• Title/Summary/Keyword: pass-by method

Search Result 1,172, Processing Time 0.029 seconds

Application of Off-axis Correction Method for EPID Based IMRT QA (EPID를 사용한 세기조절방사선치료의 정도관리에 있어 축이탈 보정(Off-axis Correction)의 적용)

  • Cho, Ilsung;Kwark, Jungwon;Park, Sung Ho;Ahn, Seung Do;Jeong, Dong Hyeok;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.317-325
    • /
    • 2012
  • The Varian PORTALVISION (Varian Medical Systems, US) shows significant overresponses as the off-center distance increases compared to the predicted dose. In order to correct the dose discrepancy, the off-axis correction is applied to VARIAN iX linear accelerators. The portal dose for $38{\times}28cm^2$ open field is acquired for 6 MV, 15 MV photon beams and also are predicted by PDIP algorithm under the same condition of the portal dose acquisition. The off-axis correction is applied by modifying the $40{\times}40cm^2$ diagonal beam profile data which is used for the beam profile calibration. The ratios between predicted dose and measured dose is modeled as a function of off-axis distance with the $4^{th}$ polynomial and is applied to the $40{\times}40cm^2$ diagonal beam profile data as the weight to correct measured dose by EPID detector. The discrepancy between measured dose and predicted dose is reduced from $4.17{\pm}2.76$ CU to $0.18{\pm}0.8$ CU for 6 MV photon beam and from $3.23{\pm}2.59$ CU to $0.04{\pm}0.85$ CU for 15 MV photon beam. The passing rate of gamma analysis for the pyramid fluence patten with the 4%, 4 mm criteria is improved from 98.7% to 99.1% for 6 MV photon beam, from 99.8% to 99.9% for 15 MV photon beam. IMRT QA is also performed for randomly selected Head and Neck and Prostate IMRT plans after applying the off-axis correction. The gamma passing rare is improved by 3% on average, for Head and Neck cases: $94.7{\pm}3.2%$ to $98.2{\pm}1.4%$, for Prostate cases: $95.5{\pm}2.6%$, $98.4{\pm}1.8%$. The gamma analysis criteria is 3%, 3 mm with 10% threshold. It is considered that the off-axis correction might be an effective and easily adaptable means for correcting the discrepancy between measured dose and predicted dose for IMRT QA using EPID in clinic.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

A Study on the method of interpreting HoiJae Lee EonJeok's Daxue (회재(晦齋) 이언적(李彦迪)의 『대학(大學)』해석에 관한 연구)

  • Seo, Geun Sik
    • (The)Study of the Eastern Classic
    • /
    • no.34
    • /
    • pp.39-62
    • /
    • 2009
  • In this paper, the researcher investigated the standpoint of Lee EonJeok(李彦迪), also known as HoeJae(晦齋), with regard to interpretation of Daxue("大學"), through Daxuezhangjubuyi("大學章句補遺") and XuDaxuehuowen("續大學或問"). It is true that HoeJae accommodates a fairly large portion of interpretations made by Zhuzi, however, he strived to pass over Zhuzi's Daxuezhangju by attempting a new interpretation on the Gewuzhizhi(格物致知). The greatest reason that HoeJae couldn't admit Zhuzi's view was derived from the differences in interpretation of Gewuzhizhi. The differences between Zhuzi and HoeJae concerned with Gewuzhizhi is that, while Zhuzi perceived the objects thereof from the perspective of Li(理) of things(事物), HoeJae considered the root and branch, the beginning and end of the physical world(萬物) and also all events(萬事) as the subjects of Gewuzhizhi. Meanwhile, having the chapter, dubbed, 'Weyoubenmo'(物有本末), and the chapter, 'ZhiZhi'(知止) also as expositions of Gewuzhizhi, HoeJae was able to avoid such critiques as that he complemented or added new topics to the sutra. In addition, he could have clarified the stepwise elucidations of Sangangling(三綱領) and Batiaomu(八條目) edited and compiled by Zhuzi(朱子). And the issues in the chapter of Tingsong(聽訟) lies on the extended line of theory of Gewuzhizhi. In the end, it suggests that the differences between Zhuzi and HoeJae are arisen from the discrepancies of interpretation on Gewuzhizhi. HoeJae proposed his ideology concerned with Zhizhizhuyi(至治主義) through his book, XuDaxuehuowen, and he stressed that Ren(仁) must be foundation in order to Pingtianxia(平天下). Furthermore, HoeJae emphasized that Ren which is the founding virtue in order for Pingtianxia must be begun with such very basic behavioral practices, known as, Xiao(孝), Ti(弟), and Ci(慈), and that such desirable states would be accomplished through relationships with others, not merely through self-endeavors or by self-ego.

A Comparative Study on the Characteristics of Cultural Heritage in China and Vietnam (중국과 베트남의 문화유산 특성 비교 연구)

  • Shin, Hyun-Sil;Jun, Da-Seul
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.34-43
    • /
    • 2022
  • This study compared the characteristics of cultural heritage in China and Vietnam, which have developed in the relationship of mutual geopolitical and cultural influence in history, and the following conclusions were made. First, the definition of cultural heritage in China and Vietnam has similar meanings in both countries. In the case of cultural heritage classification, both countries introduced the legal concept of intangible cultural heritage through UNESCO, and have similarities in terms of intangible cultural heritage. Second, while China has separate laws for managing tangible and intangible cultural heritages, Vietnam integrally manages the two types of cultural heritages under a single law. Vietnam has a slower introduction of the concept of cultural heritage than China, but it shows high integration in terms of system. Third, cultural heritages in both China and Vietnam are graded, which is applied differently depending on the type of heritage. The designation method has a similarity in which the two countries have a vertical structure and pass through steps. By restoring the value of heritage and complementing integrity through such a step-by-step review, balanced development across the country is being sought through tourism to enjoy heritage and create economic effects. Fourth, it was confirmed that the cultural heritage management organization has a central government management agency in both countries, but in China, the authority of local governments is higher than that of Vietnam. In addition, unlike Vietnam, where tangible and intangible cultural heritage are managed by an integrated institution, China had a separate institution in charge of intangible cultural heritage. Fifth, China is establishing a conservation management policy focusing on sustainability that harmonizes the protection and utilization of heritage. Vietnam is making efforts to integrate the contents and spirit of the agreement into laws, programs, and projects related to cultural heritage, especially intangible heritage and economic and social as a whole. However, it is still dependent on the influence of international organizations. Sixth, China and Vietnam are now paying attention to intangible heritage recently introduced, breaking away from the cultural heritage protection policy centered on tangible heritage. In addition, they aim to unite the people through cultural heritage and achieve the nation's unified policy goals. The two countries need to use intangible heritage as an efficient means of preserving local communities or regions. A cultural heritage preservation network should be established for each subject that can integrate the components of intangible heritage into one unit to lay the foundation for the enjoyment of the people. This study has limitations as a research stage comparing the cultural heritage system and preservation management status in China and Vietnam, and the characteristic comparison of cultural heritage policies by type remains a future research task.

Compression Sensing Technique for Efficient Structural Health Monitoring - Focusing on Optimization of CAFB and Shaking Table Test Using Kobe Seismic Waveforms (효율적인 SHM을 위한 압축센싱 기술 - Kobe 지진파형을 이용한 CAFB의 최적화 및 지진응답실험 중심으로)

  • Heo, Gwang-Hee;Lee, Chin-Ok;Seo, Sang-Gu;Jeong, Yu-Seung;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.23-32
    • /
    • 2020
  • The compression sensing technology, CAFB, was developed to obtain the raw signal of the target structure by compressing it into a signal of the intended frequency range. At this point, for compression sensing, the CAFB can be optimized for various reference signals depending on the desired frequency range of the target structure. In addition, optimized CAFB should be able to efficiently compress the effective structural answers of the target structure even in sudden/dangerous conditions such as earthquakes. In this paper, the targeted frequency range for efficient structural integrity monitoring of relatively flexible structures was set below 10Hz, and the optimization method of CAFB for this purpose and the seismic response performance of CAFB in seismic conditions were evaluated experimentally. To this end, in this paper, CAFB was first optimized using Kobe seismic waveform, and embedded it in its own wireless IDAQ system. In addition, seismic response tests were conducted on two span bridges using Kobe seismic waveform. Finally, using an IDAQ system with built-in CAFB, the seismic response of the two-span bridge was wirelessly obtained, and the compression signal obtained was cross-referenced with the raw signal. From the results of the experiment, the compression signal showed excellent response performance and data compression effects in relation to the raw signal, and CAFB was able to effectively compress and sensitize the effective structural response of the structure even in seismic situations. Finally, in this paper, the optimization method of CAFB was presented to suit the intended frequency range (less than 10Hz), and CAFB proved to be an economical and efficient data compression sensing technology for instrumentation-monitoring of seismic conditions.

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

Left Ventricular Systolic Function Improvement after Surgical Revascularization in Postinfarction Angina (급성 심근 경색 후 협심증 환자에서의 관상동맥 우회술 후 좌심실 수축 기능의 호전)

  • Yi Gi-Jong;Park Seong-Yong;Hong You-Sun;Yoo Kyung-Jong;Chang Byung-Chul;Lim Sang-Hyun
    • Journal of Chest Surgery
    • /
    • v.39 no.9 s.266
    • /
    • pp.674-680
    • /
    • 2006
  • Background: Acute myocardial infarction (MI) is a life-threatening disease and surgical revascularization plays a major role in selected cases. The purpose of this study is to evaluate the left ventricular contractility improvement by examining the wall motion score index (WMSI) and left ventricular ejection fraction (LVEF) in patients who under-went surgical revascularization under diagnosis of acute MI. Material and Method: From January, 2001 to December, 2004, 149 patients who underwent coronary artery bypass surgery within 2 weeks of acute MI were included. We evaluated pre- and postoperative left ventricular contractility by measuring WMSI and LVEF and examined the associating factors. Result: WMSI decreased from $1.54{\pm}4.30\;to\;1.43{\pm}0.40$ (p<0.001) and LVEF increased from $48.1{\pm}12.2%\;to\;49.7{\pm}12.3%$ after surgery (p=0.009). Off-pump technique, non-Q wave, anterior MI, and surgery within 7 days after MI were favorable factors for LVEF improvement (p=0.046, p=0.006, p=0.003, p=0.005, respectively). Conversely, aforementioned factors were irrelevant with WMSI improvement. For triple vessel disease, complete revascularization was favorable factor for WMSI improvement (p<0.001). Conclusion: Coronary artery by-pass surgery can improve WMSI and LVEF in patients with acute MI. In case of anterior MI with non-Q wave, early surgical revascularization within 7 days may be most beneficial in LVEF improvement. Regarding WMSI, complete revascularization may be essential.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

The Comparative Studies on the Visitor Behavior based on Type and Scale of Urban Forest in Seoul - With a Special Reference to Bongje-san and Acha-san - (서울시 생활권 도시숲의 유형과 규모에 따른 이용행태 비교 연구 - 봉제산.아차산을 중심으로 -)

  • Kang, Eun-Jee;Hong, Jeong-Sik;Lee, Seul-Bee;Kim, Yong-Geun
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.1
    • /
    • pp.90-98
    • /
    • 2014
  • This study was carried out to provide basic data. his research conducted the survey using face to face survey and board survey during about 2 months from Oct. to Nov. in 2009 for users of Bongje Mt., a small-sized mountain at downtown, and Acha Mt., a big-sized mountain at outskirt so as to compare the differences of using behavior by forms and size of urban forest in living area of Seoul. Characteristics of urban forest users, using behavior, demands and satisfaction of facilities and management and pass pattern were set as research items. The thing in common for using behavior is that both genders of main users were in more than 40s~60s. They showed the highest using rate from 7 a.m. to 12 p.m. and high rate for using nearly everyday or visiting two or three times per a week. In addition, it's judged that the accessibility from dwelling area to entrance of urban forest in living area is good and satisfaction for the standard of facilities and their management in forest way was relatively low. For the complement and essential facilities, 'sanitary facilities' showed the highest rate. For the differences of using behavior, most of Bongje Mt. users were residents living within a 2km radius (under the standard of walking) and they moved by average 1.3km. And, they preferred short-time activities of about 24 minutes. On the other hand, main users of Acha Mt. were residents living within a 4km radius (under the standard of walking) and people of other regions. and 60% of them preferred the passage route taking 3hours half over 6km. Through the survey on using behavior of urban forest in living area of Seoul, with different using form and forest size, introduction of using program for main users or managing method of differentiations for introduced facility's management should be properly applied. Especially, urban forest should be systematically managed like park green as expected that residents's using of urban forest will be increased with the increase of leisure time.

Study on Development in Professional Work of Radiological Technologists (방사선사 업무의 발전에 관한 조사 연구)

  • Choi, Jong-Hak;Kim, Chang-Kyun;Kim, Won-Chul;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.197-210
    • /
    • 2006
  • This study explored several agenda related to license system, education, professional work of radiological technologists(RTs) and a transition process of law for them to investigate a developmental strategy of RTs as a professional career. The results are as followings : 1. The national license system for RTs was started from 1965, 1965-1972 x-ray technicians(medical assistance), 1973-present(2006) radiotechnologist(medical technologist) since then. 2. The average pass ratio of national license examination(1965-2006) for RTs was 46.6%. The method, subjects and level of the examination should be improved. 3. The education term for RTs has been changed since 1963 ; 1963-1990 two year college, 1991-1999 three year college, 2000-2006 four year and three year college depending on universities and colleges. As of 2006, there are twelve 4-year universities and eighteen 3-year colleges. The total number of new students were 1,956. 4. The new developmental paradigm should be made for technology education of RTs corresponding to the development of medicine and science. 5. The qualification system of clinical specialists in radio-technology field needs to be operated not by the non-governmental body(The Korean Radiological Technologists Association) but by the governmental body. 6. The vertical relationship among RTs, doctors and other medical workers should be rebuilt through the revision of law. Especially, doctors and dentists 'guidance authority' for RTs should be changed to 'request authority'. 7. The service extent of RTs should be extended in medical fields corresponding to professional work of RTs and a revision of the law needed for this situation.

  • PDF