• Title/Summary/Keyword: p-set

Search Result 3,439, Processing Time 0.043 seconds

Trace Metal Contents and Safety Evaluation of Major Edible Seaweeds from Korean Coast (한국산 주요 식용해조류의 미량금속 함량 및 안전성 평가)

  • Mok, Jong-Soo;Park, Hee-Yeon;Kim, Ji-Hoe
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.9
    • /
    • pp.1464-1470
    • /
    • 2005
  • To assure the safety of the major edible seaweeds, we collected the 176 samples of seaweeds such as laver(Porphyra sp.), sea mustard (Undaria pinnatifida), sea tangle (Laminaria japonica) and sea lettuce (Enter-omorph sp.) from Korean coast. We investigated the contents of the trace metals in the edible seaweeds, and the values were expressed as the dry weight of sea weeds. The mean levels of the trace metals were high in the oder of Zn ($36.19{\pm}27.14 \;{\mu}g/g$), Mn ($28.75{\pm}28.03\;{\mu}g/g$), and Cu ($6.82{\pm}7.62\;{\mu}g/g$), which are necessary metals in the human body, and then followed by Cr ($1.54{\pm}2.07\;{\mu}g/g$), Ni ($1.29{\pm}2.57\;{\mu}g/g$), Pb ($0.89{\pm}1.11\;{\mu}g/g$), Cd ($0.72{\pm}0.80\;{\mu}g/g$) and Hg ($0.01{\pm}0.02\;{\mu}g/g$). The contents of Cd and Zn were high in the laver, Cr, Ni and Pb were detected highly in sea lettuce, and Hg was detected highly in sea tangle. Significant linear correlations were obtained among 28 different pairs of metals, some of them highly correlated (r>0.5, p<0.05),such as Ni-Mn, Zn-Ni, Cu-Pb and Cu-Zn in laver, Ni-Zn in sea mustard, Cu-Pb, Cu-Zn and Mn-Pb in sea tangle, and Ni-Cr in sea lettuce. And, the trace metal contents of seaweeds varied with parts and kinds of samples. The average weekly intakes of Hg, Cd and Pb from seaweeds were about $0.07{\~}3.57\%$ of PTWI (Provisional Tolerable Weekly Intakes) which has set by FAO/WHO to evaluate the safeties of trace metals in food. Therefore, it was found that they showed very safe levels in the edible seaweeds.

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF

Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

study of comparison between Nae-gyung(內經) and later physian's theory on In-yeong-gi-go Maek(人迎氣口脈) (인영기구맥(人迎氣口脈)에 대(對)한 내경(內經)과 후대(後代) 의가설(醫家說)과의 비교(比較) 연구(硏究))

  • Kim, Tae-Eun;Kim, Tai-Hee
    • The Journal of Internal Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.152-164
    • /
    • 1994
  • In Nai-Gyung(內經), it is said that In-Yeong(人迎) means In- Yeong Maek(人迎脈), Gi-Gu m- eans Tson-Gu(寸口) or Maek- Gu(脈口), In-yeong, artery in the side of neck, is located before Yeong-Geun(瓔筋), called as Jok-Yang-Myung-Maek(足陽明脈),so the part of In-Yeong-Maek means In-Yeong-Hyul(人迎穴) of Jok-Yang-Myung- Wi-Gyung(足陽明胃經) showing the artery in the side of neck. The part of Tson-Gu-Maek is that of artery in Yo-Gol(橈骨), beating source of Soo-Tae-Eum-Maek (手太陰脈) Of In-Yeong-Gi-Gu-Maek, In-Yeong-Maek mainly consists of Yang(陽), Gi-Gu-Maek of Eum(陰), so In-Yeung means physical disease, short of extra Eum component. They said that if In-Yeong-Maek was more than Gi-Gu-Maek, it meant physical injury, while Gi-Gu-Maek was more than In- Yeo-ng-Maek, it meant internal injury. In-Yeong-Gi-Gu-Maek is the one to distinguish the external and internal, the inside and outside, Eum and Yang, but there is no definite classification method to distinguish it, also it is difficult to grasp the comparison of 1sung(1盛), 2sung(2盛), 3sung(3盛), interrelation with 12-Gyung-Rak(l2經絡), change of maek phases, so necessary to set up the clear definition for In-Yeong-Gi-Gu-Maek. For the two theories as to In-Yeong-Gi-Gu-Maek according to Nai-Gyung, the one is to diagnose the maek by comparing the In-Yeong-Hyul with Tson-Gu of Soo-Tae-Eum-Maek as Gi-Gu in the both sides of neck part, he other is to divide the left and right of Gi-Gu-Maek in to In-Yeong and Gi-Gu afterwards, but today it is difficult to compare and explain the medical theory afterwards owing to insufficient consideration of In-Yeong-Gi-Gu-Maek at Nai-Gyung. The diagnosis of In-Yeong-Gi-Gu-Maek at Nai-Gyung to distinguish the surplus and shortage of Eum and Yang up to now since Nai-Gyung has so important and diagnostic value as to grasp the exact meaning. Herewith, this researcher com-pared Nai-Gyung and medical theory afterwards, reported it to consider the fixed position and changing process of viscera and entrails arrangement of literatures introducing In-Yeong-Gi-Gu-Maek, examining the change of maek phases for normal maek and a-bnormal maek of In-Yeong-Gi-Gu-Maek, considering the 1 sung, 2 sung, 3 sung maek phases in In-Yeong-Gi- Gu-Maek. According to the above results, the conclusion was reached as follows. 1. In-Yeong as the outside indicates external disease(外感), showing the surplus and shortage of Yang symptom by having Boo-Maek(浮脈) as Py-ung-Maek(平脈), Gi-Gu as the inside indicates internal disease(內傷), showing the surplus and shortage of Eum symptom by having Chim-Maek(沈脈) as P-yung-Maek(平脈). 2. In Pyung-Maek of In- Yeong-Maek as Boo-Maek, g-radual sinking of more floated changing maek because of disease means the improvement of di-sease, in Pyung-Maek of Gi- Gu-Maek as Chim- Maek, gradual floating of more sunken changing maek because of disease means the improvement of disease. 3. They said that disease of Jok-Gyung-Rak(足經絡) is cha-nged to that of Soo-Kyung-Rak(手經絡) when Jo-Maek(躁脈) appears whether In-Yeong-Maek or Gi-Gu-Maek 4. With the exemples of 1 sung 2 sung 3 sung it was porned with the relation of Pyo-Ri-Soo-Jok(表裏手足). Therfore I can guess that this fact is a moment explained the Bu-You-Sa-Kyung(部有四經) mentioned in Nan-Gyung-18-Nan(難經 第18難). 5. I think that In-Yeong and Gi-Gu, as a diagnosis method which distinguish between the inside indicates internal disease and the outside indicates external disease, is required to study further researches.

  • PDF

Monitoring of Pesticides in the Yeongsan and Seomjin River Basin (영산강 및 섬진강 수계 중 농약 분포 조사)

  • Lee, Young-Jun;Choi, Jeong-Heui;Kim, Sang Don;Jung, Hee-Jung;Lee, Hyung-Jin;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.274-281
    • /
    • 2015
  • BACKGROUND: A lasting release of low levels of persistence chemicals including pesticides and pharmaceuticals into river has a bad influence on aquatic ecosystems and humans. The present study monitored pesticide residues in the Yeongsan and Seomjin river basins and their tributaries as a fundamental study for water quality standard of pesticides.METHODS AND RESULTS: Nine pesticides(aldicarb, carbaryl, carbofuran, chlorpyrifos, 2,4-D, MCPA, methomyl, metolachlor, and molinate) were determined from water samples using SPE-Oasis HLB(pH 2) and LC/MS/MS. Validation of the method was conducted through matrix-matched internal calibration curve, method detection limit(MDL), limit of quantification(LOQ), accuracy, precision, and recovery. MDLs of all pesticides satisfied the GV/10 values. Linearity(r2) was 0.9965- 0.9999, and a percentage of accuracy, precision, and recovery was 89.4-113.6%, 3.1-14.0%, and 90.8-106.2%, respectively. All pesticides exclusive of aldicarb were determined in the river samples, and there was a connection between the positive monitoring results and agricultural use of the pesticides.CONCLUSION: Monitoring outcomes of the present study implied that pesticides were a possible non-point pollutant source in the Yeongsan and Seomjin river basins and tributaries. Therefore, it is required to produce and accumulate more monitoring results on pesticides in river waters to set water quality standards, finally to preserve aquatic ecosystems.

Effect of Root Zone Warming by Hot Water on Fruit Characteristics and Yield of Greenhouse- Grown Oriental Melon (Cucumis melo L.) (온수 지중가온이 참외의 과실특성 및 수량에 미치는 영향)

  • 신용습;이우승;연일권;최성국;최부술
    • Journal of Bio-Environment Control
    • /
    • v.6 no.2
    • /
    • pp.110-116
    • /
    • 1997
  • This experiment was conducted to investigate the effects of root zone warming on fruit yield of oriental melon (Cucumis melo L. var. Makuwa) in winter season. Root zone was warmed by hot water flowing through pipe set at 35cm depth from the ridge. Treatments of minimum soil temperature at 20cm depth were 17, 21, $25^{\circ}C$ and non-warming from Jan. 18 to Apr. 18. The results are summarized as follows. 1. The blooming of female flower was faster 1 days in 17$^{\circ}C$ plot, 6 days in 21$^{\circ}C$ plot, and 7 days in $25^{\circ}C$ plot than in control plot and the days from blooming to harvesting were shorter 5 days in 17$^{\circ}C$ plot, 11 days in 21$^{\circ}C$ plot, and 12 days in $25^{\circ}C$ plot than in control plot. 2. Mean fruit weight was the highest in 21$^{\circ}C$ plot, followed $25^{\circ}C$, 17$^{\circ}C$ and control plots, respectively, and flesh thickness was the highest in $25^{\circ}C$ plot, followed by 21, 17$^{\circ}C$ and control plots, respectively. 3. Early and middle-phase yield was the highest in $25^{\circ}C$ plot, followed by 21$^{\circ}C$, 17$^{\circ}C$ and control plots but late yield was the highest in 17$^{\circ}C$ plot, followed by control, 21, and $25^{\circ}C$ plots. Total yield per 10a was higher 33% in 17$^{\circ}C$ plot, 49% in 21$^{\circ}C$ plot, and 37a in $25^{\circ}C$ plots than in control plot, harvested 1, 490kg per 10a. 4. Total yield was highest in 21$^{\circ}C$ plot, followed by $25^{\circ}C$, 17$^{\circ}C$, and control plots. Malformed and fermented fruit rates were the highest in control, followed by 17, 25, and 21$^{\circ}C$ plots and marketable fruit rate was 21, 25, 17$^{\circ}C$, and control plot in order.

  • PDF

Clinical Effects of Prothinoamide, Cycloserine, Para-Aminosalicylic Acid, Ofloxasine in Retreatment of Pulmonary Tuberculosis (폐결핵 재치료 환자에서 Prothionamide, Cycloserine, Paraminosalicylic acid, Ofloxasine을 이용한 경구 4제 요법의 임상 효과)

  • Hong, Jae-Rak;Yoo, Min-Kyu;Jeong, Jae-Man;Kim, Young-Jun;Son, Mal-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.693-700
    • /
    • 1996
  • Background : Antituberculous therapy is set a short-term therpy used isoniazid(INH), rifampin(RFP), ethambutol(EMB), pyrazinamide(PZA) from 1970s' and treatment rate has been very improved. But drug interruption or irregular medication due to side effects and resistance of drug are serious problem to retreatment cases, specially. Ofloxasine(OFX), developed from Quinolone at 1980's is effective not only other respiratory infectious disease but also pulmonary tube rculosis. And this is useful drug instead of injection agents for retreatment patients who have side effects to other drugs, lived far distance from medical clinics. So, we will evaluate theffectiveness as four oral drugs involving OFX. Method : A retrospective study was made through the regular follow up of smear positive cases,who treated by four drug, namely, prothionamide (PTA) cycloserine(CS), OFX, paraminosalicylic acid(pAS). Results: 1) Out of 66case with positive sputum AFB smear, 42(64%)cases achieved the negative conversion. 2) Considering the negative conversion in all group, 34 case (52%) of sputum conversion occured within first 6 months, on the extent of diease was minimal, moderate, far advanced pulmonary tuberculosis, sputum AFB smear negative response to treatment was 100%, 78%, 46% respectively. 3) The roentgenological improvement occured in 38(58%), extent of diease was minimal, moderately, far advanced pulmonary tuberculosis, Roentgenological improvement to retreatment was 75%, 64%, 46%. 4) When the drnation of patients illness was less than 1 year, 1 to 3 years, 3 10 5 years and more than 5 years, sputum AFB smear negative response to retreatment was 100%, 88%, 80%, 52 %. 5) On side effects, major problems are gastrointestinal troubles, mild liver function abnormality, psychotic problemes, and skin problem(urticaria, itching sensation). Conclusion : The duration & extents of patients illness was shorter & minimal, sputum AFB smear negative response rate was better. Radiologic response is better as shorter duration and minimal extent of diease. But, as diease is longer duration & far advanced, sputum negative conversion & Roentgenological improvement is poor and limited. The adverse reaction was mainly observed gastrointestinal troubles(indigestion, abdominal pain, nausea, vomiting, diarrhea) and are well controled by symptomatic management in most patients, as regard to tolerance to the secondary drugs.

  • PDF

Verification of ET and AI Derived Offspring Using on the Genetic Polymorphisms of Microsatellite and Coat Color Related Genes in Jeju Black Cattle (제주흑우 집단에서 모색 관련 유전자와 microsatellite marker의 다형현상을 이용한 수정란이식 및 인공수정 유래 후대우 검증)

  • Han, Sang-Hyun;Ko, Jin-Cheul;Kim, Young-Hoon;Kim, Nam-Young;Kim, Jae-Hwan;Ko, Moon-Suck;Jeong, Ha-Yeon;Cho, In-Cheol;Yang, Young-Hoon;Lee, Sung-Soo
    • Journal of Life Science
    • /
    • v.20 no.3
    • /
    • pp.381-387
    • /
    • 2010
  • To find offspring of Jeju Black cattle (JBC) produced by embryo transfer (ET) and artificial insemination (AI), a molecular genetic study was carried out in candidate cattle populations collected from cattle farms in Jeju Island, Korea. The genetic marker set was composed of 11 ISAG microsatellite (MS) markers, 11 SAES MS markers selected by our preliminary analysis for population diversity of JBC and two major coat color related genes: MC1R and ASIP. The results showed a combined non-exclusion probability for first parent (NE-P1) that was higher than that recommended by ISAG (above 0.9995), and a combined non-exclusion probability for sib identity of $5.3{\times}10^{-10}$. Parentage analysis showed that the cases identified the candidate's father only (77.0%), mother only (54.0%), and both parents (40.5%) in the candidate offspring population. The ET and AI calves were identified as 14.7% in the in vitro fertilized eggs provided and 32.4% in total population, respectively. However, the result from ISAG marker analysis showed 3 identical allele-combinations in 7 calves, and that from ISAG/SAES MS marker combination also showed 1 identical allele-combination in 2 calves. Data from MS and coat-color gene analyses provided information for complete identification of all animals tested. Because the present JBC population was mostly bred using small nuclear founders through bioengineering techniques such as AI and ET, the genetic diversity levels obtained from MS analysis in the JBC population were relatively lower than those of other cattle populations, including Hanwoo. The results suggested that the more efficient marker combinations, including coat color related genotypes, should be studied and used for constructing a system for identification and molecular breeding of JBC as well.

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.