• Title/Summary/Keyword: pH 센서

Search Result 348, Processing Time 0.029 seconds

pH Sensor using back-gated MOSFET (Back-gated MOSFET을 이용한 pH 농도 측정센서)

  • Park, Jin-Kwon;Kim, Min-Soo;Cho, Won-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.199-199
    • /
    • 2010
  • A back-gated MOSFET on silicon-on-insulator (SOI) substrate for pH sensor was investigated. We used concentrations of pH solution from 6 to 9. The fabricated back-gated MOSFET has current difference and threshold voltage shift by pH concentrations. Therefore, It can be used to simplification of conventional pH sensor.

  • PDF

Characteristics and Fabrication of Dissolved Oxygen and pH Measurement System based on the Optical Sensor for Analysis of Cell Metabolic Functions (세포대사 기능 분석을 위한 광학센서 기반 용존산소와 pH 측정 시스템의 제작 및 특성 분석)

  • Jang, Jiwoon;Hwang, Insook;Lee, Jongmok;Lee, Sunmin;Kang, Sora;Kim Pak, Youngmi;Kim, Nayoung
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.51-56
    • /
    • 2016
  • This study evaluates the performance of an optical sensor and measurement system (CMA-24) which can analyze the fluctuation of dissolved oxygen and pH simultaneously. In the optical sensor system, the fluorescent materials, Rudpp and HPTS which are sensitive to dissolved oxygen and pH, respectively, are coated on the bottom of a 24-well -plate by the sol-gel technology. The detection times of the emission light of the oxygen sensor were $4,186{\pm}13.90{\mu}s$ and $4,452{\pm}36.68{\mu}s$ for the dissolved oxygen of 17% $O_2$ and 7.6% $O_2$, respectively. On the other hand, the detection times of the pH sensor were $6,699.43{\pm}14.64{\mu}s$, $6,722.24{\pm}6.21{\mu}s$, and $6,748.52{\pm}2.63{\mu}s$ using pH 6, 7, and 8, respectively. When we determined cellular respiration levels of C2C12 myocytes with CMA-24, $O_2$/pH measurement system, the ratio of the uncoupled to coupled OCR (oxygen consumption rate) was 1.41. The results mean that this CMA-24 system shows almost the same sensitiveness as the commercial system.

Preparation of Flexible 3D Porous Polyaniline Film for High-Performance Electrochemical pH Sensor (고성능 전기 화학 pH 센서를 위한 유연한 3차원 다공성 폴리아닐린 필름 제조)

  • Park, Hong Jun;Park, Seung Hwa;Kim, Ho Jun;Lee, Kyoung G.;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.539-544
    • /
    • 2020
  • A three-dimensional (3D) porous polyaniline (PANI) film was fabricated by a combined photo-and soft-lithography technique based on a large-area nanopillar array, followed by a controlled chemical dilute polymerization. The as-obtained 3D PANI film consisted of hierarchically interconnected PANI nanofibers, resulting in a 3D hierarchical nanoweb film with a large surface and open porous structure. Using electrochemical measurements, the resulting 3D PANI film was demonstrated as a flexible pH sensor electrode, exhibiting a high sensitivity of 60.3 mV/pH, which is close to the ideal Nernstian behavior. In addition, the 3D PANI electrode showed a fast response time of 10 s, good repeatability, and good selectivity. When the 3D PANI electrode was measured under a mechanically bent state, the electrode exhibited a high sensitivity of 60.4 mV/pH, demonstrating flexible pH sensor performance.

Investigation of the Flow Dependence of a FET-Type Dissolved Oxygen Sensor and Its Reducing Method (FET형 용존 산소 센서의 유속에 의한 영향 조사와 감쇄 기법)

  • Jeong, H.;Kim, Y.J.;Lee, Y.C.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.180-186
    • /
    • 2001
  • Recently, FET type dissolved oxygen sensor was proposed to overcome the disadvantages of the amperometric Clark-type sensor. The inherent problem of the proposed sensor, however, is the flow dependence of the sensor performances since the proposed sensor detects the pH change in close proximity to the working electrode. In this study, we decided the direction which minimize the flow effect in FIA(flow injection analysis) system. And a hydrodynamic buffer layer which can reduce the flow dependence were proposed. The suggested buffer-layers were formed onto sensing area and working electrode with mixed polymer matrix of TEOS(tetraethylorthosilicate) and DEDMS(diethoxydimethylsilane).

  • PDF

Micro humidity sensor with poly imide sensitive layer (폴리이미드를 감지막으로 한 마이크로 정전용량형 습도센서)

  • Shin, P.K.;Cho, K.S.;Park, G.B.;Yuk, J.H.;Park, J.K.;Im, H.C.;Ji, S.H.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1898-1899
    • /
    • 2005
  • 반도체 집적회로 공정에서 사용되는 폴리이미드 포토레지스트(P12723, Dupont)를 감습막으로 사용하는 마이크로 습도센서 소자를 제작하였다. 마이크로 습도센서는 실리콘 웨이퍼 기판 위에 $SiO_2$ 박막을 건식열산화 공정으로 제작하고, Al 박막을 포토리소그라피 공정으로 패터닝 한 IDT (Interdigital Transducer)를 전극 위에 폴리이미드 포토레지스트를 공정변수를 다양하게 조절하면서 감습막으로 제작하였다. 폴리이미드 감습막은 스핀코팅법으로 제작하였으며, 회전수를 조절하여 두께를 변화시켰다. 완성된 마이크로 습도센서 소자의 상대습도 변화$(10{\sim}90% RH)$에 따른 정전용량 값 변화를 항온항습조 내에서 다양한 온도에서 HP4192A Impedance Analyzer를 사용하여 조사함으로써, 폴리이미드 포토레지스트를 사용하는 마이크로 정전용량형 습도센서의 제작 가능성을 검토하였다. 폴리이미드 정전용량형 마이크로 습도센서는 다양한 인가 전원 주파수에서 기준 센서로 사용된 상용 Vaisala Hygrometer와 유사한 감습특성 및 응답특성을 보였다.

  • PDF

pH Sensor Application of Printed Indium-Tin-Oxide Nanoparticle Films (Indium-Tin-Oxide 나노입자 인쇄박막의 pH sensor 응용에 대한 연구)

  • Lee, Changhan;Noh, Jaeha;An, Sangsu;Lee, Sangtae;Seo, Dongmin;Lee, Moonjin;Chang, Jiho
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.85-89
    • /
    • 2022
  • We investigated a pH sensor using an Indium tin oxide (ITO) nanoparticle (NP) film printed on a flexible substrate. First, the printing precision and mechanical stability of the ITO-printed film were investigated. In particular, the factors that influence the crystallinity of ITO films were studied using X-ray diffraction pattern analysis. The response of the ITO pH sensor was calibrated using a series of standard pH solutions (pH 3-11). The pH values of various specimens were measured using an ITO pH sensor, and the results were compared with those of various pH measurement methods. As a result of the experiment, the maximum error was approximately ± 0.04 pH (0.4 %) at pH 9, which indicated that the ITO pH sensor is highly suitable for pH measurement. Finally, we used the ITO pH sensor to the measure of general specimens such as solvents and beverages and compared the results in comparison with those obtained from several conventional methods.

Aroma Pattern Analysis of Hanwoo Beef (M. longissimus) using Electronic Nose during Refrigerated Storage (전자 코를 이용한 한우 등심육의 냉장저장 중 향기 패턴 분석)

  • Lee Sung Ki;Kim Ju Yong;Kim Yong Sun
    • Food Science of Animal Resources
    • /
    • v.24 no.3
    • /
    • pp.260-265
    • /
    • 2004
  • This study was carried out to investigate aroma patterns of Hanwoo (Korean cattle) beef using electronic nose during refrigerated storage, and to compare these results with chemical quality (pH, TBARS). The M. longissimus muscle from Hanwoo carcasses after 24 hrs postmortem was obtained and stored at 5${\pm}$1$^{\circ}C$ for 7 days. Sensitivity (dR/RO) values among electronic nose data were changed differently during refrigerated storage, and showed significant difference on the 7th day of storage (p<0.01). The dR/RO from SY/G, SY/AA, SY/Gh, SY/gCTl, SY/gCT decreased but those from SY/LG, T30/1, P10/1, P10/2, P40/1, T70/2, PA2 increased during storage for 7 days. Mapping these data using PCA (principal component analysis) showed that the 1st day data were present in the middle of the right side, the 3rd day data were present in bottom part of this area and the 7th day data spread out more widely on the left side. In case of DFA (discriminant factor analysis), the flock clustered round and located in different side clearly comparing with PCA plot. In analysis of correlation coefficients among electronic nose data and chemical quality data, there was significant correlation among sensor data (p<0.001). But pH and TBARS were not significantly correlated with electronic nose data. Consequently, PCA and DFA plot by electronic nose data showed difference during refrigerated storage and there were significant correlations among sensors. Therefore it will be possible to detect separate aroma patterns of Hanwoo beef using electronic nose.

Development of Reflection-type Fiber-optic pH Sensor Using Sol-gel Film (졸-겔 필름을 이용한 반사형 광섬유 pH 센서의 개발)

  • Yoo, Wook-Jae;Seo, Jeong-Ki;Jang, Kyoung-Won;Moon, Jin-Soo;Han, Ki-Tek;Park, Jang-Yeon;Lee, Bong-Soo;Cho, Seung-Hyun;Heo, Ji-Yeon;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.266-271
    • /
    • 2011
  • A reflection-type fiber-optic pH sensor, which is composed of a pH sol-gel film, plastic optical fibers, a mirror, a light source and a spectrometer, is developed in this study. As pH indicators, a bromthymol blue, a cresol red and a thymol blue are used, and they are immobilized in the sol-gel films. The emitted light from a light source is guided by a fiber-optic Y-coupler and plastic optical fibers to the pH sol-gel film in a pH sensing probe. The pH change in the sensing probe gives rise to a change in the color of the pH sol-gel film, and the optical characteristic of reflected light through the pH sol-gel film is also changed. Therefore, we have measured the spectra of reflected lights, which are changed according to the color variations of the pH sol-gel films with different pH values, by using of a spectrometer. Also, the relationships between the pH values and the intensities of reflected lights are obtained on the basis of the color variations of the pH sol-gel films.

Development and Performance Evaluation of Multiple Sensor for Groundwater Quality Monitoring and Remote Control System using IoT (IoT기반 지하수 수질모니터링을 위한 다중센서모듈 개발 및 성능평가)

  • Chang, Hyunjin;Moon, Boram;Yoon, Seunggyun;Jin, Taeseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1957-1963
    • /
    • 2017
  • This paper has proposed a new-type groundwater auto-monitoring system based on Multi-Sensor Device. The system adopted Multi-Sensor Device as host computer of data acquisition, used Windows Mobile which was prevalent operation system of Multi-Sensor Device. It adopted serial port CAN and RS485 as the communication interface between goundwater sensor Device and monitor host machine and utilized serial-linked multi-sensor design to measure effectively according to the depth of groundwater. We present a design for a groundwater monitoring system based on a network of wirelessly linked sensors. The proposed solution will enable groundwater researchers and decision makers to have quick access to the groundwater data with less effort and cost. Though our design is initially meant for groundwater monitoring, it can be easily adapted to other fields of environmental monitoring.

Sensitivity of BOD Sensor with Heavy Metal Tolerant Serratia marcescens LSY4 (Serratia marcescens LSY4 중금속 내성주를 이용한 BOD센서의 감응도)

  • Kim Mal-Nam;Lee Sun-Young
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.394-399
    • /
    • 2004
  • A BOD sensor was prepared with S. marcescens LSY4 and was applied for measurement of BOD values of a solution containing the standard organic pollutants. The sensor sensitivity was nearly independent of the culture time in the range of 9-16 hours. It was also affected little by the cell mass in the range of 0.22-0.75 mg $cm^{-2}$. A cyclic change in the solution pH in the range of 4-9 was accompanied by a reversible variation in the sensor sensitivity. However, the reversibility was lost when the solution pH became more acidic or more basic. Heavy metal ions lowered the sensor sensitivity, which took place more precipitously in the presence of $Cu^{2+}$ and $Ag^+$ rather than in the presence of $Zn^{2+}$ and $Cd^{2+}$. The reduction of the sensor sensitivity was significantly attenuated by loading heavy metal ion tolerance induced strain. The $Cu^{2+}$tolerance induced strain was more efficient for the attenuation than $Zn^{2+}$ and $Cd^{2+}$ tolerance induced strain.