• Title/Summary/Keyword: parallel collection

Search Result 107, Processing Time 0.027 seconds

Study on improvement of submicron particle collection performance in 2-stage parallel-plate electrostatic precipitators (2단 평행판 전기집진기의 서브마이크론입자 집진성능 개선 연구)

  • Yoo, K.H.;Oh, M.D.;Lee, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.323-332
    • /
    • 1997
  • It was reported by some researchers that two-stage parallel-plate ESPs, commonly called electronic air cleaners, show decreasing behavior of collection efficiency as particle size decreases below about $0.03{\mu}m$. This phenomenon is attributed to partial particle charging characteristics, where some of incoming particles are not charged in the charging cell of 2-stage parallel-plate ESP. One way to improve the decreasing collection efficieny in that particle size range is to enforce particle charging quantity in the charging cell. In the present study, in order to do this a 2-wire series-type charging cell modified from a 1-wire normal-type one was suggested and investigated theoretically and experimentally concerning improvement of the collection efficiency. It was confirmed from the experimental and theoretical works that the collection efficiency was apparently improved.

  • PDF

Implementation of high-speed parallel data transfer for MCG signal acquisition (심자도 신호 획득을 위한 고속 병렬 데이터 전송 구현)

  • Lee, Dong-Ha;Yoo, Jae-Tack
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.444-447
    • /
    • 2004
  • A heart diagnosis system adopts hundreds of Superconducting Quantum Interface Device(SQUID) sensors for precision MCG(Magnetocardiogram) or MEG(Magnetoencephalogram) signal acquisitions. This system requires correct and real-time data acquisition from the sensors in a required sampling interval, i.e., 1 mili-second. This paper presents our hardware design and test results, to acquire data from 256 channel analog signal with 1-ksample/sec speed, using 12-bit 8-channel ADC devices, SPI interfaces, parallel interfaces, and 8-bit microprocessors. We chose to implement parallel data transfer between microprocessors as an effective way of achieving such data collection. Our result concludes that the data collection can be done in 250 ${\mu}sec$ time-interval.

  • PDF

Optimization of Data Acquisition System with Parallel Collection for PET

  • Yoshida, Eiji;Shimizu, Keiji;Murayama, Hideo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.311-313
    • /
    • 2002
  • We are under development of a 3D PET scanner with depth of interaction (DOI) capable of high sensitivity and high resolution. In this scanner, a maximum data transfer rate of coincidence pair's event information is 10 Mcps and one event is a 64-bit data format. This maximum data transfer rate corresponds by 10 times a conventional PET scanner. A data acquisition system, which fulfills the specification of this scanner, is considered for parallel collection with banks including several coincidence units. Data transfer rate is improved by optimizing parameters of a message size, and so on.

  • PDF

Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators (2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험)

  • Oh, M.D.;Yoo, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF

Particle Charging and Collection in Two-Stage, Parallel-Plate Electrostatic Precipitators (2단 평행판 정전식 집진기에서의 입자하전 및 포집)

  • 오명도;유경훈;이준식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.432-445
    • /
    • 1994
  • From a theoretical analysis point of view, the 2-stage precipitator is decomposed into two units: charging cell and collecting cell. Collection efficiency predictions of the two-stage parallel-plate electrostatic precipitator have been performed theoretically incorporating with the charging and the collecting cells. Particle trajectorise passing the charging cell have been modeled as a simple one. Particle charge distribution at the outlet of the charging cell is calculated through integration of the present unipolar combined charging rate along the entire particle trajectory, and average charge of particles at the outlet of the charging cell is obtained from the particle charge distribution. As for the collecting cell, the diminution of particle concentration along the longitudinal direction of the collecting cell is investigated considering the conventional Deutsch's theory and the laminar theory. One should note that the collection efficiency formula derived is based on monodisperse aerosols. It has been confirmed through the analysis that predictions of particle charge by applying White's unipolar diffusion charging theory overpredict actual cases in the continuum regime, while predictions by Fuch's unipolar diffusion charging theory indicate the reasonable result in the same regime. Theoretical predictions of collection efficiency are also compared with the available experimental results. Comparisons show that the experimental results are consistently located in the collection efficiency region bounded by the two limits, the Deutsch and the laminar collection efficiencies. Finally design parameters of the 2-stage electrostatic precipitator have been investigated systematically through the one-variable-at-a-time method in terms of collection efficiency. Applied voltages on the corona wire of the charging cell and the plate of the collecting cell, and the average air velocity have been selected as the design parameters.

The Effect of Cyclone Vortex Finder Configurations on the Fine Particle Collection Efficiencies (사이클론 선회류 약화기 구조에 따른 미세먼지 집진효율 연구)

  • Jeong, Dong Gyun;Kim, Beom Seok;Hong, Min Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.6
    • /
    • pp.371-376
    • /
    • 2017
  • The effect of vortex finder confiqurations on the PM-10 collection efficiencies has been investigated using 7 different types of cyclones. Cyclone inlet velocities were calculated by computational fluid dynamics analysis and PM-10 collection efficiencies were measured from experimental apparatus. The inlet velocities of normal, P and A type cyclones were calculated 15.48 m/sec, 16.03 m/sec and 15.9 m/sec, respectively while experimental results show that PM-10 collection efficiencies were increased 4% for P type and 7% for A type cyclones compared to normal cyclone. Also it was found that there exist optimum parallel head lengths for both P and A type cyclones to maximize the PM-10 collection efficiencies.

Design Method of a Parallel Feedforward Compensator for Passivation of Linear Systems (선형 시스템 수동화를 위한 병렬 앞먹임 보상기 설계방법 연구)

  • 손영익
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.7
    • /
    • pp.590-596
    • /
    • 2004
  • A passivity-based dynamic output feedback controller design is considered for a finite collection of non-square linear systems. Design of a single controller for a set of plants i.e. simultaneous stabilization is an important issue in the area of robust control design. We first determine a squaring gain matrix and an additional dynamics that is connected to the systems in a feedforward way, then a static passivating control law is designed. Consequently, the actual feedback controller will be the static control law combined with the feedforward dynamics. A necessary and sufficient condition for the existence of the parallel feedforward compensator is given by the static output feedback formulation. In contrast to the previous result [1], a technical condition for constructing the parallel feedforward compensator is removed by proposing a new type of the parallel compensator.

PDFindexer: Distributed PDF Indexing system using MapReduce

  • Murtazaev, JAziz;Kihm, Jang-Su;Oh, Sangyoon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.4 no.1
    • /
    • pp.13-17
    • /
    • 2012
  • Indexing allows converting raw document collection into easily searchable representation. Web searching by Google or Yahoo provides subsecond response time which is made possible by efficient indexing of web-pages over the entire Web. Indexing process gets challenging when the scale gets bigger. Parallel techniques, such as MapReduce framework can assist in efficient large-scale indexing process. In this paper we propose PDFindexer, system for indexing scientific papers in PDF using MapReduce programming model. Unlike Web search engines, our target domain is scientific papers, which has pre-defined structure, such as title, abstract, sections, references. Our proposed system enables parsing scientific papers in PDF recreating their structure and performing efficient distributed indexing with MapReduce framework in a cluster of nodes. We provide the overview of the system, their components and interactions among them. We discuss some issues related with the design of the system and usage of MapReduce in parsing and indexing of large document collection.

Performance Tests on Parallel Plate Type Solar Air Heater (공기식 평행판형 태양집열기 성능실험)

  • Cha Jong Hee;Song Hi Yul
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.6 no.4
    • /
    • pp.255-261
    • /
    • 1977
  • This study was concerned with the performance of solar air heater using parallel channels. Heat transmission model was developed and fabricated to increase the economic feasibility for solar heating system by using the cheap zinc plate. The prformance was discussed as a function of mass flow rate, and plate, inlet and outlet temperatures. Experimental results show that heat transmission model is sufficient for the analysis of thermal characteristics of air heater and collection efficiency is better than the domestic water heater, as the range 32-49 percent. Collection efficiency in the 2 layers of glass cover is better than that in 1 layer, so it is considered better to use the 2 layers of glass cover during the cold winter season in Korea.

  • PDF

A Study on the Performance Test of Axial-flow Cyclone Separator (축상유입식 사이클론 집진기 성능시험에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.1
    • /
    • pp.101-106
    • /
    • 2020
  • Along with dust collection efficiency, pressure loss is a very important cyclone operation factor. A severe rise in pressure loss causes the problem of cost. To solve the problem, the method connecting axial-vane type cyclones in parallel is suggested recently. The axial vane type cyclone dust collector applied in this study is a small portable type. Multiple cyclones are installed in a round type. The basic performance test on the axial vane type cyclone dust collector was conducted. As a result, the cut size reduced along with a rise in the wind velocity of the cyclone dust collector inlet. According to the test on dust collection efficiency, the effect of dust collection began to appear in the range of 3㎛ and dust collection efficiency was greatly improved at 5 ㎛. The noise of the cyclone dust collector well met the fan sound power level of KSB 6361.