• Title/Summary/Keyword: ozone water

Search Result 583, Processing Time 0.028 seconds

A Study on the Development of High Density Ozone Water Cleaning System for Herb Medicine (고농도 오존수를 이용한 한약재 세척기기에 대한 연구)

  • Kim, Jeong-Ho;Bang, Byeong-Hun;Lee, Sang-Hwa;Kim, Sung-Hee
    • Journal of Acupuncture Research
    • /
    • v.29 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • Objectives : This study was designed to evaluate the pesticide residue of herb medicine through high density ozone water cleaning system. Materials and Methods : We purchased ginseng(Panax ginseng) on market and sprayed pesticides (Diazinon) on ginseng. We analyzed pesticide residue according to washing methods(untreated, ozone water cleaning, ultrasonic cleaning, Water cleaning). As a result of each washing methods, in ozone water cleaning method pesticide residue was much less remained than in Ultrasonic Cleaning method and water cleaning method. Conclusions : High density ozone water cleaning is the best method for removing pesticides of herbal medicine.

PAHs 오염 토양내 오존이동특성;함수율과 수분과 토양 유기물의 영향

  • 배기진;정해룡;최희철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.140-143
    • /
    • 2001
  • The packed column experiments were conducted with commercial Jumunjin sand(SOM content : 0.01 %) and a field soil(SOM content : 0.08 %) in order to understand the effects of water content and soil organic matter(SOM) on the transport of gaseous ozone in unsaturated soil contaminated with phenanthrene. Water content and SOM content were artificially controlled. As water content increased, earlier breakthrough was observed in the beginning of BTC of ozone, because direct contact of gaseous ozone with SOM and phenanthrene was prevented by water film formed between soil particles and gaseous ozone. The total removal of phenanthrene in Jumunjin sand was not affected by water content which was more than 99% at different water content(4.4, 8, 17.3%). However, the removal in field soil at water content 6.5 % and 20 % was 98% and 80 %.

  • PDF

Efficient Micro-Ozone-Bubble Generation by Improving Ozone Dissolution Tank Structure (오존용해탱크 구조 개선을 통한 효율적인 마이크로오존버블 생성)

  • Park, Yong-hwa;Lee, Gwang-hi;Jang, Am
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.549-555
    • /
    • 2017
  • The purpose of this study is to investigate how ozone-dissolution-tank structure affects micro-ozone-bubble distribution, energy consumption and water treatment efficiency. The partition walls inside the ozone-dissolution-tank generate pressure changes, shear forces, and swirling flows, which change the size of the bubble diameter. The size of the bubble diameter differs by 10.5% depending on the partition walls. Changes in ozone-bubble diameter are related to energy consumption. As the ozone-bubble becomes smaller, the bubble generation energy increases, but the ozone production energy decreases as the dissolution efficiency increases. Therefore, an ozone-dissolution-tank should be determined by means of an optimal condition producing a micro-ozone-bubble with a minimum sum of bubble generation energy and ozone production energy. The energy consumed to inject the same amount of ozone into the effluent differs by 2.5% depending on the partition walls. However, considering the water treatment efficiency, the conditions for selecting the ozone-dissolution-tank are variable. This is because the free radicals that increase as the ozone-bubble gets smaller are very efficient for water treatment. Even at the same ozone injection concentration, the water treatment efficiency differs by 10.4% according to the partition walls. Therefore, we have studied ozone-dissolution-tank structure which produces reasonable ozone-bubble considering water treatment efficiency and energy efficiency.

Decomposition of Organic Matters by Ozonation in Advanced Water Treatment Process (고도정수처리공정에서 오존의 유기물 분해능)

  • Yoon Taekyung;Lee Gangchoon;Noh Byeongjil
    • Journal of Environmental Science International
    • /
    • v.14 no.3
    • /
    • pp.327-333
    • /
    • 2005
  • The performance of ozone contactor in ozone-BAC advanced water treatment process was evaluated by the degree of decomposition of organic matters. The degree was measured by the analyses of $UV_{254}$ absorbance and the concentrations of DOC and BDOC for the sand filtered water and the ozone treated water, respectively. In addition, the ozone concentration in the contactor, required for the maximum BDOC concentration, was selected as the optimum concentration, and the appropriate residential time of ozone treated water in a reservoir was recommended based on the residual ozone concentration in the treated water. The following results were obtained from the pilot scale experiments. By ozonation $UV_{254}$ absorbance was decreased, and BDOC concentration was increased. The change of DOC concentration by ozonation was negligible, but the excess input of ozone resulted in the removal of the small amount of BDOC by complete oxidation. The optimum ozone concentration was 0.58mg $O_3/mg$ DOC. In order to remove residual ozone, 20minutes of the residential time were enough after ozonation.

Disinfection and Removal of SS and T-P Using DOF (Dissolved Ozone Flotation) (DOF(Dissolved Ozone Flotation)를 이용한 부유물질과 총인의 제거와 소득의 동시효과에 관한 연구)

  • Lee., Byoung-Ho;Kim, Sung-Hyuk;Lee, Sang-Bae;Kim, Mi-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.215-221
    • /
    • 2004
  • Effluent of wastewater treatment plant is to be disinfected to protect drinking water sources. DOF (Dissolved Ozone Flotation) was developed to meet this purpose. DOF was developed by combining DAF system with ozone. DAF system has good floating power with numerous microbubbles, and ozone has strong oxidation capability. And DOF system has good floating power and strong oxidation capability simultaneously. When DOF was applied to secondary wastewater effluent, color of 11CU in raw water which was secondary effluent was reduced to 1CU by the DOF system. Removal rate of other water quality parameters treated by DOF were also higher than that by DAF, which were proved the strength of oxidation capability of ozone. When ozone concentration of 3.3mg/l were applied in DOF system, general aerobic bacteria were reduced to 5CFU/ml from TNTC (Too many Numbers To Count). With the same ozone concentration, total coliform were not detected at all. These figures are under the numbers of drinking water regulation. These microbes were the target parameters of DOF. It was proved that DOF was very effective in disinfection of wastewater treatment plant effluent as well as in removal of color, turbidity, and T-P.

A Study on the Removal Characteristics of Organic matter and Bacteria with the Use of Ozone (오존을 이용한 유기물 및 세균의 제거 특성에 관한 연구)

  • Lee, Kwan-Young;Park, Sang-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.1
    • /
    • pp.15-20
    • /
    • 2007
  • The aim of this study is to measure the removal characteristics of organic matter and bacteria with the use of ozone to reduce the problems caused by bacteria and organic matter which appear in sea-water is summer season. When the total input of ozone was $1.4mg/{\ell}O_3$, the removal rate of bacteria and E-coli from sea-water proved to be 100%. With the same input of ozone, on the other hand, the removal rate of COD turned to be relatively low, 50%, which was to the fact that sea-water consists of salt matter which is a kind of COD matter. This result supports the idea that we can keep using ozone steadily in the future to remove organic matters and bacteria from sea-water because ozone destructs relatively less salt matter in sea-water. Also, the treatment effect rate of SS, turbidity and organic matters such as $NH_3$-N, $NO_3$-N etc, was very high. As a result, we assume that the treatment of organic matter in sea-water with ozone is very effective

  • PDF

Study on Water Treatment Improvement Measures based on Case Studies of Ozone Disinfection at Domestic Water Treatment Plants (국내 정수장의 오존 소독능 평가사례를 통한 정수처리기준 개선방안 연구)

  • Noh, Hee-Su;Lee, Kyung-Hyuk;Wang, Chang-Keun;Son, Dae-Ik;Kang, Joon-Wun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.153-160
    • /
    • 2011
  • Ozone process is currently applied in 24 water treatment plants in Korea to control micropollutants and taste & odor compounds. However, one of the chlorine resistant protozoa, cryptosporidium, is not being considered as ozone disinfection performance whereas U.S. is already regulate Cryptosporidium by ozone disinfection. two ozone plants(PH, UH WTP) operation conditions are investigated for disinfection performance comparing Korea disinfection regulation and U.S. regulation. The ozone plants are unable to get Cryptosporidium inactivation credits by Korea disinfection regulation. However, the inactivation credit for Cryptosporidum was increased when the U.S. disinfection regulation was applied. The Korea disinfection credit regulation need revision to practical aspects.

Trial Manufacture of Ozone Generator Using Silent Discharge Type and Improvement Properties of the Water Quality in the Lake (무성방전형 오존발생장치 제작 및 수질 개선 특성)

  • 임헌찬;김진규;우성훈
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.125-129
    • /
    • 2001
  • ln this paper, a ozone generator using superimposition of silent discharge has been designed and manufactured. This type ozone generator is equipped with three electrodes and two gaps. Ozone is generated by superimposition of silent discharge, which is respectively come from two gaps. The maximum values of ozone concentration, ozone generation flow and ozone energy field were obtained 4,750[ppm], 2.37[g/h], 102.3[g/kWh]. Also, the result of reaction of 1,8921ppm] ozone and the sampling water from the lake, the water quality was improved from IV grade to In grade, and obtained 100[%] sterilization rate of Escherichia coli within 5.0(min).

  • PDF

A fundamental study on ozone oxidation of humic substances (휴믹물질의 오존산화에 관한 기초연구)

  • 김은호;김영웅;손희종;장성호
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.3
    • /
    • pp.10-21
    • /
    • 1999
  • The purpose of study were to research the characteristics of water variation adding humic acids to distilled water after ozonation. Upon investigating pH variation with contact time after providing distilled water+air, distilled water+ozone and distilled water-humic acid-air in reactor, it reduced after 60 minute in inletting air and in spite of short contact time did suddenly in inletting ozone. TOC and UV-254 continued to increase with contact time of ozone and humic acids. $NH^{4+}-N$ did slowly increase or decrease after constant contact time of ozone, because $NH^{4+}-N$ was converted into $No^3-N$ by ozone. T-N did suddenly increase after 90minute, but T-P did rarely fluctuate for total experiment. Total 30 species of organic matter were detected by GS/MSD, but 14 species did really tend to increase except for matter identified in distilled water and blank test. Humic acids generated $aliphatic{\cdot}aromatic$ hydrocarbon, alcohol and amine etc., and did various matters without inflow course of contaminants.

  • PDF

A Study on the Removal Characteristics of Microcystin in the Water Treatement Plant by Ozonation (오존산화에 의한 정수장의 Microcystin제거 특성에 관한 연구)

  • 김민규;권재현;조영하;이진애;권오섭
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.74-83
    • /
    • 2003
  • Microcystin, stable compounds with circular heptapeptides, is presented inside cyanobacterial cell. So far, over 30 types have been known to exist and microcystin-LR, RR among them are the most potent toxin compound. By this reason, a strong oxidant, ozone was used in this study to remove the microcystins produced by cyanobacteria. Removal efficiency of microcystin at M water treatment plant was also evaluated. Microcystin concentration was determined by protein phosphatase inhibition assay. The results showed that dissolved microcystin in raw water detected in the range of 0.011-0.028 ㎍ Microcystin-RR equivalent/l. Above 98% of microcystin was removed through overall treatment system. Therefore, the water treatability of M treatment plant seemed to be excellent. Removal efficiency of microcystin according to unit process varied as characteristics of raw water such as DOC, UV/sub 254/ and turbidity. Removal efficiency of microcystin by ozonation was investigated in laboratory according to contact time and ozone dose. Dissolved microcystin was increased by twice fold according to ozone contact time, but increased by fifth fold according to ozone dose. So, changing of ozone dose more affected microcystin release than changing of ozone contact time. Behavior of microcystin by ozonation was similar to that of DOC, and residual ozone concentration gave influence to removal ratio of microcystin. In conclusion, single ozone treatment wasn't effective on microcystin removal in case of water containing a lot of cells. Therefore, it's more effective to use ozonation process after the removal of cyanobacterial cells in advance.