• Title/Summary/Keyword: partial factor method

Search Result 287, Processing Time 0.036 seconds

Multiplex RT-PCR Assay for the Detection of Apple stem grooving virus and Apple chlorotic leaf spot virus in Infected Korean Apple Cultivars

  • Park, Hong-Lyeol;Yoon, Jae-Seung;Kim, Hyun-Ran;Baek, Kwang-Hee
    • The Plant Pathology Journal
    • /
    • v.22 no.2
    • /
    • pp.168-173
    • /
    • 2006
  • To develop the diagnostic method for the viral infection in apple, the partial genes corresponding to the N-terminal region of RNA polymerase of Apple stem grooving virus (ASGV) and coat protein of Apple chlorotic leaf spot virus (ACLSV) were characterized from the infected apple cultivars in Korea. Based on the nucleotide sequences of the characterized partial genes, the virus gene-specific primers were designed for the detection of ASGV and ACLSV infected in species of Malus. The RT-PCR using the primers for the genes of ASGV and ACLSV successfully gave rise to 404 and 566 bp DNA fragments, respectively. Using those viral gene-specific primers, the multiplex RT-PCR assays were also established to diagnose the mixed infection by ASGV and ACLSV simultaneously. Furthermore, the control primers, which have to be included for the RT-PCR as an internal control, were designed using the nucleotide sequence of the gene encoding elongation factor $1{\alpha}(EF1{\alpha})$. This multiplex RT-PCR including the control primers provides more reliable, rapid and sensitive assay for the detection of ASGV and ACLSV infected in Korean apple cultivars.

A Study on Development of High Voltage Mica Capacitors (고전압 마이카 커패시터 개발에 관한 연구)

  • Yun, Eui-Jung;Choi, Cheal-Soon;Kim, Jae-Wook;Lee, Dong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1229-1234
    • /
    • 2008
  • In this work, ultra high-voltage (17 - 50 kV AC), reliable 80 pF mica capacitors for partial discharge system application were investigated. Mica was used as the dielectric of the capacitors. Using the conservative design rule, over 3 individual $50\;{\mu}m$ thick mica sheets with a size of 30mm{\times}35mm were used with lead foils to form a parallel capacitor element and 20 mica sheets were interleaved with lead foils to form a series stack of parallel capacitor element to meet the requirements of the capacitors. The dimensions of the fabricated 80 pF capacitors for 17 kV AC and 50 kV AC were $90\;mm{\times}90\;mm$ and $95\;mm{\times}180\;mm$, respectively. The high-frequency characteristics of the capacitance (C) and dissipation factor (D) of the developed capacitors were measured using a capacitance meter. The developed capacitors exhibited C of 79.5 - 87.5 pF, had D of 0.001% over the frequency ranges of 150 kHz to 50 MHz, had a self-resonant frequency of 65 MHz, and showed results comparable to those measured for the capacitors prepared recently by $Adwel^{Tm}$. The developed capacitors also showed excellent characteristics for thermal shock test and temperature cycling test.

Determination of Human Skin Moisture in the Near-Infrared Region from 1100 to 2200 nm by Portable NIR System (1100∼2200 nm 파장 영역의 휴대용 근적외선 분광분석기를 이용한 사람피부의 수분측정)

  • 안지원;서은정;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.3
    • /
    • pp.148-153
    • /
    • 2003
  • Skin moisture is an important factor in skin health. Measurement of moisture content can provide diagnostic information on the condition of skin. In this study, a portable near-infrared (NIR) system was newly integrated with a photo diode array detector that has no moving parts, and this system has been successfully applied for the evaluation of human skin moisture. Diffuse reflectance spectra were collected and transformed to absorbance using 1 nm step size over the wavelength range of 1100 nm to 2200 nm. Partial least squares regression (PLSR) was applied to develop a calibration model. For practical use for the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo using the portable NIR system on the basis of the relative water content values of stratum corneum from the conventional capacitance method. The PLS model showed a good correlation. The calibration with the use of PLS model predicted human moisture with a standard error of prediction (SEP) of 3.5 at 1120∼1730 nm range. This study showed the possibility of skin moisture measurement using portable NIR system.

A study on the Adoptability of the Bo-Son Construction Method Based on Teachng Materials (교수 자료에 나타난 버선 제도의 적합성 연구)

  • 정옥임
    • Journal of the Korean Home Economics Association
    • /
    • v.34 no.2
    • /
    • pp.129-142
    • /
    • 1996
  • This paper pursues a comparative study on the design and function of the ready-made Bo-Son and the Bo-Son Pattern based on teaching and learning materials. It intends to investigate whether the Bo-Son is designed to suit to Kinetics of foot or to give the ease of wearing and taking off. The following results came out through trial wearing. 1) The Bo-Son pattern suggested in teaching materials can not satisfy the wearers with partial modification due to design problem. On the other hand, the ready-made Bo-Son can satisfy them with partial modification. 2) The important factor in designing the pattern of Bo-Son is the posture of foot when putting on it, that is, the height of the heel of the foot from the floor, the length of the heel, the length of toe and the bending angle of toe. 3) As a result of this study, in the design of the improved Bo-Son pattern, it is most suitable when the size of foot is 230mm, the height of the heel of the foot is 12.5cm, and and angle of the front toe of a sock is 35$^{\circ}C$.

  • PDF

Properties and classification of air discharge by Kohonen network (기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

The Effect of Sports Club Membership Lifestyle on Choice Behavior

  • Sunmun Park;Shuo LI
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.2
    • /
    • pp.267-275
    • /
    • 2023
  • The purpose of this study is to investigate the influence of sports center members' lifestyles on participation promotion and choice behavior. To this end, more specifically, we intend to establish and clarify a hypothetical model based on the preceding studies of facilitating factors and factors that continue to participate according to the lifestyle of sports center members. In order to achieve this research purpose, the study subjects were set as the population of male and female adults over 20 who are using sports centers in Gwangju Metropolitan City and Jeollanam-do in 2021. As for the sampling method, the sample was extracted using cluster random sampling, and 300 people were used for the actual analysis, excluding 60 copies of double-entry and insincere or unreliable questionnaires. The survey tool was modified and supplemented according to this study based on the questionnaire that had been verified for reliability and validity in previous studies, and all questionnaire items were composed of a 5-point scale. The statistical analysis used for data analysis was frequency analysis, exploratory factor analysis, reliability analysis, and multiple regression analysis using SPSS Windows 21.0 Version. The conclusions obtained in this study through data analysis by such methods and procedures are as follows. First, according to the lifestyle of sports center members, participation promotion factors were found to have a partial influence. Second, according to the lifestyle of sports center members, the selection behavior was found to have a partial influence. Third, it was found that the participation promotion factors of sports center members partially affected the choice behavior.

Optimal Selection of Master States for Order Reduction (동적시스템의 차수 줄임을 위한 주상태의 최적선택)

  • 오동호;박영진
    • Journal of KSNVE
    • /
    • v.4 no.1
    • /
    • pp.71-82
    • /
    • 1994
  • We propose a systematic method to select the master states, which are retained in the reduced model after the order reduction process. The proposed method is based on the fact that the range space of right eigenvector matrix is spanned by orthogonal base vectors, and tries to keep the orthogonality of the submatrix of the base vector matrix as much as possible during the reduction process. To quentify the skewness of that submatrix, we define "Absolute Singularity Factor(ASF)" based on its singular values. While the degree of observability is concerned with estimation error of state vector and up to n'th order derivatives, ASF is related only to the minimum state estimation error. We can use ASF to evaluate the estimation performance of specific partial measurements compared with the best case in which all the state variables are identified based on the full measurements. A heuristic procedure to find suboptimal master states with reduced computational burden is also proposed. proposed.

  • PDF

A Speech Enhancement Algorithm based on Human Psychoacoustic Property (심리음향 특성을 이용한 음성 향상 알고리즘)

  • Jeon, Yu-Yong;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1120-1125
    • /
    • 2010
  • In the speech system, for example hearing aid as well as speech communication, speech quality is degraded by environmental noise. In this study, to enhance the speech quality which is degraded by environmental speech, we proposed an algorithm to reduce the noise and reinforce the speech. The minima controlled recursive averaging (MCRA) algorithm is used to estimate the noise spectrum and spectral weighting factor is used to reduce the noise. And partial masking effect which is one of the human hearing properties is introduced to reinforce the speech. Then we compared the waveform, spectrogram, Perceptual Evaluation of Speech Quality (PESQ) and segmental Signal to Noise Ratio (segSNR) between original speech, noisy speech, noise reduced speech and enhanced speech by proposed method. As a result, enhanced speech by proposed method is reinforced in high frequency which is degraded by noise, and PESQ, segSNR is enhanced. It means that the speech quality is enhanced.

Novel high-Q veritcal inductor using bondwires for MMICs (본딩와이어를 이용한 MMIC용 고품질 수직형 인덕터)

  • 이용구;윤상기;이해영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.9
    • /
    • pp.28-35
    • /
    • 1997
  • A novel high-Q vertical jinductor for MMICs is proposed and characterized in a wide range of frequencies (DC~10 GHz) using the numerical methods such as the PeEC(partial equivalent element circuit), the FDM (finite difference method) and the MoM (method of moments). Electrical superiority of the vertical inductor to the horizontal is observed in terms of the magnetic flux linkage and the ground screening effect. The veritcal bondwire inductor is designed in consideration of the wire bonding feasibility and the optimum electrical peformance. This structure is also analyzed using the equivalent circuit and compared with the conventional spiral inductors From the calculated results, high Q-factor, inductance, and cut-off frequency are observed to be inherent characteristics of the veritcal bondwire inductor.

  • PDF

Nonlinear forced vibration of sandwich plate with considering FG core and CNTs reinforced nano-composite face sheets

  • Rostami, Rasoul;Rahaghi, Mohsen Irani;Mohammadimehr, Mehdi
    • Smart Structures and Systems
    • /
    • v.26 no.2
    • /
    • pp.185-193
    • /
    • 2020
  • Nonlinear vibration of sandwich plate with functionally graded material (FGM) core and carbon nano tubes reinforced (CNTs) nano-composite layers by considering temperature-dependent material properties are studied in this paper. Base on Classical plate theory (CPT), the governing partial differential equations of motion for sandwich plate are derived using Hamilton principle. The Galerkin procedure and multiple scales perturbation method are used to find relation between nonlinear frequency and amplitude of vibration response. The dynamic responses of the sandwich plate are also investigated in both time and frequency domains. Then, the effects of nonlinearity, excitation, power law index of FG core, volume fraction of carbon nanotube, the function of material variations of FG core, temperature changes, scale transformation parameter and damping factor on the frequency responses are investigated.