• Title/Summary/Keyword: paper break

Search Result 785, Processing Time 0.023 seconds

A Performance Improvement Method using Variable Break in Corpus Based Japanese Text-to-Speech System (가변 Break를 이용한 코퍼스 기반 일본어 음성 합성기의 성능 향상 방법)

  • Na, Deok-Su;Min, So-Yeon;Lee, Jong-Seok;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.155-163
    • /
    • 2009
  • In text-to-speech systems, the conversion of text into prosodic parameters is necessarily composed of three steps. These are the placement of prosodic boundaries. the determination of segmental durations, and the specification of fundamental frequency contours. Prosodic boundaries. as the most important and basic parameter. affect the estimation of durations and fundamental frequency. Break prediction is an important step in text-to-speech systems as break indices (BIs) have a great influence on how to correctly represent prosodic phrase boundaries, However. an accurate prediction is difficult since BIs are often chosen according to the meaning of a sentence or the reading style of the speaker. In Japanese, the prediction of an accentual phrase boundary (APB) and major phrase boundary (MPB) is particularly difficult. Thus, this paper presents a method to complement the prediction errors of an APB and MPB. First, we define a subtle BI in which it is difficult to decide between an APB and MPB clearly as a variable break (VB), and an explicit BI as a fixed break (FB). The VB is chosen using the classification and regression tree, and multiple prosodic targets in relation to the pith and duration are then generated. Finally. unit-selection is conducted using multiple prosodic targets. In the MOS test result. the original speech scored a 4,99. while proposed method scored a 4.25 and conventional method scored a 4.01. The experimental results show that the proposed method improves the naturalness of synthesized speech.

Analysis of Vibration and Its Break Efficiency Due to Focal Position Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter (압전식 ESWL장치를 사용한 대상물 진동시 초점위치에 따른 진동 및 파쇄효율의 분석)

  • 장윤석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.186-189
    • /
    • 2000
  • In this paper, the relation between the vibration and the sound radiated due to the piezoelectric ESWL (Extra-corporeal Shock Wave Lithotripter) is examined And the relation between the focus and the vibration of the objects is examined. The same experiments with the objects that can be breton are done and the relation between the vibration and the break efficiency of the phantom is experimentally investigated. These results show that the relativity between the power of the peak frequency and the break efficiency can be confirmed.

  • PDF

Assessment of over / under-break of tunnel utilizing BIM and 3D laser scanner (3차원 레이저 스캐너 및 BIM을 활용한 터널 과대.과소 굴착 평가)

  • Park, Jeong-Jun;Shin, Jae-Chou;Hwang, Ju-Hwan;Lee, Kang-Hyun;Seo, Hyung-Joon;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.4
    • /
    • pp.437-451
    • /
    • 2012
  • Application of 3D laser scanner to civil engineering is widely studied in various fields such as tunnel, bridge, calculation of earth volume, construction measurement, observation of rock joint, etc. Some studies on utilization of the 3D laser scanner for calculating the over-break and/or under-break of tunnels have also been carried out. However, in the previous research, the scanning data were usually compared with the 2D CAD blueprint results; although the shape of tunnel structure is relatively simple, for precise calculation of the over-break and/or under-break of tunnels, three-dimensional analysis based on BIM is needed. Therefore, in this paper, a new program that calculates the over-break and/or under-break of tunnels using the 3D laser scanner and the BIM is developed; moreover the effective and rapid process of data treatment is proposed. The accuracy of the developed program was verified by applying the new system to a real tunnels construction field.

The Effects of Short Break Time and Mouse Clicks on the VDT Work by using Subjective Discomfort (VDT 작업시 짧은 휴식시간과 마우스 클릭이 주관적 불편도에 미치는 영향에 관한 연구)

  • Kim, Yu-Chang;Lee, Jun-Pal
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.30-36
    • /
    • 2008
  • This paper suggests the best work conditions, including short break time and number of mouse clicks on a computer, to prevent MSDs(Musculoskeletal Disorders) on VDT(Visual Display Terminal) work. Discomfort measures are calculated according to the Borg's CR-10 Scale. The short break time conditions are grouped into 7, 15, and 30 seconds after every 10-minute work period and the number of mouse clicks are divided into 10 clicks/min, 20clicks/min, and 30clicks/min. The result of the ANOVA on the shift value of subjective discomfort shows the following: 1) Regarding the break time and the number of mouse clicks, there are statistical differences between the measured values for the neck and the wrist(p<0.05). 2) Regarding the number of mouse clicks, there are statistical differences between the measured values for the shoulder and the forearm(p<0.1). 3) Regarding the break time and the number of mouse clicks, there are no statistical differences between the measures values for the eyes, upper arms and back(p<0.1).

A Study on the Short Break Time on VDT Work using EMG (근전도를 이용한 VDT 작업시 짧은 휴식시간에 관한 연구)

  • Kim, Yu-Chang;Lee, Jun-Pal
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.41-47
    • /
    • 2007
  • This paper suggested the best work conditions including short break time and the number of mouse clicks on the computer work for the prevention of MSDs on VDT work. Fatigue measures included EMG based parameters. The short break time conditions are grouped into 7, 15, and 30 seconds after every work for 10 min and the number of mouse clicks are divided into 10, 20, and 30 clicks/min. The result of the ANOVA of the shift value of %MVC(Maximum Voluntary Contraction) showed the following: 1) There was a considerable difference as regards to the break time except the number of mouse clicks on the upper trapezius muscle(p$<$0.05). The best conditions were shown in 15 sec after every 10 min and 30 clicks/min. 2) There were considerable differences as regards to the number of mouse clicks except the break time on the extensor digitorum muscle and extensor carpi ulnaris muscle(p$<$0.05). The best conditions were shown in 7 sec after every 10min and 10 clicks/min.

Realistic Large Break Loss of Coolant Accident Mass and Energy Release and Containment Pressure and Temperature Analyses

  • Kwon, Young-Min;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.229-239
    • /
    • 1997
  • To investigate the realistic behavior of mass and energy release and resultant containment response during large break Loss of Coolant accident (LOCA), analyses are performed for Yonggwang (YGN) 3&4 nuclear power plants by using a merged version of RELAP5/CONTEMPT4 computer code. Comparative analyses by using conservative design computer codes are also peformed. The break types analyzed are the double-ended guillotine breaks at the cold leg and hot leg. The design analysis resulted in containment peak pressure during post-blowdown phase for the cold leg break. However, the RELAP5/CONTEMPT4 analyses show that the containment pressure has a peak during blowdown phase, thereafter it decreases monotonously without the second port-blowdown peak. For the hot leg break, revised design analysis shows much lower pressure than that reported in YGN 3&4 final safety analysis report. The RELAP5/CONTEMPT4 analysis shoos similar trend and confirmed that the bypass flow through the broken loop steam generator during post-blowdown is negligibly small compared to that of cold leg break. The low pressure and temperature predicted tv realistic analysis presented in this paper suggest that the design analysis methodology contains substantial margin and it can be improved to provide benefit in investment protection, such as, relaxing plant technical specifications and reducing containment design pressure.

  • PDF

Improvements on Phrase Breaks Prediction Using CRF (Conditional Random Fields) (CRF를 이용한 운율경계추성 성능개선)

  • Kim Seung-Won;Lee Geun-Bae;Kim Byeong-Chang
    • MALSORI
    • /
    • no.57
    • /
    • pp.139-152
    • /
    • 2006
  • In this paper, we present a phrase break prediction method using CRF(Conditional Random Fields), which has good performance at classification problems. The phrase break prediction problem was mapped into a classification problem in our research. We trained the CRF using the various linguistic features which was extracted from POS(Part Of Speech) tag, lexicon, length of word, and location of word in the sentences. Combined linguistic features were used in the experiments, and we could collect some linguistic features which generate good performance in the phrase break prediction. From the results of experiments, we can see that the proposed method shows improved performance on previous methods. Additionally, because the linguistic features are independent of each other in our research, the proposed method has higher flexibility than other methods.

  • PDF

Improving Regenerative Break Energy Efficiency and Voltage Regulation Capability of DC Electric Railway by Coordination of VSC and EDLC (전압형 컨버터와 EDLC의 협조 제어에 의한 직류전기철도 회생에너지 이용률 및 전압 제어 능력 향상)

  • Jeon, Go-Woon;Yoo, Hyeong-Jun;Park, Jae-Sae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.176-181
    • /
    • 2015
  • In the DC electric railway system, the effective use of regenerative break energy is an important issue. Since regenerative break energy causes voltage rise or drop in the system, it should be also solved effectively. To solve the problems, applying electric double layer capacitor (EDLC) or voltage source converter (VSC) to the DC electric railway system has been studying. In this paper, the coordination of EDLC and VSC is proposed to solve the problem effectively with its coordinated control algorithm. The proposed method is tested to show its feasibility using Matlab/Simulink.

Study on the Synthesis of Wool-blending Fiber Bundle and New Signs of the Curve

  • Ren Yonghua;Yu Jianyong
    • Fibers and Polymers
    • /
    • v.6 no.4
    • /
    • pp.339-342
    • /
    • 2005
  • In this paper, a hand-operating method (tiled test method) of the wool-blending sample is made out, and make use of the method, the test of wool-blending bundle in different blending ratio is accomplished. According to the test data, the synthesis method of the stretch curve is worked out and the synthesis software for the typical stretch curve of wool-blending bundle is designed. Through laboratory hand-operating method, the blending fasciculus applying to fiber bundle test can be obtained in a short time. Calculation for sampling is accomplished in the article. We bring up 9 new signs to describe the characteristics of the curve behind peak for the first time: elongation behind peak (HE), elongation percentage behind peak (HEP), relative elongation rate behind peak (RHE), total break work $(W_a)$, break work behind peak (HW), break work coefficient behind peak (HWC), elongation percentage of half-load behind peak (HEL), load percentage of half-elongation behind peak (HLE), break efficiency behind peak (HEC).

Accelerated life test of SF_6 gas load break switch for overhead line (가공용 가스절연부하개폐기 가속수명시험)

  • Park Seung Jae;Heo Jong Chul;Kim Maeng Hyun;Koh Heui Seog
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.551-553
    • /
    • 2004
  • SF_6 gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, with these trends, SF_6 load break switches have rapidly substituted for the air or oil-type load break switches, in order to get higher reliability. And, the national standard was made for reliability assessment of SF_6 gas load break switch and testing facilities was also set in KERI(Korea Electrotechnology Research Institute ). This paper introduces the synopsis for the reliability assessment requirements specified in the standard and the assessment results.

  • PDF