• Title/Summary/Keyword: pH measurement test

Search Result 191, Processing Time 0.031 seconds

Development of a Greenhouse Monitoring System Using Network (네트워크를 이용한 온실 감시 시스템의 개발)

  • 임정호;류관희;진제용
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.53-58
    • /
    • 2003
  • This study was carried out to design, construct, and test a greenhouse monitoring system fur the environment and status of control devices in a greenhouse from a remote site using internet. The measuring items selected out of many environmental factors were temperature, humidity, solar radiation, CO$_2$, SOx, NOx concentration, EC, pH of nutrient solution, the state of control devices, and the image of greenhouse. The developed greenhouse monitoring system was composed of the network system and the measuring module. The network system consists of the three kinds of monitors named the Croup Monitor. the Client Monitor and the Server Monitor. The results of the study are summarized as follows. 1. The measuring module named the House Monitor. which is used to watch the state of the control device and the environment of the greenhouse, was developed to a embedded monitoring module using one chip microprocessor 2. For all measuring items. the House Monitor showed a satisfactory accuracy within the range of ${\pm}$0.3%FS. The House Monitors were connected to the Croup Monitor by communication method of RS-485 type and could operate under power and communication fault condition within 10 hours. The Croup Monitor was developed to receive and display measurement data received from the House Monitors and to control the greenhouse environmental devices. 3. The images of the plants inside greenhouse were captured by PC camera and sent to the Group Monitor. The greenhouse manager was able to monitor the growth state of plants inside greenhouse without visiting individual greenhouses. 4. Remote monitoring the greenhouse environment and status of control devices was implemented in a client/server environment. The client monitor of the greenhouse manager at a remote site or other greenhouse manager was able to monitor the greenhouse environment and the state of control devices from the Server Monitor using internet.

The Effects of Nursing Information at Discharge on Level of Knowledge and Daily Activities of Open Heart Surgery Patient (퇴원시 간호정보제공이 개심수술 환자의 지식과 일상활동에 미치는 효과)

  • Kim Keum Soon;Hah Yang Sook;Yoo Kyung Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.4 no.1
    • /
    • pp.25-35
    • /
    • 1990
  • This study examined the evaluation of the information effects of the teaching on knowledge and daily activities of open heart surgery patients between 2 and 6 weeks after discharge. The subject was 29 patients being taught with teaching materials at discharge as experimental group, 20 patients who received no education as control group among the patients who had undergone open heart surgery in S.N.U.H. And research method was non-equivalent control group non-synchronized quasi-experimental design. As the tool of this study, 30 items of knowledge measurement scale which was extracted among the content of teaching materials to evaluate the effect of education and 28 items of which were designed to measure the daily activities of patients with myocardial infarction for the estimation of the degree of observance in daily activities were used. For data analysis, frequency, t-test, Pearson's correlation coefficient and Cronbach's $\alpha$ were used. The result were as follows; 1. Informations given through teaching materials were effective for increasing the knowledge of the patient with open heart surgery. The knowledge of patients increased to the top level (p<0.05) in 2 weeks after discharge. In control group, the knowledge level of patients did not increase after discharge. 2. The knowledge level daily activity of the experimental group was somewat higher than that of the control group, but there was no significant difference. The score .of the experimental group was 69.66 in 6 weeks after discharge much less than the top level score 112. 3. The correlation between knowledge and daily activities was not significant, suggesting the fact that the increase of knowledge did not influence the daily activities significantly. Recommendation was suggested that; 1) Further studies might be .needed with the increasing numbers of the subjects. 2) Daily activities of the patients with open heart surgery should be investigated for long term period until they recovered normal activities.

  • PDF

Quality Characteristics of Bread with Added Black Garlic Extract (흑마늘 추출액을 첨가한 식빵의 품질 특성)

  • Yang, Seung-Mi;Shin, Jung-Hye;Kang, Min-Jung;Kim, Sung-Hyun;Sung, Nak-Ju
    • Korean journal of food and cookery science
    • /
    • v.26 no.5
    • /
    • pp.503-510
    • /
    • 2010
  • Different amounts of black garlic extract(0, 1, 3, 6, 9 and 12%(W/W)) were added to white pan bread, and the quality characteristics were evaluated. The pH and density of dough was decreased with increasing concentration of black garlic extract. There was no marked difference in the fermentation power of the dough expansion among the samples. The pH of bread decreased, and there were no significant differences in baking loss rate, dough yield or bread specific volume as the concentration of black garlic extract was increased. Regarding crust and crumb color values, lightness gradually diminished with increased amounts of black garlic extract in bread, whereas redness and yellowness increased. For measurement of texture, the highest hardness and gumminess of bread were observed in the 1% added group, and there was no remarkable difference between the 3% added group and control. Sensory evolution was the highest when 6% black garlic extract was added, but there were no significant differences in terms of color or overall acceptability. The results imply that addition of black garlic extract to white pan bread created a healthy and functional bread.

Evaluation of Physical Properties of Nanoemulsion Ampoule as Customized Cosmetic Bases and Evaluation of Satisfaction According to Skin Type (맞춤형화장품 베이스로서 나노에멀젼 앰플의 물성 평가 및 피부타입에 따른 만족도 평가)

  • Se-Yeon, Kim;Hyung Guen, An;Ja Young, Kim;Kyung-Sup, Yoon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.4
    • /
    • pp.343-355
    • /
    • 2022
  • Customized cosmetics are continuously mentioned as cosmetics in response to changes in the social environment and trends that emphasize individuality. Therefore, in this study, four types of nanoemulsion ampoules corresponding to skin types were prepared by different ratios of nanoemulsion formulation and ampoule formulation, and the applicability as a customized cosmetic base was checked. Particle size, polydispersity index, zeta potential, and viscosity according to time for 90 d were measured for four nanoemulsion ampoules with different volatile residues, and turbiscan was measured as a method for evaluating the stability of a colloidal dispersion system. Finally, human usability satisfaction was evaluated. As a result, it was confirmed that four kinds of nanoemulsion ampoules had a higher amount of volatile residue in the dry skin test product than in the oily skin test product. The pH was in the range of 6.41 to 6.88, and the particle size was in the range of 170 to 174 nm, and the change after 90 d was within 1.2% of the maximum, and there was no specificity in particle size stability. It was confirmed that the polydispersity index was almost constant, and showed a particle size distribution close to monodispersity by showing a change within a value smaller than 0.21 in all test products. The zeta potential was initially -63 mV or more for all four types of test products, and although it showed a slight decrease with time, there was little change to the extent of a maximum decrease of 2.5%. Viscosity was initially in the range of 4,100 to 5,100 cps and showed a decreasing trend with time, showing a maximum decrease of 37.7%. In the turbiscan measurement, the turbiscan stability index, a measure of stability, was all below 1.0, indicating dispersion stability. In the usability satisfaction evaluation (6 points) of 4 nanoemulsion ampoules corresponding to skin type, oily skin product (5.42 ± 0.67 points) > neutral oily skin product (5.36 ± 0.67 points) > neutral dry skin product (5.15 ± 0.69 point) > dry skin product (4.75 ± 0.75 points) in the order of evaluation. Four types of nanoemulsion ampoules are physically stable and have confirmed their applicability as a customized cosmetic base according to skin type, and are expected to expand in various ways.

Intragastrically Applicated CCl4-Thiopental Sodium Enhanced Lipid Peroxidation and Liver Fibrosis (Cirrhosis) in Rat: Malonedialdehyde as a Parameter of Lipid Peroxidation Correlated with Hydroxyproline as a Parameter of Collagen Synthesis (Deposition)

  • Kim, Ki-Young;Cho, Syung-Eun;Yu, Byung-Soo
    • Toxicological Research
    • /
    • v.25 no.2
    • /
    • pp.71-78
    • /
    • 2009
  • We investigated the pathogenesis of liver tissue damage during the lipid peroxidation and fibrogenesis with the observation of correlations between the parameters of collagen synthesis (and deposition) and lipid peroxidation in liver fibrosis (cirrhosis) rats. Rats were randomly divided into two groups, normal and $CCl_4$-thiopental sod. intoxicated group. And the one group was treated intragastrically with the mixture of $CCl_4$-thiopental sod. 3 times per week for 3 weeks. The liver tissue and sera were used for the measurement of hydroxyproline (HYP), malonedialdehyde (MDA) and superoxide dismutase (SOD). Biochemical parameters such as aspartate transaminase (AST), alanine transaminase (ALT), alkaline phosphatase (ALP), total-bilirubin and blood urea nitrogen (BUN) were measured. Additionally, the expression of collagen ${\alpha}1$(III) and $\beta$-actin mRNA was observed by RTPCR. The histological change in liver tissue was also observed by Masson's trichrome and H&E staining. Correlation analysis was carried by Spearman's rho method. All biochemical parameters except total-bilirubin were significantly higher in the $CCl_4$-thiopental sod. treated group than that of the normal group (p < 0.01). In the $CCl_4$-thiopental sod. treated group, Hyp as a parameter of collagen synthesis (deposition) and MDA as a metabolite of lipid peroxidation, were significantly elevated by 1.98 and 2.11 times higher than that of the normal group (p < 0.001) respectively. The activity of SOD in the $CCl_4$-thiopental sod. treated group is decreased significantly by 44.8% (p < 0.001). And collagen ${\alpha}1$(III) mRNA was more expressed in the $CCl_4$-thiopental sod. treated group than that of the normal group. However, the expression of $\beta$-actin mRNA is showed similar in both of groups. A good correlation was observed between the content of hyp and MDA concentration (r = 0.70, n = 40) in the two groups. And the correlation between the levels of hyp and SOD (r = -0.71, n = 25) is also reliable. However, no correlation were observed between MDA concentration and SOD (r = -0.40, n = 25) in the two groups. Elevated levels of MDA in $CCl_4$-thiopental sod. treated rats indicated enhancement of lipid peroxidation, which is accompanied by a decrease in SOD activity. Moreover, we could confirm that the parameters of collagen synthesis (and deposition) is in good correlation with the metabolite of lipid peroxidation (MDA) and the lipid peroxidation antagonizing enzyme (SOD). Hence, we propose that (1) lipid peroxidation and collagen synthesis (and deposition) could be enhanced by intragastrically application of $CCl_4$-thiopental sod. during a short terms. And (2) the intoxication of $CCl_4$-thiopental sod. could be used for monitoring of lipid peroxidation and collagen synthesis (and deposition) for test of antioxidant and antifibrotic agent.

Quality Characteristics of Yanggaeng according to the Addition of Plantain (Plantago asiatica L.) Powder (질경이 분말 첨가량에 따른 양갱의 품질 특성)

  • Cho, In-Sook;Moon, Jong-Hee;Hong, Ki-Woon;Park, In-Soo
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.226-234
    • /
    • 2016
  • In this study, the possibility of developing new type of yanggaeng has been reviewed by evaluating physio-chemical and sensual characteristics of new yanggaeng products using 5~20% of powder of plantain that is a hardy plant resource from most of hillside in Korea. The moisture contents of plantain powder was 1.9%, DPPH radical scavenging ability was 15.67 mg/mL, and total polyphenol contents was 7.00mg/g. By increasing the adding rate of plantain powder the moisture contents and pH of yanggaeng were decreased. From chromatography, by increasing the adding rate of plantain powder the brightness, L-value was decreased along with redness, a-value, yellowness, and b-value. The a-value of sample group adding 5% of plantain powder was the highest and that of sample group adding 20% was the lowest (p<0.001). From texture measurement shown that the hardness of sample group adding 5% of plantain powder was the highest by 3,937.04 and that of sample group adding 20% of plantain powder was the lowest by 2,153.59. The springiness of sample group adding 5% of plantain powder was the highest by 6.79% and that of sample group adding 20% of plantain powder was the lowest by 4.76%. The cohesiveness of sample group adding 20% of plantain powder was the lowest by 177.35 and it was significant (p<0.001). The result of sensory test showed that sample group adding 10% of plantain powder achieved the highest appraisal from most factors, such as color, scent. sweetness, chewiness, moist level, softness level and total preference. As shown from the above results, the sensory preference of yanggaeng can be improved by adding proper volume of plantain powder while making it, so it is understood that the addition of plantain powder in making yanggaeng would give better possibility in commercialization. By considering sensory preference factor the 10% addition rate of plantain powder while making yanggaeng would be the most proper recipe.

Synthesis, Structure, and Reactivity of the [Fe4S4(SR)4]2- (R = 2-, 3-, and 4-Pyridinemethane) Clusters

  • Kim, Yu-Jin;Han, Jae-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.48-54
    • /
    • 2012
  • The $[Fe_4S_4]^{2+}$ clusters with 2-, 3-, and 4-pyridinemethanethiolate (S2-Pic, S3-Pic, and S4-Pic, respectively) terminal ligands have been synthesized from the ligand substitution reaction of the $(^nBu_4N)_2[Fe_4S_4Cl_4]$ (I) cluster. The new $(^nBu_4N)_2[Fe_4S_4(SR)_4]$ (R = 2-Pic; II, 3-Pic; III, 4-Pic; IV) clusters were characterized by FTIR and UV-Vis spectroscopy. Cluster II was crystallized in the monoclinic space group C2/c with a = 24.530 (5) $\AA$, b = 24.636(4) $\AA$, c = 21.762(4) $\AA$, ${\beta}=103.253(3)^{\circ}$, and Z = 8. The X-ray structure of II showed two unique 2:2 site-differentiated $[Fe_4S_4]^{2+}$ clusters due to the bidentate-mode coordination by 2-pyridinemethanethiolate ligands. Cluster III was crystallized in the same monoclinic space group C2/c with a = 26.0740(18) $\AA$, b = 23.3195(16) $\AA$, c = 22.3720(15) $\AA$, ${\beta}=100.467(2)^{\circ}$, and Z = 8. The 3-pyridinemethanethiolate ligand of III was coordinated to the $[Fe_4S_4]^{2+}$ core as a terminal mode. Cluster IV with 4-pyridinemethanethiolate ligands was found to have a similar structure to the cluster III. Fully reversible $[Fe_4S_4]^{2+}/[Fe_4S_4]^+$ redox waves were observed from all three clusters by cyclic voltammetry measurement. The electrochemical potentials for the $[Fe_4S_4]^{2+}/[Fe_4S_4]^+$ transition decreased in the order of II, III and IV, and the reduction potential changes by the ligands were explained based on the structural differences among the complexes. The complex III was reacted with sulfonium salt of $[PhMeSCH_2-p-C_6H_4CN](BF_4)$ in MeCN to test possible radical-involving reaction as a functional model of the [$Fe_4S_4$]-SAM (S-adenosylmethionine) cofactor. However, the isolated reaction products of 3-pyridinemethanethiolate-p-cyanobenzylsulfide and thioanisole suggested that the reaction followed an ionic mechanism and the products formed from the terminal ligand attack to the sulfonium.

A Study On Structural Stability Of Blast Door by Blast Pressure (폭압에 의한 방폭문의 구조적 안정성에 대한 연구)

  • Kim, Nam Hyuk;Park, Kwan Jin;Lee, Keun-Oh
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.8-15
    • /
    • 2016
  • The purpose of this study is to design a model with the structural stability so as not to lose the operational function due to structural plastic or fail of a sliding blast door by blast pressure to this aim, a numerical simulation was performed using full-size experiments and M&S (Modeling & Simulation) of the sliding blast door. The sliding blast door ($W3,000{\times}H2,500mm$) under the blast load is in the form of a sliding type 2-way metal grill, which was applied by a design blast pressure (reflected pressure $P_r$) of 17 bar. According to the experimental results of a real sliding blast door under blast load, the blast pressure reached the sliding blast door approximately 4.3 ms after the explosion and lasted about 4.0 ms thereafter. The maximum blast pressure($P_r$) was 347.7 psi (2,397.3 kPa), it is similar to the UFC 3-340-02 of Parameter(91 %). In addition, operation inspection that was conducted for the sliding blast door after real test showed a problem of losing the door opening function, which was because of the fail of the Reversal Bolt that was installed to prevent the shock due to rebound of the blast door from the blast pressure. According to the reproduction of the experiment through M&S by applying the blast pressure measurement value of the full-size experiments, the sliding blast door showed a similar result to the full-size experiment in that the reversal bolt part failed to lose the function. In addition, as the pressure is concentrated on the failed reversal bolt, the Principal Tensile Failure Stress was exceeded in only 1.25 ms after the explosion, and the reversal bolt completely failed after 5.4 ms. Based on the result of the failed reversal bolt through the full-size experiment and M&S, the shape and size of the bolts were changed to re-design the M&S and re-analyze the sliding blast door. According to the M&S re-analysis result when the reversal bolt was designed in a square of 25 mm ($625mm^2$), the maximum pressure that the reversal bolt receives showed 81% of the principal tensile failure stress of the material, in plastic stage before fail.

Measurement of Lactoferrin, IgA, IgG1, IgG2, Antibacterial Activity, and Lactic Acid Bacterial Growth in Holstein Colostrum (Holstein 초유 중 Lactoferrin, IgA, IgG1, IgG2 정량과 미생물의 성장에 미치는 영향)

  • Renchinthand, Gereltuya;Bae, Hyoung-Churl;Nam, Myoung-Soo
    • Food Science of Animal Resources
    • /
    • v.27 no.4
    • /
    • pp.522-530
    • /
    • 2007
  • This experiment was carried out to measure the content of lactoferrin, IgA, $IgG_1,\;IgG_2$, in Holstein colostrum, and to test the effect of it's colostrum on the antibacterial activity to pathogenic bacteria and the growth stimulation of lactic acid bacteria. Colostrum was collected at the first, second, and third day after parturition in summer and winter season. The levels of lactoferrin, IgA, $IgG_1,\;and\;IgG_2$ in Holstein cow colostrum were 0.30 mg/mL, 0.37 mg/mL, 4.00 mg/mL, 0.37 mg/mL, respectively, on the first day of the summer season whereas they were 1.16 mg/mL, 2.60 mg/mL, 13.35 mg/mL, 1.30 mg/mL on the first day of the winter season, postpartum. Heat treated ($65^{\circ}C$ for 30 min) or non-treated colostrum showed antibacterial activity toward Escherichia coli. The growth of commercial mixed strains (Bifidobacterium longum, Lactobacillus acidophilus, Streptococcus themophilus), L. acidophilus, L. casei, L. bulgaricus, and L. lactis subsp. cremoris were improved in first, second and third day colostrum compared to normal milk. Commercial miked strains (B. longum, L. acidophilus S. themophilus) lowered the pH to 4.97-5.22 and 4.89 while increasing the titratable acidity to 0.75-0.88% and 0.70% in colostrum and normal milk, respectively. However, L. casei, L. bulgaricus, L. lactis subsp. cremoris lowered the pH to 5.96-6.47 and 6.5-6.8 while increasing the titratable acidity to 0.29-0.48% and 0.20-0.25% in colostrum and normal milk, respectively.

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.