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

허프변환을 이용한 운전면허시험 코스의 개선 (A Study on the Improvement of the Drive-License Test Course using the Hough Transform)

  • 이준택;정동근;정창화
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권6호
    • /
    • pp.153-159
    • /
    • 2010
  • 본 논문은 영상처리를 통해 운전면허시험 시스템의 코스 주행 시스템을 개선하는 방법을 제시한다. 주행차량에 장착된 이미지 캡처장비를 통해, 디지털 이미지를 취득하고, 이에 대한 그레이스케일, 표본화, 허프변환 등의 영상처리과정을 거쳐 결정사항이 중앙시스템에 기록되고, 주행자에게 합격여부를 알려주게 되며, 이러한 시스템을 통해, 경제적이고 효율적인 운영이 가능해진다.

TMS320C32를 이용한 한시 과전류 계전기의 구현 (Implementation of an Over-Current Relaying Algorithm with TMS320C32)

  • 유성록;윤병욱;박병우;최창영;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2193_2194
    • /
    • 2009
  • A digital over current relay(OCR) is realized by using TMS320C32 microprocessor. Fourier Transform is used to obtain the phasor of a current signal and a 2nd low pass filter is adopted to prevent aliasing error. H/W test shows almost same results with those of the S/W test. It could be possible that confirm simularity between H/W and S/W test in this paper.

  • PDF

자유항주모형시험과 회귀분석을 통한 선체 동역학 모델의 개발 (Development of Ship Dynamics Model by Free-Running Model Tests and Regression)

  • 김기원;김호용;최성은;나기인;이혁;서정화
    • 대한조선학회논문집
    • /
    • 제59권3호
    • /
    • pp.173-182
    • /
    • 2022
  • The present study suggests a procedure of establishing a ship dynamics modeling by regression of free-running model test results. The hydrodynamic force and moment of the whole model ship is derived from the low-pass filtered acceleration in the turning circle and zigzag maneuver tests. Force and moment of the propeller and rudder are separated from that of the whole ship to acquire the hull force and moment terms, based on the principles of the component model. The low-pass filter frequency is verified in prior to dynamics modeling, to find the threshold frequency of 2.5 Hz. The dynamics modeling of the hull is compared with the component modeling by captive model tests. Because of strong correlation between sway velocity, yaw angular velocity, and heel angle, each maneuvering coefficient is not able to be validated, but the whole modeling shows good agreement with the captive model tests.

군용차량의 주행모드에 따른 상대 노면 가혹도 분석 (Relative Road Damage Analysis with Driving Modes of a Military Vehicle)

  • 서권희;송부근;윤희석
    • 한국자동차공학회논문집
    • /
    • 제24권2호
    • /
    • pp.225-231
    • /
    • 2016
  • A military vehicle is driven at different usage modes with the army application and servicing conditions. For practical durability validation, DT(Development Test) on a new military vehicle should be run up to the durability target kilometers on test courses in the specified proving ground. Driving velocities with test courses at the endurance mode of DT are established definitely. However, OT(Operational Test) and initial endurance test of production car can't be performed only in the DT courses due to the development period limit. Therefore, this paper focuses on the method to analyze the relative road damages between the endurance test in DT and other endurance test. Road load acquisition tests on KLTV(Korean Light Tactical Vehicle) were implemented at 15 driving modes in off-road and cross-country courses of two tests. Wheel accelerations were processed through band-pass filter, and then the main frequency and maximum power of the signals were computed by PSD analysis. Finally, using the proving ground optimization based on RDS(Relative Damage Spectrum) characterization, the damage factors between off-roads of test courses were determined.

BDU 신뢰성 검증 (Reliability Verification of Battery Disconnecting Unit)

  • 윤혜림;유행수;박지홍;박홍태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.866-867
    • /
    • 2011
  • As part of the green growth, The Green Car has attracted wide attention. Types of the Green Car are Electric Vehicle, Plug-in Hybrid Electric Vehicle, Hybrid Electric Vehicle, Fuel Cell Vehicle and Clean Diesel Vehicle. Of these, The electric vehicle is equipped with the BDU(Battery Disconnecting Unit). BDU is supplying stable battery power and blocking it to protect electrical system of the electric vehicle. The BDU consists of electric components such as current sensor, fuse and pre-charge resistor. These must pass Voltage withstand test, Salt mist test, Thermal shock test, Vibration test and Short-circuit test commonly to verify reliability of the electric components. In addition, The current sensor should be verified whether normal operation. The breaking capacity of fuse should be verified. The durability of pre-charge resistor should be verified by supplying battery power and blocking it repeatedly. The reliability of BDU as well as the electric vehicle is secured by verifying the reliability of electric components. In addition, It will contribute to the acceleration and promotion of Green Car Technology.

  • PDF

API X-100의 레이저-아크 하이브리드 용접성에 미치는 용접와이어의 영향 (The Effects of Welding Wires on the Weldabilities of API X-100 with Laser-Arc Hybrid Welidng)

  • 김성욱;이목영
    • Journal of Welding and Joining
    • /
    • 제32권5호
    • /
    • pp.7-12
    • /
    • 2014
  • In this study, API-X100 steel pipes were welded with various kinds of welding wires in the laser-arc hybrid welding process. 10kW fiber laser source was combined to MIG arc welding process. API X-100 steel of base metal was of 16.9mm thickness, and butt welding applied. After welding, full penetration weld was acquired by 1-pass welding. A root porosity and the lack of fusion was observed in some welding conditions. By the mixing the melted wire, acicular ferrite, polygonal ferrite, pro-eutectoid, aligned side plate, and bainite structures were observed at the weld metal. From the observation of hybrid weld, unmixed zone had more Ni and Cr. The unmixed zone was a 1/3 area of the weld metal. As the mechanical test of the hybrid welding, tensile test and impact test applied. From the tensile test, all of the welding except SM70S was fractured at the base metal. The result of the impact test at -30 degree C led 60J~320J of the absorbed energy. The result of the low-absorbed energy might be from the coarse equiaxed structures of the weld metal.

모세관을 이용한 멀티형 열펌프의 신뢰성에 관한 실험적 연구 (An Experimental Stuff on the Performance of Multi-type Heat Pump using Capillary Tubes)

  • 권영철;장근선;이윤수;김대훈;전용호;이상재
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.749-755
    • /
    • 2002
  • In order to develop a multi-type heat pump system with two indoor units of non-uniform capacities, the optimum refrigerant circuit was developed using capillary tubes. The refrigerant circuit was composed of four main parts, a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The system characteristics of multi-type heat pump was investigated through the rating test and the reliability test, using the multi-type psy-chrometric calorimeter. The results of the rating test showed that the capacity of the multi-type heat pump was about 93% of the design value. In particular, the capacity of cooling single mode was about 13% higher than the design value, and the capacity of heating multi mode was about 5% higher than the design value. The reliability of the multi-type heat pump was verified by various reliability tests (overload, extension tube, freeze up, under/over charging, sweat, flood back). The optimal amount of refrigerant charge and compressor capacity were determined from the present work.