• Title/Summary/Keyword: pH 센서

Search Result 348, Processing Time 0.027 seconds

Fabrication of Disposable pH Sensor with Micro-volume Type (Micro-volume형 일회용 pH 센서 제작)

  • Jung, Ho;Kim, Heung-Rak;Kim, Young-Duk;Jung, Woo-Chul;Kim, Dong-Su;Nam, Hyo-Duk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.950-952
    • /
    • 2003
  • This paper have been studied fabrication and characteristics of disposable pH sensor using MEMS technology. The sensor has two open-well structure, the container for the internal electrolyte and electrode were formed by anisotropically etching a silicon substrate. unlike currently used KCI saturated solution, the structure was introduced hydrogel which take an advantage of miniaturization, bulk product, a low price. PU and CA/TP used to measurement ion detection, one is reference membrane and the other is pH. fabricated sensor is encapsulated entirely with epoxy, finally sensor was estimated various ion sorts and pH ranges.

  • PDF

Capacitive Sensor for in situ Measurement of Deterioration of Car Engine Oil (자동차 엔진오일 열화상태 in situ 측정용 전기용량 센서)

  • Lee, R.D.;Kim, H.J.;Semenov, Yu. P.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.266-272
    • /
    • 2001
  • A coil-type capacitive sensor on which the deterioration of the car engine oil can be in situ measured, has been developed. The sensor was designed to get over 10 pF at the limited space on the drain hole of the oil pan. The design factors for stable capacitance measurement such as coil diameter and winding condition, materials and configuration of the coil former, and shielding method, etc., were known by both computer simulation and experimental investigations. The dielectric properties measured by several sensors for an used sample oil were consisted within 0.25%. The sensor installed on the car having severe vibration, temperature and humidity fluctuation, even electromagnetic noise, has shown very distinguishable results.

  • PDF

Effect of Subacute Ruminal Acidosis on Plasma Concentrations of Lipopolysaccharide in Dairy Cattle (젖소에 있어 아급성제1위과산증(SARA)의 강도가 혈장 Lipopolysaccharide (LPS)의 농도에 미치는 효과)

  • Son, Hey In;Baek, Seong Gwang;Moon, Ju Yeon;Ahn, Eui-Young;Lee, Hyun-Jun;Son, Yong Suk
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.33 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • A study was conducted to determine if subacute ruminal acidosis (SARA) induced by feeding high level of non-structural carbohydrates results in increases in lipopolysaccharides (LPS) of peripheral blood in dairy cattle. In this experiment four Holstein steers, two of which having ruminal canulae with indwelling probes placed for measuring long term pH changes, were alloted into two dietary treatments in a cross-over design, where an acidogenic diet (AD) was formulated by including high amount of non-structural carbohydrates (NSC) based on corn silage and corn flake as TMR ingredients. Data for ruminal pH change and plasma LPS concentration were compared against normal diet (ND) which contained grass hay as forage and low NSC ingredients. Feeding AD for more than 14 days to animals brought about a pH change as low as less than 5.8 for more than 4 hours, which made good contrast to ND fed animals. Decreased ruminal pH also had an effect on LPS concentrations which showed significantly higher level for AD compared with ND. Therefore, plasma LPS concentration may be used as an effective indicator to verify acidosis whether it is acute or chronic. Na-bentonite and Propylene glycol, which are frequently included in dairy TMR as additives, helped decrease ruminal pH by buffering and then ultimately alleviates SARA. Therefore, it could also be helpful to lower the occurrence of laminitis which is often caused by increased blood endotoxin (LPS) concentration.

Development of Prototype Biosensor for The Detection of Organophosporus Compounds (유기인화합물 측정용 광바이오센서 개발)

  • 최정우;김종민;이원홍;김영기
    • KSBB Journal
    • /
    • v.17 no.2
    • /
    • pp.158-161
    • /
    • 2002
  • In this study, a prototype fiber-optic biosensor was fabricated using the inhibition of enzyme reaction by organophosphorus compounds to detect organophosphorus compounds, which is nervous toxic material an? is used as chemical weapon and pesticide. Enzyme, substrate, and inhibitor for enzyme reaction were acetylcholinesterase (key enzyme in nervous cell), acetylthiocholine iodide, and paraoxon (a kind of organophosphorus compounds), respectively. The detection principle of sensor is the detection of enzyme reaction inhibited by organophosphorus compounds by the quantitative measurement of acetic acid, which was achieved by absorbance measurement using litmus solution that maximum absorbance band is changed by pH. To fabricate prototype fiber-optic biosensor, high bright LED and photodiode was used as light source and light intensity detector, respectively. From the experimental results using a prototype biosensor, the linear change of sensor signal was obtained in a range of 0-2 ppm inhibitor concentrations. From these results, it was verified that the quantitative measurement of organophosphorus compounds could be achieved fast (within 2 minutes) and accurately by a prototype fiber-optic biosensor.

The Study on the Realtime Evaluation of NH3 Absorption Efficiency Using Chemical Gas Sensor (가스센서를 활용한 암모니아 가스의 실시간 흡수 효율 평가에 관한 연구)

  • Lim, Jung-Jin;Kim, Han-Soo;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.4
    • /
    • pp.233-239
    • /
    • 2013
  • This study was carried out to develop the realtime evaluation system of $NH_3$ absorption efficiency with gas sensors which were installed on the inlet and outlet of lab-scale scrubber system. The $NH_3$ absorption amount, calculated by sensor outcomes for 3 hr, 6 hr, and 12 hr of absorption process, was compared with the results analysed by Indo-phenol method for the absorption solution. Even though the difference between two methods was about 20%, the correlation coefficient between the two results was very high, more than 0.99. In addition, we could find very good correlation between pH, absorption amount and reaction time. Also we could find out the breakthrough time in the middle of absorption process. With more diverse experiment in the future, we can make gas sensor system for the realtime evaluation of the odor and/or air pollution treatment efficiency.

Electrochemical Study on Transfer Reaction of Ionizable Cefotiam across a Water/1,2-dichloroethane Interface and Drug Sensing Applications (물/1,2-Dichloroethane 계면에서 Cefotiam 약물 이온의 전이 반응 연구 및 약물 센서에 응용)

  • Liu, XiaoYun;Jeshycka, Shinta;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.581-588
    • /
    • 2018
  • In this article, electrochemical investigation of the transfer reaction of ionizable cefotiam (CTM), an antibiotic molecule across a polarized water/1,2-dichloroethane (water/1,2-DCE) interface was studied. Ion partition diagram providing the preferred charged form of CTM in either water or 1,2-DCE phase was established via the voltammetric evaluation of the transfer process of differently charged CTM species depending upon the pH variation of aqueous solutions. Thermodynamic information including the formal transfer potential and formal Gibbs transfer energy values in addition to important pharmacokinetics including partition coefficients of ionizable CTM were also evaluated. In particular, the current associated with the transfer of CTM present at pH 3.0 aqueous solution proportionally increased with respect to the CTM concentration which was further used for developing CTM sensitive ion sensor. In order to improve the portability and convenient usage, a single microhole interface fabricated in a supportive polyethylene terephthalate film was used of which hole was filled with a polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel replacing 1,2-DCE, a toxic organic solvent. A dynamic range of $1-10{\mu}M$ CTM was obtained.

Preparation of a New $K^{+}-ISFET$ Modified with 4'-Aminobenzo-15-crown-5 and Its Response Characteristics (4'-Aminobenzo-15-crown-5를 수식한 새로운 $K^{+}-ISFET$의 제조와 감응특성)

  • Lee, H.L.;Yun, J.H.;Yang, S.T.;Jung, D.S.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.85-92
    • /
    • 1992
  • A new potassium sensitive field effect transistor modified with 4'-aminobenzo-15-crown-5 was prepared and its response characteristics were evaluated. The response slope of $K^{+}-ISFET$ for pH was 30.0 mV/decade and the response time was mere than 3 minutes. And the response slope and time of the $K^{+}-ISFET$ for potassium ion as $19.5{\pm}0.2{\;}mV/decade$ and about 3 minutes, respectively. The linear response range of the sensor for potassium ion was $2.0{\times}10^{-4}{\sim}1.0{\times}10^{-2}M$. The selectivity coefficients of the $K^{+}-ISFET$ for the alkali and alkaline earth metal ions were also evaluated. Sodium, ammonium and calcium ions exhibited relatively significant interference. The long term stability of the sensor was remarkably improved and it could be used for more than 50 days.

  • PDF

Characteristics of a-Si:H Multilayer for Contact-type Linear Image Sensor (밀착형 1차원 영상감지소자를 위한 a-Si:H 다층막의 특성)

  • Oh, Sang-Kwang;Kim, Ki-Wan;Choi, Kyu-Man
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.5-12
    • /
    • 1992
  • We have fabricated a-Si:H multilayer for contact-type linear image sensor by means of RF glow discharge decomposition method. The ITO/i-a-Si:H/Al structure has relatively high dark current due to indium diffusion and carrier injection from both electrodes, resulting in low photocurrent to dark current. To suppress the dark current and to enhance interface electric field between ITO and i-a-Si:H film we have fabricated ITO/insulator/i-a-S:H/p-a-S:H/Al multilayer film with blocking structure. The photocurrent of ITO/$SiO_{2}(300{\AA})$/i-a-Si:H/p-a-Si:H($1500{\AA}$)/Al multilayer sensor with 5V bias voltage became saturated at about 20nA under $20{\mu}W/cm^{2}$ light intensity, while the dark current was less than 0.1nA. To increase the light generation efficiency we have adopted ITO/$SiO_{x}N_{y}(300{\AA})$/i-a-Si:H/p-a-Si:H($1500{\AA}$)/Al structure, showing photocurrent of 30nA and dark current of 0.08nA with 5V bias voltage. Also the spectral photosensitivity of the multilayer was enhanced for short wavelength visible region of 560nm, compared with that of the a-Si:H monolayer of 630nm. And its photoresponse time was about 0.3msec with the film homogeneity of 5% deviation.

  • PDF

Determination of Complex Formation Constant of Sodium-Selective Ionophores in Solvent Polymeric Membranes (용매 고분자막 상에 고정된 나트륨 이온선택성 물질의 착물형성상수 결정)

  • Kang, Tae Young;Kim, Sung Bae;Oh, Hyon Joon;Han, Sang Hyun;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • The complex formation constants (${\beta}_{MLn}$) of potassium and various sodium-selective neutral carriers in solvent polymeric membranes have been determined using solvent polymeric membrane-based optodes and ion-selective electrodes (ISEs). Two different types of PVC-based membranes containing the H^+selective chromoionophore (ETH 5294) with and without a sodium ionophore (4-tert-bntylcalix[4]arenetetraacetic acid tetraethyl ester, ETH 2120, bis[(12-crown-4)methyl] dodecylmethylmalonate or monensin methyl ester) were prepared and their optical responses to either the changes in alkali metal cation (e.g., sodium and potassium) concentrations at a fixed pH (0.05 M Tris-HCl, pH 7.2) or varying pH at a fixed alkali metal cation concentration (0.1 M) were measured. The same type of membranes were also mounted in conventional electrode body and their potentiometric responses to varying pH at a fixed alkali metal cation concentration (0.1 M) were measured. The complex formation constants of the ligand could be calculated from the calibration plots of the relative absorbance vs. the activity ratios of cation and proton ($a_{M^+}/a_{H^+}$) and of the emf vs. pH. It was confirmed that the ratio values of the complex formation constants for the primary and interfering ions are closely related to the experimental selectivity coefficients of ISEs.

  • PDF

Production and Process Monitoring of 5-Aminolevulinic Acid (ALA) by Recombinant E. coli II. process Monitoring by a 2-Dimensional Fluorescence Sensor (유전자 재조합 대장균에 의만 5-Aminolevulinic Acid (ALA)의 생산 및 공정 모니터링 II. 2차원 형광센서에 의안 공정 모니터링)

  • 이종일;정상윤;임용식;정상욱
    • KSBB Journal
    • /
    • v.19 no.1
    • /
    • pp.27-32
    • /
    • 2004
  • 2-Dimensional fluorescence sensor has a wide range of excitation and emission wavelengths, that some biogenic fluorphors in a biological process can be monitored simultaneously. The production processes of 5-aminolevulinic aicd (ALA) by recombinant E. coli BL21 (DE3) pLysS harboring plasmid pFLS45 were on-line monitored by a 2-dimensional fluorescence sensor The characteristics of fluorescence spectrum was dependent upon physical and biological factors of a bioprocess such as culture pH, cell mass etc. Some off-line data were correlated to the fluorescence intensity well, which was monitored at some combination of excitation and emission wavelengths by the 2-dimensional fluorescence sensor.