• Title/Summary/Keyword: parallel system

Search Result 4,288, Processing Time 0.028 seconds

Efficient DRAM Buffer Access Scheduling Techniques for SSD Storage System (SSD 스토리지 시스템을 위한 효율적인 DRAM 버퍼 액세스 스케줄링 기법)

  • Park, Jun-Su;Hwang, Yong-Joong;Han, Tae-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.7
    • /
    • pp.48-56
    • /
    • 2011
  • Recently, new storage device SSD(Solid State Disk) based on NAND flash memory is gradually replacing HDD(Hard Disk Drive) in mobile device and thus a variety of research efforts are going on to find the cost-effective ways of performance improvement. By increasing the NAND flash channels in order to enhance the bandwidth through parallel processing, DRAM buffer which acts as a buffer cache between host(PC) and NAND flash has become the bottleneck point. To resolve this problem, this paper proposes an efficient low-cost scheme to increase SSD performance by improving DRAM buffer bandwidth through scheduling techniques which utilize DRAM multi-banks. When both host and NAND flash multi-channels request access to DRAM buffer concurrently, the proposed technique checks their destination and then schedules appropriately considering properties of DRAMs. It can reduce overheads of bank active time and row latency significantly and thus optimizes DRAM buffer bandwidth utilization. The result reveals that the proposed technique improves the SSD performance by 47.4% in read and 47.7% in write operation respectively compared to conventional methods with negligible changes and increases in the hardware.

Quality of Working Life (직장생활에 대한 새로운 인식)

  • 김영환
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.43-61
    • /
    • 1981
  • Interest in the Quality of working life is spreading rapidly and the phrase has entered the popular vocabulary. That this should be so is probably due in large measure to changes in the values of society, nowadays accelerated as never before by the concerns and demands of younger people. But however topical the concept has become, there is very little agreement on its definition. Rather, the term appears to have become a kind of depository for a variety of sometimes contradictory meanings attributed to it by different groups. A list of all the elements it if held to cover would include availability and security of employment, adaquate income, safe and pleasant physical working conditions, reasonable hours of work, equitable treatment and democracy in the workplace, the possibility of self-development, control over one's work, a sense of pride in craftsmanship or product, wider career choices, and flexibility in matters such as the time of starting work, the number of working days in the week, Job sharing and so on altogether an array that encompasses a variety of traditional aspirations and many new ones reflecting the entry into the post industrial era. The term "quality of working life" was introduced by professor Louis E. Davis and his colleagues in the late 1960s to call attention to the prevailing and needlessly poor quality of life at the workplace. In their usage it referred to the quality of the relationship between the worker and his working environment as a whole, and was intended to emphasize the human dimension so often forgotten among the technical and economic factors in job design. Treating workers as if they were elements or cogs in the production process is not only an affront to the dignity of human life, but is also a serious underestimation of the human capabilities needed to operate more advanced technologies. When tasks demand high levels of vigilence, technical problem-solving skills, self initiated behavior, and social and communication skills. it is imperative that our concepts of man be of requisite complexity. Our aim is not just to protect the worker's life and health but to give them an informal interest in their job and opportunity to express their views and exercise control over everything that affects their working life. Certainly, so far as his work is concerned, a man must feel better protected but he must also have a greater feeling of freedom and responsibility. Something parallel but wholly different if happening in Europe, industrial democracy. What has happened in Europe has been discrete, fixed, finalized, and legalized. Those developing centuries driving toward industrialization like R.O.K, shall have to bear in mind the human complexity in processing and designing the work and its environment. Increasing attention is needed to the contradiction between autocratic rule at the workplace and democratic rights in society.n society.

  • PDF

Multi-Channel Analog Front-End for Auditory Nerve Signal Detection (청각신경신호 검출 장치용 다중채널 아나로그 프론트엔드)

  • Cheon, Ji-Min;Lim, Seung-Hyun;Lee, Dong-Myung;Chang, Eun-Soo;Han, Gun-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.60-68
    • /
    • 2010
  • In case of sensorineural hearing loss, auditory perception can be activated by electrical stimulation of the nervous system via electrode implanted into the cochlea or auditory nerve. Since the tonotopic map of the human auditory nerve has not been definitively identified, the recording of auditory nerve signal with microelectrode is desirable for determining the tonotopic map. This paper proposes the multi-channel analog front-end for auditory nerve signal detection. A channel of the proposed analog front-end consists of an AC coupling circuit, a low-power 4th-order Gm-C LPF, and a single-slope ADC. The AC coupling circuit transfers only AC signal while it blocks DC signal level. Considering the bandwidth of the auditory signal, the Gm-C LPF is designed with OTAs adopting floating-gate technique. For the channel-parallel ADC structure, the single-slope ADC is used because it occupies the small silicon area. Experimental results shows that the AC coupling circuit and LPF have the bandwidth of 100 Hz - 6.95 kHz and the ADC has the effective resolution of 7.7 bits. The power consumption per a channel is $12\;{\mu}W$, the power supply is 3.0 V, and the core area is $2.6\;mm\;{\times}\;3.7\;mm$. The proposed analog front-end was fabricated in a 1-poly 4-metal $0.35-{\mu}m$ CMOS process.

40Gb/s Foward Error Correction Architecture for Optical Communication System (광통신 시스템을 위한 40Gb/s Forward Error Correction 구조 설계)

  • Lee, Seung-Beom;Lee, Han-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.2
    • /
    • pp.101-111
    • /
    • 2008
  • This paper introduces a high-speed Reed-Solomon(RS) decoder, which reduces the hardware complexity, and presents an RS decoder based FEC architecture which is used for 40Gb/s optical communication systems. We introduce new pipelined degree computationless modified Euclidean(pDCME) algorithm architecture, which has high throughput and low hardware complexity. The proposed 16 channel RS FEC architecture has two 8 channel RS FEC architectures, which has 8 syndrome computation block and shared single KES block. It can reduce the hardware complexity about 30% compared to the conventional 16 channel 3-parallel FEC architecture, which is 4 syndrome computation block and shared single KES block. The proposed RS FEC architecture has been designed and implemented with the $0.18-{\mu}m$ CMOS technology in a supply voltage of 1.8 V. The result show that total number of gate is 250K and it has a data processing rate of 5.1Gb/s at a clock frequency of 400MHz. The proposed area-efficient architecture can be readily applied to the next generation FEC devices for high-speed optical communications as well as wireless communications.

B1+ Homogenizaion over Whole Field of View in High Field MRI (고자장 MRI에서의 영상 영역에 대한 B1+ 균질성)

  • Kim, Hong-Joon;Son, Hyeok-Woo;Cho, Young-Ki;Yoo, Hyoung-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.96-100
    • /
    • 2012
  • In high static field magnetic resonance imaging(MRI) systems, $B_0$ fields of 7 T and 9.4 T, the impressed RF field shows larger inhomogeneity than in clinical MRI systems with B0 fields of 1.5 T and 3.0 T. In multi-channel RF coils, the magnitude and phase of the input to each coil element can be controlled independently to reduce the non-uniformity of the impressed RF $B_1^+$ field. The convex optimization technique has been used to obtain the optimum excitation parameters with iterative solutions for homogeneity in a selected ROI(Region of Interest). To demonstrate the technique, the multichannel transmission line coil was modeled together with a human head phantom at 400 MHz for the 9.4 T MRI system and $B_1^+$ fields are obtained. In this paper, all the optimized $B_1^+$ in each isolated ROIs are combined to achieve significantly improved homogeneity over the entire field of view. The simulation results for 9.4 T MRI systems are discussed in detail.

Optimum Monitoring Parameters for the Safety of Mechanical Seals (미캐니컬 씰의 안전운용 감시를 위한 최적 계측인자)

  • Soon-Jae Lim;Man-Yong Choi
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.214-219
    • /
    • 1997
  • The mechanical seals, which are installed in rotating machines like pump and compressor, are generally used as sealing devices in the many fields of industries. The failure of mechanical seals such as leakage, crack, breakage, fast and severe wear, excessive torque, and squeaking results in big problems. To identify abnormal phenomena on mechanical seals and to propose the proper monitoring parameter for the failure of mechanical seals, sliding wear experiments were conducted. Acoustic emission, torque, and temperature were measured during experiments. Optical microstructure was observed for the wear processing after every 10 minute sliding at rotation speed of 1750 rpm and scanning electron microscopy was also observed. Except for the initial part of every experiment, the variation of acoustic emission was well coincided with torque variation during the experiments. This study concludes that acoustic emission and torque are proper monitoring parameters for the failure of mechanical seals. The intensity of acoustic emission signals is measured in root mean square voltage. Temperature of sealing face will be used as a parallel parameter for increasing the reliability of monitoring system.

  • PDF

Coordinated alteration of mRNA-microRNA transcriptomes associated with exosomes and fatty acid metabolism in adipose tissue and skeletal muscle in grazing cattle

  • Muroya, Susumu;Ogasawara, Hideki;Nohara, Kana;Oe, Mika;Ojima, Koichi;Hojito, Masayuki
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.11
    • /
    • pp.1824-1836
    • /
    • 2020
  • Objective: On the hypothesis that grazing of cattle prompts organs to secrete or internalize circulating microRNAs (c-miRNAs) in parallel with changes in energy metabolism, we aimed to clarify biological events in adipose, skeletal muscle, and liver tissues in grazing Japanese Shorthorn (JSH) steers by a transcriptomic approach. Methods: The subcutaneous fat (SCF), biceps femoris muscle (BFM), and liver in JSH steers after three months of grazing or housing were analyzed using microarray and quantitative polymerase chain reaction (qPCR), followed by gene ontology (GO) and functional annotation analyses. Results: The results of transcriptomics indicated that SCF was highly responsive to grazing compared to BFM and liver tissues. The 'Exosome', 'Carbohydrate metabolism' and 'Lipid metabolism' were extracted as the relevant GO terms in SCF and BFM, and/or liver from the >1.5-fold-altered mRNAs in grazing steers. The qPCR analyses showed a trend of upregulated gene expression related to exosome secretion and internalization (charged multivesicular body protein 4A, vacuolar protein sorting-associated protein 4B, vesicle associated membrane protein 7, caveolin 1) in the BFM and SCF, as well as upregulation of lipolysis-associated mRNAs (carnitine palmitoyltransferase 1A, hormone-sensitive lipase, perilipin 1, adipose triglyceride lipase, fatty acid binding protein 4) and most of the microRNAs (miRNAs) in SCF. Moreover, gene expression related to fatty acid uptake and inter-organ signaling (solute carrier family 27 member 4 and angiopoietin-like 4) was upregulated in BFM, suggesting activation of SCF-BFM organ crosstalk for energy metabolism. Meanwhile, expression of plasma exosomal miR-16a, miR-19b, miR-21-5p, and miR-142-5p was reduced. According to bioinformatic analyses, the c-miRNA target genes are associated with the terms 'Endosome', 'Caveola', 'Endocytosis', 'Carbohydrate metabolism', and with pathways related to environmental information processing and the endocrine system. Conclusion: Exosome and fatty acid metabolism-related gene expression was altered in SCF of grazing cattle, which could be regulated by miRNA such as miR-142-5p. These changes occurred coordinately in both the SCF and BFM, suggesting involvement of exosome in the SCF-BFM organ crosstalk to modulate energy metabolism.

STN DBS of Advanced Parkinson's Disease Experienced in a Specialized Monitoring Unit with a Prospective Protocol

  • Lee, Ji-Yeoun;Han, Jung-Ho;Kim, Han-Joon;Jeon, Beom-Seok;Kim, Dong-Gyu;Paek, Sun-Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.26-35
    • /
    • 2008
  • Objective : In the evaluation of patients with Parkinson's disease (PD), most neurologists only see their patients during a limited period of their fluctuating 24-hour-a-day lives. This study aimed to assess the short-term outcome of STN stimulation for patients with advanced PD evaluated in a 24-hour monitoring unit for movement disorder (MUMD) using a prospective protocol. Methods : Forty-two patients with advanced PD consecutively treated with bilateral STN stimulation using multi-channel microelectrode recording were included in this study. All patients were evaluated using a 24-hour MUMD with a video recording/editing system and were evaluated with a prospective protocol of the Unified Parkinson's Disease Rating Scale, Hoehn and Yahr Staging, Schwab and England Activities of Daily Living, levodopa equivalent daily dose (LEDD), Short Form-36 Health Survey, and neuropsychological tests. Magnetic resonance (MR) images of the brain were performed prior to and six months after surgery. Results : All patients were evaluated at three and six months after surgery. There was a rapid and significant improvement of the motor symptoms, especially in tremor and rigidity, after STN stimulation with low morbidity. Dyskinesia was markedly decreased with much lowered LEDD values by 50% after STN stimulation. 1.5T MR images were safely taken according to the manufacturer's guidelines at six months after surgery without any adverse effects in 41 patients treated with STN stimulations. Conclusion : Evaluations in a 24-hour monitoring unit could reduce the dose of medication efficiently to an optimal level with patients' comfort and improve the clinical symptoms in harmony with STN stimulation.

Mathematician Taylor's Linear Perspective Theory and Painter Kirby's Handbook (수학자 테일러의 선 원근법과 화가 커비의 해설서)

  • Cho, Eun-Jung
    • The Journal of Art Theory & Practice
    • /
    • no.7
    • /
    • pp.165-188
    • /
    • 2009
  • In the development of linear perspective, Brook Taylor's theory has achieved a special position. With his method described in Linear Perspective(1715) and New Principles of Linear Perspective(1719), the subject of linear perspective became a generalized and abstract theory rather than a practical method for painters. He is known to be the first who used the term 'vanishing point'. Although a similar concept has been used form the early stage of Renaissance linear perspective, he developed a new method of British perspective technique of measure points based on the concept of 'vanishing points'. In the 15th and 16th century linear perspective, pictorial space is considered as independent space detached from the outer world. Albertian method of linear perspective is to construct a pavement on the picture in accordance with the centric point where the centric ray of the visual pyramid strikes the picture plane. Comparison to this traditional method, Taylor established the concent of a vanishing point (and a vanishing line), namely, the point (and the line) where a line (and a plane) through the eye point parallel to the considered line (and the plane) meets the picture plane. In the traditional situation like in Albertian method, the picture plane was assumed to be vertical and the center of the picture usually corresponded with the vanishing point. On the other hand, Taylor emphasized the role of vanishing points, and as a result, his method entered the domain of projective geometry rather than Euclidean geometry. For Taylor's theory was highly abstract and difficult to apply for the practitioners, there appeared many perspective treatises based on his theory in England since 1740s. Joshua Kirby's Dr. Brook Taylor's Method of Perspective Made Easy, Both in Theory and Practice(1754) was one of the most popular treatises among these posterior writings. As a well-known painter of the 18th century English society and perspective professor of the St. Martin's Lane Academy, Kirby tried to bridge the gap between the practice of the artists and the mathematical theory of Taylor. Trying to ease the common readers into Taylor's method, Kirby somehow abbreviated and even omitted several crucial parts of Taylor's ideas, especially concerning to the inverse problems of perspective projection. Taylor's theory and Kirby's handbook reveal us that the development of linear perspective in European society entered a transitional phase in the 18th century. In the European tradition, linear perspective means a representational system to indicated the three-dimensional nature of space and the image of objects on the two-dimensional surface, using the central projection method. However, Taylor and following scholars converted linear perspective as a complete mathematical and abstract theory. Such a development was also due to concern and interest of contemporary artists toward new visions of infinite space and kaleidoscopic phenomena of visual perception.

  • PDF

THE SHEAR BOND STRENGTH BETWEEN DICOR AND SEVERAL VENEERING PORCELAINS (Dicor와 수종 전장도재간의 전단결합강도)

  • Ryoo, Kyung-Hee;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.165-179
    • /
    • 1993
  • Dicor has not been prescribed routinely, in spite of many advantages, because of esthetic limitations by excessive translucency and external shading. In an attempt to solve these problems, the technique of veneering Dicor by aluminous poreclain has been used and recently Dicor Plus system was developed. The purpose of this study was to evaluate the compatibility between Dicor and several veneering porcelains by measuring the shear bond strength and observing the failure mode and interface appearance with SEM. Total 55 Dicor disks(10.0mm diam. X 3.0mm thickness) were fabricated by lost wax technique and divided into five groups of 11. Veneering porcelains such as Dicor Plus, Vitadur Alpha, Vitadur N, Vivodent, and Ceramco II were built up over the center of the treated Dicor surface using paper tube(5.0mm diam. X 4.0mm height) and fired according to the manufacturesr’instructions. A representative sample from each group was completely embedded in epoxy resin and crosssectioned, and remaining 50 samples were embedded in epoxy resin with the bonded area perpendicular to table base. The shear bond strengths were measured by applying the shear load parallel to Dicor surface close to the bonded area. Failure modes and interface appearances were observed using SEM at 15 and 1000 magnification respectively. The obtained results were as follows : 1. The mean shear bond strengths showed Dicor-Dicor Plus(10.53 MPa); Dicor-Vitadur Alpha(8.84 MPa); Dicor-Vitadur N(7.37 MPa); Dicor-Vivodent(4.28 MPa); Dicor-Ceramco II(0.89 MPa). 2. The shear bond strength of Dicor-CeramcoII was significantly decreased compared with Dicor-Dicor Plus(p<0.01), but had no significant difference compared with Dicor-Vivodent(p>0.01). 3. The shear bond strengths of Dicor-Vitadur Alpha and Dicor-Vitadur N were not significantly different compared with Dicor-Dicor Plus(p>0.01). 4. SEM examination of bond failure modes revealed that Dicor-Dicor plus, Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited cohesive failure within Dicor and Dicor-Vivodent exhibited adhesive failure. And Dicor-Ceramco III exhibited adhesive failure and cohesive failure within CeramcoIII together. 5. SEM examination of interfaces revealed that Dicor-Dicor Plus exhibited the most tight contact and Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited acceptible contacts. But Vivodent exhibited discontinuous gap and Ceramco II exhibited large continuous gap.

  • PDF