• Title/Summary/Keyword: pad design

Search Result 561, Processing Time 0.031 seconds

Design of a 48MHz~1675MHz Frequency Synthesizer for DTV Tuners (DTV 튜너를 위한 48MHz~1675MHz 주파수합성기 설계)

  • Ko, Seung-O;Seo, Hee-Teak;Kwon, Duck-Ki;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.5
    • /
    • pp.1125-1134
    • /
    • 2011
  • In this paper a wideband frequency synthesizer is designed for DTV tuners using a $0.18{\mu}m$ CMOS process. It satisfies the DTV frequency band(48~1675MHz). A scheme is proposed to cover the full band using only one VCO and reliable broadband characteristics are achieved by reducing the variations of VCO gains and frequency steps. The simulation results show that the designed VCO has frequency range of 1.85~4.22GHz, phase noise at 4.22GHz of -89.7dBc/Hz@100kHz, gains of 62.4~95.8MHz/V(${\pm}21.0%$) and frequency steps of 22.9~47.9MHz(${\pm}35.3%$). The designed VCO has a phase noise of -89.75dBc/Hz at 100kHz offset. The designed synthesizer has a lock time less than $0.15{\mu}s$. The measured VCO tuning range is 2.05~3.4GHz. The frequency range is shifted down but still satisfy the target range owing to the design for enough margin. The designed circuit consumes 23~27mA from a 1.8V supply, and the chip size including PADs is $2.0mm{\times}1.5mm$.

Development of a Semi-Atomatic Protocol for embodiment of a desirable 3D breast shape and deployment of bra cup pattern (3차원의 바람직한 유방형상 구현을 위한 Semi-Atomatic Protocol 개발 및 브래지어 컵 패턴으로의 전개)

  • Sohn, Boo-hyun;Kweon, Soo-ae
    • Journal of Fashion Business
    • /
    • v.20 no.4
    • /
    • pp.189-206
    • /
    • 2016
  • A breast model was for the human body was devised by studying a body scan and human body index of a desirable breast type. Thus, when manufacturing various 3D models, these results can accordingly become a fundamental basis for realizing a desirable breast model. This study aims to provide a basic data for designing the cup patterns of brassieres in order to improve the function and wearing comfort. The comfort of three kinds of brassieres were compared: one manufactured by the actual measured size; another manufactured as per the ratio of desirable upper and lower breast lengths; and the third manufactured by the 3D model attained by the desirable human body ratio. In this study, we suggest a process for realizing the desirable breast model using the ratio of bust breadth and waist front length, which are the components for deciding the appropriate position and size of breast, and which are easy to measure. The ideal breast shape is an equilateral triangle formed by connecting the nipple with the center of the clavicle. After deciding the interval between the nipples, this value can be used to configure the locations of nipples by drawing a tangent, with equal length, from the anterior neck point (which is the center of clavicle) to the nipple. Also, since inside points of breast do not exist, the outer point of breast, upper point of breast, and below point of breast on the same plane, and the depths from the nipple point to the respective points, are applied to simulate a 3D image, by modifications along the x, y, and z axes. Depending on the type of breast, the length from the center of shoulder to the nipple, the diameter of breast, upper length of breast, and the position of nipple, are different. In conical or protruding breast, the wearing sensation is better when the nipple point of brassiere was lifted, by modifying the upper and lower lengths of breast. Considering the wearing sensation and function of a brassiere, it was better to leave the wearer's size as it is and use a pad within the same cup, rather than increase the basal area of the breast in order to increase the volume.

Process Capability Optimization of Ball Bonding Using Response Surface Analysis in Light Emitting Diode(LED) Wire Bonding (반응 표면 분석법을 이용한 Light Emitting Diode(LED) wire bonding 용 Ball Bonding 공정 최적화에 관한 연구)

  • Kim, Byung-Chan;Ha, Seok-Jae;Yang, Ji-Kyung;Lee, In-Cheol;Kang, Dong-Seong;Han, Bong-Seok;Han, Yu-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.175-182
    • /
    • 2017
  • In light emitting diode (LED) chip packaging, wire bonding is an important process that connects the LED chip on the lead frame pad with the Au wire and enables electrical operation for the next process. The wire bonding process is divided by two types: thermo compression bonding and ultrasonic bonding. Generally, the wire bonding process consists of three steps: 1st ball bonding that bonds the shape of the ball on the LED chip electrode, looping process that hangs the wire toward another connecting part with a loop shape, and 2nd stitch bonding that forms and bonds to another electrode. This study analyzed the factors affecting the LED die bonding processes to optimize the process capability that bonds a small Zener diode chip on the PLCC (plastic-leaded chip-carrier) LED package frame, and then applied response surface analysis. The design of experiment (DOE) was established considering the five factors, three levels, and four responses by analyzing the factors. As a result, the optimal conditions that meet all the response targets can be derived.

Design and simulation of hydraulic system for launch vehicle holding device (우주발사체 지상고정장치 유압시스템 설계 및 해석)

  • Kim, Dae Rae;Yang, Seong Pil;Lee, Jaejun;Kim, Bum Suk;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1087-1094
    • /
    • 2016
  • The responsibility of the vehicle holding device (VHD) is to hold the launch vehicle while it is stayed on launch pad and release the holding mechanism to allow a lift-off of launch vehicle at a moment of lift-off. During a release of the holding mechanism, in order to prevent the Ka doing a doing a doing mode which is vertical oscillation of entire liquid propellant and very severe for vehicle structure, gradual release of holding force is required. Also, a release operation of all 4 VHD should be synchronized very precisely. In this study, to comply the "gradual release and synchronized operation requirement", concept of VHD hydraulic system using an accumulator, pyro valve and orifice to control speed of hydraulic cylinder is proposed instead of using complicated hydraulic components. Then through multi-body dynamic analysis and computational hydraulic analysis, a size of orifice to meet a target speed of hydraulic cylinder is calculated. Through this study, simple and reliable VHD hydraulic system complying requirements is designed.

Effective Concentration of Procaine Solution for Inotophoresis

  • Lee Jae-Hyoung;Kim Joo-Young;Jekal Seung-Joo
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 1998
  • The purpose of this study was to determine the of effective concentration of procaine iontophoresis for durarion of cutaneous local anesthesia. Forty-five healthy students with an age range of 19 to 34 years$(21\pm2.7)$, were participated in this study. The subjects were randomly assigned into 5 groups. Bach 9 subjects received iontophoresis on the flexor surface of dominant forearm with soft cotton pad $(3.5\times3.5cm)$ soaked in 2ml of $2\%$ (pH 5.28), $4\%$ (pH 5.12), $8\%$ (pH 4,98), $16\%$ (pH 4.72), $32\%$ (pH 4.52) procaine hydrochloride solution at 4mA for 10 minutes (total current 40mA min) using anodal direct current. The study was performed in a randomized, double-blind design, After procaine iontophoresis, the duration of anesthesia were evaluated at five minute intervals on five random locations in the iontophoretically area using a 21-gauge sterile hypodermic needle pressed with 1mm invagination unitl sharp pin-pricking pain sensation returned. The data were analyzed with one-way ANOVA to determine significant differences between groups. Duncan post hoc was performed at level .01. The relationship between anesthetic duration and procaine concentration was assessed with Pearson Product-Moment Correlation Coefficients. ANOVA tests showed significant differences in the anesthetic duration between the concentration of procaine solution (p<.001). Procaine iontophoresis with $4\%$ concentration produced cutaneous Socal anesthesia of significantly longer duration(15.56 min) than iontophoresis with $2\%,\;8\%,\;16\%$, and $32\%$ of procaine GCl(p<.01). Whereas the anesthetic duration had no correlation with concentration of procaine solution (r=-0.41, NS). These results support the $4\%$ procaine solution was an effective concentration of iontophoresis for induced cutaneous local anesthesia.

  • PDF

Mission Design and Analysis based on SEM Angle by Using Variable Coast During 3.5 Earth-Moon Phasing Loop Transfer (Variable Coast를 이용하는 3.5 지구-달 위상전이궤적에서 SEM 각도에 따른 임무설계 및 해석)

  • Choi, Su-Jin;Lee, Donghun;Lim, Seong-Bin;Choi, Suk-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.1
    • /
    • pp.68-77
    • /
    • 2018
  • In order to analyze the overall characteristics of the lunar orbiter, the Variable Coast method, which can be launched everyday, is applied to the 3.5 phasing loop transfer trajectory. The mission scenario for the entire process from launching to entering the lunar orbit is set up and performed simulation by selecting the launch pad and launch vehicle. In particular, the SEM(Satellite-Earth-Moon) angle defined in Earth-Moon rotating frame is an important constraint to comprehensively evaluate the 3.5 phasing loop transfer trajectory. The simulation using SEM angle is analyzed from various viewpoints such as launch epoch, coast duration, perigee altitude and ${\Delta}V$ not only trans-lunar trajectory but lunar orbit insertions and the optimum SEM angle is suggested in this study. It is expected that this results will be helpful to evaluate the characteristics of the 3.5 phasing loop transfer trajectory according to the launch vehicle selection by comparison with Fixed Coast analysis results in the future.

Analysis of Consumer Awareness of Cycling Wear Using Web Mining (웹마이닝을 활용한 사이클웨어 소비자 인식 분석)

  • Kim, Chungjeong;Yi, Eunjou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.640-649
    • /
    • 2018
  • This study analyzed the consumer awareness of cycling wear using web mining, one of the big data analysis methods. For this, the texts of postings and comments related to cycling wear from 2006 to 2017 at Naver cafe, 'people who commute by bicycle' were collected and analyzed using R packages. A total of 15,321 documents were used for data analysis. The keywords of cycling wear were extracted using a Korean morphological analyzer (KoNLP) and converted to TDM (Term Document Matrix) and co-occurrence matrix to calculate the frequency of the keywords. The most frequent keyword in cycling wear was 'tights', including the opinion that they feel embarrassed because they are too tight. When they purchase cycling wear, they appeared to consider 'price', 'size', and 'brand'. Recently 'low price' and 'cost effectiveness' have become more frequent since 2016 than before, which indicates that consumers tend to prefer practical products. Moreover, the findings showed that it is necessary to improve not only the design and wearability, but also the material functionality, such as sweat-absorbance and quick drying, and the function of pad. These showed similar results to previous studies using a questionnaire. Therefore, it is expected to be used as an objective indicator that can be reflected in product development by real-time analysis of the opinions and requirements of consumers using web mining.

Developed a golf course scorecard App that improved UI/UX based on C/S (C/S 기반의 UI/UX를 개선한 골프장 스코어카드 App 개발)

  • Jung, Chul-Jong
    • Journal of Digital Contents Society
    • /
    • v.19 no.8
    • /
    • pp.1433-1442
    • /
    • 2018
  • This study develops and improves the EZ Touch App of the scorecard application (app) using the smartphone and the pad, and works with the customer management system (C/S). The research was conducted as follows. First, how do you handle the EZ Touch input method on a scorecard? Second, how to configure the platform of customer (member) management system (C/S) and data server system? Third, does EZ Touch App work organically with customer management system (C/S)? The developed EZ Touch is entered into the scorecard as an input method using the gesture as a result of this research, and it is linked with the C/S system to organize the review function, hall information function, field coaching function through score, It can be used for applications such as information management functions and statistics through differentiated statistics. However, there are some problems and improvements in user convenience in real time use. I think there is a need to study to solve this problem in the future. EZ Touch input method is input to the scorecard by inputting gesture of the finger as a result of this study, and it is linked with this, and it is possible to use differentiated statistics such as review function, hall information function, field coaching function, It is the purpose of the study to improve the technical competitiveness of the product by developing the application.

A CMOS Fractional-N Frequency Synthesizer for DTV Tuners (DTV 튜너를 위한 CMOS Fractional-N 주파수합성기)

  • Ko, Seung-O;Seo, Hee-Teak;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.14 no.1
    • /
    • pp.65-74
    • /
    • 2010
  • The Digital TV(DTV) standard has ushered in a new era in TV broadcasting and raised a great demand for DTV tuners. There are many challenges in designing a DTV tuner, of which the most difficult part is the frequency synthesizer. This paper presents the design of a frequency synthesizer for DTV Tuners in a $0.18{\mu}m$ CMOS process. It satisfies the DTV(ATSC) frequency band(54~806MHz). A scheme is proposed to cover the full band using only one VCO. The VCO has been designed to operate at 1.6~3.6GHz band such that the LO pulling effect is minimized, and reliable broadband characteristics have been achieved by reducing the variations of VCO gain and frequency step. The simulation results show that the designed VCO has gains of 59~94MHz(${\pm}$17.7MHz/V,${\pm}$23%) and frequency steps of 26~42.5MHz(${\pm}$8.25MHz/V,${\pm}$24%), and a very wide tuning range of 76.9%. The designed frequency synthesizer has a phase noise of -106dBc/Hz at 100kHz offset, and the lock time is less than $10{\mu}$sec. It consumes 20~23mA from a 1.8V supply, and the chip size including PADs is 2.0mm${\times}$1.8mm.

Red Color Light at Different Intensities Affects the Performance, Behavioral Activities and Welfare of Broilers

  • Senaratna, D.;Samarakone, T.S.;Gunawardena, W.W.D.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.7
    • /
    • pp.1052-1059
    • /
    • 2016
  • Red light (RL) marked higher weight gain (WG) and preference of broilers compared to other light colors. This study aimed to investigate how different intensities of RL affect the performance, behavior and welfare of broilers. RL treatments were T1 = high intensity (320 lux), T2 = medium intensity (20 lux); T3 = dim intensity (5 lux), T4 = control/white light at (20 lux) provided on 20L:4D schedule and T5 = negative control; 12 hours dark: 12 hours day light. Cobb strain broilers were used in a Complete Randomize Design with 6 replicates. WG, water/feed intake, feed conversion ratio (FCR), mortality, behavior and welfare were assessed. At 35 d, significantly (p<0.05) highest body weight ($2,147.06g{\pm}99$) was recorded by T3. Lowest body weight ($1,640.55g{\pm}56$) and FCR (1.34) were recorded by T5. Skin weight was the only carcass parameter showed a significant (p<0.05) influence giving the highest (56.2 g) and the lowest (12.6 g) values for T5 and T1 respectively. Reduced welfare status indicated by significantly (p<0.05) higher foot pad lesions, hock burns and breast blisters was found under T3, due to reduced expression of behavior. Highest walking ($2.08%{\pm}1%$) was performed under T1 in the evening during 29 to 35 days. Highest dust bathing ($3.01%{\pm}2%$) was performed in the morning during 22 to 28 days and highest bird interaction (BI) ($4.87%{\pm}4%$) was observed in the evening by T5 during 14 to 21 days. Light $intensity{\times}day$ $session{\times}age$ interaction was significantly (p<0.05) affected walking, dust bathing and BI. Light intensity significantly (p<0.05) affected certain behaviors such as lying, eating, drinking, standing, walking, preening while lying, wing/leg stretching, sleeping, dozing, BI, vocalization, idling. In conclusion, birds essentially required provision of light in the night for better performance. Exposed to 5 lux contributed to higher WG, potentially indicating compromised welfare status. Further researches are suggested to investigate RL intensity based lighting regimen that favors for both production and welfare of Broilers.