• 제목/요약/키워드: ozone water

검색결과 583건 처리시간 0.026초

고농도 오존수를 이용한 한약재 세척기기에 대한 연구 (A Study on the Development of High Density Ozone Water Cleaning System for Herb Medicine)

  • 김정호;방병훈;이상화;김성희
    • Journal of Acupuncture Research
    • /
    • 제29권2호
    • /
    • pp.9-14
    • /
    • 2012
  • Objectives : This study was designed to evaluate the pesticide residue of herb medicine through high density ozone water cleaning system. Materials and Methods : We purchased ginseng(Panax ginseng) on market and sprayed pesticides (Diazinon) on ginseng. We analyzed pesticide residue according to washing methods(untreated, ozone water cleaning, ultrasonic cleaning, Water cleaning). As a result of each washing methods, in ozone water cleaning method pesticide residue was much less remained than in Ultrasonic Cleaning method and water cleaning method. Conclusions : High density ozone water cleaning is the best method for removing pesticides of herbal medicine.

PAHs 오염 토양내 오존이동특성;함수율과 수분과 토양 유기물의 영향

  • 배기진;정해룡;최희철
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.140-143
    • /
    • 2001
  • The packed column experiments were conducted with commercial Jumunjin sand(SOM content : 0.01 %) and a field soil(SOM content : 0.08 %) in order to understand the effects of water content and soil organic matter(SOM) on the transport of gaseous ozone in unsaturated soil contaminated with phenanthrene. Water content and SOM content were artificially controlled. As water content increased, earlier breakthrough was observed in the beginning of BTC of ozone, because direct contact of gaseous ozone with SOM and phenanthrene was prevented by water film formed between soil particles and gaseous ozone. The total removal of phenanthrene in Jumunjin sand was not affected by water content which was more than 99% at different water content(4.4, 8, 17.3%). However, the removal in field soil at water content 6.5 % and 20 % was 98% and 80 %.

  • PDF

오존용해탱크 구조 개선을 통한 효율적인 마이크로오존버블 생성 (Efficient Micro-Ozone-Bubble Generation by Improving Ozone Dissolution Tank Structure)

  • 박용화;이광희;장암
    • 대한환경공학회지
    • /
    • 제39권10호
    • /
    • pp.549-555
    • /
    • 2017
  • 본 연구는 오존용해탱크 구조에 따라 마이크로오존버블의 분포, 에너지 소비, 수처리 효율이 어떻게 변하는지를 알아보고자 하였다. 오존용해탱크 내부의 격판은 압력의 변화, 전단력, 선회유동을 발생시키고 이는 버블 직경의 크기에 변화를 준다. 버블 직경의 크기는 내부의 격판에 따라 10.5%까지 차이가 났다. 오존 버블 직경의 변화는 에너지 소비와 관련이 깊다. 오존 버블이 작아질수록 버블생성에너지는 높아지지만 용존 효율이 올라가면서 오존생산에너지는 줄어들게 된다. 따라서 버블생성에너지와 오존생산에너지의 합이 최소인 마이크로오존버블을 생성하는 오존용해탱크를 선정하여야 한다. 동일한 양의 오존가스을 방류수에 주입하기 위해 소비된 에너지는 내부의 격판에 따라 2.5%까지 차이가 났다. 하지만 수처리 효율까지 고려한다면 오존용해탱크 선정 조건이 달라진다. 오존 버블이 작아질수록 증가하는 자유라디칼이 수처리에 매우 효율적이기 때문이다. 동일한 오존주입농도에서도 내부의 격판에 따라 수처리 효율이 10.4%까지 차이가 났다. 따라서 수처리 효율과 에너지 효율을 고려하여 합리적인 마이크로오존버블을 생성하는 오존용해탱크 구조에 대하여 연구하였다.

고도정수처리공정에서 오존의 유기물 분해능 (Decomposition of Organic Matters by Ozonation in Advanced Water Treatment Process)

  • 윤태경;이강춘;노병일
    • 한국환경과학회지
    • /
    • 제14권3호
    • /
    • pp.327-333
    • /
    • 2005
  • The performance of ozone contactor in ozone-BAC advanced water treatment process was evaluated by the degree of decomposition of organic matters. The degree was measured by the analyses of $UV_{254}$ absorbance and the concentrations of DOC and BDOC for the sand filtered water and the ozone treated water, respectively. In addition, the ozone concentration in the contactor, required for the maximum BDOC concentration, was selected as the optimum concentration, and the appropriate residential time of ozone treated water in a reservoir was recommended based on the residual ozone concentration in the treated water. The following results were obtained from the pilot scale experiments. By ozonation $UV_{254}$ absorbance was decreased, and BDOC concentration was increased. The change of DOC concentration by ozonation was negligible, but the excess input of ozone resulted in the removal of the small amount of BDOC by complete oxidation. The optimum ozone concentration was 0.58mg $O_3/mg$ DOC. In order to remove residual ozone, 20minutes of the residential time were enough after ozonation.

DOF(Dissolved Ozone Flotation)를 이용한 부유물질과 총인의 제거와 소득의 동시효과에 관한 연구 (Disinfection and Removal of SS and T-P Using DOF (Dissolved Ozone Flotation))

  • 이병호;김성혁;이상배;김미정
    • 상하수도학회지
    • /
    • 제18권2호
    • /
    • pp.215-221
    • /
    • 2004
  • Effluent of wastewater treatment plant is to be disinfected to protect drinking water sources. DOF (Dissolved Ozone Flotation) was developed to meet this purpose. DOF was developed by combining DAF system with ozone. DAF system has good floating power with numerous microbubbles, and ozone has strong oxidation capability. And DOF system has good floating power and strong oxidation capability simultaneously. When DOF was applied to secondary wastewater effluent, color of 11CU in raw water which was secondary effluent was reduced to 1CU by the DOF system. Removal rate of other water quality parameters treated by DOF were also higher than that by DAF, which were proved the strength of oxidation capability of ozone. When ozone concentration of 3.3mg/l were applied in DOF system, general aerobic bacteria were reduced to 5CFU/ml from TNTC (Too many Numbers To Count). With the same ozone concentration, total coliform were not detected at all. These figures are under the numbers of drinking water regulation. These microbes were the target parameters of DOF. It was proved that DOF was very effective in disinfection of wastewater treatment plant effluent as well as in removal of color, turbidity, and T-P.

오존을 이용한 유기물 및 세균의 제거 특성에 관한 연구 (A Study on the Removal Characteristics of Organic matter and Bacteria with the Use of Ozone)

  • 이관영;박상현
    • 한국산업융합학회 논문집
    • /
    • 제10권1호
    • /
    • pp.15-20
    • /
    • 2007
  • The aim of this study is to measure the removal characteristics of organic matter and bacteria with the use of ozone to reduce the problems caused by bacteria and organic matter which appear in sea-water is summer season. When the total input of ozone was $1.4mg/{\ell}O_3$, the removal rate of bacteria and E-coli from sea-water proved to be 100%. With the same input of ozone, on the other hand, the removal rate of COD turned to be relatively low, 50%, which was to the fact that sea-water consists of salt matter which is a kind of COD matter. This result supports the idea that we can keep using ozone steadily in the future to remove organic matters and bacteria from sea-water because ozone destructs relatively less salt matter in sea-water. Also, the treatment effect rate of SS, turbidity and organic matters such as $NH_3$-N, $NO_3$-N etc, was very high. As a result, we assume that the treatment of organic matter in sea-water with ozone is very effective

  • PDF

국내 정수장의 오존 소독능 평가사례를 통한 정수처리기준 개선방안 연구 (Study on Water Treatment Improvement Measures based on Case Studies of Ozone Disinfection at Domestic Water Treatment Plants)

  • 노희수;이경혁;왕창근;손대익;강준원
    • 상하수도학회지
    • /
    • 제25권2호
    • /
    • pp.153-160
    • /
    • 2011
  • Ozone process is currently applied in 24 water treatment plants in Korea to control micropollutants and taste & odor compounds. However, one of the chlorine resistant protozoa, cryptosporidium, is not being considered as ozone disinfection performance whereas U.S. is already regulate Cryptosporidium by ozone disinfection. two ozone plants(PH, UH WTP) operation conditions are investigated for disinfection performance comparing Korea disinfection regulation and U.S. regulation. The ozone plants are unable to get Cryptosporidium inactivation credits by Korea disinfection regulation. However, the inactivation credit for Cryptosporidum was increased when the U.S. disinfection regulation was applied. The Korea disinfection credit regulation need revision to practical aspects.

무성방전형 오존발생장치 제작 및 수질 개선 특성 (Trial Manufacture of Ozone Generator Using Silent Discharge Type and Improvement Properties of the Water Quality in the Lake)

  • 임헌찬;김진규;우성훈
    • 전기학회논문지P
    • /
    • 제50권3호
    • /
    • pp.125-129
    • /
    • 2001
  • ln this paper, a ozone generator using superimposition of silent discharge has been designed and manufactured. This type ozone generator is equipped with three electrodes and two gaps. Ozone is generated by superimposition of silent discharge, which is respectively come from two gaps. The maximum values of ozone concentration, ozone generation flow and ozone energy field were obtained 4,750[ppm], 2.37[g/h], 102.3[g/kWh]. Also, the result of reaction of 1,8921ppm] ozone and the sampling water from the lake, the water quality was improved from IV grade to In grade, and obtained 100[%] sterilization rate of Escherichia coli within 5.0(min).

  • PDF

휴믹물질의 오존산화에 관한 기초연구 (A fundamental study on ozone oxidation of humic substances)

  • 김은호;김영웅;손희종;장성호
    • 환경위생공학
    • /
    • 제14권3호
    • /
    • pp.10-21
    • /
    • 1999
  • The purpose of study were to research the characteristics of water variation adding humic acids to distilled water after ozonation. Upon investigating pH variation with contact time after providing distilled water+air, distilled water+ozone and distilled water-humic acid-air in reactor, it reduced after 60 minute in inletting air and in spite of short contact time did suddenly in inletting ozone. TOC and UV-254 continued to increase with contact time of ozone and humic acids. $NH^{4+}-N$ did slowly increase or decrease after constant contact time of ozone, because $NH^{4+}-N$ was converted into $No^3-N$ by ozone. T-N did suddenly increase after 90minute, but T-P did rarely fluctuate for total experiment. Total 30 species of organic matter were detected by GS/MSD, but 14 species did really tend to increase except for matter identified in distilled water and blank test. Humic acids generated $aliphatic{\cdot}aromatic$ hydrocarbon, alcohol and amine etc., and did various matters without inflow course of contaminants.

  • PDF

오존산화에 의한 정수장의 Microcystin제거 특성에 관한 연구 (A Study on the Removal Characteristics of Microcystin in the Water Treatement Plant by Ozonation)

  • 김민규;권재현;조영하;이진애;권오섭
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.74-83
    • /
    • 2003
  • Microcystin, stable compounds with circular heptapeptides, is presented inside cyanobacterial cell. So far, over 30 types have been known to exist and microcystin-LR, RR among them are the most potent toxin compound. By this reason, a strong oxidant, ozone was used in this study to remove the microcystins produced by cyanobacteria. Removal efficiency of microcystin at M water treatment plant was also evaluated. Microcystin concentration was determined by protein phosphatase inhibition assay. The results showed that dissolved microcystin in raw water detected in the range of 0.011-0.028 ㎍ Microcystin-RR equivalent/l. Above 98% of microcystin was removed through overall treatment system. Therefore, the water treatability of M treatment plant seemed to be excellent. Removal efficiency of microcystin according to unit process varied as characteristics of raw water such as DOC, UV/sub 254/ and turbidity. Removal efficiency of microcystin by ozonation was investigated in laboratory according to contact time and ozone dose. Dissolved microcystin was increased by twice fold according to ozone contact time, but increased by fifth fold according to ozone dose. So, changing of ozone dose more affected microcystin release than changing of ozone contact time. Behavior of microcystin by ozonation was similar to that of DOC, and residual ozone concentration gave influence to removal ratio of microcystin. In conclusion, single ozone treatment wasn't effective on microcystin removal in case of water containing a lot of cells. Therefore, it's more effective to use ozonation process after the removal of cyanobacterial cells in advance.