• Title/Summary/Keyword: pH measurement test

Search Result 191, Processing Time 0.033 seconds

A Study on the Failure Detection and Validation of Pressurizer Level Signal in Nuclear Power Plant (원전 가압기수위신호 고장검출 및 검증에 관한연구)

  • Oh, S.H.;Kim, D.I.;Zoo, O.P.;Chung, Y.H.;Lim, C.H.;Yun, W.Y.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.175-177
    • /
    • 1995
  • The sensor signal validation and failure detection system must be able to detect, isolate, and identify sensor degradation as well as provide a reconstruction of the measurements. In this study, this is accomplished by combining the neural network, the Generalized Consistency Checking(GCC), and the Sequential Probability Ratio Test(SPRT) method in a decision estimator module. The GCC method is a computationally efficient system for redundant sensors, while the SPRT provides the ability to make decisions based on the degradation history of a sensor. The methodology is also extended to the detection of noise degradation. The acceptability of the proposed method is demonstration by using the simulation data in safety injection accident of nuclear power plants. The results show that the signal validation and sensor failure detection system is able to detect and isolate a bias failure and noise type failures under transient conditions. And also, the system is able to provide the validated signal by reconstructing the measurement signals in the failure conditions considered.

  • PDF

Variation of Sedimentation & Dewaterability Characteristics of Sewage Sludge under Various Coagulants (응집제 종류에 따른 하수 슬러지의 침강 및 탈수 특성 변화)

  • Baik, Seon Jai;Jo, Jung Min;Song, Hyun Woo;Han, Ihn Sup
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.311-318
    • /
    • 2014
  • The purpose of this study is to investigate the effect of various types of coagulant on dewaterability and settleability of sewage sludge for the application of dewatering process. Cationic organic coagulants and inorganic coagulants of the aluminium base were used; PAC (Poly Aluminium chloride, $Al_2O_3$ 17%) and C-210P (0.2%). After Jar test, PAC 26 mg/L and 0.2% C-210P 55 mg/L was decided as the optimum concentration of the coagulant according to zeta potential measurement. pH, alkalinity and viscosity were measured in all experiments and the data on sedimentation characteristics is analyzed by SDI, SVI sedimentation rate and solid flux. The SRF(Specific Resistance of Filtration) experiment was conducted with the result of single and dual injection system as the dewaterability experiment. As a result, the organic coagulant making large floc has good characteristics of sedimentation and agglutination. Also, it is observed that the organic coagulants injection has a better dewaterability efficiency of coagulants under the condition of the lowest SRF value, followed by dual and inorganic coagulants injection.

Determination of Inorganic Phosphate in Paprika Hydroponic Solution using a Laboratory-made Automated Test Stand with Cobalt-based Electrodes (코발트전극과 자동시험장치를 이용한 파프리카 양액 내 무기인산 측정)

  • Kim, Hak-Jin;Son, Dong-Wook;Kwon, Soon-Goo;Roh, Mi-Young;Kang, Chang-Ik;Jung, Ho-Seop
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.326-333
    • /
    • 2011
  • The need for rapid on-site monitoring of hydroponic macronutrients has led to the use of ion-selective electrodes, because of their advantages over spectrophotometric methods, including simple methodology, direct measurement of analyte, sensitivity over a wide concentration range, and low cost. Stability and repeatability of response can be a concern when using multiple ion-selective electrodes to measure concentrations in a series of samples because accuracy might be limited by drifts in electrode potential. A computer-based measurement system could improve accuracy and precision because of both consistent control of sample preparation and easy calibration of sensors. Our goal was to investigate the applicability of a cobalt-based electrode used in conjunction with a laboratory-made automated test stand for quantitative determination of ${PO_4}^-$ in hydroponic solution. Six hydroponic solutions were prepared by diluting highly concentrated paprika hydroponicsolution to provide a concentration range of 1 to 300 ppm $PO_4$-P. A calibration curve relating electrode response to phosphate in paprika hydroponic solution titrated to pH 4 with 0.025M KHP was developed based on the Nikolskii-Eisenman equation with a coefficient of determination ($R^2$) of 0.94. The laboratory-made test stand consisting of three cobalt-based electrodes measured phosphate concentrations similar to those obtained with standard laboratory methods (a regression slope of 0.98 with $R^2$ = 0.80). However, the y intercept was relatively high, 30 ppm, probably due to the relatively large amount of variation present among multiple measurements of the same sample. Further studies on the high variation in EMFs obtained with cobalt electrodes during replicate measurements were required for P estimations comparable to those obtained with standard laboratory instruments.

Comparative analysis of distance measurement on the rendering screen between dental CAD programs (치과용 CAD 프로그램의 렌더링 화면상 거리측정 비교분석)

  • Cha, Cheol-Ho;Lim, Seon-Young;Bang, Ju-Hyuk;Kim, Seong-Ah;Kim, Seong-Yong;Lee, Yong-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.11-17
    • /
    • 2021
  • Purpose: This study was to find out whether the rendering screen difference affect to measuring distance in a CAD program according to three types of CAD programs. Materials and methods: The model presented in ISO 12836 for dental scanner evaluation was reduced by 70%. This model was repeatedly scanned 15 times using Trios II (3Shape, Denmark). Using the output STL file, 3Shape CAD, inLab 15, and ExoCAD programs were used to measure the horizontal distance (H) and vertical distance (V) between adjacent point angle, and for each experiment, three groups were set according to the CAD program type. Statistical analysis was performed using One-way ANOVA test and post hoc was performed using Dunnett T3 test. Results: In the horizontal and vertical distance measurement, there was no difference in the average of the measured values between the three groups according to the CAD program (P>.05). Conclusion: There were no effect of the difference in the rendering screen in the horizontal and vertical linear distance measurements of the inlay model on the dental CAD program.

Surface treatment of ITO with Nd:YAG laser and OLED device characteristic (Nd:YAG 레이저로 표면처리된 ITO를 전극으로 한 유기EL 소자의 특성)

  • No, I.J.;Shin, P.K.;Kim, H.K.;Kim, Y.W.;Lim, Y.C.;Park, K.S.;Chung, M.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1359-1360
    • /
    • 2006
  • lTO(Indium-Tin-Oxide) was used as anode material for OLED. Characteristics of ITO have great effect on efficiency of OLEDS(Organic light emitting diodes). ITO surface was treated by Nd:YAG laser in order to improve its chemical properties, wettability, adhesive property and to remove the surface contaminants while maintaining its original function. In this study, main purpose was to improve the efficiency of OLEDs by the ITO surface treatment: ITO surface was treated using a Nd:YAG(${\lambda}=266nm$, pulse) with a fixed power of 0.06[w] and various stage scanning velocities. Surface morphology of the ITO was investigated by AFM. Test OLEDs with surface treated ITO were fabricated by deposition of TPD (HTL), Ald3 (ETL/TML) and Al (cathode) thin films. Device performance of the OLEDs such as V-I-L was investigated using Source Measurement Unit (SMU: Keithly. Model 2400) and Luminance Measurement (TOPCON. BM-8).

  • PDF

The Immune-Enhancing Effect of Mountain Gown ginseng, Mountain Cultivated ginseng, and Panax ginseng (산삼(山蔘), 장뇌삼(長腦蔘), 인삼(人蔘)의 면역증강(免疫增强)효과 비교연구)

  • Chung, Dae-Kyoo;Kwon, Soon-Joo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.15 no.2
    • /
    • pp.89-101
    • /
    • 2004
  • Objective : The present experiments were designed to study on the immune-enhancing effect of Mountain grown ginseng, Mountain cultivated ginseng, and Panax ginseng Method : In order to compare the immune-enhancing effect of moutain grown ginseng, moutain cultivated ginseng and Panax ginseng, the study was done through the forced swimming test (FST), measurement of T helper Th1, Th2 cytokines and fatigue related factors. Result : Moutain grown ginseng and panax ginseng decreased the immobility time in the FST compared to the control. Glucose, blood urea nitrogen (BUN), creatinine, lactate dehydrogenase (LDH) and Total-protein (T-protein) in serum were investigated. The serum achieved from ginseng administered mouse showed higher BUN, T-protein than the control. moutain grown ginseng administered group showed lower LDH than the control group. moutain grown ginseng administered mouse showed higher glucose than the control. Creatinine was same in either experimental or control group. Ginseng-induced cytokine production in human T-cell line, MOLT-4 cells and mouse peritoneal macrophages were compared. Moutain cultivated ginseng (10-4 dilution) and panax ginseng (10-3 dilution) were increased the interferon $IFN-{\gamma}$ production compared with media control (about 1.6-fold P<0.05) at 48 h. Moutain grown ginseng (10-4 dilution) was increased the $IFN-{\gamma}$ and interleukin IL-4 production compared with media control (about l.4-fold for $IFN-{\gamma}$ and 1.6-fold for IL-4 P<0.05) at 48 h. Moutain grown ginseng (10-3 dilution) and moutain cultivated ginseng (10-4 dilution) were increased the turmor necrosis factor $TNF-{\alpha}$ production compared with $rIFN-{\gamma}$ treated cells (about 1.9-fold for $TNF-{\alpha}$ P<0.05), respectively. Moutain cultivated ginseng (10-3 dilution) was increased the IL-12 production compared with $rIFN-{\gamma}$ treated cell (about 1.7-fold for IL-12 P<0.05). Conclusion : These data suggest that three different three kinds of ginseng act on immune responses in different aspects.

  • PDF

The Comparison of Acceptance Criteria and Flaw Size Measurement between ASME and RCC-M Code in Ultrasonic Examination (초음파검사시 ASME와 RCC-M CODE에 따른 결함 크기측정 및 허용기준 비교평가)

  • Kim, B.C.;Lim, H.T.;Lee, J.P.;Joo, Y.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.8 no.1
    • /
    • pp.6-11
    • /
    • 1988
  • The comparison and analysis of flaw detectability, flaw sizing methods and allowable criteria in accordance with the applicable codes, ASME and RCC-M Code, in ultrasonic examination of pressure vessel in nuclear power plants were studied. Accordding to the codes, calibration blocks were made. The artificial flaws such as disc and band types in test specimens were machined. They were detected and evaluated with etch code requirements and measured values were compared with the actual flaws.

  • PDF

Basic Physico-Chemical Properties of Representative Ca-Bentonites from Tertiary Sediments (국내산(國內産) 벤토나이트의 몇 가지 물리화학적(物理化學的) 특성(特性)에 관(關)하여)

  • Moon, Hi-Soo;You, Jang Han;Kim, Jong Hwan;Cho, Han Ik
    • Economic and Environmental Geology
    • /
    • v.20 no.3
    • /
    • pp.159-168
    • /
    • 1987
  • Some physico-chemical properties such as surface area, moisture content, cation exchange capacity, swelling rate, pH, viscosity and liquid limit have been determined for evaluation of Cabentonite deposit occurring in four localities; Yonil, Gampo, Haseo and Pohang, in Gyeongsang-do. Montmorillonite contents can be derived from surface area measurement. Enhancement of liquid limit values and swelling volume were observed in the samples which had higher exchangeable Na ion and finer particle-size distribution. Identical results were observed even in the Na-exchanged samples. This suggests that aggregation effects have a great influence on physico-chemical properties. Aggregation of montmorillonite were controlled not only burial depth but also composition of exchangeable cation. Consequently, sample occurred in Yonil area where has the greatest burial depth in the area show somewhat lower physico-chemical properties than those of samples occurred in the other localities. However, the basic test applied in this study provides very useful preliminary information relating to its commercial potential.

  • PDF

Computer Simulation of Hardenability Characteristics of Alloy Steel for Structural Purposes (컴퓨터 시뮬레이션에 의한 구조용 합금강의 경화능특성 해석)

  • Kim, K.S.;Hong, C.P.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.2 no.2
    • /
    • pp.1-10
    • /
    • 1989
  • In this study, the specimens of SCM 22 H steel were quenched in oil and water baths at various agitation conditions in order to investigate the effects of quenchants and agitation conditions on the quench-hardening. A multi-channel temperature measurement apparatus was employed to obtain the cooling curves at several predetermined positions of specimens. Microstructural observation and hardness test were also carried out. Computer simulation of heat treating process was carried out using the modified finite difference method. Prediction of thermal history and hardness distribution by 2-dimensional computer analysis was in good agreement with the experimental results. It was found that the quantitative design of heat treating process can be made by the computer aided heat-treating analysis.

  • PDF

Developing an On-Line Monitoring System for a Forest Hydrological Environment - Development of Hardware - (산림수문환경(山林水文環境) 모니터링을 위(爲)한 원거리(遠距離) 자동관측(自動觀測)시스템의 개발(開發) - 하드웨어를 중심(中心)으로 -)

  • Lee, Heon Ho;Suk, Soo Il
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.405-413
    • /
    • 2000
  • This study was conducted to develop an on-line monitoring system for a forest hydrological environment and its meteorological condition, such as temperature, wind direction and speed, rainfall and water level on V-notch, electrical conductivity(EC), potential of hydrogen(PH) by the motor drive sensor unit and measurement with a single-chip microprocessor as controller. These results are summarized as follows ; 1. The monitoring system consists of a signal process unit, motor drive sensor unit, radio modem unit and power supply. 2. The motor drive sensor unit protects the sensor from swift current or freezing and can constantly maintain fixed water level during measurements. 3. This monitoring system can transfer the data by radio modem. Additionally, this system can monitor hydrological conditions in real time. 4. The hardware was made of several modules with an independent CPU. They can be mounted, removed, repaired and added to. Their function can be changed and expanded. 5. These are the result of an accuracy test, the values of temperature, EC and pH measured within an error range of ${\pm}0.2^{\circ}C$, ${\pm}1{\mu}S$ and ${\pm}0.1pH$ respectively. 6. This monitoring system proved to be able to measure various factors for a forest hydrological environment in various experimental stations.

  • PDF