• 제목/요약/키워드: partial test

검색결과 1,787건 처리시간 0.027초

저압 CVD에 의한 $Si_{0.8}Ge_{0.2}$ epitaxial growth에 대한 Phosphorus doping 효과 (Phosphorus doping effect on $Si_{0.8}Ge_{0.2}$ epitaxial growth by LPCVD)

  • 이철진;엄문종;성만영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.314-316
    • /
    • 1997
  • We have studied the epitaxial growth and electrical properties of $Si_{0.8}Ge_{0.2}$, films on Si substrates at $550^{\circ}C$ by LPCVD. In a low $PH_3$, partial pressure region such as below 1.25 mPa, the phosphorus doping concentration increased proportionally with increasing $PH_3$ partial pressure while the deposition rate and the Ge fraction x were constant. In a higher $PH_3$ partial pressure region, the phosphorus doping concentration and the deposition rate decreased, while the Ge fraction slightly increased. The dependence of P incorporation rate on the $PH_3$ partial pressure was similar to the phosphorus doping concentration. According to test results, it suggests that high surface coverage of phosphorus atoms suppress both the $SiH_4$ adsorption/reaction and the $GeH_4$ adsorption/reaction on the surfaces, and the effect is more stronger on $SiH_4$ than on $GeH_4$. In a higher $PH_3$ partial pressure region, the deposition is largely controlled by surface coverage effect of phosphorus atoms.

  • PDF

전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정 (Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage)

  • 김정태;김남준;이전선;구자윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

터널화재시 부분배연설비의 운영방안을 위한 수치해석적 연구 (A Numerical Study for the Operation of Partial Smoke Extraction System in Tunnel Fire)

  • 유용호;이의주;신현준;신한철
    • 한국화재소방학회논문지
    • /
    • 제20권2호
    • /
    • pp.72-79
    • /
    • 2006
  • 본 연구에서는 부분배연설비의 배연효율을 분석하고, 화재시 운영방안을 제시하기 위하여 수치해석을 실시하였다. 해석결과 선행된 실험을 통하여 얻었던 균일댐퍼의 배연효율 및 연기의 단면분포에 의한 성층화 결과는 서로 일치하는 경향을 얻을 수 있었다. 균일댐퍼의 운영방안은 화재시 화재 근방의 댐퍼만을 개방하였을 경우가 터널내 모든 댐퍼를 개방하였을 경우에 비하여 약 7%의 배연효율이 증가됨을 보였다. 또한, 터널내 차량이 정체시 화재가 발생할 경우 승객의 안전한 대피를 위한 부분배연설비의 정량적인 운전방안을 제안하였다.

가스센서를 이용한 부분방전특성에 따른 유중수소가스 측정연구 (Measurement Technology of the Dissolved Hydrogen Gas Due to Partial Discharge in Oil using Gas Sensor)

  • 허종철;선종호;강동식;정주영;추영배;박정후
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1784-1789
    • /
    • 2009
  • This paper describes the measurement technology of the dissolved hydrogen gas due to partial discharge in oil using gas sensor. For higher resolution and less error in measurement of the dissolved hydrogen gas in oil, the sensor outputs with ambient temperature which affect the sensor output characteristics should be considered. The sensor output trends with ambient temperature and the properties of the dissolved hydrogen gas in oil with partial discharge characteristic were analyzed through the test results. It was indicated that the sensor peak and the base voltage with measuring time were affected by ambient temperature and the measurement errors of the sensor output by temperature were reduced by using the difference between the peak and the base voltage rather than just the peak voltage. In addition, the hydrogen gas sensor outputs were increased with the increase of partial discharge energy.

곽향정기산가미방(藿香正氣散加味方) 투여 및 소장정격(小腸正格) 시술을 이용한 편평사마귀의 치료 효과 (Combination Therapy with Gwakhyangjeonggisangamibang and Sojangjeonggyeok for the Treatment of Verruca Plana)

  • 윤정민;신상호;윤화정;고우신
    • 한방안이비인후피부과학회지
    • /
    • 제23권1호
    • /
    • pp.169-181
    • /
    • 2010
  • Objective : The purpose of this study was to investigate the effects of Combination therapy with Gwakhyangjeonggisangamibang and Sojangjeonggyeok on patients with verucca plana. Methods : Sixty-five patients(male 19, female 46) with verruca plana were treated with Gwakhyangjeonggisangamibang and Sojangjeonggyeok for at least 3 months. After treatment, a clearance rate was divided into 4 scales such as; complete clearance / partial clearance-good / partial clearance-poor / no change. Statistical analysis was performed by using Independent-sample t-test. Results : Mean age of patients was 30.3 and mean period of disease duration was 64.6 months. Fifty-eight patients(73.8%) showed complete clearance, nine(13.8%) partial clearance-good, and eight(12.3%) partial clearance-poor. Complete clearance group(CC group) was statistically younger than failure group and disease duration of CC group was shorter than failure group. Although treatment period of failure group was statistically longer than CC group and dosage(貼) of herbal medicine of failure group was more than CC group, failure group showed partial clearance. Conclusion : This data demonstrates that combination therapy with Gwakhyangjeonggisangamibang and Sojangjeonggyeok could be an effective and safe treatment for the verucca plana.

Endocem MTA와 ProRoot MTA를 이용한 부분치수절단술 후 통증 발생에 관한 임상 연구 (Pain Occurrence after Partial Pulpotomy by using Endocem MTA and ProRoot MTA: a Clinical Study)

  • 곽상원;김현철
    • 대한치과의사협회지
    • /
    • 제57권1호
    • /
    • pp.18-25
    • /
    • 2018
  • Objectives: This study aimed to compare the postoperative pain and clinical performance after partial pulpotomy by using ProRoot MTA and Endocem MTA. Materials and Methods: Twenty-eight teeth requiring partial pulpotomy due to deep dental caries or traumatic injury were included in this study. After 2mm removal of exposed pulp and bleeding control, the ProRoot MTA or Endocem MTA was randomly adjusted to the exposed site. 1, 2, 4, and 12 weeks after the final restoration, the patients were recalled to check the postoperative pain or another unfavorable signs. Pearson's chi-square test was used for statistical analysis to evaluate any differences among tested materials. Results: 3 of 28 teeth showed postoperative pain and cold positive during follow-up period (10.7%). There were no statistically differences in pain occurrence between two tested materials (P > 0.05). Conclusions: In the limitations of this study, partial pulpotomy by using Endocem MTA showed the advantages of short setting time and lower postoperative pain incidence, allowing one visit treatment.

  • PDF

FES와 부분적인 체중지지를 결합한 지상보행훈련이 만성 뇌졸중 환자의 보행과 균형에 미치는 영향 (Effect of the Combined Use of FES and Over ground Walking with Partial Body-Weight Support on Walking and Balance Competency in Patients with Chronic Strokes)

  • 왕계석;윤세원;조운수;김용남
    • 대한임상전기생리학회지
    • /
    • 제10권1호
    • /
    • pp.15-22
    • /
    • 2012
  • Purpose : We investigated the effects of the combined use of FES and over ground walking with partial body-weight support (PBWS) on walking function and balance control in people with chronic strokes. Methods : Twenty-seven people who were ambulatory after chronic strokes were evaluated. The exercise's intervention consisted of the combined use of FES and over ground walking with PBWS and general exercise groups. The FES + PBWS group and general exercise group consisted on a-20-minute session per day, 3 times a week during a 4 week period. The evaluation was carried out before, after, and two weeks after the exercise intervention. Outcome measures were a 6 Minute Walk Test, 6-Meter walk Test, Timed Up and Go Test, and a Balance Test, measured before and after the exercise interventions at a-2 week follow up. Results : The endurance was significantly increased in both the FES+PBWS group and general exercise group (p<0.05). Significant increase on the gait velocity was observed in both the FES+PBWS group and general exercise group (p<0.05). The TUG was significantly different in both the FES + PBWS group and general exercise group (p<0.05). However there were no differences in both the between-group & interaction. The stability index was significantly different in both the FES + PBWS group and general exercise group (p<0.05). Conclusion : In conclusion, the combined use of FES and over ground walking with PBWS led to an improvement in walking function and balance control. Thus, it is possible to combine the use of FES and over ground walking with PBWS for physical therapy intervention to improve walking function and balance control. It is suggested to apply this intervention in the clinical field.

A New Directional Coupler Type Partial Discharge Sensor Installed on the Power Lead of Rotating Machine

  • Yi, Sang-Hwa;Hwang, Don-Ha;Park, Wee Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1769-1776
    • /
    • 2016
  • For on-line partial discharge (PD) monitoring of rotating machines, a novel sensor is proposed, which can be installed on the power lead inside the terminal box of the machine. The sensor has been designed to have high capacitance, and minimal reflection of measured pulses. As a sensitivity of the sensor, transfer impedance $Z_t$ has been measured and compared to conventional coupler-type sensors. A simple method is presented for measuring $Z_t$ of coupler sensors, using a vector network analyzer and a practical lead-cable of rotating machine. Through this method, it became possible to measure the $Z_t$ of coupler sensors including the installation environment of them. The $Z_t$ of the proposed sensor is higher than that of same sized other conventional couplers at frequencies between 30 and 92 MHz. Another sensitivity test has been performed using a PD calibrator as a test pulse source. The proposed sensor has higher measured peak voltage than the conventional coupler type sensors when the same charges were input.

부분분사 마이크로 축류형터빈에서의 익형각 효과에 관한 연구 (Effect of Blade Angles on a Micro Axial-Type Turbine Operated in a Low Partial Admission Rate)

  • 조수용;조봉수;조종현
    • 한국추진공학회지
    • /
    • 제11권4호
    • /
    • pp.10-18
    • /
    • 2007
  • 본 연구에 채택된 마이크로터빈은 축류형 터빈으로 2단으로 구성되어져 있으며 로터 유로에서의 평균반경이 8.4 mm이다. 이러한 소형 터빈은 마이크로 동력시스템의 드라이브로 사용되어질 수 있으며 무부하 상태에서 100,000 RPM의 회전속도에 도달한다. 하지만 낮은 부분분사에서 작동하므로 동익과 정익의 익형각에 따라 성능의 변화가 발생되어진다. 따라서 노즐, 정익, 동익의 익형각을 변경하면서 비출력과 총 비토오크를 측정하여 각각의 성능을 분석하였다. 성능실험의 결과에 의하면 동익 익형각의 변화에 따라 총 비토오크가 15%까지 변경되어졌으며 최적의 입사각은 $10.3^{\circ}$ 정도였다.

고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구 (A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine)

  • 오봉근;강동식;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF